KITOZER Vertical PDU: 0U 24-Outlet High Density

Product Overview

The KITOZER 0U vertical PDU mounts along the side of a rack instead of occupying rack units, freeing every U for servers and switches. Twenty-four IEC C13 outlets are arranged along the vertical body, accepting plugs from both sides of the rack. The unit accepts a 32A input and distributes power vertically, with optional metering and switching modules. A built-in strain relief and secure mounting brackets hold the PDU rigidly against the rack rail. This vertical form factor is the standard choice for dense server racks where horizontal 1U or 2U PDUs consume valuable U space.

Technical Specifications

Input: single phase 200 to 240VAC, 50 or 60Hz, rated 32A, hardwired or IEC C20 inlet. Output: twenty-four IEC C13 outlets, total 32A. Conductor: copper busbar rated 32A continuous. Options: monitored (voltage, current, energy) or switched (per-outlet relay) variants. Mechanical: vertical 0U mount, black steel chassis, dimensions 48 x 440 x 44 mm, weight 2.6 kg. Mounting: brackets fit 19-inch racks on left or right rail. Safety: CE, RoHS. Brand: KITOZER. Warranty: 3 years.

Application Scenarios

Vertical PDUs are the default choice in modern data center racks where every U is occupied by compute or storage. They are used in enterprise server racks, co-location cages, high-performance computing clusters, and dense network switch cabinets. The side-mount design keeps power cords out of the horizontal cable management channel, improving airflow and simplifying future adds. Network operations teams prefer vertical PDUs because outlet numbering follows the vertical layout of the rack, making it easy to trace which server is on which outlet.

Advantages and Benefits

By using zero rack units, the vertical PDU effectively adds 1U of usable server space compared with a horizontal PDU. Outlets facing both sides reduce cord congestion because servers on either side of the rack can plug in without crossing over. The copper busbar handles 32A continuously without hot spots. Monitored and switched options allow the same mechanical form factor to scale from basic to intelligent deployments. The rigid vertical mounting reduces the risk of plugs working loose from vibration. Because the PDU runs the full height of the rack, cord lengths from servers to outlets are short and neat.

Installation and Maintenance Recommendations

Choose left or right mounting based on where the rack power entry is located, and keep the PDU on the opposite side from the network cable manager for best separation. Use the included brackets at the top, middle, and bottom to prevent the long chassis from flexing. Route the input cable along the rack vertical rail and secure it every 300 mm. Label each outlet with its number and the connected device. For monitored variants, configure the IP and alarm contacts during commissioning. Inspect outlet snugness every six months, as server vibration can gradually loosen plugs. Keep a spare PDU on site for fast replacement if a fault occurs.

Every unit leaves the factory after a 100 percent function test, including a full load test at rated current, insulation resistance check, and communication port verification. Each chassis is visually inspected for finish quality and label legibility. A serial number plate records the production date, test result, and calibration reference, so the unit can be traced throughout its service life. KITOZER maintains a factory stock of common units and fittings for short lead-time orders, and larger projects are scheduled against a confirmed production plan. Standard export packing uses a double-wall carton with foam corners, and pallet packing is available for sea freight. The product is designed for disassembly and recycling at end of life, with clearly marked material types on the chassis.

Technical support is available by email and during business hours in the China time zone, with response within one working day. Installation guides, datasheets, CAD drawings, and declaration of conformity are provided on request for every order. KITOZER can also supply customized variants, including different outlet layouts, longer input cords, special colors, or OEM branding, subject to a minimum order quantity. The product family is designed to be compatible with accessories and mounting hardware from the same KITOZER range, so a single supplier can deliver the complete cable management or power distribution system for a project. After installation, KITOZER recommends keeping a small stock of spare parts on site, such as connectors, fuses, and mounting brackets, so routine repairs do not require long lead times.

KITOZER treats every order as a partnership rather than a single transaction. The sales engineering team works with the customer during design to confirm ratings, mounting options, and routing, so the delivered product matches the site conditions. During production, regular photo updates keep the buyer informed, and the finished goods are packed and labeled according to the project shipping mark. Documentation included with each shipment contains the packing list, test report, and certificate of conformity. For export orders, KITOZER handles export packing, container loading, and coordination with the forwarder, and can provide the required commercial invoice and packing list for customs clearance. After delivery, the local distributor or the factory itself provides commissioning guidance by video call, and remains available for technical questions during the first year of operation. This end-to-end support is why customers return to KITOZER for repeat projects across different sites and regions.

Price

From $155 per piece for the basic 24-outlet vertical PDU. Contact KITOZER for metered and switched versions.