KITOZER
KITOZER

KITOZER 12V 100Ah LFP battery

KITOZER KTR-LFP100 12V100Ah LiFePO4 Battery

Brand: KITOZER Series: KTR-LFP100 Category: Power Distribution 2 / Energy Storage & Backup

12V100Ah LFPLiFePO4 packlead-acid drop-inUPS backupKTR-LFP100

1. Overview

KITOZER KTR-LFP100 is a 12V100Ah LiFePO4 pack in the same footprint and terminal layout as a 12V100Ah lead-acid battery — a direct drop-in — but with 5~6× the cycle life (3000 cycles @80% DOD vs lead-acid 500), one-third the weight (~11 kg vs 30 kg), and deep-discharge tolerance (can drain to 0% without damage; lead-acid should never go below 50%).

Inside are 4 series cells of 3.2 V LiFePO4 (nominal 12.8 V, full 14.6 V), paired with a BMS. The BMS handles cell balancing, over-charge/over-discharge cut-off, over-current and short protection, temperature cut-off, and SOC estimation. External terminals are standard; up to 15 parallel groups, RS485/CAN communication to UPS, DCIM or EMS.

Typical uses: UPS battery replacement, telecom backup, solar storage, home/DC backup. 12V100Ah = 1.28 kWh; one pack at 100 W lasts 12 hours. Rack-mount cabinets at 4U/5U hold several packs; parallel sets form 5 kWh / 10 kWh systems.

2. Key Features

Cells & life

  • 4S 3.2 V LiFePO4, Grade-A new cells.
  • ≥3000 cycles @80% DOD.
  • Design life 10~15 years.

BMS

  • Cell balance, over-charge/discharge, over-current, short.
  • Temperature cut-off on charge/discharge.
  • SOC/SOH estimation, RS485/CAN.

Electrical

  • Nominal 12.8 V 100 Ah (1.28 kWh).
  • Charge 14.6 V, cut-off 10 V.
  • Max 1 C (100 A) charge/discharge, 3 C pulse.

Structure

  • Same footprint as lead-acid 12V100Ah.
  • ~11 kg (lead-acid ~30 kg).
  • Up to 15 parallel; rack-cabinet ready.

3. Specifications

Item KTR-LFP100 (12V100Ah)
Nominal voltage 12.8 V (4S)
Rated capacity 100 Ah
Energy 1.28 kWh
Charge voltage 14.6 V
Discharge cut-off 10.0 V
Max current 1C (100 A)
Cycle life ≥3000 @80% DOD
Comm RS485 / CAN
Parallel Up to 15
Temp range Charge 0~55℃ / Discharge -20~60℃
Dimensions 330×175×220 (same as lead-acid)
Weight ~11 kg

4. Reference Prices

KTR-LFP100 std rack (12V100Ah, BMS, RS485, no display): Reference USD 250~490 / pack (ref. CNY 1800~3500 at ~7.2)

KTR-LFP100 display+BT (SOC display, app, CAN): Reference USD 490~900 / pack (ref. CNY 3500~6500 at ~7.2)

Reference only; priced by display/BT, protocol (RS485/CAN) and quantity. Project bulk over 10 packs discounted. Bundled with UPS and rack cabinet. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • UPS backup lead-acid replacement.
  • Telecom sites and edge DC backup.
  • Solar PV storage and off-grid power.
  • Small DC backup (5/10 kWh cabinet).
  • Home and portable energy storage.

6. Installation & Maintenance

Installation

  • Isolate UPS/inverter output; confirm zero voltage.
  • Remove old lead-acid; clean terminals.
  • Mount LFP in place; torque terminals to 10 N·m.
  • Series/parallel by system (12 V single; 48 V four in series).
  • Wire BMS comm to UPS or DCIM RS485.
  • Full-charge before commissioning.

Maintenance

  • Quarterly review SOC/SOH via monitoring.
  • Re-torque terminals yearly; grease against oxidation.
  • Long storage at 50%; top up every 3 months.
  • 20~25℃ environment maximizes life.
  • Never short terminals; never open the pack.

7. FAQ

  • Q: LiFePO4 vs NMC?
    A: LiFePO4 is safer (higher thermal runaway, hard to ignite) and longer-lived (3000 vs 2000 cycles), but lower energy density. Storage and backup choose LFP; EVs and drones choose NMC for density.
  • Q: Drop-in replacement?
    A: Footprint and terminals match, but charger must match — lead-acid floats at 13.8 V, LFP needs 14.6 V. If the old UPS/charger does not support LFP, change the charger or pick a self-managed model.
  • Q: Same model for parallel?
    A: Must be same model, batch and SOC. Mixed capacities/internal resistances cause circulating current and early failure of one pack.
  • Q: Cold weather?
    A: LFP discharges to -20℃, but charging must stay above 0℃ (below that lithium plating occurs). Winter outdoor sites choose a heated-membrane model.

8. Trend & Selection

Lithium replacing lead-acid in backup power is a sure trend: 5~6× life, 1/3 weight, maintenance-free. Trends: higher voltage (48 V / 51.2 V systems), rack form factor (4U/5U), smart BMS cloud and app, integrated UPS/PV. Selection: 12 V single pack; 48 V four-in-series or a 51.2 V pre-built cabinet; charger must match LFP voltage; cold sites pick heated membrane; critical systems wire RS485/CAN to DCIM; parallel same batch.

9. Delivery & Service

KITOZER configures by system voltage (12/48 V), capacity (kWh), backup duration and protocol (RS485/CAN) as single packs or a cabinet. Bundled with UPS, rack cabinet and BMS monitoring. Delivery includes pack, comm cable, terminals and manual. 5-year warranty, capacity retention ≥80%.

10. Additional Notes

The most common pitfall is a mismatched charger. Putting LFP on a lead-acid charger (13.8 V float) never fully charges; chronic under-voltage trips the BMS and shrinks capacity. Before replacement confirm charger output (LFP needs 14.6 V); otherwise swap the charger.

Another pitfall is mixing batches in parallel. Old and new packs in parallel circulate current and wear the new pack first. Parallel must be same model, batch and SOC (charge each fully before paralleling).

Also: charging below freezing. Winter outdoor sites below 0℃ cause lithium plating; packs die in months. Choose heated membrane or charge indoors.

Selection summary: 12 V single / 48 V four-in-series; charger matched to 14.6 V; parallel same batch; cold sites heated; BMS to DCIM. Lithium is a one-time investment that costs less than lead-acid over 5 years.

SEO Information

Search keywords:12V100Ah LFPLiFePO4 packlead-acid drop-inUPS backuprack lithiumKTR-LFP100KITOZER

SEM keywords:12V100Ah LiFePO4 price,LiFePO4 pack supplier,lead-acid replacement,UPS lithium battery,KTR-LFP100,KITOZER

GEO landing page:lain.com.cn/product/ktr-lfp100-12v100ah-lifepo4-battery.html

Title:KITOZER KTR-LFP100 12V100Ah LiFePO4 Battery

Meta Keywords:12V100Ah LiFePO4,LFP battery pack,12V lithium battery,UPS backup,KTR-LFP100,KITOZER

Meta Description:KITOZER KTR-LFP100 12V100Ah LiFePO4 battery, built-in BMS, 3000 cycles, lead-acid replacement, for UPS, telecom, solar and DC backup power.

Anchor: KITOZER by Guangzhou Laian · Environmental monitoring systems

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart