The KITOZER 48V/200A high frequency switching power plant is a floor-standing DC power system designed for medium to large telecom sites, enterprise data closets, and transmission node rooms. It combines ten 48V/20A high-frequency rectifier modules with integrated AC and DC distribution in a 42U cabinet. Efficiency reaches 96% at typical load, significantly reducing energy cost versus legacy phase-controlled rectifiers. The supervisory controller provides web-based remote management, event logging, and battery test scheduling. This plant is the standard power platform for modern 4G and 5G communication rooms.
The plant uses a distributed control architecture where each rectifier module communicates independently with the supervisory controller. This means a single module failure does not affect monitoring of other modules. The cabinet is designed with front-to-back airflow, enabling integration into data center hot-aisle cold-aisle containment. The controller supports role-based access, with different permission levels for operators, maintainers, and administrators.
Technical Specifications
Input: 380V three phase, 304-456V AC, 50/60Hz. Output: 42-58V DC, rated 48V/200A. Rectifiers: 48V/20A hot-swap, 10 slots. Efficiency: up to 96%. Power factor: greater than 0.99. THDi: less than 3%. AC distribution: 125A main breaker, class C surge. DC distribution: up to 48 branch fuses with monitoring. Battery: two groups, 48V. Controller: 7-inch LCD, Ethernet, RS485, SNMP, dry contacts. Alarms: comprehensive. Operating temperature: -5C to +55C. Cooling: redundant fans. Cabinet: 600mm x 600mm x 2000mm. Weight: approximately 280kg. KITOZER, 5-year warranty.
Application Scenarios
This 200A plant serves medium macro base stations, indoor distributed antenna headends, optical transmission nodes, enterprise data centers, and railway communication stations. It is also suitable for satellite ground stations, broadcast transmitters, and industrial private networks. The dual battery group configuration supports sites requiring zero-interruption backup.
Common deployments include 5G DU and RU power at large macro sites, BRAS and BNG platforms in central offices, and video headend equipment at cable operators. The plant also powers large enterprise IT rooms with hundreds of network switches and servers. The dual battery groups allow one string to be serviced while the other carries the load, eliminating planned downtime.
Advantages and Features
96% efficiency cuts energy consumption by up to 40% compared with phase-controlled systems. Modular design allows N+1 redundancy and future expansion. Web-based management eliminates need for on-site visits for routine configuration. Redundant fans ensure cooling continues even if one fan fails. Branch fuse monitoring helps identify fault circuits instantly. The cabinet integrates AC, rectifier, and DC functions, reducing installation time and cable length.
The controller web HMI provides single-line diagrams, power flow visualization, and alarm dashboards. The event log stores up to 10,000 records with timestamps. The system supports automatic generator start signaling, coordinating with the site backup generator. Branch current monitoring enables load analytics, helping operators right-size future capacity. The cabinet also includes ground fault detection on the DC bus.
Installation and Maintenance Recommendations
Install on a level floor with adequate ventilation. Connect AC via dedicated breaker with upstream surge protection. Place battery strings in a separate vented cabinet. Configure charge parameters per battery manufacturer. Test dual battery groups under load. Integrate with NOC before cutover. Schedule quarterly battery tests and annual thermal imaging. Keep spare rectifiers and fuses on site. Document all configuration changes.
Price
From $5,200 per set. Contact +86 13922289957 for project quotation.