Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

Power Grid Harmonic Monitoring System

KITOZER Power Grid Harmonic Monitoring System Quotation List

ElectricNetworkHarmonicMonitoringSystem

2. Project Requirement Description

To assess the power quality status of the power grid, mitigate harmonic pollution, and ensure the safe and stable operation of both the power grid and electrical equipment, it is necessary to deploy a power grid harmonic monitoring system. The system shall provide continuous, high-precision online monitoring and analysis of power quality parameters including harmonic content, voltage deviation, frequency deviation, and three-phase unbalance. The system shall provide data support for power quality assessment, harmonic mitigation, and power grid operation and maintenance.

Key requirements include:

  • Continuous online monitoring of harmonic content and other power quality parameters
  • High-precision measurement meeting national standard Class A accuracy requirements
  • Real-time data acquisition and transmission from multiple monitoring points
  • Centralized data management and analysis through a unified monitoring platform
  • Statistical reporting and alarm management capabilities
  • Data support for harmonic mitigation and power grid maintenance decision-making

3. System Composition Introduction

The system consists of three main components:

1. Power Quality Monitoring Terminal

Deployed at each monitoring point, responsible for real-time acquisition of voltage and current signals, and calculation and analysis of power quality parameters such as harmonics.

2. Data Transmission Network

Utilizes industrial Ethernet, fiber optic, 4G wireless, and other communication methods to upload monitoring data to the central monitoring platform.

3. Power Quality Monitoring and Analysis Platform

Provides centralized management of multi-point monitoring data, harmonic analysis, statistical reporting, alarm management, and other functions.

4. Core Product Specifications & Parameters

4.1 Power Quality Monitoring Terminal

Parameter Specification
Voltage Measurement Range 0~480V
Current Measurement Range 0~5A (expandable)
Harmonic Measurement Range 2~63 harmonics, supports inter-harmonic measurement
Measurement Accuracy Voltage/Current: Class 0.2; Harmonic accuracy meets Class A requirements of GB/T 14549
Electrical Parameter Measurement Three-phase voltage, current, active/reactive power, power factor, frequency, phase angle
Transient Event Recording Voltage swell, sag, interruption, flicker, and other transient power quality events
Local Storage ≥1 year of minute-level monitoring data
Operating Temperature -20℃~+60℃
Installation Method DIN rail mounting
Communication RS485, Ethernet

4.2 Monitoring and Analysis Platform

Parameter Specification
Terminal Capacity Supports access of ≥100 monitoring terminals
Data Processing Synchronous data acquisition and analysis
Visualization Harmonic bar charts, spectrum diagrams, trend curves
Alarm Functions Power quality index limit-crossing alarms, traceable alarm events
Reporting Automatic generation of statistical analysis reports compliant with national standards
Data Export Multi-dimensional data query, comparative analysis, Excel/PDF format report export

5. Core Functions & Features of Products

Key Functions

  • Harmonic Online Monitoring: Continuous monitoring of 2~63 harmonic voltage/current content ratios and total harmonic distortion (THD), supporting inter-harmonic monitoring
  • Comprehensive Power Quality Monitoring: Simultaneous monitoring of voltage deviation, frequency deviation, three-phase unbalance, power factor, voltage flicker, and other power quality indicators
  • Transient Event Recording: Accurately records transient power quality events such as voltage sags, swells, short interruptions, and impact loads, including event time, magnitude, and duration
  • Intelligent Alarm Management: Automatic alarms when power quality indicators exceed limits, with hierarchical alarm management and multi-channel notification to operation and maintenance personnel
  • Statistical Analysis: Daily, monthly, and yearly statistics of power quality indicators, generation of statistical reports and analysis documents, with data export capability
  • Multi-Site Management: Unified access and centralized management of multiple monitoring points, with GIS map display of point distribution
  • Data Traceability Analysis: Historical data retrieval and source tracing analysis for harmonic exceedance events to locate harmonic sources

Product Features

  • High Measurement Accuracy: High-precision AD sampling with professional power quality algorithms, achieving national standard Class A accuracy for reliable data
  • Comprehensive Function Coverage: Integrates steady-state and transient power quality monitoring, covering all power quality indicators of the power grid
  • Large Data Storage Capacity: Large local storage at the terminal and long-term historical data storage on the platform, meeting power quality analysis data requirements
  • Easy Installation and Deployment: DIN rail terminal design with simple wiring, supporting rapid deployment for both new construction and renovation projects
  • Standard Compliance: Fully compliant with GB/T 14549, GB/T 15543, GB/T 12326, and other national power quality standards

6. Core Advantages of The Solution

  • Professional-Grade Monitoring Capability: Professional power quality monitoring hardware and analysis platform, meeting the high-precision monitoring requirements of the power industry and industrial users
  • Harmonic Mitigation Support: Precise localization of harmonic sources and assessment of harmonic pollution levels, providing data support for harmonic mitigation solution design and effectiveness verification
  • Strong System Compatibility: Supports multiple communication protocols, interfacing with distribution automation systems and energy management systems for data sharing
  • Excellent Cost-Effectiveness: Comprehensive functionality, stable performance, significant price advantage over comparable imported products, and low maintenance costs
  • Localized Service: Professional technical support and after-sales service, assisting users with power quality assessment and mitigation solution development

7. Manufacturer Strength Introduction

KITOZER (Guangzhou Lai’an Intelligent System Development Co., Ltd.)

  • Founded in 2002, with over 20 years of industry experience
  • ISO 9001, ISO 14001, ISO 45001 certified company
  • Recognized as a national high-tech enterprise
  • Production base located in Panyu District, Guangzhou, featuring standardized sheet metal fabrication workshops, electronic assembly workshops, and system commissioning workshops
  • Complete R&D, production, testing, and service system
  • All products undergo rigorous metrological calibration and performance testing to ensure measurement accuracy meets standards
  • Supports customized development, OEM/ODM manufacturing, and confidential project cooperation
  • Extensive stock inventory for rapid delivery
  • Professional power quality R&D team providing specialized monitoring and mitigation solutions for industrial enterprises, power grids, data centers, and other scenarios

8. Detailed Quotation Table

No. Product Name Model & Spec Technical Parameter Qty Unit Unit Price (USD) Total Price (USD) Brand Remark
1 Power Quality Online Monitoring Terminal KTZ-PQ-A1 2~63 harmonics, Class A accuracy, full power quality parameters, DIN rail mount 3 Unit 1332.00 3996.00 KITOZER Data acquisition at each monitoring point
2 Current Transformer KTZ-CT-100 100/5A, Class 0.2, busbar type 9 Unit 66.60 599.40 KITOZER Current signal acquisition
3 Industrial Switch KTZ-SW-05 5-port gigabit industrial switch, DIN rail mount 1 Unit 266.40 266.40 KITOZER On-site networking
4 4G Communication Gateway KTZ-GW-4G03 Industrial grade, full network compatible, encrypted data transmission 1 Unit 310.80 310.80 KITOZER Data upload
5 Monitoring Workstation Host KTZ-PC-W1 Commercial desktop host, 23.8″ monitor, keyboard & mouse 1 Set 1332.00 1332.00 KITOZER Local monitoring operation
6 Power Quality Monitoring & Analysis Platform KTZ-PQ-V1.0 Harmonic analysis, transient events, reports, alarms, multi-site management 1 Set 6660.00 6660.00 KITOZER Platform software license
7 Installation Accessory Kit KTZ-FC-PQ Includes signal cables, power cables, terminals, cable trays, etc. 1 Set 444.00 444.00 KITOZER Installation accessories
8 System Commissioning Service KTZ-TS-05 Equipment wiring guidance, calibration, platform commissioning, training 1 Item 1332.00 1332.00 KITOZER Professional technical service

Total Quotation Price: USD 14940.60

9. Quotation Terms & Conditions

  • Currency: All prices are quoted in US Dollars (USD)
  • Price Basis: EXW Guangzhou, China (or as negotiated)
  • Tax: Quoted prices are exclusive of tax and transportation costs. VAT special invoices require an additional 10% tax point; general invoices require an additional 3% tax point
  • Shipping: Delivery via logistics; freight is collected on delivery (payment made directly to the logistics company by the recipient)
  • Payment Terms: 30% deposit, 70% balance before shipment (negotiable)
  • Lead Time: 15-30 working days depending on configuration
  • Quotation Validity: This quotation is valid for 30 days from the date of issue
  • Packing & Shipping Costs: Quoted separately upon request

10. After-sales Service Description

  • Warranty: 3-year warranty on all products; free repair or replacement for non-artificial damage during the warranty period
  • Technical Support: Lifetime technical support provided
  • Spare Parts: Long-term availability of spare parts for all products
  • Remote Assistance: Remote troubleshooting support available
  • On-Site Service: On-site commissioning, maintenance, and training services available upon request
  • Professional Services: Wiring guidance, equipment calibration, platform commissioning, and operator training included

11. Contact & Order Information

  • To place an order, please visit the official KITOZER website: gdlain.com
  • Alternatively, contact the KITOZER sales team directly for order inquiries and quotations
  • All inquiries receive a response within 24 hours
  • Manufacturer: Guangzhou Lai’an Intelligent System Development Co., Ltd. / Guangdong Lai’an Smart Equipment Co., Ltd.
  • Brand: KITOZER
  • Production Base: Panyu District, Guangzhou, China
  • Customized solutions and project-specific configurations are available upon request

12. SEO Keywords & Tags

KITOZER quotation, power grid harmonic monitoring system, harmonic monitoring system price, power quality monitoring system quotation, harmonic online monitoring device, distribution system harmonic monitoring, power quality harmonic online monitoring system, grid harmonic monitoring equipment factory, harmonic monitoring system cost, power quality analyzer, KITOZER harmonic monitoring system, power quality monitoring terminal price, harmonic detection instrument, power quality monitoring solution quotation, wholesale harmonic monitoring system