KITOZER KTR-BAT24E Battery / 12V 24Ah Deep Cycle

KITOZER KTR-BAT24E Battery / 12V 24Ah Deep Cycle

Brand: KITOZER Series: KTR-BAT24E Category: Power Distribution / UPS Battery

12V24AhDeep cycleVRLA sealedLong lifeUPS matched

[Product image: ktr-bat24e-12v24ah-deep-cycle-battery.jpg]

1. Overview

Batteries are the storage heart of UPS and backup systems. When mains fails, the battery bank takes over the DC bus within seconds, keeping the UPS alive long enough for generator start or orderly shutdown. Undersized, aged or poorly maintained batteries let the whole UPS down during a real outage. VRLA batteries, maintenance-free, leak-proof and mountable in any orientation, dominate data-center UPS.

The KITOZER KTR-BAT24E is a 12V 24Ah deep-cycle VRLA sealed lead-acid battery. Nominal 12 V, rated 24 Ah (20-hour rate), using AGM absorptive separators and an oxygen-recombination cycle with no water topping-up. The deep-cycle design tolerates deeper discharge followed by recharge, suiting short, frequent discharge and backup duty. The flame-retardant ABS case has a top vent and tin-plated copper terminals to reduce connection drop. Float life is about 5 to 8 years at 25 C, and units can be series-strung (e.g. twenty x 12 V for a 240 V DC bus).

Selection confirms per-unit voltage (12 V), capacity (24 Ah), series/parallel count (by the UPS DC bus voltage and backup time), rack footprint and load, and ambient temperature (life roughly halves for every 10 C rise). Room UPS often strings units in series; small units need one string, while longer backup needs larger capacity or parallel strings. Mount the bank in a dedicated cabinet or rack with even spacing for inspection and replacement.

2. Key Features

12V24Ah deep cycle

  • Nominal 12 V, rated 24 Ah (20 hr).
  • AGM separators, oxygen recombination.
  • Deep-cycle design tolerates deeper discharge.
  • Maintenance-free, no watering.

Structure and safety

  • Flame-retardant ABS case.
  • Top explosion-proof vent.
  • Tin-plated copper terminals, low drop.
  • Series-stringable.

Long life

  • Float life 5 to 8 years at 25 C.
  • Low self-discharge.
  • Suits UPS and DC panel storage.
  • Rack / cabinet mounting.

3. Specifications

Item Specification
Nominal voltage 12 V
Rated capacity 24 Ah (20 hr rate)
Battery type VRLA sealed lead-acid (AGM)
Design life 5 to 8 years (25 C float)
Charge voltage Float about 13.6 to 13.8 V
Terminals Tin-plated copper
Case Flame-retardant ABS
Operating temp -15 to +50 C
Mounting Rack/cabinet, series strings
Application UPS / DC panel backup storage

4. Reference Prices

KTR-BAT24E 12V24Ah deep-cycle battery (each): USD 39~58 (ref. CNY 280~420)

Copper connector bar (matched): USD 2~4 (ref. CNY 15~30)

Battery cabinet / rack (per string): USD 83~208 (ref. CNY 600~1500)

Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Backup battery strings for small UPS.
  • DC panel and operating power storage.
  • Emergency lighting and fire backup.
  • Telecom base-station backup.
  • Battery packs for rack-mounted micro-module UPS.

6. Installation & Maintenance

Installation

  • Set series count by the UPS DC bus voltage.
  • Use same model and batch within a string.
  • Torque connector bars to spec.
  • Ground the rack, space cells for ventilation.
  • Set float voltage per the maker.
  • Perform an initial charge/discharge.
  • Label each cell with number and commissioning date.

Maintenance

  • Measure float voltage and appearance monthly.
  • Run a capacity/discharge check quarterly.
  • Check connector torque and oxidation yearly.
  • Keep the battery room at 20 to 25 C.
  • Replace bulging or leaking cells at once.
  • Replace in batch at end of life; do not mix old and new.

7. FAQ

  • Q: Can old and new batteries be mixed?
    A: A: Not recommended. Different internal resistances unbalance discharge, drag the string down and speed damage. Replace in one batch.
  • Q: Why control the battery-room temperature?
    A: A: Float life roughly halves every 10 C rise; 20 to 25 C is the design baseline. Heat shortens life and raises swelling risk.
  • Q: How long does 24Ah last?
    A: A: It depends on UPS load and string count. A small UPS with a 24 Ah string typically lasts minutes to over ten minutes; longer backup needs more capacity.
  • Q: Can a swollen battery still be used?
    A: A: No. Swelling means internal failure; continued use risks leakage and overheating. Isolate and replace, and check charge voltage.

8. Trend & Selection

Data-center storage is evolving from VRLA toward lithium, string UPS and BMS, but VRLA remains widely used in small-to-mid UPS for maturity, low cost and reliability. Monitoring moves from manual inspection to online internal-resistance sensing and remote warning, making replacement cycles more scientific. Size capacity by DC bus and backup time, string in one batch, control temperature and ventilation, and integrate with environmental monitoring.

9. Delivery & Service

KITOZER ships KTR-BAT24E with the battery, connector bars, manual and certificate. Cabinets/racks are supplied per string count, with initial charge and internal-resistance testing guidance.

10. Notes

A common mistake is looking only at rated capacity and ignoring string count. UPS backup time depends on whole-string voltage and capacity; one 24 Ah cell is not the string backup time.