KITOZER 1500kW Container Diesel Generator For Power Plant

The KITOZER 1500 kW container diesel generator is a high-capacity outdoor power module delivering 1875 kVA for medium power plants, utility substations, mining operations, and large data centers. Housed in a 40-foot high-cube ISO container with heavy acoustic insulation, integrated exhaust, fuel tank, fire suppression, and personnel access, the unit is engineered for 24/7 prime power operation in remote or harsh environments. Multiple containers can be paralleled to form a complete power plant without a conventional generator building.

Technical Specifications

Standby 1650 kW (2062.5 kVA), prime 1500 kW (1875 kVA), 400V 50Hz three-phase. Engine: V16 or V20, water-cooled, turbocharged, aftercooled, common rail, 1500 rpm. Alternator: brushless, PMG, AVR, class H, IP23, 2/3 pitch. Container: 40ft high-cube ISO, 150 mm acoustic, IP54, personnel doors both ends, ventilation louvers, internal lighting, floor drain, secondary containment, CO2 fire suppression option. Noise 72 to 78 dB(A) at 7 m. Controller: deep-sea DSE890 or ComAp IntiGen, color touch, Modbus TCP, SNMP, paralleling up to 16 units. Integrated tank 3000 L, external 20000 L option. Circuit breaker 3200A ACB. Dimensions 12192 x 2438 x 2896 mm, dry weight 38000 kg.

Key Advantages

The 40-foot container format allows the entire power module to ship as a standard ISO unit, reducing transport cost and customs complexity. Pre-installed fire suppression, gas detection, and secondary containment meet most environmental and safety regulations. Paralleling-ready controllers allow up to 16 units to share load, with automatic start-stop based on demand. KITOZER can supply the complete plant including HV switchgear, step-up transformer, fuel farm, and monitoring SCADA as a turnkey package.

Applications

Typical uses include isolated mining and quarry sites, remote oil and gas fields, island micro-grids, and disaster relief power plants. Data centers and cloud campuses use 1500 kW containers as outdoor N+1 standby. Utility companies deploy them as temporary peaking plants during grid maintenance or peak demand periods. Large industrial facilities including steel mills, cement plants, and refineries use them for emergency standby of critical processes.

Installation and Maintenance

Place the container on a reinforced concrete raft sized for 40 tonne mass, with leveling pads and drainage. Connect external fuel, power cables via gland plate, and exhaust stack. For paralleling plants, KITOZER supplies a dedicated MV switchgear with synchronization, protection relays, and SCADA. Cold climate options include jacket water heater, oil pan heater, and battery blankets; hot climate options include desert filters and larger radiators.

Maintenance: oil and filter every 250 hours, fuel filter every 500 hours, coolant every 2 years, valve adjustment every 3000 hours, top-end overhaul around 30000 hours. Quarterly load bank tests, monthly exercise, and annual infrared inspection. Inspect container seals, fire suppression, and gas detection every 6 months. KITOZER offers a full O&M contract with remote monitoring and local engineer support.

Price

From $310,000 per unit for the 1500 kW container generator. Contact KITOZER for turnkey power plant pricing including switchgear and fuel farm. Tel/WeChat: +86 13922289957.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com