The KITOZER Modular UPS 60kVA is a high-density online system delivering 60kW at power factor 1.0 for mid-size data centers and critical IT rooms. Each hot-swappable power module is 15kVA or 15kW, and the frame accepts up to 4 modules for 60kVA capacity with N+1 or N+X redundancy. The architecture allows operators to start with 30kVA and scale to 60kVA as load grows, while maintaining redundancy throughout. The integrated bypass, intelligence module, and large touchscreen simplify management and troubleshooting.
Built for enterprise data centers, the KITOZER 60kVA modular UPS uses transformer-less high-frequency topology with IGBT inverter technology and DSP control. Input power factor correction greater than 0.99 and THDi less than 3 percent ensure IEEE 519 compliance. The wide input range from 304 to 478VAC rides through deep sags without battery switching. Hot-swappable power modules can be replaced during operation without powering down the load.
The unit is CE certified and complies with IEC 62040 safety and EMC standards. The intelligence module handles monitoring, communication, and parallel load sharing. The 7-inch color touchscreen displays real-time input, output, load per module, battery status, and event history. Native Modbus TCP and SNMPv3 integration fits DCIM platforms without add-on cards. The integrated maintenance bypass allows safe service without load interruption.
Technical Specifications
Frame capacity 60kVA, module rating 15kVA or 15kW PF 1.0. Input 380, 400, or 415V three phase, range 304 to 478VAC, input PF greater than 0.99, THDi less than 3 percent. Output 380, 400, or 415V three phase, online efficiency 96.5 percent. Up to 4 modules per frame. Hot-swap modules. External battery cabinet supports long runtime.
Communications: Modbus TCP, SNMPv3, Web HMI, USB, dry contacts. 7-inch color touch LCD. Dimensions 600 by 1000 by 1600 mm, weight 450 kg frame. IP20 cabinet. Operating temperature 0 to 40 degrees Celsius. Noise level less than 65 dB(A). Event log stores 1024 records. Three-year standard warranty.
Application Scenarios
Common deployments include enterprise data centers, cloud edge nodes, hospital IT, manufacturing execution systems, and large corporate offices. The modular design is chosen when load growth is expected but upfront capital must be minimized. Hot-swap modules allow expansion during operation without powering down critical loads.
Additional use cases include government data centers, financial back offices, media production servers, and university computer labs. External battery cabinets provide 30 minutes to several hours of backup for sites without generators. The N+X configuration provides redundancy without external STS. The wide input window allows deployment in regions with unstable grid voltage.
Key Advantages
Pay-as-you-grow scales from 30 to 60kVA. N+X redundancy within frame. Hot-swap power modules reduce service time. 96.5 percent efficiency lowers energy cost. Low THDi protects upstream grid.
Integrated maintenance bypass. Comprehensive DCIM integration. Color touchscreen and event log reduce troubleshooting time. Wide input window rides through sags and swells. CE certified for global deployment. Three-year standard warranty.
Installation and Maintenance Advice
Install on reinforced concrete floor. Slide modules into slots until latched. Use external battery cabinet with fused cables. Keep firmware identical across modules.
Keep spare module on site. Test modules every 6 months. Maintain ambient 20 to 25 degrees Celsius. Annual preventive maintenance by qualified technician. Label bypass positions clearly.
Price
From $18,500 per frame. Power modules and battery cabinet quoted separately. Contact KITOZER factory for bulk pricing.