Table of Contents
ToggleProduct Overview
The KITOZER 63A automatic transfer switch is a compact electromechanical dual-source selector for single-phase critical loads that do not require sub-cycle static switching but must still transfer reliably between utility and generator feeds. Built around a robust change-over contactor with a mechanical interlock that prevents both sources from ever being connected at the same time, the unit automatically moves the load to the emergency source when the preferred supply fails and back to the preferred source when it returns stable for a programmable delay. The controller continuously monitors voltage, frequency, and phase on both feeds, and it uses adjustable transfer and re-transfer timers so that short utility dips do not start the generator unnecessarily and so that brief source flickers do not cause an unnecessary transfer. The 63A rating is sized for small server rooms, retail backup loads, telecom shelters, small medical offices, and standalone generator interfaces, and the unit mounts on a DIN rail or in a wall enclosure for easy integration into small distribution boards.
Technical Specifications
Rating: 63A continuous, single phase 230VAC, 50 or 60Hz. Type: PC class change-over contactor with mechanical and electrical interlock, transfer time 100ms to 250ms typical depending on load. Source monitoring: under voltage, over voltage, under frequency, over frequency, on both feeds. Voltage window programmable 170V to 270V, frequency window 47Hz to 63Hz. Timers: engine start delay, transfer delay, re-transfer delay, and preferred source selection all adjustable on the controller. Control supply: 230VAC from source A or B, optional 24VDC. Communication: RS485 Modbus RTU standard, optional Ethernet Modbus TCP, dry contact outputs for source A live, source B live, transfer position, and fault. Protection: miniature circuit breaker on control circuit, contactor coil surge suppression. Mounting: DIN rail or wall enclosure, IP20, operating 0 to 55 degrees C. Standards: CE, IEC 60947, 5 year warranty.
Application Scenarios
The 63A ATS is the standard interface between a small diesel or gas generator and a single building or shop utility feed. Typical applications include small retail shops, restaurants, convenience stores, and gas stations that need generator backup without manual intervention; small server rooms and branch offices where the UPS covers the 100ms transfer gap but the generator must take over for long outages; telecom and 5G base station shelters where the generator starts automatically on utility loss; small medical and dental clinics that cannot manually flip a switch during a power cut; and security, access control, and fire alarm systems that must ride through to a generator supply. It is also used in single-phase solar plus storage systems to select between grid, generator, and inverter feed.
Key Advantages
The first advantage is simplicity. The unit has no SCR cooling, no fans, and no high-voltage semiconductors, so it is rugged, cheap to maintain, and easy to commission. The mechanical plus electrical interlock guarantees that the two sources can never be paralleled, which is essential when one source is a generator and the other is the utility. Adjustable timers prevent nuisance starts of the generator and nuisance transfers during short dips. Modbus reporting lets the remote operations center see source position, source health, and fault state. The DIN rail mounting fits neatly into standard enclosures. The unit also supports a manual override handle for maintenance and emergency operation. Finally, the 5 year warranty and field-proven contactor design mean low lifetime cost.
Installation and Maintenance Recommendations
Mount in a ventilated, dry enclosure near the main incomer, size upstream breakers to coordinate with the contactor rating, and verify that source A and source B polarity and neutral align. On commissioning, set the engine start delay to match generator cranking time, set transfer delay to let generator voltage stabilize, and set re-transfer delay to keep the generator loaded for a cooling run before returning to utility. Perform a forced transfer test by disconnecting source A and observing the generator start, transfer, and re-transfer sequence. Maintenance is straightforward: inspect contactor contacts annually for pitting, torque power terminals, test the manual override, and read the event log on Modbus. Because the contactor is a wearing part, budget a contactor replacement every 10 years or after a defined number of operations, and keep a spare contactor coil on hand for remote sites. Trend source voltage to catch failing transformers before they cause nuisance starts.
Ordering Information
The 63A ATS is supplied as a DIN rail mounted controller with change-over contactor, or pre-mounted in a wall enclosure ready for field wiring. The standard configuration includes RS485 Modbus RTU, dry contact outputs, and adjustable timers on the front fascia. Optional add-ons include Ethernet Modbus TCP, a 24VDC control supply for telecom shelters, and a generator start output with configurable crank attempts. The unit is CE marked and backed by a five year warranty. Lead time is one to two weeks for standard configurations. KITOZER provides a wiring diagram tailored to the generator model, and the unit can be pre-programmed with site-specific voltage windows and timers before shipment to reduce commissioning time.
Price
From $420 per piece. Contact the factory for Modbus TCP option, generator interface wiring diagram, and custom enclosure. Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com