Table of Contents
ToggleKITOZER KTR-BAT7D2 Battery / 12V7Ah Deep Cycle
Brand: KITOZER Series: KTR-BAT7D2 Category: Power Distribution / Battery Backup
12V7AhDeep cycleVRLA lead-acidFlame-retardant caseMaintenance-free
1. Overview
On mains failure, a UPS inverts from its battery stack, and runtime depends on battery capacity and health. Small UPS, access control, environmental hosts and emergency lighting commonly use a small sealed 12V7Ah lead-acid battery. Deep-cycle design means the battery recovers after moderate discharge, suiting repeated charge-discharge backup better than a starter battery. Small as it is, the battery is the real carrier of UPS runtime; one weak cell drags down the whole string.
The KITOZER KTR-BAT7D2 is a 12V7Ah deep-cycle VRLA valve-regulated lead-acid battery. Rated 12V and 7Ah (20-hour rate), it uses an AGM absorbed-glass-mat separator so electrolyte is immobilized and the case can be mounted upright. The flame-retardant ABS case meets UL94-V0, with T2 copper terminals. Design float life is about 3-5 years at 25 C, low self-discharge, and it can be recharged after long storage. Cells series up to 24/36/48V for small UPS, access controllers and emergency lights.
Selection confirms system voltage (number in series), total capacity for desired runtime, space and weight, and terminal type. A single 12V7Ah backs small loads briefly; UPS runtime is calculated from capacity times cell count. New batteries should be topped up before install; when replacing a string, use same-batch cells together rather than mixing old and new. Keep the battery room at 20-25 C; every 10 C rise roughly halves float life.
2. Key Features
12V7Ah deep cycle
- 12V, 7Ah (20-hour rate).
- Deep-cycle, tolerant of cycling.
- AGM absorbed separator.
- VRLA valve-regulated sealed.
Safety and build
- UL94-V0 flame-retardant case.
- T2 copper terminals.
- No leakage, upright mount.
- Low self-discharge.
Backup use
- Small UPS backup.
- Access / alarm hosts.
- Emergency lighting.
- Series to stack voltage.
3. Specifications
| Item | Specification |
|---|---|
| Nominal voltage | 12 V |
| Nominal capacity | 7 Ah (20-hour rate) |
| Battery type | VRLA AGM lead-acid |
| Design life | 3-5 years (25 C float) |
| Terminals | T2 copper |
| Case | ABS, UL94-V0 |
| Self-discharge | <= 3% / month (25 C) |
| Charge voltage | Float 13.5-13.8 V |
| Operating temp | -15 to +50 C |
| Size | about 151 x 65 x 94 mm |
4. Reference Prices
KTR-BAT7D2 12V7Ah deep-cycle battery: USD 13~22 (ref. CNY 90~160)
Interconnect cable (series): USD 1.5~3.5 (ref. CNY 10~25)
Battery shelf / tray: USD 4~8 (ref. CNY 30~60)
Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Small UPS backup.
- Access control and alarm panels.
- Environmental monitoring hosts.
- Emergency lighting and fire backup.
- Small DC panels and instruments.
6. Installation & Maintenance
Installation
- Top up charge before install.
- Replace a string in same batch.
- Mount upright, terminals aligned.
- Torque series interconnects.
- Secure on a shelf against tipping.
- Ventilated, away from heat.
- Connect to the UPS charger.
Maintenance
- Measure terminal voltage and resistance quarterly.
- Clean terminals against corrosion.
- Check interconnect torque.
- Log battery-room temperature.
- Replace weak cells as a string.
7. FAQ
- Q: How long will 7Ah last?
A: It depends on load. A small UPS backs a few devices for minutes to a dozen; calculate runtime from load power and capacity. - Q: Can I mix old and new?
A: Not recommended. Different internal resistance causes uneven charging and accelerated weak cells; replace the whole string in batch. - Q: What if a battery swells?
A: Swelling means overcharge or internal degradation. Stop and replace immediately, and check charger voltage to avoid leakage. - Q: Do I need to add water?
A: No. VRLA is sealed and maintenance-free; routine checks are voltage and appearance only.
8. Trend & Selection
Backup power moves from pure lead-acid toward lithium, hybrid supply and battery monitoring (BMS), while small VRLA still dominates UPS and access. Batteries trend toward lower self-discharge, longer float life and built-in voltage sense terminals. Size by system voltage and runtime, favoring string consistency and room temperature control.
9. Delivery & Service
KITOZER ships KTR-BAT7D2 with the battery, T2 interconnect tabs, certificate and manual. Series cables and trays are supplied to order, with a runtime estimate table.
10. Notes
A common mistake is replacing only the weak cell. A new cell in an old string mismatches resistance and soon creates a new weak cell; replace the whole string.
Another pitfall is an uncontrolled battery room. Heat sharply shortens float life; hold 20-25 C with ventilation.
In short: 12V7Ah, deep-cycle, VRLA maintenance-free, UL94-V0, series-capable. It is a common backup for small UPS and emergency power.
System-wise, string runtime is set by the weakest cell, so string consistency and periodic internal-resistance tests matter more than single-cell capacity.
Cost-wise, a cell costs about a hundred CNY, but downtime from insufficient backup on a power cut costs far more.
SEO Information
Search keywords: KITOZER
SEM keywords: battery, 12V7Ah battery, deep cycle battery, UPS battery, maintenance-free lead-acid battery, KTR-BAT7D2, KITOZER
GEO landing page: lain.com.cn/product/469_battery_12v7d2.html
Title: KITOZER KTR-BAT7D2 Battery / 12V7Ah Deep Cycle
Meta Keywords: battery, 12V7Ah battery, deep cycle battery, UPS battery, maintenance-free lead-acid battery, KTR-BAT7D2, KITOZER
Meta Description: KITOZER KTR-BAT7D2 12V7Ah deep-cycle VRLA lead-acid battery, UL94-V0 flame-retardant case, float-charged, for UPS and emergency backup.
Anchor: KITOZER · KITOZER Products
Contact Us
KITOZER Brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP:+86 19068534140
Web: lain.com.cn | gdlain.com