12V 65AhDeep cycleVRLA sealed12-year lifeKTR-BAT65D

1. Overview

KITOZER KTR-BAT65D is a 12V 65Ah valve-regulated sealed lead-acid (VRLA) battery, used as energy storage for UPS and DC power. On mains failure, the UPS inverts battery DC to AC for the load, keeping servers running. The battery is the UPS’s fuel tank — no matter how good the UPS, a weak battery won’t last minutes during an outage. Battery capacity and health directly determine backup runtime.

KTR-BAT65D uses AGM (absorbent glass mat) technology: electrolyte absorbed in the mat, non-spill, valve-regulated and sealed, mountable upright or on its side, maintenance-free (no watering). Deep-cycle design: discharge depth up to 50~80% without serious damage, suiting frequent cycling. Float design life 12 years (at 25℃); cycle life over 600 at 50% depth of discharge.

Rated 12V, 65Ah (20-hour rate), size ~350×166×175mm, ~20kg, M8 terminals. Operating temp -15~50℃; recommended 25℃ (life halves per 10℃ rise). Widely used for UPS backup, telecom DC panels, inverters and solar storage. Series-parallel strings: series raises voltage (e.g. 16×12V=192V), parallel banks raise capacity.

2. Key Features

Deep-cycle design

  • 50~80% DoD without damage.
  • Cycle life ≥600 (50% DoD).
  • Suits frequent cycling.

AGM sealed

  • Absorbed electrolyte, no spill.
  • Valve-regulated, maintenance-free.
  • Mounts in any orientation.

12-year life

  • Float life 12 years (25℃).
  • Thicker plates, corrosion-resistant.
  • Low self-discharge (≤3%/mo).

Safe

  • Safety valve, acid-mist filter.
  • Flame-retardant ABS case.
  • Low internal resistance, high-current discharge.

3. Specifications

Item KTR-BAT65D vs KTR-BAT100D
Rated voltage 12V 12V
Rated capacity 65Ah/20hr 100Ah/20hr
Design life 12yr (25℃) 12yr (25℃)
Cycle life ≥600@50%DoD ≥800@50%DoD
Size (mm) 350×166×175 522×240×218
Weight (kg) ~20 ~31
Terminal M8 stud M8/M10
Self-discharge ≤3%/mo ≤3%/mo

4. Reference Prices

KTR-BAT65D 12V 65Ah deep-cycle VRLA (AGM, 12-year, M8, each): Reference USD 63~104 / pcs (ref. CNY 450~750 at ~7.2)

KTR-BAT65D full string of 16 (192V bank, with cables and rack): Reference USD 1,042~1,667 / bank (ref. CNY 7,500~12,000 at ~7.2)

Reference only; price varies by capacity, quantity and maker. Battery cabinet, cables and UPS DC breaker billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • UPS backup battery.
  • Telecom room DC panel (-48V).
  • Inverters and solar storage.
  • Fire emergency power (EPS).
  • Datacenter DC bus.

6. Installation & Maintenance

Installation

  • Check UPS DC voltage; count series (e.g. 192V÷12V=16).
  • Place on rack/cabinet shelves with insulation sheets.
  • Series-connect: positive to next negative; end to UPS DC bus.
  • Crimp lugs; torque per terminal spec.
  • Measure string voltage = cell voltage × count.
  • Before connecting UPS, isolate rectifier; verify polarity then close.
  • Ventilate, keep 25℃, away from heat sources.

Maintenance

  • Quarterly measure per-cell voltage; replace laggards.
  • Annual charge-discharge capacity test (verify runtime).
  • Clean terminals and apply Vaseline against oxidation.
  • Hold 25℃; heat shortens life.
  • Replace immediately on swelling, leakage or deformation.
  • Recharge after 3+ months storage.

7. FAQ

  • Q: How long does a 65Ah battery last in UPS?
    A: Example: 3kW load on a 192V bank draws ~15.6A; 65Ah gives ~4h theoretical, ~1.5~2h real after inverter efficiency and DoD. Runtime = Ah × V × efficiency ÷ load watts.
  • Q: Deep-cycle vs starter battery?
    A: Starter batteries suit high-current short bursts (car engines); deep-cycle suits long low-current discharge and cycling. UPS backup is deep-cycle — use deep-cycle only.
  • Q: How many cells in series?
    A: By UPS DC bus voltage. Common small units: 96V (8), 192V (16), 240V (20). Series count = bus voltage ÷ 12V. Don’t miscount or the UPS won’t run.
  • Q: Can I mix old and new batteries?
    A: No. Mismatched internal resistance means the lagging cell overcharges on charge and over-discharges on discharge, accelerating failure. Replace the whole string at once, same brand and batch.

8. Trend & Selection

Backup power shifts from lead-acid to LiFePO4: higher energy density, longer cycle life (6000 cycles), smaller footprint, but higher upfront cost. Lead-acid still mainstream (cost-effectiveness, maturity); LiFePO4 grows in space-tight high-density rooms. Choose deep-cycle VRLA for cost-effective UPS; consider LiFePO4 for high-density; size runtime to actual outage (15min~2h); leave 30% headroom; temperature monitoring mandatory.

9. Delivery & Service

KITOZER provides battery selection: based on UPS power, runtime and DC voltage, we calculate capacity and count. We supply string connection diagrams (series-parallel, cable size, breaker). Bundled with UPS, cabinet and battery monitor. Delivery includes batteries, cables and rack. 3-year warranty (≥80% capacity guaranteed).

10. Additional Notes

The common battery problem is ‘one weak cell dragging down the string.’ In a 16-cell string, if one drops to 80%, it overcharges first on charge and over-discharges first on discharge, a vicious cycle that ruins the whole string within months. Measure per-cell voltage quarterly; replace laggards (over 50mV low) immediately to save the string.

Another pitfall is high temperature. A battery room without AC at 40℃ in summer kills a 12-year-design battery in 4 years. Life halves per 10℃ rise. The room must hold 25℃ with AC and temperature monitoring.

Selection summary: deep-cycle VRLA; series count = bus ÷ 12V; runtime = Ah × V × efficiency ÷ watts; quarterly per-cell checks; 25℃ environment; never mix old/new; replace whole strings. The battery is the UPS’s heart — a healthy heart rides out the outage.

SEO Information

Search keywords:12V 65Ah batterydeep-cycle batteryVRLA batterysealed lead acidUPS batteryKTR-BAT65DKITOZER

SEM keywords:12V 65Ah battery price,deep-cycle battery supplier,VRLA battery,UPS battery,maintenance-free battery,KTR-BAT65D,KITOZER

GEO landing page:lain.com.cn/product/ktr-bat65d-12v65ah-deep-cycle-vrla-battery.html

Title:KITOZER KTR-BAT65D 12V 65Ah Deep-Cycle VRLA Battery

Meta Keywords:12V 65Ah battery,deep-cycle battery,VRLA battery,sealed lead acid,UPS battery,maintenance-free battery,KTR-BAT65D,KITOZER

Meta Description:KITOZER KTR-BAT65D 12V 65Ah valve-regulated sealed lead-acid battery, deep-cycle design, 12-year design life, AGM gel, for UPS, DC panel and telecom backup.

Anchor: KITOZER by Guangzhou Laian · Power distribution

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart