The KITOZER Modular UPS 200kVA is a high-capacity online system delivering 200kW at power factor 1.0 for large data centers, enterprise IT, and industrial critical loads. Each hot-swappable power module is 25kVA or 25kW, and the frame accepts up to 8 modules for 200kVA capacity with N+X redundancy. The architecture supports parallel frames for even larger systems, allowing operators to scale to multi-megawatt deployments while maintaining redundancy. The integrated bypass, intelligence module, and color touchscreen provide comprehensive monitoring.
Built for mission-critical data centers, the KITOZER 200kVA modular UPS uses heavy-duty IGBT stacks with redundant forced-air cooling. Transformer-less high-frequency topology achieves 96.5 percent online efficiency. Input power factor correction greater than 0.99 and THDi less than 3 percent protect upstream infrastructure. The wide input range from 304 to 478VAC rides through deep sags without battery switching.
The unit is CE certified and complies with IEC 62040 safety and EMC standards. The intelligence module handles monitoring, communication, and parallel load sharing across modules and frames. The 10-inch color touchscreen displays real-time metering, event log, and waveform capture. Native Modbus TCP and SNMPv3 integration fits DCIM platforms. The integrated maintenance bypass allows safe service without load interruption.
Technical Specifications
Frame capacity 200kVA, module rating 25kVA or 25kW PF 1.0. Input 380, 400, or 415V three phase, range 304 to 478VAC, input PF greater than 0.99, THDi less than 3 percent. Output 380, 400, or 415V three phase, online efficiency 96.5 percent. Up to 8 modules per frame. Hot-swap modules. Parallel frames supported. External battery cabinet for long runtime.
Communications: Modbus TCP, SNMPv3, Web HMI, USB, dry contacts. 10-inch touch LCD. Dimensions 1000 by 1200 by 2000 mm, weight 1500 kg frame. IP20 cabinet. Operating temperature 0 to 40 degrees Celsius. Noise level less than 70 dB(A). Event log stores 2048 records. Three-year standard warranty.
Application Scenarios
Deployments include large data centers, colocation facilities, financial trading floors, hospital central plants, and semiconductor fabs. Parallel frames allow multi-megawatt redundancy. External battery cabinets bridge generator start-up or support orderly shutdown.
Additional applications include government data centers, cloud data centers, large manufacturing plants, and pharmaceutical facilities. The modular architecture supports pay-as-you-grow from 25 to 200kVA per frame. The wide input window allows deployment in regions with unstable grid voltage. The N+X configuration meets tier-class uptime requirements.
Key Advantages
Modular pay-as-you-grow scales from 25 to 200kVA per frame. N+X redundancy within and across frames. Hot-swap modules reduce service time to minutes. 96.5 percent efficiency lowers energy cost. Low THDi protects upstream infrastructure.
Integrated maintenance bypass. Comprehensive DCIM integration. Redundant fan cooling increases reliability. Color touchscreen and event log reduce troubleshooting time. CE certified for global deployment. Three-year standard warranty.
Installation and Maintenance Advice
Install on reinforced concrete floor. Coordinate upstream switchgear with UPS fault rating. For parallel frames, use dedicated paralleling cables and identical firmware. Battery cabinet cables must be fused.
Keep spare power module on site. Test modules every 6 months. Annual preventive maintenance by qualified electrician. Keep spare fans and contactors on site. Label bypass positions clearly.
Price
From $68,000 per frame. Power modules, battery cabinet, and parallel options quoted separately. Contact KITOZER factory for bulk pricing.