ToggleKITOZER KTR-GEL150 12V150Ah Deep-Cycle Gel Battery
Brand: KITOZER Series: KTR-GEL150 Category: Power Distribution / Battery
12V150AhDeep-cycle gel12yr floatSealed VRLA
1. Overview
[‘The KITOZER KTR-GEL150 is a 12 V 150 Ah deep-cycle valve-regulated lead-acid (VRLA) battery using gel electrolyte, with a 12-year float design life (25°C), for UPS, DC panels and telecom backup. The 12 V block packages six 2 V cells in a flame-retardant ABS case; a single block gives 12 V, and blocks series into 24/48/192/240 V strings or parallel for more capacity. Deep-cycle means it survives thousands of cycles at 50% depth of discharge (DOD), suiting frequent outages, long backup and solar storage.’, ‘The KTR-GEL150 uses flat plates with gel electrolyte and AGM glass-mat separators. vs flooded cells, VRLA is sealed, leak-free, no watering, and mounts in any orientation except inverted; vs AGM starved-electrolyte, the gel electrolyte stays gelatinous with no stratification, longer deep-cycle life and lower self-discharge (~2%/yr). The flame-retardant ABS case has a top safety valve (10-30 kPa) that vents on overcharge and seals in normal service. M8 tinned-copper terminals give low resistance for high discharge. Size about 483×170×240 mm, weight ~45 kg. vs 2 V cells, the 12 V block installs simply with few cables, suiting small-to-mid UPS; vs 100 Ah it lasts longer on backup.’, ‘Typical deploy: a 60 kVA UPS with 192 V DC bus uses 16 KTR-GEL150 in series. The rack has two layers of eight, with M8 copper bus bars between blocks. After UPS startup set float 13.5-13.8 V/block (25°C), equalize 14.4-14.7 V. Keep the battery room at 20-25°C; every 10°C rise roughly halves float life. Full-load backup ~30 min (150 Ah×192 V÷60 kVA≈0.48 h after inverter efficiency). Select series count by UPS DC voltage, capacity by backup time, and 12 V block vs 2 V cells by space.’]
2. Key Features
Deep-cycle gel
- Gel electrolyte.
- 1000+ cycles @50% DOD.
- No stratification.
- ~2%/yr self-discharge.
12 V block
- Six 2 V cells.
- Flame-retardant ABS.
- 12 V per block.
- Series/parallel expand.
Long float life
- 12 yr design (25°C).
- Sealed VRLA.
- Safety vent.
- Maintenance-free.
High-current terminals
- M8 tinned copper.
- Low resistance.
- UPS discharge ready.
- 483×170×240 mm.
3. Specifications
| Item | KTR-GEL100 (12V100Ah) | KTR-GEL150 (12V150Ah) | KTR-GEL200 (12V200Ah) |
|---|---|---|---|
| Nominal voltage | 12 V | 12 V | 12 V |
| Nominal capacity | 100 Ah | 150 Ah | 200 Ah |
| Float design life | 12 yr | 12 yr | 12 yr |
| Float voltage | 13.5-13.8 V | 13.5-13.8 V | 13.5-13.8 V |
| Equalize voltage | 14.4-14.7 V | 14.4-14.7 V | 14.4-14.7 V |
| Weight | ~30 kg | ~45 kg | ~63 kg |
| Terminal | M8 copper | M8 copper | M8 copper |
4. Reference Prices
KTR-GEL150 12V150Ah gel battery: Reference USD 136 to 219 / unit (ref. CNY 980 to 1580 at ~7.2)
KTR-GEL100 12V100Ah gel battery: Reference USD 95 to 150 / unit (ref. CNY 680 to 1080 at ~7.2)
KTR-GEL200 12V200Ah gel battery: Reference USD 192 to 303 / unit (ref. CNY 1380 to 2180 at ~7.2)
Battery rack / busbar / breaker kit: Reference USD 14 to 69 / set (ref. CNY 100 to 500 at ~7.2)
Reference only; varies by config, quantity and scope. Install accessories billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- UPS backup.
- DC panel control power.
- Telecom backup.
- Solar storage.
- Long backup scenarios.
6. Installation & Maintenance
Installation
- Level the rack.
- Wire string per count.
- Torque M8 busbars.
- Check polarity.
- Set float voltage.
- Measure string voltage.
Maintenance
- Measure cell voltage quarterly.
- Keep room 20-25°C.
- Tighten terminals.
- Check for swelling.
- Annual capacity test.
- Recycle retired cells.
7. FAQ
- Q: Gel or AGM?
A: Choose gel for deep cycling, frequent discharges and solar; AGM suffices for pure float backup. Gel tolerates deep discharge better but costs a bit more. - Q: 12 V block or 2 V cells?
A: Small-to-mid UPS (≤100 kVA) use 12 V blocks for simple install; large/long-backup systems use 2 V cells for flexible parallel and single-cell replacement. - Q: How to size backup time?
A: Time ≈ total energy (Ah×V) ÷ load power, × inverter efficiency (~0.9). 150 Ah×192 V÷60 kVA≈0.48 h. - Q: How long do they last?
A: 12-year float design at 25°C; every 10°C rise roughly halves life. Battery-room temperature control is the key.
8. Trend & Selection
UPS backup moves from flooded cells to VRLA gel/AGM, with long life and maintenance-free as the trend. Set series count by UPS voltage, capacity by backup time, and choose gel for deep cycling. Battery-room temperature control and periodic capacity tests extend string life; retired cells recycle as hazardous waste.
9. Delivery & Service
KITOZER supplies battery packages: based on UPS power and backup time, we recommend capacity and series count plus racks, busbars, fuses and breakers. Bulk projects include factory capacity-test reports. Cells below 80% rated capacity under warranty are replaced free.
10. Additional Notes
The common mistake is poor battery-room temperature control. Above 30°C, life decays fast; run AC to hold ~25°C in summer—the highest-ROI life-extension step.
Another pitfall is under-torqued busbars. Loose M8 joints heat and arc under high discharge; torque to spec (~12 N·m) and mark the joint.
Selection summary: 12 V150 Ah; deep-cycle gel; 12-yr float; M8 copper terminals; maintenance-free VRLA. The KTR-GEL150 suits small-to-mid UPS and DC panels and tolerates frequent outages. Hold the room at 20-25°C, measure cell voltage quarterly, and recycle retired cells as hazardous waste.
Before commissioning, run a full capacity test to confirm at least 95% of rated capacity. A single cell reading low in service is usually a laggard—recharge or replace it before it drags the whole string. Leave airflow gaps between layers and insulate connectors to prevent short circuits.