KITOZER
KITOZER

KITOZER High Frequency UPS 20kVA 96% Efficiency Online

Product Overview

The KITOZER High Frequency UPS 20kVA is a transformer-less online double-conversion system delivering 20kW at power factor 1.0 for data centers, IT rooms, and commercial buildings. The high-frequency topology eliminates the heavy isolation transformer, reducing size, weight, and heat while achieving up to 96 percent online efficiency. The unit supports parallel operation up to 8 units for N+X redundancy and includes an integrated maintenance bypass, smart battery management, and a color touchscreen HMI.

Built for 24/7 IT operation, the KITOZER 20kVA high-frequency UPS uses IGBT inverter technology with DSP control for precise output regulation. Input power factor correction greater than 0.99 and THDi less than 3 percent ensure IEEE 519 compliance. The wide input range from 304 to 478VAC rides through deep sags without battery switching. The compact footprint saves valuable floor space in IT rooms.

The unit is CE certified and complies with IEC 62040 safety and EMC standards. The 7-inch color touchscreen provides real-time metering, event log, and waveform capture. The integrated maintenance bypass allows safe service without load interruption. Intelligent battery management monitors cell voltage, temperature, and charge current, performing periodic self-tests. Native Modbus TCP and SNMPv3 integration fits DCIM and BMS platforms.

Technical Specifications

Input 380, 400, or 415V three phase, range 304 to 478VAC, input PF greater than 0.99, THDi less than 3 percent. Output 380, 400, or 415V three phase, PF 1.0, online efficiency 96 percent. Overload 110 percent 60 min, 125 percent 10 min. External battery cabinet for long runtime. Parallel up to 8 units.

Maintenance bypass standard. Communications: Modbus TCP, SNMPv3, Web HMI, USB, dry contacts. Dimensions 600 by 900 by 1800 mm, weight 380 kg. IP20 cabinet. Operating temperature 0 to 40 degrees Celsius. Noise level less than 65 dB(A). Event log stores 1024 records. Three-year standard warranty.

Application Scenarios

Deployments include data centers, enterprise server rooms, hospital IT, banking back offices, and large commercial buildings. The high-efficiency design reduces operating cost and cooling load. Parallel configurations provide redundancy for critical IT loads.

Additional applications include university computer labs, government data rooms, retail backbone networks, and media production servers. External battery cabinets bridge generator start-up or support orderly shutdown. The compact footprint saves floor space. The wide input window allows deployment in regions with unstable grid voltage.

Key Advantages

96 percent online efficiency cuts energy cost. Compact size and light weight save floor space. PF 1.0 delivers full 20kW output. Low THDi protects upstream grid. Parallel up to 8 units.

Maintenance bypass supports live service. Comprehensive monitoring via SNMP and Modbus. Color touchscreen and event log reduce troubleshooting time. Smart battery management extends battery life. CE certified for global deployment. Three-year standard warranty.

Installation and Maintenance Advice

Install on level floor. Provide dedicated input breaker. For parallel systems, use dedicated paralleling cables. Battery cabinet cables must be fused.

Test batteries every 6 months. Keep ambient 20 to 25 degrees Celsius. Annual preventive maintenance includes fan and capacitor inspection. Label bypass positions clearly. Keep spare fans on site.

Price

From $9,800 per unit. Battery cabinet and parallel kit quoted separately. Contact KITOZER factory for bulk pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com