KITOZER KTR-BAT100D 12V100Ah Deep-cycle VRLA Battery for UPS

KITOZER KTR-BAT100D 12V100Ah Deep-cycle VRLA Battery for UPS

Brand: KITOZER Series: KTR-BAT100D Category: Power Distribution / UPS Battery

12V100AhDeep-cycleMaintenance-freeVRLA sealedKTR-BAT100D

1. Overview

KITOZER KTR-BAT100D is a 12V100Ah valve-regulated lead-acid (VRLA) battery of deep-cycle design, used as backup power for UPS, DC bus panels and emergency lighting. When mains fails, the battery bank inverts through the UPS to feed servers until generators start or a graceful shutdown. The battery bank is the heart of the UPS — however good the UPS unit, dead batteries cause outage. Datacenter banks usually series dozens of 12V batteries into a 384V/240V DC bus, housed in a dedicated battery room or cabinet.

KTR-BAT100D uses AGM (absorbent glass mat) technology: electrolyte is held in the glass-mat separator, so no leakage and flexible mounting. Deep-cycle design supports 80% depth of discharge, cycle life ≥1200 times (80% DOD), float design life 5~8 years at 25℃. Rated 12V / 100Ah (C10); float 2.25V/cell ×6 = 13.5V; equalize 2.35V/cell ×6 = 14.1V. M8 copper terminals, ABS flame-retardant case UL94-V0. Operating -15~50℃, recommended 20~25℃ battery room.

Used in datacenter UPS backup, telecom DC plants, PV storage and EPS. Typical config: a 200kVA UPS with 32 × 12V100Ah in series (384V) gives ~10~15 minutes at full load — enough to start the generator. Batteries sit on racks with insulation pads between layers, connected by copper bars/cables. The battery room is held at 25℃ — every 10℃ higher halves life — so it has dedicated air conditioning.

2. Key Features

Deep-cycle long life

  • 80% DOD design.
  • Cycle life ≥1200.
  • Float life 5~8 yr (25℃).
  • AGM absorbent tech.

12V100Ah

  • Rated 12V / 100Ah (C10).
  • M8 copper terminals.
  • Float 13.5V.
  • Self-discharge ≤3%/mo.

Sealed maintenance-free

  • VRLA sealed, no leak.
  • No watering.
  • ABS UL94-V0 case.
  • Flexible mounting.

Safe and reliable

  • Pressure relief valve.
  • Flame retardant.
  • Vibration-resistant.
  • CE/UL certified.

3. Specifications

Item KTR-BAT100D KTR-BAT65D
Rated voltage 12V 12V
Capacity (C10) 100Ah 65Ah
Float voltage 13.5V (25℃) 13.5V (25℃)
Equalize 14.1V (25℃) 14.1V (25℃)
Cycle life (80%DOD) ≥1200 ≥1200
Float life 5~8 yr 5~8 yr
Terminal M8 copper M6 copper
Op. temp -15~50℃ -15~50℃
Weight ~30kg ~20kg

4. Reference Prices

KTR-BAT100D 12V100Ah deep-cycle (AGM, 1200 cycles, 5~8 yr float): Reference USD 167~333 / pc (ref. CNY 1200~2400 at ~7.2)

KTR-BAT65D 12V65Ah (smaller UPS): Reference USD 111~208 / pc (ref. CNY 800~1500 at ~7.2)

Reference only; price varies by capacity, quantity and freight. Rack, inter-cell connectors, battery monitor and DC breaker billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Datacenter UPS battery bank.
  • Telecom DC plant.
  • PV / energy storage.
  • EPS emergency power.
  • Fire backup supply.

6. Installation & Maintenance

Installation

  • Fix rack level and secure.
  • Place batteries; insulate between layers.
  • Series to system voltage (e.g. 32 = 384V).
  • Torque connectors to 8~10 N·m.
  • Connect UPS DC breaker; check polarity.
  • Initial equalize charge 12~24h.

Maintenance

  • Record voltage and internal resistance monthly.
  • Do a capacity discharge test yearly.
  • Keep room at 25℃.
  • Check connectors for looseness/oxidation.
  • Replace cells with high resistance early.

7. FAQ

  • Q: How long do batteries last?
    A: 5~8 years float at 25℃. Temperature matters: a 35℃ room halves life to 3~4 years. Room AC is essential.
  • Q: Why a discharge test?
    A: On float, cells look fine but may have aged internally. A yearly capacity discharge reveals weak cells. Waiting for an outage to find out is too late.
  • Q: Can I mix old and new cells?
    A: No. High-resistance old cells are overcharged/over-discharged in the string and drag down new ones. Replace the whole bank, or at least same batch and capacity.
  • Q: Why dedicated room AC?
    A: Battery optimum is 20~25℃; heat ages them fast. Shared room AC fluctuates. Use independent AC with temp interlock.

8. Trend & Selection

Datacenter backup is shifting from VRLA to lithium: LFP packs offer higher energy density, 6000-cycle life and smaller footprint, at higher upfront cost. Trends are LFP packs with BMS replacing traditional VRLA, per-cell monitors for voltage/resistance, and AI life prediction. Choose 12V100Ah VRLA for traditional UPS; evaluate LFP for new projects; hold the room at 25℃; annual discharge test; replace weak cells; swap whole strings.

9. Delivery & Service

KITOZER supplies battery banks: based on UPS power, backup time and system voltage, we compute cell count and capacity. Bundled with UPS, racks, cell monitors and DC breakers. Delivery includes batteries, connectors, insulation pads and manual; bulk orders include install guidance and first charge/discharge commissioning. 3-year warranty.

10. Additional Notes

The most common battery problem is loose connectors. Under-torqued lugs raise contact resistance, heating or arcing during heavy discharge. Use a torque wrench to 8~10 N·m and recheck every one.

Another pitfall: a hot battery room. Since nobody sits there, people skimp on AC — summer room hits 35℃. Life decays exponentially with temperature: every 10℃ halves it. The saved electricity costs ten times more at replacement.

Selection summary: 12V100Ah VRLA deep-cycle; series to the UPS bus; 25℃ room; torque connectors; annual discharge test; replace weak cells in whole strings. The battery is the UPS heart — a healthy heart keeps the lights on at outage.