Table of Contents
ToggleProduct Overview
The KITOZER RF feeder cable 1/2 inch corrugated is the standard transmission line connecting base station radios, antennas, DAS master units, and repeaters. The corrugated copper outer conductor provides excellent shielding and power handling, while the foamed polyethylene dielectric keeps attenuation low. A black UV-stabilized polyethylene jacket protects the cable from sunlight, moisture, and ozone. At 1/2 inch diameter, the cable is flexible enough to bend around corners and pull through cable trays, yet rigid enough to span between rooftop towers without sagging.
The cable is available with pre-assembled N male, 4.3-10 male, or 7/16 DIN male connectors on one or both ends, tested to a VSWR under 1.15. Plenum-rated LSZH versions are available for installation in air-handling spaces. Standard reels are 500 meters, and custom cut lengths with factory-assembled connectors are available to reduce on-site termination errors.
Technical Specifications
Diameter: 13 mm, 1/2 inch. Impedance: 50 ohm. Attenuation at 1 GHz: 0.095 dB per meter. At 2 GHz: 0.14 dB/m. At 3.5 GHz: 0.19 dB/m. Velocity factor: 0.88. Capacitance: 76 pF per meter. Max power at 1 GHz: 750 W. Shielding: greater than 100 dB. Jacket: black PE or LSZH. Bend radius: 70 mm installed, 150 mm installation. Tensile: 600 N. Operating temperature: minus 40 to plus 70 C. Weight: 0.11 kg per meter. Reel: 500 m. KITOZER, 5 year warranty.
Applications
1/2 inch feeder is the workhorse cable for rooftop macro cell installations, DAS risers, and repeater links. It connects RRU antennas on tower tops to baseband units in equipment shelters. In-building DAS uses 1/2 inch cable from floor risers to ceiling antennas. Repeaters and small cells use pre-terminated 1/2 inch jumpers between the radio unit and donor antenna. The cable is also used for Wi-Fi 6E outdoor bridge links.
Key Advantages
Corrugated outer conductor keeps VSWR low even after repeated bending. Low foamed dielectric reduces attenuation by 15 percent compared with solid PE cables. UV jacket withstands 10 years of rooftop exposure. Pre-assembled connectors eliminate field termination errors, which are the leading cause of VSWR and PIM failures. High shielding prevents the cable from radiating interfering energy into adjacent systems.
Installation and Maintenance
Use cable grips and pulleys when pulling through long runs to keep tension below 600 N. Support the cable with hangers every 1 meter on vertical runs and every 1.5 meters horizontally. Maintain a 20 cm separation from AC power cables to avoid coupling. Ground the outer conductor at both ends using a grounding kit. Seal outdoor connectors with self-amalgamating tape. Test VSWR at installation with a cable analyzer and keep the baseline reading for future comparison. Re-test annually or after storm events.
Price
From $5.5 per meter bare cable. Pre-terminated jumpers from $28. Contact +86 13922289957 for custom lengths, plenum rating, and 7/8 inch or 1-5/8 inch sizes.