KITOZER
KITOZER

KITOZER 200kW Natural Gas Generator For CHP

The KITOZER 200 kW natural gas generator is a spark-ignited gas genset delivering 250 kVA for combined heat and power (CHP), grid peak shaving, and continuous prime power in industrial, commercial, and district energy applications. Powered by a turbocharged natural gas engine with lambda closed-loop control, three-way catalyst, and brushless alternator, the set produces low-emission electricity while recovering jacket water and exhaust heat for hot water or space heating. The unit is designed for 24/7 operation on pipeline natural gas, bottled LPG, or biogas mixtures with appropriate derating.

Technical Specifications

Standby 220 kW (275 kVA), prime 200 kW (250 kWe), 400V 50Hz. Engine: six-cylinder, turbocharged, spark-ignited, lambda closed-loop, 1500 rpm. Alternator: brushless, PMG, AVR, class H, IP23. Emission: three-way catalyst, NOx below 500 mg/Nm3 at 15 percent O2, CE certified. Heat recovery: jacket water 80 kWth, exhaust 120 kWth optional. Controller: deep-sea DSE8610 gas version, Modbus, remote start. Gas train: pressure regulator, safety shutoff, leakage detector. Dimensions 3000 x 1200 x 1800 mm, dry weight 2800 kg.

Key Advantages

The CHP configuration reaches overall energy efficiency of 80 to 90 percent when heat is recovered, drastically reducing total energy cost for factories, hotels, hospitals, and district heating networks. Gas fuel avoids diesel storage and spill risk, making the unit suitable for urban sites and sensitive environments. The lambda closed-loop control maintains stable emissions across varying gas quality. KITOZER offers optional grid-export synchronization for sites that sell surplus electricity back to the utility.

Applications

Typical users include food processing plants, breweries, and textile mills that need both electricity and process heat; hotels, hospitals, and swimming pools that require hot water; district heating schemes and biomass boiler houses; and commercial buildings with high thermal demand. Farms with biogas upgrading use the set to combust pipeline-quality gas. Remote gas stations and pipeline compressor stations also rely on gas gensets for local power.

Installation and Maintenance

Install on a level concrete plinth with anti-vibration mounts. Ventilation must remove at least 30 percent more heat than the electrical output. Gas piping must be sized for 3 bar inlet pressure with a dedicated safety shutoff valve leak detector. Exhaust discharge must be routed vertically away from air intakes. For CHP, connect jacket water and exhaust heat exchangers to the site heating loop with circulation pumps.

Maintenance: spark plugs every 500 hours, oil and filter every 500 hours, gas filter every 1000 hours, coolant every 2 years. Inspect catalyst, lambda sensors, and gas train safety valves annually. KITOZER recommends a remote monitoring package that alerts operators to fuel pressure, exhaust temperature, and efficiency drift.

Price

From $52,000 per unit for the 200 kW natural gas generator. Contact KITOZER for CHP heat recovery, grid export, and emission options. Tel/WeChat: +86 13922289957.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com