Table of Contents
ToggleProduct Overview
The KITOZER Tower UPS 30kVA is a high-capacity online system delivering 30kW at power factor 1.0 for small data centers, enterprise IT rooms, and industrial critical loads. Three-phase input and output, combined with transformer-less high-frequency topology, achieve up to 96 percent efficiency while keeping cabinet size compact. The unit supports parallel operation up to 8 units for N+X redundancy and includes an internal maintenance bypass, smart battery management, and a color touchscreen HMI for daily operation.
Built for mission-critical IT, the KITOZER 30kVA uses IGBT inverter technology with DSP control for precise output voltage and frequency regulation. The wide input range from 304 to 478VAC rides through deep sags without battery switching. Input power factor correction greater than 0.99 and THDi less than 3 percent ensure IEEE 519 compliance. The unit is CE certified and complies with IEC 62040 safety and EMC standards.
The 7-inch color touchscreen provides real-time metering, event log, and waveform capture. The internal maintenance bypass allows safe service without load interruption. Intelligent battery management monitors cell voltage, temperature, and charge current, performing periodic self-tests and predicting end-of-life. Native Modbus TCP and SNMPv3 integration fits DCIM and BMS platforms without add-on cards.
Technical Specifications
Input 380, 400, or 415V three phase, range 304 to 478VAC, input PF greater than 0.99, THDi less than 3 percent. Output 380, 400, or 415V three phase, PF 1.0, online efficiency 96 percent. Overload 110 percent 60 min, 125 percent 10 min, 150 percent 1 min. Internal battery 15 to 25 minutes half load; external battery cabinet extends runtime.
Parallel up to 8 units. Modbus TCP, SNMPv3, Web HMI, USB, dry contacts. Dimensions 800 by 1000 by 1900 mm, weight 520 kg. IP20 cabinet. Operating temperature 0 to 40 degrees Celsius. Noise level less than 65 dB(A). Event log stores 1024 records. Three-year standard warranty.
Application Scenarios
Deployments include small data centers, cloud edge nodes, hospital clinical systems, manufacturing execution systems, railway signaling, and large corporate offices. The N+X parallel option is used when uptime SLAs require redundant power. External battery cabinets provide 30 minutes to several hours of backup for sites without generators.
Additional applications include pharmaceutical plants, food processing lines, water treatment facilities, and transportation hubs. The unit is also suitable for government data centers, financial back offices, and university computer labs. The wide input window allows deployment in regions with unstable grid voltage. The parallel architecture supports pay-as-you-grow as IT load increases.
Key Advantages
PF 1.0 delivers full 30kW output from a 30kVA frame. 96 percent efficiency reduces energy cost. Low THDi protects upstream grid. Parallel up to 8 units enables modular growth. Maintenance bypass supports live service.
Smart battery management extends battery life. Comprehensive monitoring integrates with DCIM. Color touchscreen and event log reduce troubleshooting time. Robust overload rating supports motor and inrush loads. CE certified for global deployment. Three-year standard warranty.
Installation and Maintenance Advice
Install on reinforced concrete floor. Coordinate upstream breaker with UPS short-circuit rating. For parallel systems, use dedicated paralleling cables and identical firmware. Size battery cables for fault current.
Test batteries every 6 months. Keep ambient 20 to 25 degrees Celsius. Annual preventive maintenance by qualified technician. Label bypass and emergency stop positions. Keep spare fans and contactors on site. Update firmware in maintenance window.
Price
From $14,500 per unit. Battery cabinet and parallel kit quoted separately. Contact KITOZER factory for bulk pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com