Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

KITOZER Outdoor Railway Communication Cabinet

KITOZER Outdoor Railway Communication Cabinet Quotation List

2. Project Requirement Description

Designed for railway lines, stations, grade crossings, and similar scenarios, the outdoor railway communication cabinet provides dedicated outdoor protective enclosures for railway communication signal equipment, transmission equipment, and power supply equipment. The solution must meet the railway industry’s high-reliability, strong seismic resistance, wide temperature range, and anti-interference standards, while supporting unattended operation in harsh environments along railway lines, ensuring the stable and reliable operation of railway communication signal systems.

Key requirements include:

  • High-reliability protective enclosure for railway communication and signal equipment
  • Strong seismic resistance to withstand train-induced vibrations and shocks
  • Wide temperature range operation capability for diverse climate zones
  • Electromagnetic interference resistance in railway environments
  • Unattended operation capability for remote railway sites
  • Compliance with railway industry technical standards

3. System Composition Introduction

The complete railway communication cabinet system consists of six major modules:

Module Description
High-Strength Cabinet Body Heavy-duty enclosure with thermal insulation
Industrial Temperature Control Unit Precision cooling/heating system
Railway-Specific Power Distribution Unit Dual-power input with automatic switching
Environmental Monitoring Unit Remote monitoring and alarm system
Lightning Protection & Grounding Unit Comprehensive surge and grounding protection
Seismic Mounting Unit Specialized anti-vibration installation components

Optional railway-specific accessories include:

  • Battery backup power unit
  • Fiber optic distribution unit
  • Signal lightning protection modules

4. Core Product Specifications & Parameters

Parameter Category Technical Specification
Cabinet Dimensions H2000mm × W600mm × D600mm, floor-standing, 19-inch standard rack, 40U usable space
Cabinet Material 2.0mm high-quality cold-rolled steel plate, double-layer structure, polyurethane thermal insulation, anti-corrosion sprayed surface, railway gray
Protection Rating IP55, dust-proof, waterproof, salt-spray resistant, suitable for railway lines, tunnel entrances, station yards
Seismic Performance Complies with TB/T 3553 railway equipment seismic standards, seismic intensity 9, withstands train vibration impact
Temperature Control System 1000W industrial air conditioner, wide-temperature operation, stable operation from -40°C to +70°C, cabinet interior maintained at 10~35°C
Power Distribution System DC48V/AC220V dual-mode, dual-input automatic switching, compliant with railway power supply specifications
Electromagnetic Compatibility Complies with TB/T 3498 railway EMC standards, resistant to strong electromagnetic interference
Monitoring System Environmental monitoring unit, supports railway private network transmission, alarm information integrated into comprehensive network management

5. Core Functions & Features of Products

Equipment Protection Function:

  • Dust-proof, waterproof, and anti-corrosion protection for railway communication and signal equipment
  • Adapts to complex environments along railway lines

Constant Temperature Environment Assurance:

  • Industrial-grade temperature control system
  • Handles severe cold in Northeast China, high temperatures in Northwest China, and high salt-spray conditions in coastal areas

Reliable Power Supply Function:

  • Dual-power automatic switching
  • DC/AC dual-mode configuration
  • Compliant with railway power supply standards, ensuring uninterrupted communication

Seismic and Anti-Interference Function:

  • Specialized seismic mounting structure
  • Electromagnetic shielding design
  • Withstands train vibrations and electromagnetic interference

Remote Monitoring Function:

  • Environmental monitoring integrated into railway network management
  • Remote monitoring of cabinet interior status
  • Proactive fault alarms, suitable for unattended operation

Standard Compatibility Function:

  • Complies with relevant railway technical standards
  • Compatible with mainstream railway communication and signal equipment installation

6. Core Advantages of The Solution

High Industry Compliance:

  • Fully compliant with railway equipment technical standards
  • Direct integration with railway communication network management systems

Extremely High Reliability:

  • Reinforced design specifically for railway scenarios
  • Mean time between failures (MTBF) ≥ 150,000 hours
  • Meets railway high-reliability requirements

Wide Environmental Adaptability:

  • Suitable for cold-region railways, coastal railways, and plateau railways
  • Wide-temperature and wide-voltage design

High Maintenance Efficiency:

  • Standardized modular design for quick replacement of faulty components
  • Reduces maintenance time within railway maintenance windows

Flexible Customization:

  • Customizable dimensions, compartment quantities, and power supply modes based on site equipment configuration
  • Adaptable to different railway line requirements

7. Manufacturer Strength Introduction

KITOZER / Guangzhou Lai’an Intelligent System Development Co., Ltd.

  • Founded in 2002, with over 20 years of industry experience
  • ISO 9001 Quality Management System Certified
  • ISO 14001 Environmental Management System Certified
  • ISO 45001 Occupational Health and Safety Management System Certified
  • Recognized High-Tech Enterprise
  • Project-confirmed manufacturing capabilities
  • Complete quality inspection procedures before shipment
  • Professional R&D team dedicated to continuous product innovation
  • Proven track record serving railway, telecommunications, and industrial sectors

8. Detailed Quotation Table

No. Product Name Model & Spec Technical Parameter Qty Unit Unit Price (USD) Total Price (USD) Brand Remark
1 Railway Communication Cabinet KTZ-RC-6020 2000×600×600mm, 2.0mm steel plate, double-layer insulation, IP55, 40U rack 1 Set 1154.36 1154.36 KITOZER Includes seismic base, rain-proof top, anti-theft lock
2 Industrial Cabinet Air Conditioner KTZ-KT-1000 Cooling capacity 1000W, heating capacity 600W, wide-temperature operation, AC220V 1 Set 577.18 577.18 KITOZER Side-mounted, railway-specific high-reliability type
3 Railway Power Distribution Unit KTZ-PD-RL Dual-input automatic switching, DC48V/AC220V output, with graded protection 1 Set 355.19 355.19 KITOZER Compliant with railway power supply specifications
4 Environmental Monitoring Unit KTZ-FSU-RL Temperature/humidity, door access, voltage, current monitoring; supports railway private network protocol 1 Set 443.98 443.98 KITOZER Interface compatible with railway integrated network management
5 Power Lightning Protection Module KTZ-LY-B60 Class B lightning protection, nominal discharge current 60kA, railway-specific type 1 Set 177.59 177.59 KITOZER Protection for power input terminals
6 Signal Lightning Protection Unit KTZ-LY-XH Railway signal-specific lightning protection, nominal discharge current 10kA 4 Pcs 66.60 266.39 KITOZER Protects signal transmission ports
7 Seismic Mounting Kit KTZ-ZJ-KZ Seismic base, equipment vibration-damping fixings, anti-loosening screws 1 Set 133.20 133.20 KITOZER Meets railway seismic requirements
8 Grounding Equipotential Kit KTZ-JD-RL Main grounding bar, equipotential bonding wires, grounding terminals 1 Set 88.80 88.80 KITOZER Compliant with railway grounding specifications

Total Quotation Price: USD 3196.69

9. Quotation Terms & Conditions

1. Price Basis: All prices quoted in USD, EXW Guangzhou, China (or as negotiated).

2. Tax: The above prices exclude taxes and freight. A 10% surcharge applies for VAT special invoices; a 3% surcharge applies for VAT regular invoices.

3. Shipping: Delivery via logistics, freight collect (payable at destination). Delivery to designated railway station warehouses is available.

4. Payment Terms: 30% deposit with order, 70% balance before shipment (negotiable for specific projects).

5. Lead Time: 15-30 working days depending on configuration and order quantity.

6. Quotation Validity: This quotation remains valid for 30 days from the date of issue.

7. Customization: Custom configurations based on specific railway line requirements are available; third-party testing and certification costs are quoted separately.

8. Packing: Standard export packing included; special packing requirements quoted separately.

10. After-sales Service Description

KITOZER is committed to providing comprehensive after-sales support:

  • Warranty Period: 3 years product warranty (12-24 months standard, extended to 3 years for this railway series)
  • Lifetime Technical Support: Free technical consultation and support for the product’s entire service life
  • Spare Parts Availability: Long-term spare parts supply ensuring rapid replacement
  • Remote Troubleshooting: Remote diagnostic and troubleshooting services via phone, email, or video conference
  • On-site Service: On-site installation guidance, commissioning support, and maintenance services available
  • Training: Technical training for operation and maintenance staff can be arranged upon request

11. Contact & Order Information

To place an order or request more information, please contact the KITOZER sales team:

  • Official Website: www.gdlain.com
  • Company Name: Guangzhou Lai’an Intelligent System Development Co., Ltd. / Guangdong Lai’an Intelligent Data Center Equipment Co., Ltd.
  • Brand: KITOZER
  • Contact Person: Mr. Zhou
  • Order Process: Submit inquiry via official website or contact sales team directly; all inquiries receive a response within 24 hours
  • Customization Requests: Contact our engineering team with your specific railway line requirements for tailored solutions

12. SEO Keywords & Tags

KITOZER outdoor railway communication cabinet quotation, railway communication cabinet price list, outdoor railway communication cabinet factory price, railway signal equipment cabinet, railway-specific outdoor cabinet, seismic railway communication cabinet, railway line communication cabinet, station signal equipment cabinet, railway outdoor equipment enclosure, KITOZER railway cabinet, railway cabinet manufacturer China, railway communication cabinet wholesale price, high-speed railway outdoor cabinet, railway equipment cabinet IP55, railway cabinet supplier, outdoor communication cabinet price, railway signal cabinet quotation, KITOZER railway cabinet manufacturer, railway cabinet technical standards, railway cabinet protection rating

Scroll to Top