KITOZER Rackmount UPS 10kVA 6U Data Center Online

Product Overview

The KITOZER Rackmount UPS 10kVA is a 6U high-density online UPS delivering 10kW at power factor 1.0 for enterprise server racks, small data centers, and edge computing hubs. Transformer-less high-frequency topology keeps the unit compact while achieving up to 96 percent online efficiency, lowering cooling load and operating cost. The rack-tower convertible design and front-access batteries make this model suitable for both cabinet and floor-standing deployments. With native parallel N+X capability up to 8 units, the platform grows with IT load without replacing the original UPS investment.

Built for mission-critical IT, the KITOZER 10kVA features three-phase input with single-phase output, simplifying integration in modern sites with three-phase power distribution. The unit includes an internal maintenance bypass, smart battery management, and a 7-inch color touchscreen HMI for comprehensive monitoring. Native SNMPv3 and Modbus TCP integration fits DCIM and building management platforms without add-on cards.

The KITOZER 10kVA is CE certified and complies with IEC 62040 safety and EMC standards. The high input power factor greater than 0.99 and low THDi less than 3 percent help the site comply with IEEE 519. The unit is designed for 24/7 operation in data center environments where downtime is unacceptable. Intelligent battery management monitors cell voltage, temperature, and charge current, maximizing battery service life.

Technical Specifications

Input 380 or 400V three phase, range 208 to 478VAC, input PF greater than 0.99, THDi less than 3 percent. Output 200, 208, 220, 230, or 240VAC single phase selectable, power factor 1.0, online efficiency 96 percent, eco efficiency 98 percent. Hardwired output terminal. Inverter overload 110 percent 10 min, 125 percent 5 min. Internal battery provides 8 to 12 minutes at half load; external battery cabinet supports long runtime.

Parallel up to 8 units N+X. Communications: Modbus TCP, SNMPv3, Web HMI, USB, RS232, dry contacts, optional dry-contact I/O. Touch LCD front panel. Dimensions 440 by 800 by 265 mm, weight 95 kg. Operating temperature 0 to 40 degrees Celsius. Noise level less than 60 dB(A). Event log stores 1024 records. Three-year standard warranty.

Application Scenarios

Typical uses include enterprise server rooms, colocation cages, edge data centers, financial branch IT, hospital core systems, manufacturing execution systems, and cloud point-of-presence racks. The three-phase input with single-phase output simplifies integration in modern sites with three-phase power distribution. The parallel option supports N+1 redundancy for business-critical workloads.

External battery cabinets are chosen where generator start-up exceeds 15 seconds or where orderly shutdown of virtualization clusters is required. Additional deployments include government data centers, media rendering farms, and university supercomputing clusters. The 6U compact size maximizes usable rack space in high-density cabinets. The unit is also suitable for retail backbone networks, bank branch servers, and large corporate office IT rooms.

Key Advantages

Power factor 1.0 means full 10kW real output, maximizing use of the 10kVA frame. 96 percent online efficiency cuts annual energy cost and reduces cooling tonnage. Three-phase input balances load on facility feed. Native parallel up to 8 units enables pay-as-you-grow architecture.

Hot-swap batteries and internal bypass simplify service. Low THDi less than 3 percent protects upstream transformers and generators. Comprehensive monitoring via SNMPv3 and Modbus TCP fits DCIM platforms. 7-inch color touchscreen provides intuitive operation. Three-year standard warranty with optional extended coverage. CE certified for global deployment.

Installation and Maintenance Advice

Use heavy-duty sliding rails rated for 95 kg. Provide three-phase 32A input breaker with neutral and ground. Maintain 1U clearance above and below. Connect external battery cabinets with fused DC cables.

For parallel systems, equalize battery state of charge and use dedicated parallel cables. Schedule battery impedance test every 6 months. Replace batteries at 4 to 5 years. Keep ambient at 20 to 25 degrees Celsius and relative humidity below 95 percent non-condensing. Perform annual preventive maintenance by qualified electrician. Store firmware recovery file locally. Keep spare fans and contactors on site.

Price

From $5,600 per unit. External battery cabinet, parallel kit, and extended warranty quoted separately.