KITOZER Rackmount UPS 6kVA 3U Network Server Rack

Product Overview

The KITOZER Rackmount UPS 6kVA is a 3U online double-conversion unit engineered for high-density network racks, small data centers, and distributed IT rooms. Delivering 6000VA and 5400W at power factor 0.9, it supports blade servers, storage arrays, and high-end networking gear while fitting in just 3U of rack space. The unit uses transformer-less high-frequency topology to keep weight and footprint low, yet maintains full isolation through input power factor correction and output EMI filtering. Front-access batteries allow hot-swap replacement, and the optional long-run battery cabinet supports multi-hour autonomy.

Built for enterprise IT environments, the KITOZER 6kVA achieves 94 percent online efficiency, reducing cooling load and operating cost. The unit supports parallel N+X for up to 4 units, allowing operators to build redundant systems as load grows. A color touch LCD provides real-time metering, event log, and waveform capture for troubleshooting. Native Modbus TCP and SNMPv3 eliminate the need for separate management cards.

The KITOZER 6kVA is CE certified and complies with IEC 62040 safety and EMC standards. The wide input voltage range from 120 to 280VAC allows deployment in regions with unstable grid. Intelligent battery management monitors cell voltage, charge current, and temperature, maximizing battery life and predicting end-of-life. The unit is designed for 24/7 operation in data center and IT room environments.

Technical Specifications

Input 200 to 240VAC nominal, range 120 to 280VAC, input power factor greater than 0.99, THDi less than 5 percent. Output 200, 208, 220, 230, or 240VAC selectable, voltage regulation plus or minus 1 percent, online efficiency 94 percent. Output sockets: hardwired terminal plus 4 C19. Inverter overload 110 percent for 10 min, 125 percent for 5 min.

Internal battery provides 5 to 10 minutes at half load. External battery cabinet supports up to 4 strings. Parallel N+X for up to 4 units. Communications: Modbus TCP, SNMP, USB, RS232, dry contact. Color LCD with event log, Ethernet management port. Dimensions 438 by 700 by 132 mm, weight 45 kg. Operating temperature 0 to 40 degrees Celsius. Noise level less than 55 dB(A). Three-year standard warranty.

Application Scenarios

This 6kVA rack UPS is commonly installed in mid-size data center IT rooms, retail core networks, hospital server closets, university computer labs, and industrial control rooms. It powers blade chassis, SAN storage, core routers, and firewalls, and is frequently paired with external battery cabinets for sites without generators. The parallel option enables N+1 redundancy for applications that cannot tolerate single-point failure.

Additional deployments include financial back-office systems, media production servers, government data rooms, and cloud edge nodes. The 3U compact size maximizes usable rack space in high-density cabinets. External battery cabinets are chosen when generator start-up exceeds 15 seconds or when orderly shutdown of virtualized hosts must be supported. The unit is also suitable for manufacturing execution systems and large corporate office IT rooms.

Key Advantages

High input power factor greater than 0.99 and low THDi less than 5 percent help the site comply with IEEE 519 and avoid penalty charges. 94 percent online efficiency reduces heat and electricity cost. 3U compact size maximizes usable rack space. Hot-swap batteries and front access reduce service time.

Parallel N+X up to 4 units scales with load growth. Built-in SNMP and Modbus TCP eliminate need for separate management card. Wide input window and generator compatibility make deployment flexible. Color touch LCD with event log reduces troubleshooting time. Three-year standard warranty. CE certified for global deployment.

Installation and Maintenance Advice

Use reinforced rack rails rated for 45 kg. Provide a dedicated 32A breaker and hardwire input with proper torque. Keep top and bottom vent areas clear. When adding external battery cabinets, use matching KITOZER cabling and install DC breakers.

For parallel systems, match battery state of charge before bringing units online. Test batteries every 6 months and replace at 3 to 5 years. Maintain room temperature at 20 to 25 degrees Celsius. Update firmware in maintenance window. Keep service bypass instructions posted inside rack. Keep spare fans and contactors on site for fast replacement.

Price

From $2,480 per unit. External battery cabinet, parallel kit, and extended warranty quoted separately.