KITOZER
KITOZER

KITOZER KTR-FL13 Modular Cabinet Plinth with Cable Trough

KITOZER KTR-FL13 Modular Cabinet Plinth with Cable Trough

Brand: KITOZER Series: KTR-FL13 Category: Data Center Engineering / Cabinet Infrastructure

cabinet plinthrack basecable troughmodular cold aisleload baseKTR-FL13

[Product image: KITOZER KTR-FL13 cabinet plinth body with side cable trough opening]

1. Overview

KITOZER KTR-FL13 is a modular steel plinth installed under 19-inch server racks, supporting the cabinet weight and providing bottom cable entry. In modular cold-aisle data halls, racks are arranged in enclosed rows; placing racks directly on the floor is neither clean nor cable-friendly — power and network cords either come up through floor cutouts or drag across the floor. The KTR-FL13 raises the rack 100/200/300 mm, with side cable-trough openings on the plinth so power and data cables enter the cabinet from the side, while the plinth distributes the rack load evenly onto the raised floor or concrete slab.

KTR-FL13 is folded and welded from Q235 carbon steel with electrostatic powder coating (RAL9005 black or light gray), rated ≥1000 kg per plinth. Long side slots are fitted with brush strips that let cables through while blocking hot/cool air leakage. All four sides can be opened; choose by the routing direction. When racks are placed side by side, adjacent trough slots align to form a continuous under-rack cable corridor — cables run through the plinth interior, no extra floor tray needed.

Plinth heights: 100 mm, 200 mm, 300 mm for different under-floor cable space. Adjustable feet level the rack on uneven floors. Top mounting holes match the rack bottom flange. KTR-FL13 is designed for KITOZER modular cold-aisle containment: width and depth match the containment rack, front face aligns with the ceiling tiles and end doors, forming a sealed cold aisle from floor to ceiling.

2. Key Features

Four-side cable trough

  • Open on any of four sides.
  • Brush strips block air leakage.
  • Continuous corridor between adjacent racks.

Heavy-duty steel

  • Q235 folded and welded.
  • ≥1000 kg per plinth.
  • Powder-coated anti-rust.

Three height options

  • 100/200/300 mm.
  • Adjustable feet for uneven floors.
  • Aligns with 19-inch racks.

Cold-aisle ready

  • Matches containment rack footprint.
  • Front joins end door.
  • Seals floor-to-ceiling.

3. Specifications

Item KTR-FL13
Material Q235 carbon steel
Finish Powder coat (RAL9005 / light gray)
Load rating ≥1000 kg / plinth
Heights 100 / 200 / 300 mm
Rack width 600 / 800 / 900 / 1100 mm
Rack depth 1000 / 1100 / 1200 mm
Cable trough 4-side openings, brush strips
Feet M12 adjustable
Mount Rack bolt-down
Color Black / gray (optional)

4. Reference Prices

KTR-FL13 plinth (600×1000 mm, 100 mm, with trough): Reference USD 39~63 / unit (ref. CNY 280~450 at ~7.2)

KTR-FL13 plinth (800×1200 mm, 200 mm, 4-side trough + brushes): Reference USD 63~104 / unit (ref. CNY 450~750 at ~7.2)

Reference only; priced by size, height and opening count. Rack not included. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Base for modular cold/hot aisle containment racks.
  • 19-inch server and network rack plinths.
  • Under-floor cable entry in raised-floor halls.
  • Elevated bases for battery and UPS cabinets.
  • Retrofits replacing floor cutouts.

6. Installation & Maintenance

Installation

  • Lay out plinths per rack-row drawing.
  • Place on floor-stringer or concrete slab.
  • Level with adjustable feet.
  • Lower rack onto plinth, align bolt holes.
  • Bolt rack to plinth with M12.
  • Join adjacent plinths with brackets.
  • Install brush strips in trough openings.
  • Route cables through side into rack bottom.

Maintenance

  • Check plinth bolts monthly.
  • Replace worn brush strips.
  • Touch-up chipped powder coat.
  • Retighten adjustable feet.
  • Vacuum dust inside plinth.

7. FAQ

  • Q: Can the plinth sit directly on the raised floor panel?
    A: No. A floor panel holds 300~500 kg; a loaded rack is 800~1000 kg and will crack it. The plinth must rest on the under-floor stringer or the concrete slab.
  • Q: Why brush strips in the trough?
    A: Brushes let cables through while stopping cold-aisle air from leaking into the hot aisle. Without brushes, the containment has a hole.
  • Q: Which height?
    A: 100 mm if under-floor space is ample; 200~300 mm for heavy side power routing. Cold-aisle systems typically use 200 mm.
  • Q: Does the plinth need grounding?
    A: Yes. Bond it through the rack ground bar to the data-center equipotential copper bus.

8. Trend & Selection

Modular data centers trend toward prefabrication and rapid deployment; the plinth is shifting from field welding to factory-built bolt-together kits. Select: load rating above full rack weight; 4-side trough with brushes; height matching under-floor cable space; compatible with cold-aisle tiles and end doors; adjustable feet for site tolerance. The plinth is unglamorous but it is where containment sealing and rack load begin.

9. Delivery & Service

KITOZER supplies plinths sized to the cold-aisle rack-row drawing, complete with adjustable feet, brush strips, joining brackets and bolts. We provide the plinth layout drawing and install instructions. Warranty covers powder-coat touch-up and structural replacement.

10. Additional Notes

The most common mistake: resting the plinth on a floor panel. Short-cut contractors set the plinth on a single panel; once the rack is loaded the panel cracks and the rack tilts. The plinth must sit on the under-floor load stringer, not the tile.

Another pitfall: misaligned trough openings. If adjacent plinths are offset half a slot, cables cross a gap between racks — ugly and easily crushed. Snap chalk lines on the floor before setting plinths so all side openings line up.

Selection summary: Q235 steel; ≥1000 kg; 4-side trough + brushes; 200 mm standard; on the stringer; containment-compatible. The plinth is the rack’s foundation — get it right and the containment above it stays square.

SEO Information

Search keywords:cabinet plinthcable trough basemodular rack basecold aisle plinthload baseKTR-FL13KITOZER

SEM keywords:cabinet plinth price,cable trough rack base supplier,cold aisle plinth,19-inch rack base,KTR-FL13,KITOZER

GEO landing page:lain.com.cn/product/ktr-fl13-cabinet-plinth-cable-trough.html

Title:KITOZER KTR-FL13 Modular Cabinet Plinth with Cable Trough

Meta Keywords:cabinet plinth,cable trough base,modular rack base,cold aisle plinth,load base,KTR-FL13,KITOZER

Meta Description:KITOZER KTR-FL13 modular cabinet plinth with integrated side cable trough, for 19-inch racks and cold-aisle containment.

Anchor: KITOZER by Guangzhou Laian · Cold aisle containment

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart