KITOZER Smart PDU: 8-Port 16A Monitored Rack Power Distribution

Product Overview

The KITOZER 8-port 16A monitored smart PDU is a 1U rack-mounted power distribution unit designed for small server rooms, network closets, edge computing cabinets, and remote branch office infrastructure. It converts a single 16A single-phase input into eight individually accessible output outlets while continuously measuring input voltage, input current, active power, apparent power, energy consumption, and power factor. A bright front-panel LCD displays real-time measurements, and an embedded Ethernet port provides remote monitoring through a built-in web interface, Modbus TCP, or SNMP platform integration. The unit is built around a high-reliability controller and precision current sensing chips, giving facility managers accurate visibility into rack-level energy draw without requiring external metering hardware. Each outlet is clearly numbered, and the input circuit is protected by a rated miniature circuit breaker to isolate faults and protect downstream IT loads.

The PDU chassis is constructed from folded steel sheet with a black powder-coated finish, and the internal copper busbar is sized for continuous 16A duty with margin for inrush. The controller runs an embedded real-time operating system that samples measurements once per second and pushes them to the management platform on demand. No external software license is required, because the web interface is built into the unit itself. Firmware can be upgraded over the network, and configuration can be exported to a file so replacements can be provisioned in minutes.

Technical Specifications

Input: single phase 200 to 240VAC, 50 or 60Hz, rated 16A. Output: eight IEC C13 outlets, each rated 10A, total output 16A maximum. Metering accuracy: voltage plus or minus 1 percent, current plus or minus 1 percent, energy plus or minus 2 percent. Display: 1.8-inch color LCD showing voltage, current, kW, kWh, power factor, and frequency. Communication: 10 or 100Mbps Ethernet, RJ45, supporting Modbus TCP, SNMP v1, v2c, and v3, HTTP, HTTPS, and email alarm notifications. Alarms: over-voltage, under-voltage, over-current, overload, and outlet loss, delivered via email, SNMP trap, and visible LED. Mechanical: 1U rack mount, 19-inch standard, steel chassis with black powder coating, dimensions 482 x 44 x 260 mm, weight 2.4 kg. Operating temperature: 0 to 45 degrees Celsius. Safety: CE, RoHS, IEC 60950 compliant. Brand: KITOZER. Warranty: 3 years.

Input cord length is 2 meters, terminated with a C14 plug, or available hardwired on request. The unit consumes less than 5 watts in standby. The Ethernet port auto-negotiates speed and duplex, and supports DHCP or static IP assignment. Password protection includes account lockout after repeated failed logins. The web dashboard shows a single-page summary of all measurements with trend charts for the last 24 hours. A built-in real-time clock stamps every alarm and energy log entry.

Application Scenarios

This PDU is widely deployed in enterprise branch server cabinets, retail point-of-service server racks, university network closets, security video surveillance server rooms, and small medical imaging equipment racks. It is also suitable for laboratory test benches, broadcast equipment racks, and factory floor industrial control cabinets where rack-level energy monitoring is required. Because the unit supports remote alarm notification, it is particularly valuable for unmanned or lightly staffed sites where a technician cannot be on site around the clock. Operators can log in from a central network operations center to check energy consumption, compare branch sites, and schedule predictive maintenance based on actual load trends.

Co-location operators use the energy data to bill tenants by measured consumption rather than flat rate, which tenants accept because the measurement is transparent. School IT teams use the alarms to detect a failed power supply or a blocked air filter before the server overheats. Manufacturing sites mount the PDU inside control cabinets to monitor energy draw of PLCs, HMI panels, and servo drives. The unit also fits in outdoor telecom huts when paired with a weatherproof enclosure, because the sensing electronics tolerate a wide temperature range.

Advantages and Benefits

The KITOZER 8-port smart PDU replaces basic power strips with a fully monitored distribution node, enabling data-driven capacity planning and reducing the risk of silent overloads. Precision metering allows operators to identify idle or underutilized servers and right-size provisioning. Remote alarm notifications shorten mean time to recovery, because faults are flagged within seconds rather than discovered during a site visit. The compact 1U form factor leaves valuable rack space available for servers and switches. A built-in temperature sensor on the PDU helps correlate power draw with cabinet ambient temperature, supporting airflow optimization. The web interface requires no additional software, which simplifies deployment and lowers total cost of ownership compared with proprietary monitoring gateways.

Compared with unmetered rack strips, the smart PDU pays for itself within a year through avoided overload trips and reduced truck rolls. The open protocol support means the unit works with any standard monitoring platform, so customers are not locked into a vendor ecosystem. The 1 percent measurement class matches the accuracy of revenue-grade plug-in meters at a fraction of the cost. The unit also supports scheduled reboot sequences for connected devices when used in the switched variant, expanding its role from a sensor into an active management node.

Installation and Maintenance Recommendations

Mount the unit in a standard 19-inch rack using the included rack ears, ensuring at least one rack unit of clearance above and below for ventilation. Route the input cord away from network cables to minimize electromagnetic interference, and label each outlet number corresponding to the connected device in the rack diagram. During commissioning, assign a static IP address from the site DHCP reservation list and configure the NTP server, sender email account, and recipient alarm distribution list. Periodically verify metering accuracy against a calibrated clamp meter once per year. Inspect the input plug and outlet connections during quarterly preventive maintenance, and tighten terminal screws if the unit is hardwired. Keep the LCD display clear of obstruction so on-site staff can read status at a glance.

When planning the branch circuit, size the upstream breaker at 16A and use cable with ampacity suitable for the installation environment. Configure alarm thresholds at 80 percent of rated current so warnings arrive before the breaker trips. Test the email alarm by temporarily setting a low over-current threshold and confirming the message is received. Keep the latest firmware image downloaded from the vendor portal, and schedule a firmware update during a maintenance window. Document the IP address, login credentials, and alarm contacts in the rack file so the next technician can take over without delay.

Price

From $185 per piece. Contact the KITOZER sales team for volume pricing, OEM customization, and factory lead time.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com