1. Overview

The KITOZER KTR-GEL120 is a 12V120Ah deep-cycle GEL battery using valve-regulated lead-acid (VRLA) gelled electrolyte, for backup power in UPS, telecom sites, solar storage and room DC panels. GEL batteries gel the sulfuric-acid electrolyte with fumed silica, so it does not flow, leak or stratify; they can be mounted in any orientation (upright recommended) and run 20-30% longer in deep cycling than plain AGM, with strong deep-discharge recovery—suited to frequent cycling and high heat. Rated 12V, 120Ah (20-hour rate), internal resistance ~10mΩ, with peak discharge matching UPS inrush.

Vs flooded lead-acid, GEL is maintenance-free: no topping-up, no acid mist, safe near equipment. Vs AGM, the gelled electrolyte never stratifies and loses water slowly at 30℃+, suiting 24-hour room float. The KTR-GEL120 uses flame-retardant ABS, a top vent valve that regulates pressure without spilling acid, and M8 tinned-copper bolt terminals for high-current contact without heating. Float design life at 25℃ is 12-15 years; cycle life at 50% DOD is ~1200 cycles. Operating range -15 to +50℃, optimum 20-25℃.

Typical deploy: a 30kVA UPS at 384V DC bus uses 32 series-connected 12V120Ah batteries on a rack beside the UPS; each cell links with 35mm² copper cable, first/last to the UPS DC terminals; the rack includes insulation mats and acid barriers. Parallel strings must match capacity and age. Size battery capacity by UPS DC voltage and backup time (10/30/60 min), choose 12V100/120/150Ah by space, and pick GEL or AGM by temperature. Pair with a cabinet, rack, link cables, insulated tools and a battery monitor.

2. Key Features

Deep-cycle GEL

  • Fumed silica gel.
  • No flow/leak.
  • 1200 cycles @50% DOD.
  • Strong recovery.

Maintenance-free

  • VRLA sealed.
  • No water top-up.
  • No acid mist.
  • Near gear ok.

Long life

  • 12-15yr float @25℃.
  • Slow water loss.
  • FR ABS.
  • Valve regulated.

High discharge

  • 12V120Ah.
  • IR ~10mΩ.
  • M8 tinned terminals.
  • UPS peak.

3. Specifications

项目 KTR-GEL120(12V120Ah胶体) KTR-AGM120(12V120Ah AGM) KTR-GEL150(12V150Ah胶体)
额定电压 12V 12V 12V
额定容量 120Ah(20hr) 120Ah(20hr) 150Ah(20hr)
电解质 胶体GEL AGM玻璃棉 胶体GEL
内阻 约10mΩ 约9mΩ 约8mΩ
循环寿命(DOD50%) 约1200次 约900次 约1300次
浮充寿命(25℃) 12至15年 8至10年 12至15年
端子 M8铜镀铅 M6铜镀铅 M8铜镀铅
工作温度 -15至+50℃ -15至+50℃ -15至+50℃

4. Reference Prices

KTR-GEL120 12V120Ah deep-cycle GEL battery:Reference USD 125 to 250 / unit (ref. CNY 900 to 1800 at ~7.2)

KTR-AGM120 12V120Ah AGM battery:Reference USD 97 to 194 / unit (ref. CNY 700 to 1400 at ~7.2)

KTR-GEL150 12V150Ah deep-cycle GEL battery:Reference USD 153 to 306 / unit (ref. CNY 1100 to 2200 at ~7.2)

Battery rack / link cables / insulation kit:Reference USD 11 to 69 / set (ref. CNY 80 to 500 at ~7.2)

Reference only; varies by capacity, GEL/AGM type, qty and paired rack/cables. Cabinet, battery monitor and insulated tools billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • UPS backup power.
  • Telecom DC sites.
  • Solar PV storage.
  • Room DC panels.
  • Frequent deep cycling.

6. Installation & Maintenance

Installation

  • Level the battery rack.
  • Upright on insulation mats.
  • Series-link with 35mm² copper.
  • Torque bolts per manual.
  • First/last to UPS DC.
  • Measure OCV before charge.

Maintenance

  • Quarterly float-voltage check.
  • Annual IR/capacity test.
  • Clean/anti-oxidize terminals.
  • Check rack for dust/leak.
  • Keep 20-25℃.
  • Replace weak cells.

7. FAQ

  • Q: GEL or AGM?
    A: High heat, frequent deep cycles and long life choose GEL (KTR-GEL120); room temp, shallow cycling and cost-sensitive choose AGM. 24h room float at elevated heat prefers GEL.
  • Q: Can I mix old and new batteries?
    A: No. Mismatched internal resistance and capacity drag the whole string down to the weakest cell. Replace the entire string from the same batch and age.
  • Q: What if a battery bulges?
    A: Bulging means overcharge or heat-induced water loss—take it offline immediately. Check UPS float voltage and room temperature, or new cells will bulge too.
  • Q: How to estimate backup time?
    A: Backup ≈ capacity(Ah) × DC bus voltage × efficiency ÷ load(kW). Keep 20% margin; verify with a discharge test.

8. Trend & Selection

Datacenter UPS moves to long runtime and high reliability; GEL batteries with long hot-life and deep-cycle behavior dominate medium/large backup. Size series count by UPS DC voltage; choose 100/120/150Ah by runtime; pick GEL for hot rooms; use same-batch strings; add a battery monitor for IR/voltage; inspect quarterly and test annually. Batteries are the heart of the UPS—without them the UPS is a dummy load.

9. Delivery & Service

KITOZER supplies battery packages: based on UPS DC voltage and runtime we recommend 12V100/120/150Ah GEL counts plus racks, link cables, insulated tools and a battery monitor. Delivery includes cells, bolts and manual; bulk projects include install guidance and initial charge/discharge test. Bulging, leaking or out-of-spec capacity under warranty is replaced free.

10. Additional Notes

The common mistake is under-torqued terminals. Loose terminals raise contact resistance, overheat at high discharge and can weld. Torque per manual (M8 ~8-10N·m) and re-torque once.

Another pitfall is a non-insulated rack. A 384V DC string is exposed; insulation mats between cells and rack prevent shorting if a case cracks. Use insulated gloves and tools.

Selection summary: 12V120Ah GEL, 1200 cycles @50% DOD, 12-15yr float, M8 terminals, series strings for UPS, quarterly inspection. The KTR-GEL120 keeps the UPS reliable when mains fails.

SEO Information

Search keywords:GEL battery12V120Ah batterydeep-cycle batteryUPS batteryroom batteryKTR-GEL120KITOZER

SEM keywords:[GEL battery price,12V120Ah battery,deep-cycle battery supplier,UPS backup battery,KTR-GEL120,KITOZER]

GEO landing page:lain.com.cn/product/ktr-gel120-12v120ah-deep-cycle-gel-battery.html

Title:KITOZER KTR-GEL120 12V120Ah Deep-cycle GEL Battery

Meta Keywords:GEL battery,12V120Ah battery,deep-cycle battery,UPS battery,room battery,KTR-GEL120,KITOZER

Meta Description:KITOZER KTR-GEL120 12V120Ah deep-cycle GEL battery, 1200 cycles @50% DOD, 12-15yr float life, for UPS backup.

Anchor: KITOZER · Power Distribution

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart