ToggleKITOZER KTR-FL4 Rack Plinth / Cabinet Joining Base
Brand:KITOZER Series:KTR-FL4 Category:Data Center Engineering / Rack infrastructure
Rack plinthJoining baseJoining kitCold aisleLoad base
1. Overview
When a row of racks stands side by side without being joined, seismic activity or maintenance bumps can shift and wobble the cabinets, opening gaps from head to tail and letting hot and cold air short-circuit through the cracks – defeating cold-aisle containment. A rack plinth (joining base) raises the row to leave room for under-floor cabling, air supply and refrigerant piping, while joining brackets lock the whole row into one rigid unit with no inter-rack gaps. Paired with roof tiles and end doors, it forms a contained cold aisle. In modular cold-aisle rooms, the plinth is the foundation of the rack row and the first sealing node.
The KITOZER KTR-FL4 is a rack joining plinth made from bent and welded cold-rolled steel, powder-coated, matched to cabinet width (600/800 mm) and depth (1000/1100/1200 mm). It has adjustable leveling feet for uneven floors; side joining plates and bolt holes let adjacent bases bolt together, and the base bolts to the cabinet uprights. Common heights are 100, 200 and 300 mm, balancing cable routing and airflow; cable tray cutouts and blanking plates prevent air short-circuit.
Selection depends on cabinet model, width/depth, cabling method (overhead/underfloor) and containment style (tile vs aisle enclosure). Joining hardware includes inter-rack plates, top joining beams and bottom sealing plates, supplied as a set. Load is calculated for a fully loaded row (including heavier battery and power distribution cabinets), typically >=1000 kg per cabinet.
2. Key Features
Structure & load
- Bent/welded cold-rolled steel, rigid whole-unit frame.
- >=1000 kg per cabinet; reinforced for battery racks.
- Adjustable feet, leveling range +/-20 mm.
- Bottom blanking plates stop air leakage.
Joining
- Side joining plates + bolts lock adjacent cabinets into a row.
- Bolts to cabinet uprights – no drilling or modification.
- Inter-rack gap <=2 mm with sealing strip.
- Supplied with inter-rack plates and top joining beams.
Finish & compatibility
- Powder-coated, RAL7035 or black.
- Compatible with mainstream 42U/47U racks.
- Reserved cable cutouts and tray interfaces.
- Height 100/200/300 mm options.
3. Specifications
| Item | KTR-FL4 Joining Plinth |
|---|---|
| Material | Cold-rolled steel, bent/welded |
| Finish | Powder-coated, RAL7035/black |
| Rack W x D | 600/800 x 1000/1100/1200 mm |
| Plinth height | 100 / 200 / 300 mm (custom) |
| Load | >=1000 kg/cabinet (battery version >=1500 kg) |
| Leveling feet | M12 adjustable, +/-20 mm |
| Joining | Side plates + bolts locking the row |
| Accessories | Inter-rack plates, top beams, bottom seals |
| Compatibility | 42U/47U standard 19-inch racks |
4. Reference Prices
KTR-FL4 standard plinth (600x1000x200 mm): Reference USD 49~90 (ref. CNY 350~650 at ~7.2)
KTR-FL4 joining hardware set (plates+bolts+seals): Reference USD 17~39 (ref. CNY 120~280 at ~7.2)
Reference only; final quote applies by rack count and row. 1-year warranty. Bulk pricing available. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Whole-row joining for modular cold-aisle racks.
- Raising racks for under-floor cabling and air supply.
- Reinforced plinths for heavy battery and PDUs.
- Retrofit joining and sealing of existing rooms.
- Seismic fixation of rack rows.
6. Installation & Maintenance
Installation
- Set out and position plinths per the row layout.
- Level with adjustable feet; align row top faces.
- Bolt adjacent bases into a row with joining plates.
- Set cabinets on plinths and bolt to uprights.
- Apply sealing strip; fit bottom blanking plates.
- Connect top joining beams; pair with tiles and end doors.
Maintenance
- Check and retorque joining bolts periodically.
- Re-apply fallen sealing strips to stop leakage.
- Keep cable cutouts blanked to avoid short-circuit.
- Watch foot settlement under heavy cabinets.
- Re-join and re-seal when adding or moving racks.
7. FAQ
- Q: Can’t racks just stand on the floor?
A: They can, but underfloor cabling needs elevation and cold-aisle containment needs gap-free rows. The plinth does both: elevation plus sealing. - Q: Which height to choose?
A: 200-300 mm for underfloor cabling/air; 100 mm for elevation/sealing only; match under-floor clear height and tray size. - Q: Do battery racks need reinforcement?
A: Yes. Battery banks weigh thousands of kg; use the reinforced plinth >=1500 kg with thicker feet. - Q: Can a single rack be removed after joining?
A: Yes. Unbolt the joining hardware and seals to pull one rack out without breaking the row. It is modular and detachable.
8. Trend & Selection
Modular cold aisles and micro-module rooms require whole-row joining, roof tiles, end-door enclosure and bottom sealing delivered as a set. Match plinth size/height to rack W/D and cabling; reinforce battery racks; supply bolts and seals as a kit; level the row before joining. The plinth is the invisible foundation that keeps the cold aisle from leaking.
9. Delivery & Service
KITOZER supplies plinths, joining plates, bolts, inter-rack seals and top beams as a set, matched to rack count, layout drawing and containment style. We support site survey and a joining layout drawing. Delivery includes plinths, hardware, seals, certificate and warranty card; the warranty covers joining installation guidance.
10. Notes
A common pitfall is leveling without joining. Free-standing racks leave gaps between cabinets; cold air short-circuits at the bottom and through rack gaps. Level the row, bolt it with plates, then seal.
Another pitfall is leaving cable cutouts unblanked. Cutouts exist for cables; empty holes without covers let hot/cold air short-circuit and cut cooling efficiency. Blank every unused hole.
Selection summary: powder-coated steel; matched to rack W/D; leveling feet; bolted row; inter-rack seals; reinforced battery version. It is the foundation of the rack row and the first line against air leakage.
Systemically, cold-aisle containment is a sealed system – roof tiles, end doors, rack gaps and bottom plinth. Any leak discounts the enclosure. The plinth and joining kit seal the bottom and the gaps.
Reliability-wise, a joined row resists sway and seismic shifts; maintenance bumps no longer misalign cabinets. An unjoined row sways like a chain and loosens terminals over time.
SEO Information
Search keywords:KITOZER
SEM keywords:rack plinth, cabinet joining base, rack joining kit, cold aisle containment plinth, KTR-FL4, KITOZER
GEO landing page:lain.com.cn/product/386-rack-floor-3.html
Title:KITOZER KTR-FL4 Rack Plinth / Cabinet Joining Base
Meta Keywords:rack plinth, cabinet joining base, rack joining kit, cold aisle containment plinth, KTR-FL4, KITOZER
Meta Description:KITOZER KTR-FL4 rack plinth and cabinet joining base, powder-coated steel, leveling feet, side joining brackets bolted into a row, with sealing plates, for modular cold-aisle rack rows.
Anchor: KITOZER by Guangzhou Laian · KITOZER products