Table of Contents
ToggleKITOZER KTR-BAT-V100 VRLA AGM Battery (12V100Ah)
Brand: KITOZER Series: KTR-BAT-V100 Category: Battery / VRLA Lead-Acid
12V100AhAGM10-yr floatmaintenance-freeKTR-BAT-V100
1. Overview
The KITOZER KTR-BAT-V100 is a 12V100Ah valve-regulated lead-acid (VRLA AGM) battery used as backup for UPS systems, DC panels, telecom base stations and solar storage. It floats on standby during normal mains and discharges instantly when mains fails, keeping servers and network gear online. Lead-acid batteries are the most-used backup energy storage in data centers; each 12V100Ah unit weighs about 30 kg and is series-connected into 48V or 384V banks.
KTR-BAT-V100 uses AGM (absorbed glass mat) separators; electrolyte is absorbed in the glass mat and does not flow. The valve-regulated seal recombines overcharge oxygen at the negative plate (no acid mist), and it is maintenance-free (no watering). Float design life 10 years at 25 C; cycle life about 1200 at 50% depth of discharge. Nominal 12V, rated 100Ah (20-hour rate), max discharge 1000A (5 s), operating temp -15 to +50 C. ABS flame-retardant case, about 330x173x214 mm including terminals, M8 copper terminals.
Typical uses: small-to-medium UPS backup (a 6 kVA UPS uses 20 x 12V100Ah in series for 240V); telecom -48V power (4 x 12V in series for 48V); power DC panels (closing and control supply); off-grid solar storage (charge by day, discharge by night); fire EPS. KTR-BAT-V100 is the standard industrial backup cell.
2. Key Features
AGM sealed
- Absorbed glass mat separator.
- Immobilized electrolyte.
- Valve-regulated, no acid spray.
- Maintenance-free.
Long life
- 10-year float design (25 C).
- 1200 cycles (50% DOD).
- Starved-electrolyte design.
- Corrosion-resistant grid alloy.
Electrical
- 12V100Ah (20 hr).
- Max discharge 1000A (5 s).
- Internal resistance 3.5 mohm.
- Self-discharge 3%/month.
Safety
- ABS flame-retardant case.
- Pressure relief valve.
- M8 copper terminals.
- Mount any orientation (except inverted).
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-BAT-V100 |
| Nominal voltage | 12V |
| Rated capacity | 100Ah (20 hr, 25 C) |
| Reserve capacity | about 180 min (25 A discharge) |
| Float voltage | 13.5 to 13.8V (25 C) |
| Equalize voltage | 14.4 to 14.7V (25 C) |
| Max discharge | 1000A (5 s) |
| Internal resistance | about 3.5 mohm |
| Self-discharge | 3%/month (25 C, storage) |
| Float design life | 10 years (25 C) |
| Cycle life | about 1200 (50% DOD) |
| Operating temp | -15 to +50 C discharge / -20 to +50 charge |
| Case | ABS flame-retardant |
| Dimensions | about 330x173x214 mm |
| Weight | about 30 kg |
| Terminal | M8 copper |
4. Reference Prices
KTR-BAT-V100 12V100Ah AGM: Ref. USD 94~132 / pc (CNY 680~950 at 7.2)
KTR-BAT-V65 12V65Ah: Ref. USD 58~81 / pc (CNY 420~580 at 7.2)
KTR-BAT-V200 12V200Ah: Ref. USD 174~243 / pc (CNY 1250~1750 at 7.2)
KTR-BAT-G100 12V100Ah gel (deep cycle): Ref. USD 118~167 / pc (CNY 850~1200 at 7.2)
Battery cabinet (holds 20 x 100Ah): Ref. USD 111~208 / pc (CNY 800~1500 at 7.2)
Inter-cell connector (tinned copper): Ref. USD 2~4 / pc (CNY 15~30 at 7.2)
Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Small-medium UPS backup.
- Telecom -48V battery bank.
- Power DC panel closing supply.
- Off-grid solar storage.
- Fire EPS emergency supply.
6. Installation & Maintenance
Installation
- Keep the battery room at 20 to 25 C (life halves per 10 C rise).
- Mount on a dedicated rack or cabinet; do not set on the floor.
- Series-connect + to -; torque connectors to 9 N-m.
- Bank voltage = unit voltage x unit count (20 x 12V = 240V).
- Connect the last + to the UPS + terminal and the – to the UPS – terminal.
- Measure open-circuit bank voltage after wiring (20 units about 265V full).
- Add a DC breaker between bank and UPS for isolation.
- New banks equalize-charge for 72 h before floating.
Maintenance
- Measure each unit’s OCV monthly (below 12.5V means under-charged or aged).
- Quarterly capacity check (discharge 30% to find the weak cell).
- Measure internal resistance yearly (30% over baseline means aged).
- Coat terminals with petroleum jelly against oxidation.
- Vent the battery room (overcharge releases hydrogen).
- Do not mix old and new cells.
7. FAQ
- Q:AGM or gel?
A:AGM (KTR-BAT-V100) has long float life (10 years) for standby UPS; gel has long cycle life (2000) for frequent solar cycling. Choose AGM for UPS, gel for solar. AGM has low internal resistance and high discharge current (UPS inrush); gel has higher resistance and poor high-current discharge. Do not use gel for UPS (voltage sags fast). - Q:Why is battery life 3 to 5 years instead of 10?
A:The rated 10 years is at 25 C float. Real rooms run at 30 to 35 C; life halves per 10 C rise, so actual life is about 5 years. Cool the room to 25 C with air conditioning to approach 10 years. Also, float voltage above 13.8V overcharges and dries out the cell. Measure each unit monthly and replace weak cells early. - Q:A cell is bulging; can I keep it?
A:No. Bulging means internal overcharge or short, and gas has expanded the case. Continued use risks leakage or fire. Replace immediately and check the charger float voltage (overcharge is the main cause). Dispose as hazardous waste (lead and sulfuric acid). - Q:One weak cell in the bank, what to do?
A:Replace the whole bank. Series strings are limited by the weakest cell (wooden-bucket effect). Swapping in one new cell means its low internal resistance and the old cells’ high resistance cause unequal charge/discharge; the new cell wears out quickly dragged by the old ones. Replace the whole bank; temporary single swap is OK but replace the whole bank within 3 months.
8. Trend & Selection
Lead-acid moves to sealed VRLA (maintenance-free); flooded (watering) is phased out. Lithium iron phosphate replaces lead-acid in data centers (half the size, twice the life, lighter), but at 2 to 3 times the upfront cost. BMS (cell voltage monitoring, balancing, alarms) becomes standard on lithium banks. Lead-acid moves to starved-electrolyte 12-year long-life designs. Online battery monitoring (internal resistance, temperature, voltage to EMCS) spreads in critical rooms.
9. Delivery & Service
KITOZER sizes KTR-BAT-V100 by UPS kW and backup time, providing cell-count tables (backup time = Ah x V x efficiency / kW) and cabinet layouts. Delivery includes batteries, connectors and certificate. Warranty 3 years (capacity guaranteed above 80%).
10. Additional Notes
A common pitfall is no air conditioning in the battery room. At 40 C in summer, battery life shrinks from 10 to 3 years. Run dedicated room air conditioning 24/7 at 25 C; alarm if AC fails (the room heats up fast).
Another pitfall is loose connectors. At less than 9 N-m torque, connectors overheat, contact resistance rises, and connectors glow red during discharge. Use a torque wrench; do not rely on feel. Re-torque yearly.
Selection summary: 12V100Ah; AGM; 10-year float; maintenance-free; M8 terminal. The lead-acid battery is the heart of UPS backup; the keys are room cooling, torque’d series connectors, monthly per-cell voltage, and whole-bank replacement of weak cells.
Additional tip: Old batteries contain lead and sulfuric acid (hazardous waste). Do not throw them away; send them to a licensed recycler. KITOZER can help arrange recycling. Ship upright; do not invert (valve-regulated cells technically allow inversion, but terminal leakage risk exists).