Table of Contents
ToggleKITOZER KTR-BAT12V120D9 VRLA Battery (12V120Ah)
Brand: KITOZER Series: KTR-BAT12V120D9 Category: Battery / VRLA Backup
12V120AhVRLAUPS backup8-year floatKTR-BAT
1. Overview
The KITOZER KTR-BAT12V120D9 is a 12V120Ah valve-regulated lead-acid (VRLA) battery using AGM absorbed glass-mat technology. Electrolyte is absorbed in the mat — no free fluid, no leakage, mountable in any orientation. Designed for UPS, DC operating panels, telecom base stations, fire systems and emergency lighting. On mains failure, the battery bank feeds the load through the inverter or DC bus to keep critical equipment running.
The KTR-BAT12V120D9 is rated 12 V, 120 Ah (20-hour rate, 25℃), dimensions about 406×174×233 mm (L×W×H), weight about 35 kg. M8 bolt terminals allow series connection into banks. The housing is ABS flame-retardant with a safety valve that vents overcharge pressure while remaining sealed in normal operation. Design float life is 5~6 years at 25℃ (12 V series).
In UPS systems, batteries are series-connected into a bank — e.g., 30 in series form a 384 V DC bus. The KTR-BAT12V120D9 supports series (up to 120 cells, 1440 V DC) and parallel (up to 4 strings). Bank capacity is sized by required backup time — longer backup means more Ah or more cells.
2. Key Features
AGM VRLA sealed
- Absorbed glass mat.
- No free electrolyte.
- Leak-free, maintenance-free.
- Safety relief valve.
12V120Ah capacity
- 12 V nominal.
- 120 Ah / 20 hr.
- M8 bolt terminals.
- ~35 kg each.
Long float life
- 5~6 yr float at 25℃.
- Low self-discharge ≤3%/mo.
- Deep-cycle recovery.
- FR ABS case.
Multi-scene backup
- UPS.
- DC panel.
- Telecom base station.
- Fire / emergency lighting.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-BAT12V120D9 |
| Nominal voltage | 12 V |
| Rated capacity | 120 Ah (20hr, 25℃) |
| Dimensions (L×W×H) | ~406×174×233 mm |
| Weight | ~35 kg |
| Terminal | M8 bolt |
| Float voltage | 13.5~13.8 V (25℃) |
| Equalize charge | 14.4~14.7 V (25℃) |
| Self-discharge | ≤3%/mo (25℃) |
| Operating temp | -15~50℃ (discharge) |
| Design life | float 5~6 yr (25℃) |
| Housing | ABS FR |
4. Reference Prices
KTR-BAT12V120D9 12V120Ah VRLA: Reference USD 104~167 / pc (ref. CNY 750~1200 at ~7.2)
KTR-BAT12V100 12V100Ah (smaller): Reference USD 76~118 / pc (ref. CNY 550~850 at ~7.2)
KTR-BAT2V200 2V200Ah (2V series, opt.): Reference USD 49~83 / pc (ref. CNY 350~600 at ~7.2)
Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- UPS backup battery banks.
- Substation DC operating panels.
- Telecom base station backup.
- Fire alarm system backup.
- Emergency lighting / elevator backup.
6. Installation & Maintenance
Installation
- Rack spacing ≥10 mm for cooling.
- Series connection with torqued bolts.
- Coat terminals with petroleum jelly.
- Consistent polarity direction.
- Measure bank voltage.
- Connect to UPS DC bus.
Maintenance
- Measure cell voltage monthly.
- Check terminals quarterly.
- Capacity discharge test yearly.
- Keep ambient 20~25℃.
- Recharge depleted cells promptly.
- Replace whole bank at end of life.
7. FAQ
- Q:Short backup time — why?
A:First check for a lagging cell (low voltage) — it drags down the whole bank. Then verify UPS charge voltage; chronic undercharge fades capacity. Finally, recalculate load power vs bank Ah. - Q:Battery bulging?
A:Usually overcharge or high ambient temperature. Overcharge builds gas faster than the relief valve vents; temperatures above 30℃ accelerate thermal runaway. Check charger voltage and improve room cooling. - Q:Do new batteries need initial charge?
A:Factory charge is ~80~90%; float-charge 24 h after installation before loading. If stored over 3 months, recharge to 13.5 V+ before install. - Q:Can I mix old and new batteries?
A:Not recommended. Different internal resistance and capacity cause over-discharge of old cells and overcharge of new ones in series, accelerating bank failure. Replace as a whole bank, same brand and batch.
8. Trend & Selection
VRLA batteries are trending toward longer life (AGM gel), smart monitoring (internal resistance), and Li-ion replacement. In data centers, LFP adoption in UPS is growing, but VRLA remains mainstream due to low cost and maturity. Select by voltage class, capacity, backup time, space and life requirement.
9. Delivery & Service
KITOZER sizes the KTR-BAT bank by UPS backup time and DC bus voltage, providing rack layout and connection drawings. Delivery includes battery bodies, inter-cell links, certificate, factory capacity test report and manual. Warranty covers capacity testing and lagging-cell troubleshooting.
10. Additional Notes
A common pitfall is a hot battery room. Lead-acid life halves for every 10℃ rise; at 30℃ life is roughly half that at 25℃. The room needs AC or ventilation to hold 20~25℃.
Another pitfall is loose terminal connections. High discharge current heats loose bolts and can arc or erode them. Torque to spec (M8 about 9~11 N·m) and re-torque quarterly.
Additionally, never top up AGM VRLA batteries with water — they are sealed and valve-regulated; opening the vent disrupts the recombination cycle. Keep the battery room well ventilated because small amounts of hydrogen vent during charging; avoid sparks and unvented light fixtures. When connecting parallel strings, use identical cable lengths and cross-sections per string to balance current sharing.
Selection summary: 12V120Ah AGM; 5~6 yr float; M8 terminals; series bank; 25℃ optimum. The battery is the heart of the UPS — right capacity, controlled temperature, periodic capacity tests keep the load running until the generator starts on mains failure.