Table of Contents
ToggleProduct Overview
The KITOZER Tower UPS 20kVA is a medium-capacity online double-conversion system delivering 18kW at power factor 0.9 for enterprise data centers, manufacturing plants, and large commercial facilities. Three-phase input and output, combined with native parallel up to 8 units, allows operators to build N+1 or N+X redundancy without external controllers. The integrated maintenance bypass, smart battery management, and 7-inch touchscreen make daily operation intuitive, while the high-frequency transformer-less design keeps efficiency above 95 percent.
Built for 24/7 critical power, the KITOZER 20kVA uses IGBT inverter technology with DSP control for precise output regulation. The wide input range from 304 to 478VAC rides through deep sags without battery switching. Input power factor correction greater than 0.99 and THDi less than 3 percent ensure compliance with IEEE 519 and protect upstream infrastructure. The unit is CE certified and complies with IEC 62040 standards.
The 7-inch color touchscreen provides real-time metering, event log, and waveform capture for troubleshooting. The internal maintenance bypass allows service without load interruption. Intelligent battery management monitors cell voltage, temperature, and charge current, performing periodic self-tests and predicting end-of-life. Native Modbus TCP and SNMPv3 integration fits DCIM and BMS platforms without add-on cards.
Technical Specifications
Input 380, 400, or 415V three phase, range 304 to 478VAC, input PF greater than 0.99, THDi less than 3 percent. Output 380, 400, or 415V three phase, PF 0.9, online efficiency 95.5 percent. Overload 110 percent 60 min, 125 percent 10 min, 150 percent 1 min. Internal battery gives 10 to 20 minutes at half load; external battery cabinet supports long runtime.
Parallel up to 8 units. Maintenance bypass standard. Modbus TCP, SNMPv3, Web HMI, USB, RS232, dry contacts. Dimensions 600 by 900 by 1800 mm, weight 380 kg. IP20 cabinet. Operating temperature 0 to 40 degrees Celsius. Noise level less than 65 dB(A). Event log stores 1024 records. Three-year standard warranty.
Application Scenarios
Common deployments include mid-size data centers, core banking systems, hospital IT, semiconductor manufacturing lines, food processing plants, and large retail distribution centers. The parallel architecture is chosen when uptime SLAs require redundant power. External battery cabinets support 30 minutes to 4 hours of autonomy for orderly shutdown or generator ride-through.
Additional use cases include pharmaceutical plants, water treatment facilities, transportation hubs, and university data centers. The N+X configuration provides redundancy without external STS. The unit is also suitable for government back-office systems, media production servers, and large corporate office IT rooms. The wide input window allows deployment in regions with unstable grid voltage.
Key Advantages
Parallel up to 8 units without external controller reduces cost and complexity. 95.5 percent efficiency lowers utility bill. Low input THDi protects utility network. Smart battery management predicts end-of-life and balances string charge. Maintenance bypass enables service without downtime.
Comprehensive communication protocols fit DCIM and BMS platforms. Robust overload rating supports motor and inrush loads. Wide input window rides through sags and swells. Color touchscreen and event log reduce troubleshooting time. CE certified for global deployment. Three-year standard warranty.
Installation and Maintenance Advice
Install on vibration-isolated concrete floor. Provide separate input and output breaker with coordination. Observe phase rotation. For parallel systems, use dedicated parallel cables and identical firmware. Size external battery cables for maximum fault current.
Test batteries every 6 months. Keep ambient 20 to 25 degrees Celsius. Annual maintenance includes fan, capacitor, and filter inspection. Label bypass positions clearly. Keep spare fans and contactors on site. Update firmware in maintenance window.
Price
From $9,800 per unit. Battery cabinet and parallel options quoted separately. Contact KITOZER factory for bulk pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com