Table of Contents
ToggleProduct Overview
The KITOZER 1U 8-outlet basic rack mount PDU is a rugged, unswitched power strip designed for dependable rack power distribution where metering is not required. It converts a single IEC C14 input into eight IEC C13 outputs, housed in a 1U steel chassis with rack ears. The unit uses a continuous copper busbar rather than daisy-chained wires, so current flows through a low-impedance path and heat is evenly distributed. A lighted master switch and integrated circuit breaker provide local control and fault protection. This entry-level PDU is ideal for general server racks, network cabinets, and workshop equipment where reliability matters more than remote monitoring.
Technical Specifications
Input: IEC C14 plug, 200 to 240VAC, 50 or 60Hz, rated 10A or 16A depending on model. Output: eight IEC C13 outlets, total 10A or 16A. Conductor: 1.5mm squared copper busbar. Input cord: 2 meter IEC C13 to C14 or C20 cord depending on model. Protection: rear-facing 16A miniature circuit breaker, illuminated power switch. Mechanical: 1U 19-inch rack mount, black steel chassis, dimensions 482 x 44 x 220 mm, weight 1.8 kg. Mounting: adjustable rack ears for 19-inch or 23-inch racks. Safety: CE, RoHS, cURus option. Brand: KITOZER. Warranty: 3 years.
Application Scenarios
Basic rack PDUs are the backbone of millions of server and network cabinets worldwide. This model suits small office server racks, branch network closets, security DVR cabinets, retail point-of-sale racks, audio and video equipment racks, and industrial control panels. It is also commonly used as a secondary or maintenance PDU inside a larger cabinet, providing convenient local power for laptops, test gear, and temporary equipment during servicing. The simple, tool-free operation means any staff member can use it without training.
Advantages and Benefits
The all-copper busbar design carries more current with less heat than wire-based strips, extending service life and reducing fire risk. The integrated circuit breaker trips only on overload, avoiding nuisance trips from inrush. A lighted switch gives clear on or off status at a glance. The compact 1U height preserves rack space. Adjustable rack ears fit both EIA 19-inch and wider equipment racks. At a fraction of the cost of metered PDUs, the basic strip delivers 100 percent of the power distribution function for racks that already have upstream branch monitoring.
Installation and Maintenance Recommendations
Mount the strip near the bottom of the rack to keep outlet cords out of airflow paths. Use cable ties or velcro to secure cords and reduce strain on the outlet connections. Do not exceed the rated total current; add the nameplate current of connected devices and keep the sum below 80 percent of the PDU rating for safety. Periodically inspect the input plug and outlet connections for warmth using a thermal camera during preventive maintenance. Vacuum dust from the ventilation slots annually. The unit requires no firmware updates and no configuration, making it a zero-maintenance part of the rack.
Every unit leaves the factory after a 100 percent function test, including a full load test at rated current, insulation resistance check, and communication port verification. Each chassis is visually inspected for finish quality and label legibility. A serial number plate records the production date, test result, and calibration reference, so the unit can be traced throughout its service life. KITOZER maintains a factory stock of common units and fittings for short lead-time orders, and larger projects are scheduled against a confirmed production plan. Standard export packing uses a double-wall carton with foam corners, and pallet packing is available for sea freight. The product is designed for disassembly and recycling at end of life, with clearly marked material types on the chassis.
Technical support is available by email and during business hours in the China time zone, with response within one working day. Installation guides, datasheets, CAD drawings, and declaration of conformity are provided on request for every order. KITOZER can also supply customized variants, including different outlet layouts, longer input cords, special colors, or OEM branding, subject to a minimum order quantity. The product family is designed to be compatible with accessories and mounting hardware from the same KITOZER range, so a single supplier can deliver the complete cable management or power distribution system for a project. After installation, KITOZER recommends keeping a small stock of spare parts on site, such as connectors, fuses, and mounting brackets, so routine repairs do not require long lead times.
KITOZER treats every order as a partnership rather than a single transaction. The sales engineering team works with the customer during design to confirm ratings, mounting options, and routing, so the delivered product matches the site conditions. During production, regular photo updates keep the buyer informed, and the finished goods are packed and labeled according to the project shipping mark. Documentation included with each shipment contains the packing list, test report, and certificate of conformity. For export orders, KITOZER handles export packing, container loading, and coordination with the forwarder, and can provide the required commercial invoice and packing list for customs clearance. After delivery, the local distributor or the factory itself provides commissioning guidance by video call, and remains available for technical questions during the first year of operation. This end-to-end support is why customers return to KITOZER for repeat projects across different sites and regions.
Price
From $45 per piece. Contact KITOZER for 10A and 16A variants and regional plug types.