KITOZER 2V 200Ah gel battery

KITOZER KTR-GEL200 2V200Ah Deep-Cycle Gel Battery

Brand: KITOZER Series: KTR-GEL200 Category: Power Distribution / Standby Battery

2V200Ahgel batterydeep-cycleVRLA sealedUPS standbyKTR-GEL200

1. Overview

KITOZER KTR-GEL200 is a 2V200Ah deep-cycle gel valve-regulated lead-acid battery (VRLA). The sulfuric acid electrolyte is gelled, making it maintenance-free, leak-proof and mountable in any orientation. 2V is the nominal voltage of a single cell, and 200Ah is the capacity at the standard discharge rate. In service, many 2V cells are series-connected into 24V, 48V, 120V or 240V DC buses feeding UPS or DC panels as standby power during mains outages. A room UPS battery bank is usually dozens of series-connected 2V cells — the last guarantee of power continuity.

Gel batteries (GEL), compared with absorbent-glass-mat (AGM), have gelled electrolyte that resists stratification and water loss, with better deep-cycle performance and less capacity fade over repeated charge/discharge. The deep-cycle design means the battery can be discharged deeply (50%~80% depth) without damage, unlike starting batteries that tolerate only shallow discharge. KTR-GEL200 uses plate grids and a sealed valve, needing no water topping in normal use, with a float design life of 10~12 years at 25 C — a common standby battery in data centers, telecom sites and PV storage.

In power distribution, the battery bank works with the UPS or rectifier panel: when mains is healthy, the UPS charger floats the battery at full charge; when mains fails, the battery discharges through the inverter to keep the load up. 2V200Ah cells are moderate in size, high in capacity and flexible in series, making them the mainstream for mid-to-large UPS banks. A 240V bank needs 120 series-connected 2V cells at 200Ah, supporting 15~30 minutes at full load depending on UPS power and battery efficiency.

2. Key Features

Gel electrolyte

  • Gelled sulfuric acid, no stratification, no leakage.
  • Slow water loss, long float life.
  • Excellent deep-cycle performance.

2V200Ah rating

  • 2V per cell, 200Ah (C10).
  • Flexible series to any DC voltage.
  • Strong high-current discharge.

Valve-regulated sealed

  • Sealed VRLA, maintenance-free.
  • No water topping in normal use.
  • Mount in any orientation.

Long-life design

  • 10~12 year float design life (25 C).
  • Corrosion-resistant grid alloy.
  • Low self-discharge.

3. Specifications

Item KTR-GEL200 (2V200Ah) KTR-GEL100 (2V100Ah) KTR-GEL300 (2V300Ah)
Nominal voltage 2V 2V 2V
Rated capacity (C10) 200Ah 100Ah 300Ah
Weight (kg) ≈12.5 ≈6.8 ≈18.5
Float voltage (25 C) 2.25~2.30V 2.25~2.30V 2.25~2.30V
Equalize voltage (25 C) 2.30~2.35V 2.30~2.35V 2.30~2.35V
Self-discharge (month) ≤3% ≤3% ≤3%
Float design life 10~12 years 10~12 years 10~12 years
Mounting Battery rack/cabinet Battery rack/cabinet Battery rack/cabinet

4. Reference Prices

KTR-GEL200 2V200Ah gel battery (VRLA sealed, deep-cycle, C10): Reference USD 53~81 / cell (ref. CNY 380~580 at ~7.2)

KTR-GEL100 2V100Ah gel battery (smaller, for cabinets): Reference USD 31~50 / cell (ref. CNY 220~360 at ~7.2)

KTR-GEL300 2V300Ah gel battery (high capacity, long backup): Reference USD 78~119 / cell (ref. CNY 560~860 at ~7.2)

Reference only; priced by capacity, quantity and series count; rack, inter-cell connectors and monitoring wires excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • UPS battery banks.
  • DC panel and telecom standby.
  • Off-grid PV storage.
  • Data center battery rooms.
  • Fire and emergency lighting backup.

6. Installation & Maintenance

Installation

  • Design rack/cabinet by load rating and ventilation.
  • Stand cells upright; series-connect connectors by polarity.
  • Torque per manual — loose overheats, overtight cracks terminals.
  • Connect bank to UPS DC bus: positive first, then negative.
  • Keep ambient at 20~25 C for best life.
  • BMS/monitoring wires sample per-cell voltage and temp.

Maintenance

  • Measure per-cell float voltage; address laggards promptly.
  • Ventilate the battery room; keep under 30 C.
  • Check connectors for looseness and oxidation.
  • Run a verification discharge test yearly.
  • Track self-discharge and capacity fade trends.

7. FAQ

  • Q: Gel vs AGM?
    A: Gel is better for deep cycling, longer life and overcharge tolerance, at slightly higher upfront cost; AGM handles high-current discharge and is cheaper. For UPS standby, gel lasts longer; choose gel for frequent outages and deep discharge.
  • Q: How to make 48V from 2V cells?
    A: Series to step up: 24× 2V in series = 48V. Series means positive-to-negative, not parallel; capacity stays 200Ah while voltages add.
  • Q: How long do they last?
    A: 10~12 year float design life at 25 C, but actual life depends on temperature, depth of discharge and charge quality. Every 10 C above halves life. The battery room must be temperature-controlled.
  • Q: Do I add water?
    A: No — a VRLA gel battery is maintenance-free and needs no water. If the case bulges or leaks, the cell has failed: replace it, do not add water.

8. Trend & Selection

Standby power is moving from lead-acid to lithium (LFP), but 2V gel lead-acid remains widely used in data centers and telecom for maturity, safety and low cost. Lithium wins on weight, space and cycle life but costs more upfront. Choose series count by UPS DC voltage; choose capacity (200Ah/300Ah) by backup time; pick gel for hot sites; add cell monitoring for important rooms; never mix old and new cells; commission with a charge/discharge break-in after install.

9. Delivery & Service

KITOZER supplies KTR-GEL 2V gel batteries in volume, configured by bank voltage and capacity. We provide rack connection plans and monitoring guidance. Delivery includes battery body, inter-cell connectors, manual and certificate. Warranty covers under-capacity and case leakage.

10. Additional Notes

The common pitfall is thermal runaway. If the battery room has no air conditioning in summer and exceeds 30 C, battery life shrinks fast, accelerating water loss and plate corrosion. Many room batteries die by year five not from poor quality but from long-term high temperature. The battery room must be independently temperature-controlled around 25 C.

Another pitfall is mixing old and new cells. Adding a few new cells to a bank of old cells: the old ones have higher internal resistance, charge less and discharge first, dragging down the whole bank. When replacing, swap the whole bank, not single cells. Torque the inter-cell connectors per the manual — loose contacts overheat, overtight cracked terminals.

Selection summary: 2V200Ah gel deep-cycle; series to the required voltage; keep the battery room at 25 C; monitor per-cell float voltage; verify-discharge yearly; replace as a whole bank; torque connectors. The battery is the UPS heart — a healthy heart keeps you calm through mains outages.

SEO Information

Search keywords:2V200Ah geldeep-cycleUPS batteryVRLA sealedstandby powerKTR-GEL200KITOZER

SEM keywords:2V200Ah gel battery price,deep-cycle battery supplier,UPS standby battery,KTR-GEL200

GEO landing page:lain.com.cn/product/ktr-gel200-2v200ah-gel-battery.html

Title:KITOZER KTR-GEL200 2V200Ah Deep-Cycle Gel Battery UPS

Meta Keywords:[‘2V200Ah gel battery,deep-cycle battery,VRLA battery,UPS battery,standby power battery,KTR-GEL200,KITOZER’]

Meta Description:KITOZER KTR-GEL200 2V200Ah deep-cycle gel battery, valve-regulated sealed, long-life design for UPS and DC bus standby.