Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

Data Center Integrated Construction

KITOZER Data Center Integrated Construction Quotation List

机房整体建设集成
机房整体建设集成

2. Project Requirement Description

This solution is designed for a standard medium-sized data center environment, with a total construction area of approximately 120㎡, divided into three functional zones: the main equipment room area, power distribution auxiliary area, and monitoring duty area. The project must comply with national Class A data center construction standards, meeting fundamental physical performance requirements including:

  • Dust prevention and static electricity control
  • Fire resistance and flame retardancy
  • Thermal insulation and heat preservation
  • Electromagnetic shielding
  • Waterproofing and moisture resistance
  • Complete infrastructure for data room decoration

The objective is to provide a standardized physical carrier for subsequent electromechanical system deployment.

3. System Composition Introduction

The data center integrated construction system comprises eight major subsystem modules:

  • Ceiling suspension system
  • Wall decoration system
  • Anti-static access floor system
  • Fire-resistant glass partition system
  • Professional lighting system
  • Door and window protection system
  • Lightning protection and grounding system
  • Waterproof cofferdam system

These modules cover the full-range foundational decoration and physical protection requirements across all data center areas.

4. Core Product Specifications & Parameters

4.1 Ceiling Suspension System

  • Specialized micro-perforated metal ceiling panels for data centers
  • Base material: high-quality galvanized steel sheet with electrostatic powder coating
  • Fire resistance rating: Class A
  • Sound absorption coefficient: ≥0.7
  • Thickness: ≥0.8mm
  • Dimensions: 600×600mm
  • Includes light-gauge steel keels, hangers, edge trims, and auxiliary materials

4.2 Wall Decoration System

  • Specialized color steel composite wall panels for data centers
  • Base material: 0.5mm aluminum-zinc coated steel sheet with 12mm fireproof gypsum board backing
  • Polyester spray coating surface
  • Fire resistance rating: Class A
  • Sound insulation: ≥25dB
  • Flatness: ≤0.5mm/m
  • Dust-proof, anti-static, and easy-to-clean characteristics

4.3 Anti-static Access Floor System

  • All-steel seamless anti-static access flooring
  • Steel plate thickness: ≥0.6mm
  • Filled with foamed cement
  • Surface: high-wear-resistant melamine anti-static laminate
  • System resistance: 10⁶~10⁹Ω
  • Fire resistance rating: Class B1
  • Concentrated load: ≥450kg
  • Uniform load: ≥2300kg/㎡
  • Dimensions: 600×600×35mm
  • Includes steel supports, cross beams, and grounding terminals

4.4 Fire-resistant Glass Partition System

  • Cesium-potassium monolithic fire-resistant glass
  • Thickness: ≥12mm
  • Fire endurance: ≥90 minutes
  • Light transmittance: ≥85%
  • Equipped with stainless steel frames and fire-resistant sealant
  • Fire resistance rating: Class A
  • Provides fire separation and visual management functionality

4.5 Professional Lighting System

  • LED grille light panels
  • Dimensions: 600×600mm
  • Power: 36W
  • Color temperature: 5000K
  • Illuminance: ≥500lx
  • Flicker-free, glare value: ≤19
  • Includes emergency lighting fixtures with ≥90 minutes emergency power supply duration

4.6 Lightning Protection and Grounding System

  • Copper busbar grounding network
  • Main grounding busbar: 40×4mm purple copper bar
  • Grounding down-lead: 35mm² multi-strand copper core wire
  • Combined grounding resistance: ≤1Ω
  • Includes equipotential connectors and grounding terminal boxes

5. Core Functions & Features of Products

Physical Protection Function:

  • Constructs a sealed and clean data center environment
  • Isolates external dust, moisture, and noise intrusion
  • Maintains data center cleanliness to Class B standard

Static Electricity Discharge Function:

  • Flooring, walls, and ceiling form a complete static discharge network
  • Rapidly dissipates static electricity generated by equipment operation
  • Prevents electrostatic discharge damage to electronic components

Fire Separation Function:

  • Class A fire-resistant materials separate all functional zones
  • Delays fire spread and ensures evacuation time for personnel and equipment

Environmental Adaptation Function:

  • Thermal insulation layers reduce external temperature fluctuations
  • Decreases air conditioning energy consumption
  • Improves environmental stability

Grounding and Lightning Protection Function:

  • Establishes equipotential grounding system
  • Dissipates lightning surge currents and equipment leakage currents
  • Ensures equipment and personnel safety

6. Core Advantages of The Solution

  • Modular Design: All decorative components are factory-prefabricated and assembled on-site, providing short construction periods with flexible adjustment and disassembly capabilities.
  • Full Class A Fire Resistance: Core decorative materials meet national Class A fire resistance standards, conforming to high fire safety requirements for data centers.
  • Complete Anti-static Chain: Forms a continuous static discharge path from floor to wall to ceiling, delivering stable and durable static control performance.
  • Clean and Low-maintenance: Smooth, dense surfaces resist dust accumulation; routine cleaning and maintenance are convenient with a service life of ≥15 years.
  • Standardized Adaptation: All dimensions conform to data center equipment installation modulus, seamlessly integrating with racks, cable trays, and conduit systems.
  • Performance Exceeds National Standards: Core parameters such as floor loading, wall fire rating, and lighting illuminance exceed national Class B data center standards, satisfying Class A requirements.
  • Integrated Delivery: Full-process control from material production to on-site installation eliminates multi-supplier coordination gaps, ensuring consistent quality.
  • Eco-friendly and Odor-free: All materials meet E0 environmental standards; rooms can be used immediately after installation with no formaldehyde or harmful gas emissions.
  • Future Upgrade Ready: Reserved cable pathways and structural allowances support future capacity expansion and system upgrades.

7. Manufacturer Strength Introduction

KITOZER, represented by Guangzhou Lai’an Intelligent System Development Co., Ltd. , was founded in 2002 and is a certified high-tech enterprise with ISO 9001, ISO 14001, and ISO 45001 certifications. The company operates as a manufacturer with:

  • Production Capacity: Fully automated sheet metal forming lines, electrostatic spray coating lines, and precision cutting equipment, with an annual production capacity of 100,000㎡ of data center decoration materials.
  • Quality Assurance: Core products have passed national authoritative testing for fire resistance, anti-static performance, and environmental compliance.
  • Complete Service: Supports non-standard size customization, on-site measurement and design deepening, doorstep installation, and commissioning as a one-stop service.
  • Industry Experience: The KITOZER brand has over 10 years of experience in the data center construction industry, with products widely applied in government, finance, healthcare, and education sector data center projects.
  • Quality Control: Every product undergoes complete quality inspection before shipment.

8. Detailed Quotation Table

No. Product Name Model & Spec Technical Parameter Qty Unit Unit Price (USD) Total Price (USD) Brand Remark
1 All-steel Seamless Anti-static Access Floor KZR-FB-6035 600×600×35mm, all-steel structure, melamine laminate surface, system resistance 10⁶~10⁹Ω, concentrated load ≥450kg 120 ㎡ 111.00 13320.00 KITOZER Includes supports, cross beams, auxiliary materials
2 Data Center Color Steel Wall Panel KZR-CB-05 0.5mm aluminum-zinc coated steel + 12mm fireproof gypsum board, Class A fire rating, 600mm modulus 180 ㎡ 79.92 14385.60 KITOZER Includes keels, fittings, sealant
3 Micro-perforated Metal Ceiling Panel KZR-DD-6008 600×600mm, 0.8mm galvanized steel sheet, Class A fire rating, sound absorption coefficient ≥0.7 120 ㎡ 53.28 6393.60 KITOZER Includes light-gauge steel keels, hangers, edge trims
4 Cesium-Potassium Fire-resistant Glass Partition KZR-GD-12 12mm monolithic cesium-potassium fire-resistant glass, fire endurance 90min, stainless steel frame 36 ㎡ 199.79 7192.44 KITOZER Includes hardware, fire-resistant sealant
5 LED Grille Light Panel KZR-ZM-36W 600×600mm, 36W, 5000K, illuminance ≥500lx 20 set 53.28 1065.60 KITOZER Includes installation accessories
6 Emergency Lighting Fixture KZR-YJ-3W 3W LED, emergency duration ≥90min, motion sensor 8 set 39.96 319.68 KITOZER Includes battery, mounting bracket
7 Class A Fire Door KZR-FM-1021 1000×2100mm, steel Class A fire door, fire endurance 90min 2 unit 532.78 1065.56 KITOZER Includes lock, door closer, coordinator
8 Purple Copper Main Grounding Busbar KZR-JD-404 40×4mm purple copper bar, total length 30m, with insulators and fasteners 1 set 1775.94 1775.94 KITOZER Includes grounding terminals, connecting strips
9 Equipotential Grounding Terminal Box KZR-DX-8 8-terminal equipotential box, 1.2mm steel sheet enclosure 4 pc 66.60 266.40 KITOZER Includes internal copper bar, wiring terminals
10 Waterproof Cofferdam KZR-FS-10 10cm height cement cofferdam, waterproof coating treatment, surrounding data center perimeter 60 m 44.40 2664.00 KITOZER Includes waterproof mortar, waterproof coating
11 Wall Insulation Layer KZR-BW-20 20mm rubber-plastic insulation cotton, Class B1 fire rating, thermal conductivity ≤0.034W/(m·K) 180 ㎡ 17.76 3196.80 KITOZER Includes adhesive, fixing nails
12 Stainless Steel Skirting KZR-TJ-80 80mm high stainless steel skirting, 1.0mm thickness 60 m 13.32 799.20 KITOZER Includes fixing accessories
13 Installation & Construction Fee KZR-SG-ZT Overall decoration installation, construction, auxiliary materials, waste removal 1 item 6659.76 6659.76 KITOZER Includes labor, machinery, transportation

Total Quotation Price: USD 59490.58

9. Quotation Terms & Conditions

  • Currency: All prices are quoted in USD.
  • Pricing Terms: EXW Guangzhou, China (or as negotiated).
  • Tax: The above quotation excludes tax and freight. For Value-Added Tax (VAT) special invoice, an additional 10% tax point applies; for VAT regular invoice, an additional 3% tax point applies.
  • Payment Terms: 30% deposit / 70% balance before shipment (negotiable).
  • Lead Time: 15-30 working days depending on configuration.
  • Quotation Validity: 30 days from the date of quotation.
  • Shipping: Product transportation uses logistics delivery; freight is to be collected upon arrival (freight collect). Unloading is the responsibility of the buyer upon delivery.
  • Packing: Packing and shipping costs are quoted separately unless otherwise specified.

10. After-sales Service Description

  • Warranty Period: The overall decoration project carries a 3-year warranty. Free repair and replacement will be provided for non-artificial damage during the warranty period.
  • Product Warranty: 12-24 months warranty depending on the product category.
  • Technical Support: Lifetime technical support provided.
  • Spare Parts: Long-term spare parts availability guaranteed.
  • Service Options: Remote troubleshooting and on-site service options are available.

11. Contact & Order Information

To place an order or request further information:

  • Official Website: www.gdlain.com
  • Contact: KITOZER Sales Team
  • Brand: KITOZER

All inquiries will receive a response within 24 hours. Customization, technical consultation, and after-sales support are available through the official website or direct sales channel.

12. SEO Keywords & Tags

KITOZER quotation, data center integrated construction price list, data center construction cost, A-grade data center renovation solution, anti-static access floor installation quotation, data center color steel wall panel price, data center fire-resistant partition, data center grounding system quotation, data center ceiling system price, wholesale data center construction quotation, data center infrastructure building integration, KITOZER data center construction, KITOZER anti-static flooring, data center renovation factory price, data center decoration materials quotation