KITOZER 48V 100A Communication Power System For Macro Sites

The KITOZER 48V 100A communication power system is a mid-range modular DC power plant engineered to power multi-sector 4G and 5G macro base stations, central radio units, and transmission equipment in urban and suburban sites. With up to ten hot-swappable rectifier slots and a sophisticated monitoring controller, the system delivers scalable, redundant, and remotely manageable power that telecom operators require for continuous network availability.

Product Overview

The plant combines an AC distribution section, a bay of 48V rectifier modules, a battery connection compartment, and a fused DC output distribution panel. The monitoring unit continuously measures AC input, DC bus voltage, load current, battery current, and module temperatures. It supports N plus N redundancy so operators can tolerate multiple module failures. The controller logs thousands of alarm events and reports them over Ethernet, RS485, or dry contacts to the network operations center.

Technical Specifications

Input supports single phase or three phase 380 VAC, with wide tolerance 304 to 456 VAC. Rated DC output is 48V at 100A continuous, adjustable 42 to 58V. Each 50A rectifier module delivers 3000W with efficiency up to 96 percent and power factor above 0.99. Total harmonic distortion is below 5 percent. Voltage regulation is plus or minus 0.5 percent, and peak to peak ripple is under 150 mV. Battery management supports lead-acid and lithium chemistry with programmable charge curves, temperature compensation, and battery test scheduling. Operating range is minus 20 to plus 55 degrees Celsius. Protection includes DC overvoltage, output short circuit, module overtemperature, and battery reverse connection.

Applications

This 100A plant is the standard choice for three-sector macro sites carrying 4G LTE and 5G NR radio units, baseband units, microwave backhaul, and fiber transmission equipment. It also serves satellite earth stations, enterprise central offices, power substation communication racks, and university campus communication equipment rooms. The 19 inch rack mounting fits inside standard outdoor cabinets or indoor equipment bays.

Advantages and Features

High efficiency rectifiers cut cooling load and reduce energy consumption. The modular design allows pay-as-you-grow capacity expansion without replacing the bay. Remote monitoring supports proactive maintenance, reducing truck rolls. The wide AC input range tolerates weak grid conditions and generator fluctuations. Lithium battery compatibility enables longer service life and higher depth of discharge for hybrid solar sites. Front-access cabling simplifies installation in cramped cabinets.

Installation and Maintenance

Mount the bay in a vibration-free rack, bond the protective earth first, and route AC and battery cables through the lower gland plate. Configure the number of paralleled modules and set battery charge parameters through the web interface. Verify load sharing between modules by measuring current on each output. Conduct a monthly battery discharge test during low traffic hours. Clean inlet filters every six months, torque DC terminals annually, and upgrade monitoring firmware only during planned maintenance windows. Keep ambient temperature stable to maximize battery life.

Price

From $1,680 per set, including three rectifier modules, monitoring unit, and DC distribution. Contact the sales team for N plus one redundancy pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com