KITOZER
KITOZER

KITOZER STS: 16A Static Transfer Switch Single Phase For Edge IT

Product Overview

The KITOZER 16A static transfer switch is a compact, semiconductor-based dual-source power continuity device designed for single-phase edge computing nodes, network closets, small telecom cabins, and light medical equipment. Unlike electromechanical automatic transfer switches that rely on contactors and relays, the KITOZER STS uses inverse-parallel silicon controlled rectifiers to commutate current between two independent live sources without any moving contacts. The transfer action is completed in less than four milliseconds, which is well below the hold-up time of almost all switched-mode power supplies used in servers, routers, and storage gear. This means the connected load never experiences a measurable break, even when the preferred source collapses abruptly. The unit is built into a slim wall-mount or 19-inch rack-ready enclosure, with front panel LEDs showing source A healthy, source B healthy, load energized, bypass active, and fault state. A manual maintenance bypass rotary switch is integrated so technicians can service the STS electronics without de-energizing the downstream load, a feature that dramatically reduces planned outage windows for remote edge sites that are rarely staffed.

Technical Specifications

Electrical rating: 16A continuous, single phase 230VAC plus minus 15 percent, 50 or 60Hz auto sensing. Transfer topology: break-before-make SCR static switching, typical transfer time under 4ms, maximum transfer under 8ms with fully inductive load. Source monitoring: under voltage, over voltage, under frequency, over frequency, and phase loss detection on both feeds. Programmable voltage window from 180V to 260V and frequency window from 47Hz to 63Hz. Cooling: natural convection, no fan, zero audible noise. Communication: RS485 Modbus RTU standard, optional Ethernet Modbus TCP, optional dry contact alarm outputs for source fail, transfer event, and internal fault. Display: front LED bar plus optional OLED showing source voltage, load current, transfer count, and event log. Protection: SCR over temperature, load over current short circuit, and input reverse phase. Enclosure: steel wall mount or 1U rack, IP20, operating temperature 0 to 55 degrees C. Standards: CE, IEC 60947, 5 year warranty.

Application Scenarios

The 16A STS is the right size for distributed edge locations where a small but critical load must never blink. Typical deployments include street cabinet telecom and 5G base station shelters, small retail point-of-sale and payment terminal systems, outpatient clinic imaging and diagnostic devices, laboratory analytical instruments, and small security or access control controllers. It is also frequently installed ahead of a single small UPS in a dual-cable architecture, where two utility feeds enter the building but only one UPS is present. In this configuration the STS sits between the two incomers and the UPS input, ensuring that even if one utility feed fails the UPS continues to see stable power and its batteries remain fully charged. For IoT gateways, edge servers, and industrial human-machine terminals that carry real-time control traffic, the sub-4ms transfer avoids dropped sessions and prevents unexpected process stops that a mechanical contactor transfer would cause.

Key Advantages

The first advantage is zero wear. SCRs have no contacts to arc, erode, or weld, so the unit can survive hundreds of thousands of transfers over its design life without maintenance intervals tied to contactor replacement. The second advantage is speed. Four milliseconds is fast enough that virtually all IT and electronic loads ride through the event without triggering their own under-voltage shutdown logic. The third advantage is remote visibility. Modbus reporting of source voltage, load current, transfer count, and alarm state lets the central network operations center see source quality trends before a failure happens, rather than reacting after an edge site goes dark. The fourth advantage is the integrated maintenance bypass, which turns a repair visit into a live work procedure and avoids scheduling a maintenance window just to swap a control board. Finally, the fanless natural-convection design means no filter to clean, no fan to fail, and zero acoustic emission, which matters in offices, waiting rooms, and residential-adjacent cabinets.

Installation and Maintenance Recommendations

Mount the unit in a dry, ventilated cabinet with at least 50mm clearance above and below for convection. Connect source A and source B to their labelled terminals with correctly rated copper, verify phase and neutral polarity on both feeds before energizing, and confirm that the two sources are derived from independent transformers or independent utility incomers. Set the voltage and frequency windows to match the expected supply quality rather than leaving factory defaults, because overly wide windows can mask a failing source while overly narrow windows cause nuisance transfers. During commissioning, perform a forced transfer test by opening source A with the load energized and verify the load stays up and the event is logged. Maintenance is simple: inspect terminals annually for torque, clean the enclosure, read the event log, and exercise the manual bypass selector once per year to keep the mechanism free moving. Keep spare SCR trigger boards and fuses on hand for remote sites, and use the RS485 or Ethernet port to trend source voltage so that gradual source degradation is visible months before it becomes an outage.

Ordering Information

The 16A STS is available in wall mount and 1U rack mount variants, with source A preferred, source B preferred, or automatic re-transfer logic selectable at the factory. The standard unit ships with RS485 Modbus RTU, and the Ethernet Modbus TCP option adds remote Web HMI and SNMP traps for integration into larger monitoring platforms. Optional accessories include a remote emergency stop panel, a source mimic panel for the front of the cabinet, and a set of current transformers for load metering. Lead time is typically two to three weeks for standard configurations and four to six weeks for custom panel integration. KITOZER provides factory commissioning support, a full-load test report before shipment, and a spare parts kit for remote edge deployments. The unit is CE marked and backed by a five year warranty, with extended warranty available on request.

Price

From $1,180 per piece. Contact the factory for current lead time, optional Modbus TCP gateway, and custom panel integration. Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com