ToggleKITOZER KTR-OILCYC Cyclone Oil Separator (Compressed Air)
Brand: KITOZER Series: KTR-OILCYC Category: Compressed Air Treatment / Oil Separator
cyclone1.0 MPa99% removalDN25-DN80KTR-OILCYC
1. Overview
The KITOZER KTR-OILCYC is a cyclone oil-gas separator. Compressed air enters tangentially and spins at high speed; centrifugal force throws oil and water droplets against the wall, they slide down into the sump and drain through an auto drain valve. Compared with filter-element separators, the cyclone needs no element replacement, has low pressure drop and minimal maintenance, suited for compressor after-treatment, pneumatic lines, spraying and blow-off systems as primary liquid separation.
KTR-OILCYC works at 1.0 MPa (optional 1.6 MPa), with flange ports DN25, DN40, DN50, DN65 and DN80 covering 1.2 to 12 cubic meters per minute. Carbon-steel shell sand-blasted and epoxy-coated, internal stainless-steel swirl vanes, sump with float-type auto drain. Removal efficiency: 99% on droplets 5 micron and above, about 85% on 1 micron. Outlet residual oil about 5 to 10 mg per cubic meter, used as pre-treatment before fine filters.
Typical uses: main compressor outlet water and oil removal; spray-shop primary compressed-air purification; liquid-water discharge in pneumatic tool lines; blow-molding and blow-off oil-mist separation; pre-separation before refrigerated or desiccant dryers. The cyclone separates only liquid oil and water droplets; vapor-phase oil mist needs downstream activated-carbon filtration.
2. Key Features
Cyclone principle
- Tangential inlet creates swirl.
- Centrifugal force throws out liquid droplets.
- No element, no consumable.
- Low pressure drop under 0.02 MPa.
Coated steel shell
- Sand-blasted and epoxy coated.
- Stainless-steel internal swirl vanes.
- Working pressure 1.0 MPa.
- Flange inlet and outlet.
Auto drain
- Sump with float drain valve.
- Auto discharge at level.
- Optional electronic timed drain.
- Transparent hose at outlet for observation.
Multiple sizes
- DN25 to DN80 flanges.
- Flow 1.2 to 12 cubic m/min.
- Vertical installation.
- Pressure gauge ports.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-OILCYC |
| Principle | Cyclone centrifugal |
| Working pressure | 1.0 MPa (1.6 MPa optional) |
| Design temperature | up to 66 C |
| Flow range | 1.2 to 12 cubic m/min by port |
| Port size | DN25/40/50/65/80 flange |
| Removal efficiency | 99% above 5 um; about 85% at 1 um |
| Outlet oil content | about 5 to 10 mg/cu m |
| Pressure drop | under 0.02 MPa |
| Shell material | carbon steel epoxy coated, SS vanes |
| Drain | float auto drain (electronic timed optional) |
| Mounting | vertical, bracket fixed |
4. Reference Prices
KTR-OILCYC DN25 (1.2 cu m/min):Ref. USD 49~69 / unit (CNY 350~500 at 7.2)
KTR-OILCYC DN50 (6 cu m/min):Ref. USD 83~125 / unit (CNY 600~900 at 7.2)
KTR-OILCYC DN80 (12 cu m/min):Ref. USD 153~222 / unit (CNY 1100~1600 at 7.2)
Float drain valve (spare):Ref. USD 4~8 / pc (CNY 30~60 at 7.2)
Electronic timed drain (option):Ref. USD 11~21 / pc (CNY 80~150 at 7.2)
Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Compressor main outlet water/oil removal.
- Spray-shop primary air purification.
- Liquid-water discharge in pneumatic lines.
- Blow-molding and blow-off oil separation.
- Pre-separation before dryers.
6. Installation & Maintenance
Installation
- Install vertically downstream of compressor, before dryer.
- Inlet to upstream, outlet to downstream filter or dryer.
- Follow arrow on shell (inlet top, outlet bottom).
- Connect transparent drain hose under sump to oil bucket.
- Use gauge ports to monitor pressure drop.
- Check drain valve operation on first start.
- Slope drain line downward to avoid back-up.
- Drain sump regularly and record discharge.
Maintenance
- Check sump drain weekly.
- Inspect float valve for sticking monthly.
- Open shell and inspect vanes quarterly.
- Clean shell and vanes yearly.
- Watch gauges; clean if drop exceeds 0.05 MPa.
- Replace float drain valve if it leaks.
7. FAQ
- Q:Cyclone vs filter-element separator?
A:The cyclone uses centrifugal force to remove large liquid droplets, has no element, low pressure drop and no consumables, but only handles droplets 5 micron and above, outlet oil about 5 to 10 mg/cu m. Element (fine) filters use fiber media to capture down to 0.01 micron, residual oil 0.01 mg/cu m, but need periodic element changes and higher pressure drop. Usually the cyclone is pre-treatment and the fine filter is terminal, two stages in series. - Q:Can the cyclone remove vapor oil mist?
A:No. The cyclone removes only liquid oil and water droplets; oil vapor molecules from the compressor cannot be separated by centrifugal force. To reach oil-free level (0.01 mg/cu m), add an activated-carbon adsorber after the cyclone. The carbon absorbs vapor oil, but saturates and needs replacement every 6 to 12 months. - Q:Drain valve leaks air constantly, what to do?
A:A leaking float drain usually means dirt or oil sludge is jamming the seal, so the float cannot close fully. Shut the upstream valve, remove the drain, and clean the float and seat with kerosene or compressed air. If the seal is worn, replace the float drain (30 to 60 RMB each). Do not force it closed, which can damage the float. - Q:Does mounting direction matter?
A:Yes. KTR-OILCYC must be vertical, inlet at top and outlet at bottom (or follow the arrow), with the tangential inlet at the top. Reversed or horizontal mounting destroys the swirl and cuts efficiency. Anchor the shell with brackets to floor or platform, and support the pipes independently so the flanges do not carry pipe weight and leak.
8. Trend & Selection
Compressor after-treatment is moving toward integrated skids (cyclone plus fine filtration plus drying), with small side-stream cyclones common at compressor outlets. Energy saving drives low pressure-drop designs; optimized vanes cut drop from 0.05 to 0.02 MPa. Smart drains (electronic timed plus level) replace float drains to reduce air loss. In spray, electronics and pharma, cyclone plus activated-carbon two-stage is becoming standard.
9. Delivery & Service
KITOZER sizes KTR-OILCYC by compressor rated flow and port, provides installation drawings and flange standards. Delivery includes separator body, mounting bracket, float drain valve and certificate. Warranty covers commissioning and spare drain supply.
10. Additional Notes
A common pitfall is connecting pneumatic tools directly after the cyclone. Cyclone outlet still has 5 to 10 mg/cu m oil, which is not enough for spraying and electronics; a fine filter (0.01 micron) and activated-carbon filter must follow. The cyclone solves only liquid water and large oil droplets, not oil-free requirements.
Another pitfall is neglecting the drain. Sludge and rust can jam the float, causing the drain to stay open (air leak) or closed (sump overflow). Manually press the drain weekly to test for hissing. If the sump fills, liquid is re-entrained downstream and the separator does nothing.
Selection summary: cyclone, no element, 1.0 MPa, DN25 to DN80, auto drain. The cyclone is the first liquid-water defense in the compressed-air line: low drop, low maintenance, but remember it removes liquid only, not vapor, so terminal purity needs elements and carbon.
Additional tip: install pressure gauges at inlet and outlet. Initial drop is 0.01 to 0.02 MPa; if it rises over time, the inner wall and vanes are coated with oil sludge and need cleaning. When differential pressure exceeds 0.05 MPa, shut down and clean, otherwise resistance rises and compressor power climbs.