The KITOZER 500 kW open frame diesel generator is a high-capacity standby unit delivering 625 kVA for large industrial plants, data centers, hospitals, and utility substations. Built around a V8 or V12 turbocharged aftercooled diesel engine and a heavy-duty brushless alternator with permanent magnet excitation, the set is designed for long runtime, high motor-starting capacity, and reliable paralleling with neighboring units. The open skid allows engineers to build a tailored acoustic container, fuel farm, and exhaust system to site-specific needs, making it a favorite for EPC contractors.
Table of Contents
ToggleTechnical Specifications
Standby 550 kW (687.5 kVA), prime 500 kW (625 kVA), 400V 50Hz three-phase, power factor 0.8. Engine: V-type, water-cooled, turbocharged, aftercooled, electronic unit injector, 1500 rpm. Alternator: brushless, PMG, AVR with droop sharing, class H, IP23, 2/3 pitch. Controller: deep-sea DSE8690 or ComAp IntiGen, color touch screen, Modbus TCP, SNMP, paralleling-ready. Circuit breaker: 1000A air circuit breaker with motor operator. Battery 24V 300Ah dual. Dimensions approximately 4500 x 1600 x 2200 mm, dry weight 9500 to 11000 kg. Fuel consumption at 75 percent load around 110 L per hour.
Key Advantages
The 500 kW set is factory-witness tested under load bank before shipment, with voltage regulation, frequency response, thermal image, and noise report included in the documentation. The engine is equipped with twin fuel filters, twin oil filters, crankcase ventilation with coalescing filter, and a pre-lube pump for cold starts. The alternator winding includes embedded temperature sensors that trip the controller before overheating. Paralleling ports, synchronization lamps, and reverse power protection are pre-wired, so the unit can be tied with up to 8 identical sets for N+1 redundancy.
Applications
Typical deployments include automotive assembly plants, steel rolling mills, cement plants, refineries, and large hospital complexes where loss of power endangers production or safety. Data centers use 500 kW sets as building-level standby, feeding UPS buses through dedicated switchgear. Mining sites, remote oil and gas camps, and island resorts run these units as prime power 24/7, often in parallel with solar arrays. Water and sewage treatment works, district pumping stations, and large warehouse logistics centers also specify this rating for emergency and maintenance backup.
Installation and Maintenance
Foundation must be engineered by a structural consultant, typically a 400 mm reinforced concrete raft with dynamic vibration isolation. Room ventilation requires at least 30000 m3 per hour of inlet and outlet air, with discharge ducted away from the building. Exhaust system uses 8-inch insulated piping, industrial flexible bellows, and an optional spark arrestor and silencer. The fuel farm includes a day tank of at least 1000 L, an external storage tank sized for 8 to 24 hours, leak detection, and double-walled piping in regulated areas.
Maintenance intervals: engine oil and filter every 250 hours, fuel filter every 500 hours, coolant every 2 years, valve adjustment every 3000 hours, major overhaul around 24000 to 30000 hours depending on engine. Quarterly load bank tests and annual infrared thermography of electrical connections are recommended. KITOZER provides a 24/7 hotline, spare parts stocking program, and on-site commissioning support for this class of generator.
Price
From $72,000 per unit for the 500 kW open frame set. Contact KITOZER for engine brand options, alternator selection, paralleling kit, and CIF pricing. Tel/WeChat: +86 13922289957.