KITOZER CB ATS: 160A Class CB Automatic Transfer Switch

Product Overview

The KITOZER 160A CB class automatic transfer switch uses two motor-operated molded case circuit breakers with a mechanical interlock, providing both automatic source selection and full overcurrent protection on each source. CB class is preferred where each feed must be independently protected, where downstream fault levels require selective coordination, or where the design engineer wants the ATS to also serve as the incoming protection device. The controller continuously monitors both sources, trips the current source breaker after a programmable delay, closes the alternate source breaker, and logs the event. The mechanical interlock guarantees that both breakers cannot be closed at the same time, eliminating any risk of utility and generator paralleling. A manual handle allows operators to mechanically select either source during maintenance or emergency.

Technical Specifications

Rating: 160A continuous, 400V three phase plus neutral, 50 or 60Hz. Class: CB class IEC 60947-6-1, two motorized MCCBs with mechanical and electrical interlock. Transfer time: 150ms to 300ms typical. Source monitoring: three phase voltage, frequency, unbalance, phase rotation on both feeds. Breaker protection: thermal magnetic or electronic trip, adjustable long time, short time, instantaneous. Voltage window programmable 320V to 460V, frequency 47Hz to 63Hz. Timers: generator start delay, transfer delay, re-transfer delay, preferred source. Control: microprocessor controller with LCD, event log, fault indication. Communication: RS485 Modbus RTU standard, optional Ethernet Modbus TCP, dry contact IO. Mounting: floor or wall cabinet, IP31, operating -5 to 40 degrees C. Standards: CE, IEC 60947, 5 year warranty.

Application Scenarios

The 160A CB ATS is typically used where each source must be independently protected and coordinated. Common applications include medium commercial buildings, industrial process distribution, water and wastewater pump stations, mining site power, and mid-size data halls where the UPS covers the transfer gap. It is also the right choice when the downstream fault level requires selective coordination with upstream breakers, because the electronic trip unit on each MCCB can be tuned to a coordination study. In solar plus storage and microgrid installations, it selects between grid, generator, and inverter feed while providing fault protection on each. In healthcare and education campuses, it feeds life safety and emergency busbars.

Key Advantages

The main advantage is built-in overcurrent protection on each source, which reduces the number of devices in the switchboard and simplifies coordination. The electronic trip unit on each breaker is adjustable, so long time, short time, and instantaneous settings can be tuned to the distribution protection study. The mechanical interlock is physically impossible to defeat, making source paralleling a hardware impossibility. The motorized breakers provide positive open indication, which is useful for maintenance. The controller event log and Modbus reporting give remote visibility. The manual handle allows safe mechanical selection. Because each breaker is a standard MCCB, spare breakers are readily available and field serviceable. The 5 year warranty covers both breakers and control.

Installation and Maintenance Recommendations

Mount on a rigid plinth, size upstream and downstream busbar for 160A, and verify that the upstream main breaker coordinates with the ATS breakers per the protection study. Set trip units to the study values, not defaults. On commissioning, set voltage and frequency windows, set generator start and transfer delays, and force a transfer on each source with real load. Verify the mechanical interlock by attempting to close both breakers manually. Maintenance: inspect breaker contacts annually, torque terminals, test trip unit with primary injection every 2 years, read event log, and exercise motor drive. Keep spare breakers in the same frame size on site. Because CB class breakers wear after high short-circuit events, inspect them after any fault and replace if the manufacturer requires. Trend source voltage and current to catch load growth and source degradation before they cause nuisance trips.

The 160A CB ATS is well suited to sites where selective coordination is required, because the electronic trip units on both breakers can be tuned to the protection study. It is commonly installed ahead of motor control centers, lighting panels, and life safety distribution. The unit can be integrated into a new switchboard or supplied as a standalone wall cabinet. Field technicians appreciate the positive open indication on each breaker, which removes ambiguity during maintenance.

Ordering Information

The 160A CB ATS is supplied as a wall or floor cabinet with two motorized MCCBs pre-mounted and interlocked. The standard controller includes LCD, event log, RS485 Modbus RTU, and adjustable trip units. Optional packages include electronic trip units with communication, Ethernet Modbus TCP, generator start output, and a padlockable manual handle. The cabinet is available IP31 or IP42, and the MCCB brand can be specified to match site standards. Lead time is three to five weeks. KITOZER provides a protection coordination study support, factory test report, and commissioning guidance. The five year warranty covers both breakers and the controller, and spare breaker parts are available from standard distribution.

Price

From $2,480 per piece. Contact the factory for trip unit settings, coordination study support, and Modbus TCP option. Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com