KITOZER KTR-ODF-24S 24-Port SC Fiber Distribution Frame (2U Sliding)

KITOZER KTR-ODF-24S 24-Port SC Fiber Distribution Frame (2U Sliding)

Brand: KITOZER Series: KTR-ODF-24S Category: Fiber Distribution / ODF

2U 19 inch24-port SCslidingadapters+splice trayKTR-ODF-24S

1. Overview

The KITOZER KTR-ODF-24S is a 2U, 19-inch rack-mount 24-port SC fiber distribution frame (ODF) installed in standard racks for splicing, storing and patching backbone fiber. The ODF is the patching hub of a fiber link: the outside cable is spliced to pigtails inside the ODF, the pigtails are coiled in the rear splice tray, and the front adapters mate with patch cords that run to switch ports. One 24-port ODF terminates 24 fibers.

KTR-ODF-24S is made of 1.2 mm cold-rolled steel with black powder coat, in a sliding drawer design (pull out for splicing, push in for a neat dust-protected rack). The front panel holds 24 SC simplex adapters (single-mode blue or multimode beige); the rear has two splice trays (12 fibers each, total 24), with coil rings ensuring a 30 mm bend radius. The outside cable enters through a rear gland, is clamped by a cable retainer, and the strength member is bonded to a ground lug. Adapters line the front panel with numbered labels.

Typical uses: data center backbone patching (two ODFs per TOR, one active one standby); building telecom room floor aggregation; carrier central office cable termination; factory fiber ring networks; campus dorm fiber aggregation. KTR-ODF-24S is the most-used fiber termination unit.

2. Key Features

2U 24-port

  • 2U 19-inch rack mount.
  • 24 SC simplex ports.
  • Includes 24 SC adapters.
  • Includes 2 splice trays (12 fibers each).

Sliding drawer

  • Drawer pull-out for work.
  • Dust-protected when pushed in.
  • Ball-bearing slides.
  • Locking screw.

Splice & storage

  • Splice tray 12 fibers each.
  • Coil ring R30 bend radius.
  • Cable retainer clamp.
  • Strength-member ground lug.

Build

  • 1.2 mm cold-rolled steel.
  • Black powder coat.
  • Removable adapter panel.
  • Port number labels.

3. Specifications

Item Parameter
Model KTR-ODF-24S
Size 2U 19-inch rack mount
Ports 24 SC simplex
Adapters SC single-mode UPC (blue) or multimode (beige)
Splice trays 2 (12 fibers each, total 24)
Structure Sliding drawer
Sheet 1.2 mm cold-rolled steel
Finish Black powder coat
Dimensions about 482x88x250 mm (WxHxD)
N.W. about 4.5 kg
Cable entry 2 rear glands
Bend radius 30 mm (coil ring)
Fiber type SM 9/125 or MM 50/125 / 62.5/125
Mounting 19-inch rack M6 cage nuts

4. Reference Prices

KTR-ODF-24S 2U 24-port SC ODF (with adapters+trays): Ref. USD 25~39 / pc (CNY 180~280 at 7.2)

KTR-ODF-48S 3U 48-port SC ODF: Ref. USD 44~67 / pc (CNY 320~480 at 7.2)

KTR-ODF-LC24 2U 24-port LC duplex (48 fibers): Ref. USD 36~56 / pc (CNY 260~400 at 7.2)

KTR-ODF-MPO 1U MPO-LC cassette (12 fibers): Ref. USD 63~97 / pc (CNY 450~700 at 7.2)

SC single-mode pigtail (1.5 m): Ref. USD 1~2 / pc (CNY 8~15 at 7.2)

Splice tray (12 fibers, spare): Ref. USD 2~3 / pc (CNY 15~25 at 7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data center backbone patching.
  • Building telecom room aggregation.
  • Carrier CO cable termination.
  • Factory fiber ring network.
  • Campus dorm fiber aggregation.

6. Installation & Maintenance

Installation

  • Fix the sliding chassis to 19-inch posts with M6 cage nuts.
  • Route the outside cable in from the rear through the gland.
  • Strip 30 cm of outer jacket, exposing strength member and 24 tubes.
  • Clamp the strength member and bond to the ground lug.
  • Splice each fiber to an SC pigtail (12 per tray, 2 trays).
  • Coil spliced pigtails on the ring (bend radius 30 mm).
  • Plug SC pigtail tails into the rear of the front adapters.
  • Push in the ODF; patch to switches from the front.
  • Label each port (number + far end).

Maintenance

  • Check front labels monthly.
  • Press the latch to unplug patch cords; never pull the cord.
  • Cap unused ports.
  • Check splice trays quarterly.
  • Do not stack items on the ODF.
  • For reroutes, move patch cords only; do not touch rear splices.

7. FAQ

  • Q:SC, LC or FC ODF?
    A:Density: LC highest (24 duplex = 48 fibers in 2U), SC next (24 simplex = 24 fibers in 2U), FC lowest (12 fibers in 2U). New data centers choose LC duplex (KTR-ODF-LC24); buildings and carriers traditionally use SC (KTR-ODF-24S); industrial test gear uses FC. Do not mix connector types without an adapter.
  • Q:ODF vs fiber terminal box?
    A:The ODF (KTR-ODF-24S) is rack-mount (in the rack), high port count (24), sliding, for data centers and telecom rooms. The fiber terminal box is wall-mount, few ports (4 to 12), plastic, for FTTH corridors and low counts. Data centers use ODF; FTTH uses terminal boxes.
  • Q:Which has higher loss, splice or connector?
    A:Fusion splice loss is small (under 0.05 dB); connector (adapter) loss is larger (0.2 dB). One link: outside cable spliced to pigtail (0.05 dB) + adapter (0.2 dB) + patch cord to switch (0.2 dB) + adapter (0.2 dB) = about 0.65 dB. So splice carefully; a splice above 0.1 dB should be redone. Test with a power meter after splicing.
  • Q:How to secure the cable in the ODF?
    A:The outside cable has a strength member (aramid or steel); it must be clamped to the ODF cable retainer. If not clamped, pulling a patch cord tugs the splice point and breaks it. Bond the strength member to the ODF ground lug (lightning protection). Also tie the outer jacket. Do not leave the cable floating and stressed.

8. Trend & Selection

ODFs move from SC simplex to LC duplex/quad (double density). MPO/MTP pre-terminated cables replace field splicing in data centers (factory-terminated, plug-and-play on site, saving splicing time). ODFs move from fixed metal frames to modular (swappable port cassettes). Smart ODFs (electronic labels record every fiber connection) grow in large data centers. High-density ODFs (1U 96 fibers LC) spread in 40G/100G centers.

9. Delivery & Service

KITOZER sizes KTR-ODF-24S by fiber count and connector type, providing ODF layouts and label templates. Delivery includes ODF chassis, 24 SC adapters, 2 splice trays, cable retainer and certificate. Warranty covers splicing guidance and label printing support.

10. Additional Notes

A common pitfall is messy splice trays. Installers stuff 24 fibers into the tray without order, with bend radius under 30 mm, causing high loss and no way to trace fibers later. Route each fiber in order around the coil ring, leave 1 m slack, and label to match the adapter port.

Another pitfall is missing dust caps. 24 open ports during construction collect dust in a week; insertion loss rises from 0.15 dB to 0.5 dB. Cap unused ports and clean with a fiber pen before use.

Selection summary: 2U; 24 SC; sliding; with adapters and splice trays; 19-inch. The ODF is the patching hub of the fiber link; the keys are low splice loss, adequate coil bend radius, clamped cable strength member, and clear port labels.

Additional tip: Do not yank the sliding drawer. The slides have a travel stop and lock before fully pulling out. To remove the drawer completely, press the release tab on the slide. For daily splicing, pull to the work position only.