ToggleProduct Overview
The KITOZER 16A high-accuracy metered PDU is a 1U power distribution unit focused on precision energy measurement for billing and compliance. It measures voltage, current, active power, reactive power, apparent power, power factor, frequency, and accumulated energy with 1 percent class accuracy, making it suitable for co-location tenant billing, energy audit reporting, and sustainability dashboard integration. Eight IEC C13 outlets provide connectivity for servers, switches, and storage. A local LCD displays the key readings, and Ethernet connectivity enables remote data collection into DCIM or building management systems. The unit is engineered for steady 24 by 7 operation with minimal drift.
The metering engine uses a high-precision analog front end with temperature compensation, so accuracy holds across the full operating temperature range. The unit stores a full year of 15-minute interval data in non-volatile memory, which means it can operate as a stand-alone data logger even if the central monitoring server is offline. The data can be exported as a CSV file through the web interface for later analysis in spreadsheet or energy management software.
Technical Specifications
Input: single phase 200 to 240VAC, 50 or 60Hz, rated 16A. Output: eight IEC C13 outlets. Metering class: 1.0 for active energy, 1.0 for active power, per IEC 62053-21. Measurements: voltage, current, kW, kVar, kVA, kWh, power factor, frequency, demand. Communication: 10 or 100Mbps Ethernet, Modbus TCP, SNMP v2c, HTTP, HTTPS. Data logging: 1 second sampling rate, up to 1 year of trend data in internal memory. Display: backlit LCD. Alarms: over-current, over-voltage, under-voltage, via email and SNMP trap. Mechanical: 1U 19-inch rack, steel chassis, dimensions 482 x 44 x 260 mm, weight 2.6 kg. Safety: CE, MID, RoHS. Brand: KITOZER. Warranty: 3 years.
The demand measurement window is user-selectable at 5, 15, 30, or 60 minutes to match local utility billing intervals. A resettable trip counter logs the maximum demand reached in the current month. The Modbus register map is provided in a downloadable document, so BMS engineers can map points without guesswork. The LCD can be configured to cycle through readings or to hold on a single measurement. The unit supports up to 10 user accounts with read and write permissions.
Application Scenarios
This metered PDU is deployed wherever accurate energy data has direct financial or regulatory value: co-location tenant billing, green building energy dashboards, government-mandated energy reporting, research lab power measurement, and financial branch server room accountability. It is also used in pilot projects comparing energy use before and after server virtualization or airflow optimization. Because the unit logs trend data internally, it can operate as a stand-alone logger even if the central monitoring platform is offline, and data can be retrieved later when the network is restored.
University facilities departments use the PDU to allocate energy cost between departments in shared computer rooms. Hospitals use it to track power use of MRI and CT scanners, which is required for equipment efficiency studies. Data center operators use the per-rack energy data to right-size UPS and generator loads during capacity planning. Retail chains compare energy use across branches to identify outliers that may have failing air conditioners or overloaded servers. In every case, the 1 percent accuracy means the numbers are trusted by finance teams and auditors.
Advantages and Benefits
The 1 percent accuracy class ensures billing-grade measurements that tenants accept without dispute. Built-in trend logging removes the need for separate data loggers. Modbus TCP and SNMP support means the PDU drops into existing BMS and DCIM architectures without additional protocol gateways. The unit is competitively priced compared with external revenue-grade meters plus separate PDUs, reducing both hardware cost and panel space. Local display allows verification without software, which speeds troubleshooting during maintenance windows.
The internal memory means data is never lost during a network outage, which is a major advantage over cloud-only metering solutions. The MID-certified variant is acceptable for commercial sub-billing in markets that require it. The demand measurement helps facilities engineers predict demand charges before they appear on the utility bill. The unit also measures power factor and reactive power, which is useful for sites that face power factor penalties. Because the PDU itself is the meter, there is no additional current transformer to calibrate or mount.
Installation and Maintenance Recommendations
For billing applications, seal the input wiring compartment and record the initial meter reading in the project handover document. Configure the Modbus register map to match the upstream BMS point list before go-live. Set the demand interval to match the utility billing interval so demand charges can be predicted. Periodically compare the PDU reading against a calibrated reference meter; if drift exceeds 1 percent, return the unit for factory recalibration. Keep the firmware updated to maintain security and protocol compatibility. Store trend data exports in the central energy database for audit purposes.
Label the PDU with the tenant name and billing period. Place the LCD where it can be read during a meter-reading walk. Do not share the PDU between tenants without installing separate metering per tenant, because the 1 percent accuracy only applies to the whole unit. When the unit is replaced, transfer the accumulated energy reading to the new PDU configuration so billing continuity is preserved. Keep the calibration certificate on file for audit. Because the unit is precision equipment, avoid mounting it directly next to large transformers or variable frequency drives, which can introduce magnetic interference.
Price
From $240 per piece. Contact KITOZER for MID-certified billing variants and three-phase models.