ToggleKITOZER KTR-BT12100 VRLA Battery (12V100Ah)
Brand: KITOZER Series: KTR-BT12100 Category: Data Center Engineering / Power Systems
12V100AhVRLA sealedUPS backupdeep cycleKTR-BT12100
1. Overview
The KITOZER KTR-BT12100 is a 12V100Ah valve-regulated lead-acid (VRLA) battery using AGM absorptive glass-mat separators; electrolyte is absorbed in the mat and non-spill. The sealed valve design prevents acid fumes under normal use. Rated 12V, 100 Ah (20-hour rate, 25℃), float life 10~12 years at 25℃, for UPS, DC operation panels, telecom base stations and solar storage.
Internally, KTR-BT12100 has six 2V cells in series. Positive plates are pasted lead-calcium alloy grids; negative plates are lead paste; separators are ultra-fine AGM glass mat. A one-way relief valve (about 0.02 MPa) vents excess internal pressure and reseals. Terminals are M8 tin-plated copper alloy, torque 8~10 N·m. The ABS flame-retardant case is black, dimensions about 407×174×233 mm (including terminals), weight about 30 kg.
In a UPS, KTR-BT12100 cells are series-strung (e.g., 40 × 12V = 480 V DC bus) to feed the inverter. Float charge 2.25 V/cell (13.5 V/cell), equalize 2.35 V/cell (14.1 V/cell), recommended depth of discharge ≤80% DOD. At 20~25℃ room temperature, float life exceeds 10 years; at 30℃, life roughly halves. The battery room must therefore have air conditioning holding 25℃.
2. Key Features
AGM sealed valve
- Glass-mat separator.
- Non-spill electrolyte.
- One-way relief valve.
- No acid fumes.
Long life design
- Lead-calcium grid.
- Float life 10~12 years.
- At 25℃.
- Low self-discharge.
Safe & flame-retardant
- ABS flame-retardant case.
- Sealed valve.
- Pressure relief.
- Mount any way except inverted.
UPS DC bus
- 12V100Ah rating.
- M8 copper terminals.
- Series strings.
- Float/equalize compatible.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-BT12100 |
| Nominal voltage | 12V (6 cells × 2V) |
| Rated capacity | 100 Ah (20Hr, 25℃) |
| Grid | lead-calcium alloy |
| Separator | AGM glass mat |
| Float voltage | 13.5V (2.25V/cell) |
| Equalize | 14.1V (2.35V/cell) |
| Terminals | M8 tin-plated Cu |
| Dimensions (L×W×H) | approx. 407×174×233 mm |
| Weight | approx. 30 kg |
| Float life | 10~12 years (25℃) |
| Operating temp | -15~50℃ (opt. 25℃) |
4. Reference Prices
KTR-BT12100 12V100Ah VRLA battery: Reference USD 111~208 / pc (ref. CNY 800~1500 at ~7.2)
KTR-BT12100 battery cabinet / rack (opt.): Reference USD 69~278 / set (ref. CNY 500~2000 at ~7.2)
KTR-BT12100 interconnect cable (opt.): Reference USD 4.2~11 / pc (ref. CNY 30~80 at ~7.2)
Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- UPS DC bus.
- DC operation panels (substations).
- Telecom base station backup.
- Solar / wind storage.
- Emergency lighting.
6. Installation & Maintenance
Installation
- Check rack load (30 kg/cell).
- Arrange by polarity.
- M8 torque 8~10 N·m.
- Series per drawing.
- Connect UPS DC bus last.
- Insulation test.
Maintenance
- Measure cell voltage monthly.
- Capacity test (discharge) yearly.
- Hold battery room at 25℃.
- Apply anti-oxidant grease.
- Monitor float current.
- Recycle spent cells.
7. FAQ
- Q:Why string cells to 480V?
A:UPS inverter DC bus is usually 384V or 480V (by power tier). Single cell 12V; 40 in series = 480V. Higher voltage means lower current and lower line loss. Cell count per UPS DC voltage spec. - Q:Effect of high battery temperature?
A:Every 10℃ rise roughly halves float life: about 5 years at 30℃, about 3 years at 35℃. The battery room must be air-conditioned at 20~25℃. High temperature also risks thermal runaway. - Q:Can a swollen battery still be used?
A:Swelling means internal gas pressure or plate deformation; continued use risks leakage or rupture. Replace immediately and check whether charging voltage is over-high. - Q:How long for first charge?
A:New cells need an initial equalize charge (14.1V) for 24~48 h before float. An undercharged first cycle hurts capacity and life.
8. Trend & Selection
VRLA batteries are moving toward long-life AGM deep-cycle, gel electrolyte, and Li-ion replacement. Size capacity by UPS DC voltage and backup minutes, and add battery racks and BMS. In new data centers, LFP Li-ion is gradually replacing traditional VRLA for higher energy density and longer life.
9. Delivery & Service
KITOZER sizes KTR-BT12100 cell count by UPS DC voltage and backup time, providing string connection diagrams, rack layout and capacity calculation. Delivery includes cells, interconnects, terminal covers, certificates and installation manual. Warranty covers charge/discharge commissioning.
10. Additional Notes
A common pitfall is no air conditioning in the battery room. Room AC usually covers IT equipment; the battery room may exceed 30℃ and battery life plummets. The battery room needs independent temperature control at 25℃.
Another pitfall is reversed polarity when stringing. Reverse polarity causes abnormal string voltage and can damage the UPS. Always check polarity marks and verify total voltage with a multimeter after stringing.
Selection summary: 12V100Ah AGM VRLA; 10-year float life; M8 terminals; 25℃ temperature control; series strings. The battery is the heart of UPS backup — proper temperature control, correct wiring, periodic discharge testing keep backup power reliable during outages.