KITOZER Smart PDU: 12-Port 32A Monitored For Medium Racks

Product Overview

The KITOZER 12-port 32A monitored smart PDU is a 1U horizontal rack power distribution unit engineered for medium-density server racks and networking cabinets. It accepts a 32A single-phase input and distributes power across twelve IEC C13 outlets, while continuously measuring per-phase voltage, current, power, energy, and frequency. A backlit OLED front panel gives local staff immediate read access, and the onboard Ethernet module enables remote monitoring through a web dashboard and standard management protocols. Built-in surge protection and input circuit breaker protect connected equipment from transients and overloads. The robust steel chassis and copper busbar are designed for continuous duty in commercial data center environments.

The surge protection module is rated for 10kA surge current and includes a status indicator that shows when the protection component is still within its service life. A built-in humidity sensor on the PDU alerts operators if condensation forms inside the cabinet, which is a common precursor to corrosion and short circuits. The web dashboard is mobile-friendly, so facilities staff can check rack power from a phone during walk-throughs.

Technical Specifications

Input: single phase 200 to 240VAC, 50 or 60Hz, rated 32A, hardwired or IEC inlet option. Output: twelve IEC C13 outlets, total 32A. Metering: voltage plus or minus 1 percent, current plus or minus 1 percent, active energy plus or minus 2 percent. Communication: 10 or 100Mbps Ethernet, Modbus TCP, SNMP v1, v2c, v3, HTTP, HTTPS, Telnet, SSH. Sensors: built-in temperature port supporting optional temperature and humidity probe. Alarms: over-voltage, under-voltage, over-current, overload, high temperature, via email, SNMP trap, and relay contact. Mechanical: 1U 19-inch rack mount, steel chassis, dimensions 482 x 44 x 320 mm, weight 3.2 kg. Operating temperature: 0 to 45 degrees Celsius. Safety: CE, RoHS, IEC 60950. Brand: KITOZER. Warranty: 3 years.

Input cable for hardwired version is field-terminated on site. The unit supports up to 32 user accounts with role-based read and write permissions. Event log stores the last 500 events with timestamps. Energy resettable and non-resettable totals are both recorded. The relay alarm output is rated 30V DC 1A and can drive a remote beacon or BMS input. A Kensington lock slot on the rear secures the Ethernet cable against accidental disconnection.

Application Scenarios

This 32A PDU is typically installed in enterprise server racks hosting three to six rack servers, storage arrays, and core network switches. It suits co-location cages, university data center racks, government network equipment cabinets, and industrial control rooms. The external sensor port allows deployment in hot-aisle or cold-aisle configurations where ambient temperature monitoring is required alongside power measurement. Co-location operators use the metering data to bill tenants by actual rack energy draw, while in-house data centers use it to balance load across redundant power paths and identify rack-level hotspots before they trigger thermal shutdowns.

The unit is also a common choice for broadcast equipment racks, where cameras, routers, and monitors must stay powered through long live events. In video production, the PDU provides a permanent record of energy use that can be compared between shows. Research laboratories use it to track the power draw of scientific instruments, which is required for grant reporting. The surge protection gives extra confidence for sensitive measurement gear that can be damaged by lightning-induced transients on the building supply.

Advantages and Benefits

The 32A rating delivers sufficient headroom for denser racks without requiring a 3U power strip. Per-input energy measurement enables accurate charge-back and capacity planning. Surge protection extends the service life of connected IT equipment during lightning storms or grid switching events. The dual network protocol support means the PDU integrates into legacy SNMP-based DCIM platforms as easily as modern Modbus TCP building management systems. Optional temperature and humidity probes turn the PDU into a combined power and environment monitoring point, reducing the number of separate sensors needed in the cabinet.

The OLED display is readable in both bright data center aisles and dim back rooms, and it rotates automatically based on mounting orientation. The 1U height leaves room for cable managers above and below. The copper busbar runs the full length of the chassis, eliminating the wire splices that cause hot spots in cheaper strips. Because the PDU is network-addressable, it can be discovered by standard network scanning tools, which simplifies asset inventory. The unit is also available with a C20 inlet for flexible plug-and-play installation in rented co-location space.

Installation and Maintenance Recommendations

Mount the PDU in the bottom or middle of the rack for best cable management clearance. Use a 6mm square copper input cable sized for 32A continuous load and torque the terminal screws to the manufacturer specification. Connect the Earth conductor first and verify continuity before energizing. During commissioning, configure the IP address, subnet mask, gateway, and NTP, then link the PDU serial number to the rack asset in the DCIM database. Test alarm notifications by deliberately setting a low over-current threshold and verifying the email and SNMP trap are received. Inspect input terminals annually and recalibrate current sensing against a reference meter every two years.

When connecting servers, leave 1U of spare outlets for future expansion and label every cord at both ends. Use rack cable management arms to support the weight of power cords, so no strain transfers to the PDU outlets. If the optional temperature probe is fitted, place it at the front center of the rack at mid-height, away from direct airflow from the air conditioner. Periodically export the energy log and archive it in the central energy database. The surge protection indicator should be checked quarterly; if it goes red, replace the PDU or the surge module during the next maintenance window.

Price

From $265 per piece. Contact KITOZER for bulk orders and customized outlet layout.