Table of Contents
ToggleProduct Overview
The KITOZER 48V/200A communication power system is a high-capacity DC power plant engineered for large central offices, multi-service telecom nodes, and 5G core equipment rooms. It supports up to twenty 48V/10A or ten 48V/20A rectifier modules in parallel, delivering 200A continuous 48V output with full N+N redundancy. The system controller features dual Ethernet ports for redundant network connectivity, supporting both local LCD control and remote SNMP/Modbus TCP management. With integrated AC and DC distribution, lightning protection, and environmental monitoring, this plant forms a complete turnkey power solution for demanding telecom environments.
The dual battery group configuration allows operators to service one battery string while the other carries the load, eliminating planned downtime for battery maintenance. The controller logs every power quality event, including voltage sags, swells, and transfer operations, providing data for energy audits and compliance reporting. The plant is designed for 20-year service life with modular replacement of wear components such as fans and capacitors.
Technical Specifications
Input: 380V three phase four wire, 304-456V AC, 50/60Hz. Output: 42-58V DC, rated 48V/200A. Rectifier modules: 48V/20A high-efficiency, up to 10 modules. Efficiency: up to 96.5%. Power factor: greater than 0.99. THDi: less than 3%. AC distribution: main breaker with surge protection, up to 6 branch feeders. DC distribution: up to 64 branch circuits with fuse monitoring. Battery support: two independent battery groups for dual-feed redundancy. Controller: dual network ports, SD card event logging, web HMI. Protection: AC surge class C, DC surge, reverse polarity, overvoltage, overcurrent. Operating temperature: -5C to +45C. Cooling: redundant fans. Cabinet: 42U, 800mm x 600mm x 2000mm. Weight: approximately 350kg. KITOZER, 5-year warranty.
Application Scenarios
This 200A plant is deployed in carrier central offices, 5G core network equipment rooms, broadband remote access servers, optical transport nodes, and large enterprise communication rooms supporting hundreds of users. It also powers long-haul transmission equipment, telecom infrastructure in data centers, and emergency response communication centers. The dual battery group configuration suits sites where backup reliability is mission-critical, such as financial back-offices and government communication nodes.
Typical loads include 5G core network functions, IMS application servers, BRAS and BNG platforms, DWDM transmission systems, and large VoIP gateways. The plant is also used for data center telecom wings that require 48V power for network switches and routers. The dual battery groups ensure that even during extended utility outages, the load remains powered without manual intervention.
Advantages and Features
The system offers industry-leading efficiency above 96.5%, reducing cooling costs and carbon footprint. Dual battery groups allow maintenance of one battery string while the other carries the load, enabling true 24/7 uptime. The controller supports automatic generator start signaling, load shedding priority, and scheduled battery tests without manual intervention. Redundant network ports prevent single points of failure in remote monitoring. The modular architecture scales from 50A to 200A without replacing the cabinet. Built-in surge protection on AC and DC sides meets IEC 61643 requirements. Front-access wiring simplifies installation in corridor-style equipment rooms.
The controller web HMI provides role-based access control, allowing operators, maintainers, and administrators different permission levels. The system supports REST API integration for advanced DCIM platforms. Branch fuse monitoring helps locate fault circuits within seconds. The redundant fan design ensures cooling continues even if one fan fails. The plant also includes ground fault detection on the DC bus, helping identify insulation issues before they cause outages.
Installation and Maintenance Recommendations
Install on a reinforced floor with load rating above 500kg per cabinet. Ensure adequate ventilation clearance of 800mm on both sides. Connect AC feed via a dedicated three-phase breaker with upstream transformer protection. Configure dual battery strings with separate fuses per group. Calibrate current and voltage sensors during commissioning. Integrate with the site BMS or DCIM platform before handover. Schedule monthly alarm log reviews, quarterly battery capacity tests, and annual infrared thermography. Keep spare rectifiers and fuses in a locked cabinet. Firmware updates should be performed during maintenance windows with rollback plan.
KITOZER Quality Assurance
Every KITOZER product is manufactured in an ISO 9001 certified facility and undergoes rigorous factory testing before shipment. KITOZER provides 24/7 technical support via phone, WeChat, and WhatsApp, with remote diagnostics available through built-in communication interfaces. Spare parts are stocked in regional warehouses for next-day delivery. The warranty covers both parts and labor, demonstrating confidence in product reliability. Documentation including test reports, installation manuals, and CAD drawings is provided with every order. KITOZER also offers on-site commissioning support and training for large deployments, ensuring operators can maintain the system independently. The brand commitment to quality is reflected in the low field failure rate and high customer satisfaction across thousands of installed sites worldwide.
KITOZER has supplied power solutions to telecom operators, enterprise data centers, and industrial customers across more than 50 countries. The product line is designed and manufactured to meet international standards including CE, IEC, and UL certification. KITOZER engineering works closely with customers to customize solutions for specific site conditions, whether that means extreme temperature ranges, high humidity, dusty environments, or limited space. The company maintains a global partner network that provides local sales, installation, and after-sales support. With continuous investment in research and development, KITOZER products incorporate the latest efficiency improvements and digital management features.
KITOZER welcomes customization requests including modified voltage ranges, special communication protocols, custom cabinet dimensions, and branding requirements. The engineering team can tailor the product to specific site conditions and integration needs. Customers can request samples for testing before bulk orders, and KITOZER provides pre-sales technical consultation free of charge. For large projects, KITOZER offers on-site installation supervision and commissioning support. The company also provides long-term spare parts availability for the entire product lifecycle.