Table of Contents
ToggleProduct Overview
The KITOZER Tower UPS 10kVA is a floor-standing online double-conversion system delivering 10kW at power factor 1.0 for small and medium data centers, industrial plants, and commercial buildings. Three-phase input and three-phase output balance load across facility distribution, while the transformer-less high-frequency topology achieves up to 96 percent efficiency. The unit integrates an internal maintenance bypass, comprehensive monitoring, and native parallel capability for N+1 redundancy. Front-access batteries and intuitive touchscreen HMI simplify installation and daily operation.
Built for 24/7 mission-critical operation, the KITOZER 10kVA tower UPS uses IGBT-based inverter technology with digital signal processor control for precise output voltage and frequency regulation. The wide input voltage window from 304 to 478VAC allows the unit to ride through deep sags and swells without switching to battery, extending battery life and reducing cycling. Input power factor correction greater than 0.99 and total harmonic distortion less than 3 percent help the site comply with IEEE 519 and avoid utility penalty charges.
The unit is CE certified and complies with IEC 62040 safety and EMC standards. The 7-inch color touchscreen displays real-time input, output, load, battery, temperature, and event history. The internal maintenance bypass allows safe servicing of the UPS while the load remains energized, reducing planned downtime windows. Intelligent battery management monitors cell voltage, charge current, and temperature, performing periodic self-tests and predicting end-of-life.
Technical Specifications
Input 380, 400, or 415V three phase plus neutral, range 304 to 478VAC, input PF greater than 0.99, THDi less than 3 percent. Output 380, 400, or 415V three phase, PF 1.0, voltage regulation plus or minus 1 percent, online efficiency 96 percent. Overload 110 percent for 60 min, 125 percent for 10 min, 150 percent for 1 min. Internal VRLA battery provides 10 to 15 minutes at half load; external battery cabinet extends runtime.
Parallel N+1 up to 4 units. Maintenance bypass standard. Communications: Modbus TCP, SNMPv3, Web HMI, USB, RS232, dry contacts. 7-inch color touch LCD. Dimensions 600 by 800 by 1600 mm, weight 280 kg. IP20 cabinet. Operating temperature 0 to 40 degrees Celsius. Noise level less than 65 dB(A). Event log stores 1024 records. Three-year standard warranty.
Application Scenarios
This tower UPS is deployed in small data centers, enterprise server rooms, manufacturing automation lines, hospital critical care systems, shopping mall BMS, banking back offices, and university laboratories. Three-phase output supports balanced IT and mechanical loads. The parallel option provides redundancy for business-critical systems, and external battery cabinets are used where generator start-up is slow or not available.
Additional applications include pharmaceutical manufacturing, food processing lines, water treatment plants, and transportation hubs. The N+1 parallel configuration is chosen when uptime SLAs require redundant power. External battery cabinets support 30 minutes to 4 hours of autonomy for orderly shutdown or generator ride-through. The unit is also suitable for government data centers and large corporate office IT rooms.
Key Advantages
Power factor 1.0 delivers full 10kW real output. 96 percent online efficiency cuts energy waste and cooling cost. Low THDi less than 3 percent protects upstream generator and transformer. Internal maintenance bypass allows safe service without load interruption. Native parallel up to 4 units supports N+1 redundancy and pay-as-you-grow.
Wide input window rides through sags and spikes. Color touchscreen and event log reduce troubleshooting time. Intelligent battery management extends battery life. Comprehensive communication protocols fit DCIM and BMS platforms. Robust overload rating supports motor and inrush loads. CE certified for global deployment. Three-year standard warranty.
Installation and Maintenance Advice
Place on level concrete floor with adequate front and rear clearance for service. Connect three-phase input with proper breaker size and observe phase rotation. Battery cabinet cables must be sized for fault current. Keep ambient 20 to 25 degrees Celsius.
Test batteries every 6 months with impedance meter. Replace batteries at 4 to 5 years. Annual preventive maintenance includes fan inspection, capacitor check, and terminal torque. Update firmware via USB in maintenance window. For parallel systems, use dedicated paralleling cables and identical firmware. Label bypass positions clearly.
Price
From $6,800 per unit. External battery cabinet and parallel kit quoted separately. Contact KITOZER factory for bulk pricing and lead time.