The KITOZER 5G base station cabinet is a pre-integrated outdoor enclosure that houses radio unit power, baseband processing, backup battery, and thermal management for macro and millimeter wave 5G sites. Designed to reduce civil works and on-site installation time, the cabinet delivers 48V DC power to radio units and supports multiple carriers sharing one site. It is engineered for unattended operation in wide temperature ranges and remote locations. Compared with separate power cabinet, radio cabinet, and battery cabinet combinations, the integrated KITOZER cabinet reduces footprint, cable runs, and commissioning labor.
Table of Contents
ToggleProduct Overview
The cabinet combines an equipment bay with rectifiers, DC distribution, monitoring controller, and a battery bay supporting front-access lithium or VRLA strings. A side-mounted outdoor air conditioner or heat exchanger maintains internal temperature, and a separate compartment for surge protection and grounding is included. The cabinet supports pole, wall, or ground mounting and arrives factory-tested and pre-wired. A front LCD HMI displays rectifier status, battery voltage, load current, and alarms, and optional 4G transmits all data to the carrier NOC.
Technical Specifications
Ingress protection IP55. Material 1.5mm galvanized steel, outdoor powder coat, optional 304 stainless. AC input 220VAC or 400V three phase, 32A. Rectifier system: 48V DC, up to 60A capacity, modular with N plus 1 redundancy. Battery: 48V 100Ah lithium pack, expandable to 400Ah. DC output distribution: 12 fused outputs for radio units. Thermal: 1000W outdoor AC, 200W PTC heater. Monitoring: rectifier status, battery state, cabinet temperature, door, via SNMP and 4G. Dimensions 800mm W by 800mm D by 1800mm H. Operating range minus 40 degrees Celsius to plus 55 degrees Celsius. KITOZER 3 year power electronics, 5 year enclosure, 5 year lithium warranty.
Applications
The cabinet supports 5G macro cell sites, street pole small cells, railway communications, broadcast transmitter backup power, rural wireless broadband, coastal microwave sites, and temporary event 5G coverage. It also fits multi-carrier tower sharing where a single power cabinet feeds multiple radio units. The cabinet is commonly deployed along highway corridors and urban arterials where pole space is limited and grid supply is available.
Advantages and Features
Pre-integrated design cuts site deployment time from weeks to days. N plus 1 rectifier redundancy ensures radio uptime even during rectifier service. Lithium battery provides long backup life and high cycle count. Air-conditioned battery bay extends battery service life. 4G remote monitoring supports centralized tower management. The cabinet supports multi-carrier power sharing, reducing duplicate shelters on crowded towers. Wide AC input tolerance handles poor grid quality common at roadside locations.
Installation and Maintenance Recommendations
Mount the cabinet on a concrete pad or steel tower frame with proper earth bonding. Connect AC input with dedicated breaker and surge protection. Verify battery BMS communication and load shedding settings before energizing radio units. Schedule quarterly battery voltage and internal resistance checks. Inspect AC condenser and filter every six months. Test load shedding logic annually. Keep cabinet ventilation clear and inspect door gaskets annually. Coordinate radio power-up sequences with the radio vendor to avoid inrush overload on rectifiers.
Customization and Quality
KITOZER offers 304 stainless, expanded battery bay, higher rectifier capacity, and multi-carrier distribution options. Every cabinet passes a factory rectifier load test, battery charge cycle, and thermal run before shipment. Units ship with wiring diagrams, commissioning guide, and test certificate. Project customers receive power budget support for radio unit count and backup runtime calculation.
Working Principle and Design Detail
The cabinet operates as a sealed thermal and electrical island: incoming AC power passes through the input breaker and surge arrester before reaching the internal distribution bus, while the climate controller continuously compares internal air temperature against the setpoint and switches fans or compressor on demand. The door gasket is compressed by multi-point latches to maintain the rated ingress protection across the full door perimeter, and all cable entries use rated glands so that no unsealed opening remains. Internal cable managers route power, signal, and fiber cables on separate paths to prevent electromagnetic interference and simplify tracing during maintenance. The grounding busbar bonds the cabinet frame, internal equipment chassis, and external surge protection to a single equipotential network, reducing touch voltage risk during fault conditions. This structured design ensures that every field-installed connection remains serviceable for the full service life of the enclosure.
Quality and Certification
Every enclosure is manufactured under a documented quality system that includes incoming material inspection, in-process welding and coating checks, and a final factory acceptance test before shipment. Test records cover insulation resistance, continuity, ingress protection verification, and thermal function. Standard certifications include CE marking where applicable, and the enclosure is constructed from materials that comply with RoHS directives. The cabinet is packaged in foam-lined seaworthy crates suitable for long-haul ocean freight, with desiccant bags to prevent transit condensation. KITOZER supports long-term spare parts availability and offers extended warranty options for mission-critical deployments.
Price
From $3,980 per unit including 60A rectifier and 100Ah lithium battery. Contact KITOZER for multi-carrier and expanded battery options.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com