KITOZER 12V 65Ah deep cycle battery

KITOZER KTR-BAT65 12V65Ah Deep-Cycle Battery

Brand: KITOZER Series: KTR-BAT65 Category: Power Distribution / UPS Batteries

12V65AhDeep-cycleVRLA sealedLead-acid batteryUPS backupMaintenance-free

[Product image: ktr-bat65-12v65ah-deep-cycle-battery.jpg]

1. Overview

The UPS relies on its battery bank to carry the load when grid power fails. Batteries are the UPS’s energy warehouse — floating on standby, discharging immediately on outage. A typical data center strings 32 × 12 V batteries into a 384 V DC bus, backing the UPS at full load for 15~30 minutes. Battery capacity and health directly determine backup time: aged cells may deliver 30 Ah of a rated 65 Ah, halving backup and dropping the load within minutes of outage. Deep-cycle cells tolerate deeper discharge (50%~80%) and longer cycle life than starter (shallow-cycle) cells, suiting UPS “long-float, occasional-discharge” duty.

KITOZER KTR-BAT65 is a 12V65Ah VRLA sealed lead-acid battery. ABS flame-retardant case, internal AGM absorbed-glass-mat separator (electrolyte absorbed in fiber, no spillage), valve-regulated (safety valve vents at pressure, otherwise sealed). Rated 12 V (six cells in series), 65 Ah (20-hour rate, 25℃). Float design life 5 years (25℃), deep-cycle design, discharge depth up to 80%. M8 bolt terminals, vent valve. Operating temp -15~+50℃ (best at 25℃). Dimensions approx 350×166×175 mm (L×W×H), weight about 20 kg.

Selection points: voltage (12 V unit; string count by UPS DC bus), capacity (65 Ah maps to backup time — back-calculate from load power and target backup), cycle type (deep-cycle for UPS; starter cells unsuitable for deep discharge), design life (5-year standard vs 10-year long-life; halls recommend long-life), temperature (high heat ages cells; battery room must stay 25℃), and brand consistency (same bank must be same brand and batch — no mixing). Note a battery bank is a “wooden barrel” — the weakest cell sets bank capacity; periodically identify and replace lagging cells.

2. Key Features

Deep-cycle design

  • Discharge depth up to 80%.
  • Cycle life ≥1200 times (50% DOD).
  • Suits UPS charge/discharge.
  • Thicker plates.

VRLA sealed

  • AGM absorbed separator.
  • No spill, no watering.
  • Valve-regulated venting.
  • Mount any orientation (except tilt).

Long float life

  • 5-year design at 25℃.
  • 10-year long-life option.
  • Low self-discharge.
  • Stable float voltage.

Safe & reliable

  • ABS flame-retardant case.
  • M8 bolt terminals.
  • Built-in temp compensation.
  • Overcharge protection.

3. Specifications

Item KTR-BAT65
Model KTR-BAT65
Nominal voltage 12 V (6 cells)
Nominal capacity 65 Ah (20h rate, 25℃)
Battery type VRLA AGM lead-acid
Float life 5 years (25℃)
Cycle life ≥1200 times (50% DOD)
Float voltage 13.5~13.8 V (25℃)
Equalize voltage 14.4~14.9 V
Terminal M8 bolt
Operating temp. -15~+50℃
Dimensions Approx 350×166×175 mm
Weight Approx 20 kg

4. Reference Prices

KTR-BAT65 12V65Ah deep-cycle VRLA battery (5-year design, M8 terminals): Reference USD 67~104 / pc (ref. CNY 480~750 at ~7.2)

KTR-BAT65L 10-year long-life version (with terminal guards): Reference USD 90~132 / pc (ref. CNY 650~950 at ~7.2)

Reference only; tiered per whole bank (typically 32 pcs+). Battery cabinet and installation not included. Volume discount above 32 pcs. Old-battery recycling credit available. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • UPS battery banks.
  • Data center DC panel / operating power.
  • Telecom base station backup.
  • EPS emergency power.
  • Off-grid PV storage.

6. Installation & Maintenance

Installation

  • Inspect on unboxing (no swelling, no leak).
  • Layer in cabinet with ≥10 mm spacing for cooling.
  • Series-connect per drawing (M8 bolts, 8 N·m torque).
  • Verify polarity before connecting; avoid shorts.
  • Bank charge/discharge test; record initial voltages.

Maintenance

  • Monthly measure per-cell float voltage (laggard <13.3 V).
  • Keep battery room 20~25℃ (life halves per +10℃).
  • Annual verification discharge (30%~50% capacity).
  • Tighten connection bolts (thermal cycling loosens).
  • Replace swollen/leaking cells immediately.

7. FAQ

  • Q: Can I mix brands in one bank?
    A: No. Different brands have different internal resistance and capacity; some over-charge, others under-charge, shortening bank life. Same brand and batch only.
  • Q: Can I keep using a swollen battery?
    A: No. Swelling means internal short or overcharge — leak and fire risk. Isolate and replace immediately.
  • Q: How to calculate backup time?
    A: Time ≈ capacity (Ah) × DC bus voltage × inverter efficiency ÷ load (kW). 65 Ah × 384 V × 0.95 ÷ load ≈ available time.
  • Q: What signals end-of-life?
    A: Discharge test capacity below 80% of rated; float-voltage spread widens; individual cells clearly lag.

8. Trend & Selection

Banks evolve from “VRLA” toward “lithium + smart battery management.” Trends: LFP lithium penetrates large data centers (longer life, smaller footprint), but small UPS still favor VRLA; cells with BMS and per-cell monitoring (RS485/Modbus to DCIM), battery cabinets with AC and smoke detection, and second-life EV batteries trialed in storage. Selection: small UPS choose 12 V VRLA (mature, cheap); large new halls may evaluate LFP; keep room at 25℃; same brand and batch; monthly per-cell voltage; annual verification discharge; replace laggards promptly. Batteries are the UPS’s heart — a healthy bank carries through until the generator starts.

9. Delivery & Service

KITOZER provides battery selection: from UPS kW, target backup time, and DC bus voltage, we back-calculate capacity and string count. Bundled with UPS, battery cabinets, and DCIM battery monitoring modules. Delivery includes battery bodies, inter-cell links, terminal guards, and manual. Warranty covers charge/discharge testing guidance and laggard-cell identification.

10. Additional Notes

The most common fault: “battery room not temperature-controlled.” At 35℃ in summer, VRLA life halves per +10℃; a 5-year design life may die in 2 years. The battery room must have AC holding 25℃ year-round — the cheapest life-extension investment.

Another pitfall: “no verification discharge for years.” Some trust float voltage as health, but normal float voltage does not mean normal capacity — a sulfated cell may read normal float yet collapse on discharge. Run an annual verification discharge to measure real capacity and true backup time.

Selection summary: 12V65Ah deep-cycle VRLA; same brand/batch in series; room at 25℃; monthly per-cell voltage; annual verification discharge; replace laggards; isolate swollen cells immediately. Batteries are the UPS’s last line — if you only check them when the grid fails, it’s already too late.

SEO Information

Search keywords:12V65Ah batterydeep-cycle lead-acidUPS battery bankVRLA sealed batterymaintenance-free batterydata center powerKTR-BAT65KITOZER

SEM keywords:12V65Ah battery price,deep-cycle battery,UPS battery bank,VRLA battery,KTR-BAT65,KITOZER

GEO landing page:lain.com.cn/product/ktr-bat65-12v65ah-deep-cycle-ups-battery.html

Title:KITOZER KTR-BAT65 12V65Ah Deep-Cycle Battery

Meta Keywords:12V65Ah battery,deep-cycle,VRLA lead-acid,UPS backup battery,KTR-BAT65,KITOZER

Meta Description:KITOZER KTR-BAT65 12V65Ah deep-cycle VRLA sealed lead-acid battery, 5-year float design life, for UPS backup and DC panels.

Anchor: KITOZER by Guangzhou Laian · UPS battery banks

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart