KITOZER KTR-B2200 Battery (2V 200Ah Deep-Cycle VRLA)

KITOZER KTR-B2200 Battery (2V 200Ah Deep-Cycle VRLA)

Brand: KITOZER Series: KTR-B2200 Category: Power Distribution 2 / UPS Battery

battery2V 200Ahdeep cycleVRLA sealedUPS backup

1. Overview

KITOZER KTR-B2200 is a valve-regulated lead-acid (VRLA) battery, 2 V per cell, 200 Ah rated, designed for UPS backup, DC switchgear and telecom power. On mains failure, the UPS rides on the battery bank until the diesel generator starts and stabilizes (typically a 5~15 minute transfer). The battery bank is the most fragile link in the UPS system — the UPS unit lasts 10 years, but batteries usually need replacement every 3~5 years, and failure is often sudden: one bad cell among 192 collapses the whole string’s backup time.

KTR-B2200 uses AGM (Absorbent Glass Mat) technology: electrolyte is absorbed in the glass-mat separator, non-spill, mountable upright. A 2 V cell means long series strings — a 384 V DC bus needs 192 cells in series. Advantages of large 2 V cells over 12 V blocks: high capacity (200~3000 Ah options), good consistency, long life (10~12 year float design), and per-cell voltage monitoring. Deep-cycle design tolerates repeated deep discharge/recharge for frequent-outage scenarios.

AGM vs gel: AGM has absorbed electrolyte, low internal resistance and strong high-current discharge — ideal for UPS; gel has gelled electrolyte, lower self-discharge and better high-temperature performance, but slightly higher resistance. Data centers mainstream AGM; hot climates may choose gel. KTR-B2200 emphasizes inter-cell connectors and monitoring: after series strings, per-cell voltage imbalance is amplified by the bucket effect, so every cell taps a voltage wire to a battery monitor that tracks per-cell voltage and internal resistance.

2. Key Features

2V large cell

  • Rated 2 V, 200 Ah (C10, 25℃).
  • Design float life 10~12 years (25℃).
  • Deep-cycle ≥1200 cycles (50% DOD).

AGM VRLA

  • AGM glass mat, absorbed non-flowing electrolyte.
  • Valve-regulated sealed, no spill, no water topping.
  • Starved-electrolyte with internal oxygen recombination, low hydrogen evolution.

Discharge performance

  • 10-min discharge current up to 1000 A (short-time).
  • Operating temp -15~+50℃ (optimum 20~25℃).
  • Self-discharge ≤3%/month (25℃).

Monitoring & safety

  • Voltage tap on each cell to battery monitor.
  • Safety vent opens on over-pressure.
  • Flame-retardant case (UL94-V0), short-proof terminal cover.

3. Specifications

Item KTR-B2200-100 KTR-B2200-200 KTR-B2200-300
Rated voltage 2 V 2 V 2 V
Capacity (C10,25℃) 100 Ah 200 Ah 300 Ah
Float design life 10 years 12 years 12 years
Float voltage 2.275 V/cell 2.275 V/cell 2.275 V/cell
Equalize voltage 2.35 V/cell 2.35 V/cell 2.35 V/cell
Self-discharge ≤3%/mo ≤3%/mo ≤3%/mo
Dimensions (approx) 171×71×208 mm 171×106×208 mm 207×106×215 mm
Weight (approx) 6.5 kg 12.5 kg 18 kg
Internal resistance ≤0.5 mΩ ≤0.3 mΩ ≤0.25 mΩ

4. Reference Prices

KTR-B2200-100 2V100Ah AGM battery (10-year float, with connector bars): Reference USD 25~56 / cell (ref. CNY 180~400 at ~7.2)

KTR-B2200-200/300 2V200Ah/300Ah deep-cycle (12-year float, with connectors and voltage taps): Reference USD 63~153 / cell (ref. CNY 450~1,100 at ~7.2)

Reference only; final quote depends on capacity, quantity, and whether racks/cabinets/monitor included. Volume tier discounts; UPS unit and generator excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data center UPS backup battery strings.
  • Telecom base station -48V battery strings.
  • Power DC switchgear and substation operating supply.
  • Solar/wind energy storage deep-cycle banks.
  • Fire emergency power (EPS) backup.

6. Installation & Maintenance

Installation

  • Position battery racks by designed load, leave ventilation gaps.
  • Stand cells upright, series connectors per diagram (mind polarity).
  • Torque connector bars to spec (8~12 N·m).
  • Tap each cell to the battery monitor.
  • String output to UPS DC bus.
  • After install, run a capacity test (discharge 30~50%).

Maintenance

  • Monitor per-cell voltage (alarm if deviation >0.05 V).
  • Monthly per-cell voltage and ambient temp (25℃ ideal).
  • Annual capacity test to verify real capacity.
  • Re-torque connector bars yearly (thermal cycling loosens).
  • Replace whole string at 80% design life or below 80% rated capacity.

7. FAQ

  • Q: How long do batteries last?
    A: 10~12 years float at 25℃. But real halls run 25~30℃; every 10℃ rise halves life, so actual service is 5~8 years. Periodic capacity test is the only reliable way to judge fade.
  • Q: Why replace the whole string, not one cell?
    A: A series string’s capacity is set by the weakest cell (bucket effect). A new cell mismatched with old cells causes over-charge on the new and under-charge on old, accelerating failure. Replace same-batch same-brand as a whole string.
  • Q: Why ventilate the battery room?
    A: Lead-acid batteries emit hydrogen during charging; accumulation to 4% is explosive. Battery rooms need mechanical exhaust (≥12 ACH) with top vents — paired with the KTR-EF exhaust system.
  • Q: 2V vs 12V cells?
    A: Large UPS (>200 kVA) uses 2V large cells for consistency, long life and online monitoring; small UPS (<10 kVA) uses 12V blocks for compact cheapness. Data center large UPS mainstream is 2V.

8. Trend & Selection

Backup power evolves from “VRLA monopoly” to “lithium + lead-acid coexistence”: LiFePO4 is smaller, longer-life (10~15 years), higher cycle count, but higher upfront cost and needs dedicated BMS and fire protection. VRLA remains mainstream — mature, cheap. The trend is full-lifecycle monitoring (per-cell voltage, resistance, temperature to the cloud) for predictive maintenance. Choose series count by UPS DC bus (384V = 192 cells); size capacity by backup time (15 min → 200 Ah, 30 min → 300 Ah+); choose gel or enhanced ventilation in hot climates; battery monitor mandatory; buy whole string same batch; design battery room ventilation for hydrogen.

9. Delivery & Service

KITOZER provides battery string selection: based on UPS power, DC bus voltage, backup time and room space, we calculate capacity and series count, and configure racks, connectors, monitor and ventilation. We produce the battery layout (rack arrangement, series diagram, monitor wiring, exhaust design). Bundled with UPS units, battery cabinets and exhaust systems. Delivery includes cells, connector bars, voltage tap wires and racks/cabinets. Warranty covers capacity-test guidance and fade assessment.

10. Additional Notes

The most common pitfall is “installing batteries but skipping the discharge test”. Acceptance checks open-circuit voltage and ships; when mains actually fails, backup time is 1/3 of design — a cell has internal sulfation short, normal on no-load but collapses under load. Acceptance must run a real capacity test and verify backup time.

Another pitfall: “connectors not torqued”. Contractors finger-tighten the bars without a torque wrench. After a year of thermal cycling, loose bars heat up and may arc. Bars must be torqued to spec (8~12 N·m) and re-torqued yearly.

Selection summary: series count by DC bus; capacity by backup time; 10~12 year float at 25℃; battery monitor mandatory; whole-string same-batch replacement; battery-room hydrogen exhaust; acceptance capacity test. The battery is the UPS’s heart — on mains failure it’s all that holds up the load; a weak heart makes the UPS a decoration.