The KITOZER 3000A static transfer switch is the high-capacity member of the STS family, engineered for the main switchboard of very large data centers, hyperscale campuses, and heavy industrial plants where two utility services must be merged onto a single critical bus without any source interruption. The unit uses water- or forced-air-cooled SCR stacks per phase, a triple-redundant controller architecture, and a full-size maintenance bypass breaker rated for the full 3000A. Transfer time is held under 8ms even at rated current, which means the downstream UPS fleet and critical distribution never experience a source break. The controller applies programmable voltage windows, frequency windows, phase angle synchronization, and transfer inhibit logic, and it logs every event with a time stamp, a waveform capture, and a snapshot of all power quality parameters. The cabinet is built as a heavy-duty floor-standing switchgear with busbar top or bottom entry, front and rear access, and a touchscreen HMI plus a remote HMI on Ethernet.
Technical Specifications
Rating: 3000A continuous at 400V three phase plus neutral, 50 or 60Hz; 380V or 480V variants on request. Transfer: SCR static per pole, break-before-make, typical 4ms, maximum 8ms; synchronized transfer mode standard for this rating. Source monitoring: three phase RMS voltage, current, frequency, unbalance, phase rotation, THD, power factor, active and reactive power, energy on both feeds. Cooling: redundant forced air or optional water-to-air heat exchanger. Controller: triple redundant, automatic switchover between CPUs. HMI: 10 inch color touchscreen, local and remote, event log with time stamping, waveform capture, trend graphs. Communication: dual Ethernet Modbus TCP, SNMP v3, BACnet IP, Web HMI, email traps, dry contact IO. Protection: semiconductor fuses per pole, SCR over temperature, over current, earth leakage, source reverse phase. Cabinet: floor standing IP31 or IP32, busbar top or bottom, operating 0 to 40 degrees C. Standards: CE, IEC 60947, optional UL, 5 year warranty.
Application Scenarios
The 3000A STS is installed at the point where two utility services enter a hyperscale data center campus and are combined onto a single critical bus feeding multiple UPS systems. It is also used in large industrial parks, integrated steel mills, aluminum smelters, and large chemical plants where process continuity is valued in millions of dollars per hour. In large hospital complexes and university teaching hospitals, it can feed the central emergency bus. For offshore platforms and LNG terminals, it selects between shore power, main generators, and emergency generators with sub-cycle speed. In large transit hubs and airports, it protects baggage handling, air traffic control, and life safety busbars. In solar and wind generation substations, it can switch auxiliary supplies between station service transformers without dropping control and protection systems.
Key Advantages
The primary advantage is uninterrupted source selection at very high current. A mechanical 3000A automatic transfer switch takes 100ms or more, which discharges UPS batteries, trips motor contactors, and interrupts process control. The KITOZER STS holds under 8ms. Triple-redundant control means no single CPU fault can cause a transfer or a shutdown. The water cooling option allows very high ambient density in switchrooms with limited air conditioning headroom. Waveform capture and time-stamped event logging give forensic evidence for root cause analysis and tier compliance reporting. The maintenance bypass is fully rated, so routine servicing of SCR blocks is performed live. Open protocols integrate directly with SCADA, DCIM, and BMS platforms. Factory full-load testing with a supplied report de-risks site commissioning.
Installation and Maintenance Recommendations
This rating requires a properly designed switchroom with floor loading rated for the cabinet weight, cable trench sized for 3000A busbar stubs, and dedicated air conditioning or water cooling. On commissioning, verify busbar torque with calibrated tools, calibrate voltage and frequency windows, set preferred source and re-transfer timing, and force a transfer on each source under real load. Coordinate protection with upstream utility breakers and downstream UPS input breakers using the factory protection study. Maintenance program: thermal imaging of busbar joints quarterly, torque verification annually, cooling filter or water-side service per schedule, event log review monthly, and bypass exercise annually. Keep spare gate boards, fuses, and a cooling fan module on site, and sign a service contract for remote diagnostics. Because a 3000A asset is part of the campus power architecture, any change to source configuration or protection setting must be logged and reviewed by the site power engineer before being applied.
Ordering Information
The 3000A STS is built to order as a heavy-duty switchgear assembly, with busbar top or bottom entry, IP31 or IP32 enclosure, and forced air or water-to-air cooling options. The triple-redundant controller is standard, and the synchronized transfer mode is included for this rating because large motor and transformer loads on the bus cannot tolerate out-of-sync commutation. Optional packages include SNMP v3, BACnet IP, waveform capture export, redundant power supply for the control circuit, and a remote mimic panel in the site control room. KITOZER performs full-load factory acceptance testing at 3000A before shipment, and a test report, dimension drawing, and protection study support are supplied. Lead time is twelve to sixteen weeks, and site commissioning by factory engineers is available on request.
Price
From $96,000 per piece. Contact the factory for full-load test report, water cooling option, and custom switchgear layout. Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com