KITOZER
KITOZER

KVM Switch Installation Manual

Table of Contents

Preface

In today’s rapidly evolving information and digitalization landscape, the need for centralized management of multiple computers, servers, and workstations in data centers, enterprise server rooms, industrial control sites, and office workstations has become increasingly prominent. The traditional management model of “one device paired with one set of keyboard, monitor, and mouse” not only occupies significant physical space and increases hardware procurement costs, but also forces operations and maintenance personnel to constantly move between devices, reducing management efficiency while increasing cabling complexity and failure risks in the server room.

As a core category of network management equipment, the KVM Switch has become standard hardware in server room operations, desktop offices, industrial control, and other fields, thanks to its core capability of “managing multiple hosts with one set of keyboard, mouse, and monitor.” Guangzhou Lain Intelligent System Development Co., Ltd. has been deeply engaged in the field of intelligent server room equipment for many years and has launched a full series of KVM Switch products, covering desktop, rack-mounted, LCD-integrated, digital IP, and matrix types, compatible with various video interfaces including VGA, HDMI, DVI, and DP, supporting 2 to 64 ports and cascade expansion, meeting full-scenario management needs from personal office to ultra-large data centers.

This manual is the general installation, wiring, and commissioning specification for the full series of KVM Switches manufactured by Guangzhou Lain Intelligent System Development Co., Ltd. It covers comprehensive product technical analysis, standardized installation procedures, detailed wiring guidelines, systematic commissioning steps, full-scenario troubleshooting, and acceptance standards, aiming to provide users with professional, comprehensive, and actionable operating guidance to ensure standardized installation, correct wiring, stable operation, and efficient maintenance. This manual applies to all analog KVM Switches, digital KVM Switches, IP KVM Switches, LCD KVM consoles, matrix KVM Switches, and other products under the company. Special parameters and operational differences for different models will be individually noted in the corresponding chapters.

Please read this manual carefully in its entirety before installing, commissioning, or using this product, and strictly follow the operating specifications to avoid equipment damage or functional abnormalities caused by improper operation. The content of this manual will be continuously updated based on product iterations. The final right of interpretation belongs to Guangzhou Lain Intelligent System Development Co., Ltd.

Chapter 1: Product Introduction

1.1 Product Definition

A KVM Switch, short for Keyboard, Video, and Mouse Switch, is a signal management device that is either pure hardware or a combination of hardware and software. Its core function is to enable one set of keyboard, monitor, and mouse to control multiple computers, servers, workstations, and other devices with video output, without physical cable plugging and unplugging. The management target can be quickly switched via buttons, hotkeys, OSD menus, network commands, etc., significantly improving multi-device management efficiency and reducing hardware costs and space occupation.

As an important branch of network management equipment, a KVM Switch is essentially a peripheral signal routing device. It switches and schedules keyboard input signals, mouse input signals, and monitor output video signals, establishing dedicated signal paths between different hosts. High-end KVM Switches can also integrate extended functions such as audio transmission, USB peripheral sharing, serial port control, virtual media, remote IP access, user permission management, and operation log auditing, upgrading from simple signal switching devices to centralized operations and maintenance management platforms.

1.2 Product Development History

The development of KVM technology has evolved in parallel with the proliferation of computers and servers, roughly divided into four stages:

First-Generation Analog KVM Stage (1990-2000): With the rise of server rooms, early KVM Switches primarily used PS/2 interfaces with VGA video, employing pure mechanical switching or simple electronic switching. They only supported local manual button switching, with port counts mostly ranging from 2-8. Functionality was limited with constrained compatibility, mainly addressing the fundamental issue of insufficient server room space.

Mature Analog KVM Stage (2000-2010): USB interfaces gradually replaced PS/2 interfaces, and video interfaces expanded from VGA to DVI. KVM Switches added hotkey switching, OSD on-screen menus, auto-scanning, buzzer alerts, cascade expansion, and other features. Rack-mounted structures became mainstream in server rooms, with port counts increasing to 16-32 ports. LCD KVM consoles also emerged, integrating display, input, and switching functions within 1U rack space, significantly improving server room space utilization.

Digital IP KVM Stage (2010-2020): With the proliferation of network technology, KVM Over IP (IP KVM) technology matured. KVM Switches broke through local operation limitations, supporting remote server management via LAN and WAN, achieving BIOS-level low-level control, virtual media mounting, multi-user hierarchical permissions, operation log auditing, and other functions. They became core equipment for remote operations and unattended server rooms. Video interfaces also upgraded to HDMI and DP, supporting 4K high-definition resolution.

Intelligent Distributed KVM Stage (2020-present): Distributed KVM and collaborative seating KVM have become mainstream in the high-end market, supporting multi-user, multi-host, multi-screen cross-region collaborative management, adapting to domestic localized (Xinchuang) environments, and integrating intelligent functions such as AI operations, fault prediction, and unified management platforms. They are widely used in high-end scenarios such as command centers, broadcast media, and power dispatch.

Guangzhou Lain Intelligent System Development Co., Ltd. keeps pace with industry technology iterations. Its full series of products covers the entire spectrum from analog to digital, local to remote, and low-end to high-end, with complete independent R&D and production capabilities, providing customized KVM management solutions based on user requirements.

1.3 Product Core Value

The application value of KVM Switches is reflected across five dimensions: cost, efficiency, space, security, and management:

Reducing Hardware Costs: Eliminates the need for independent keyboards, monitors, and mice for each host. Based on a 16-port KVM calculation, it can reduce the procurement cost of 15 sets of peripherals, offering significant long-term cost-effectiveness.

Improving Management Efficiency: Operations personnel no longer need to move between different racks and hosts in the server room. They can quickly switch and manage all devices from a single workstation, increasing troubleshooting and system commissioning efficiency severalfold. Remote IP KVM enables cross-region operations without on-site presence.

Saving Physical Space: Reduces desktop and rack space occupied by numerous peripherals. Especially in high-density server rooms, LCD KVM consoles compress display and switching modules to 1U height, significantly improving server room space utilization.

Ensuring Equipment Security: Reduces interface wear and electrostatic damage risks caused by frequent cable plugging and unplugging. In enclosed server room environments, operations personnel can work externally, reducing dust, temperature, and humidity disturbances from entering the server room. IP KVM’s permission management and log auditing features standardize operational behavior and reduce human operational risks.

Standardizing Operations Management: High-end KVM Switches support user hierarchical authorization, operation log recording, session recording, and other features, meeting compliance requirements such as classified protection (classified protection) and sub-protection (sub-protection), achieving traceable and auditable operations.

1.4 Product Implementation Standards

Our company’s KVM Switch products strictly adhere to relevant national and industry standards in design and production. The main implementation standards include:

Standard Description
GB 4943.1-2022 Safety of Information Technology Equipment – Part 1: General Requirements
GB/T 9254.1-2022 Information Technology Equipment – Radio Disturbance Characteristics – Limits and Methods of Measurement – Part 1: General Requirements
GB/T 17618-2015 Information Technology Equipment – Immunity Characteristics – Limits and Methods of Measurement
GB/T 191-2008 Packaging – Pictorial Marking for Handling and Storage of Goods
YD/T 2165-2010 Technical Requirements and Test Methods for KVM Switches in Telecommunications
FCC Part 15 Class A US Federal Communications Commission Electromagnetic Compatibility Standard
CE EN 55032 EU Electromagnetic Compatibility Standard

All products undergo strict quality testing before leaving the factory, including high/low temperature testing, vibration testing, plug/unplug life testing, electromagnetic compatibility testing, and functional burn-in testing, ensuring stable performance and reliable durability.

Chapter 2: Product Composition

2.1 Core Hardware Components

The hardware structure of a KVM Switch consists of six major parts: the core main control unit, signal input unit, signal output unit, human-machine interaction unit, power unit, and structural enclosure. Component configurations vary slightly between different product types. The following is a general composition description:

2.1.1 Core Main Control Unit

The core main control unit is the “brain” of the KVM Switch, responsible for signal routing, switching control, protocol processing, and function scheduling. It is the core component that determines product performance and compatibility. Its main components include:

  • Main Control Chip: Executes switching logic, OSD menu computation, and signal protocol parsing. High-end IP KVMs also include embedded processors and network processing chips responsible for network transmission, encoding/decoding, user authentication, and other functions.
  • Video Switching Chip: Handles selection and switching of multiple video signals, ensuring no black screens or flickering during switching. High-end models support EDID emulation to ensure the display automatically adapts resolution after switching, avoiding host recognition anomalies.
  • USB/PS2 Control Chip: Responsible for keyboard and mouse signal emulation and forwarding. It simulates peripherals as always online through the HID protocol, preventing host recognition failures caused by peripheral disconnection, while processing hotkey commands, mouse gesture switching, and other functions.
  • Storage Chip: Stores device firmware, OSD interface, user configurations, operation logs, permission information, and other data.
  • Clock Circuit and Reset Circuit: Ensure stable system operation, supporting abnormal reset and firmware upgrades.

2.1.2 Signal Input Unit

The signal input unit is used to connect controlled hosts (servers, computers, workstations, etc.), transmitting the host’s video output signals and peripheral input signals. Each input port corresponds to one controlled device. The main interface types include:

  • Video Input Interfaces: VGA, DVI, HDMI, DP, etc., corresponding to different video signal formats. Some high-end models support SDI, fiber optic, and other long-distance transmission interfaces.
  • Peripheral Input Interfaces: USB Type-B, PS/2 circular ports (purple for keyboard, green for mouse), used to receive keyboard and mouse signals forwarded by the KVM Switch. Some models integrate USB Hub functionality, supporting sharing of U disks, printers, and other peripherals.
  • Extended Input Interfaces: 3.5mm audio input, microphone input, RS232 serial ports, RJ45 network ports (digital KVM), etc.

Each input port is equipped with an independent signal conditioning circuit to ensure signal transmission quality, reducing interference and attenuation. Some models support port hot-plugging, allowing new devices to be connected without restarting the KVM host.

2.1.3 Signal Output Unit

The signal output unit is used to connect control-end peripherals, i.e., the user’s keyboard, mouse, and monitor. It outputs the controlled host’s video signal to the display and forwards keyboard and mouse operation signals to the corresponding host. The main interfaces include:

  • Video Output Interfaces: Corresponding to input interfaces – VGA/HDMI/DVI/DP, etc. Single-console KVMs typically have 1 video output, while multi-console matrix KVMs can have multiple outputs.
  • Peripheral Output Interfaces: USB Type-A, PS/2 interfaces, used to connect local keyboards and mice. Some models have independent USB Hub interfaces for connecting U disks, portable hard drives, and other storage devices.
  • Extended Output Interfaces: 3.5mm audio output, headphone jacks, RS232 serial ports, cascade interfaces, etc.

2.1.4 Human-Machine Interaction Unit

The human-machine interaction unit is the direct carrier for users to operate the KVM Switch, enabling switch command input, status display, menu operations, and other functions. Its main components include:

  • Front Panel Buttons: Port selection buttons, power switch, auto-scan button, etc. Each port has a corresponding status indicator LED showing the currently selected port and device online status.
  • Status Indicator LEDs: Power LED, operation LED, online/selected indicators for each port. Some models include network status LEDs and alarm LEDs.
  • Buzzer: Emits alert sounds during switching operations, power-on, and faults. Can be enabled or disabled via the OSD menu.
  • OSD Display Module: Overlays the operation menu on the video signal. Users can call up the on-screen menu via keyboard for parameter settings, port selection, permission configuration, and other operations.
  • Infrared Receiver Module: Some desktop models support remote control switching and are equipped with an infrared receiving window.

2.1.5 Power Unit

The power unit provides stable DC power supply to the entire unit, ensuring continuous and stable equipment operation. Its main configurations include:

  • Power Input Interface: DC power jack (desktop type), IEC three-prong power connector (rack-mounted type), supporting wide voltage input of 100-240V AC, compatible with global power grid standards.
  • Power Adapter/Built-in Power Module: Desktop types use external power adapters; rack-mounted types use built-in switching power supply modules, all equipped with overvoltage, overcurrent, short-circuit, and over-temperature protection.
  • Ground Terminal: Rack-mounted equipment comes with a dedicated grounding post to ensure proper equipment grounding, improving anti-interference capability and electrical safety.

Some high-end dual-power KVM Switches are equipped with two redundant power supplies. When one fails, the other switches over seamlessly, ensuring uninterrupted equipment operation for high-reliability server room requirements.

2.1.6 Structural Enclosure Unit

The structural enclosure serves for protection, heat dissipation, and mounting fixation. Different product forms have significantly different structures:

  • Desktop Type: Uses ABS engineering plastic or metal enclosure, compact size, with anti-slip rubber feet on the bottom, suitable for desktop placement.
  • Rack-Mounted Type: Uses 1U/2U standard 19-inch rack-mount metal enclosure, made of cold-rolled steel plate, with mounting ears on both sides, installable in standard server cabinets. The enclosure features heat dissipation grilles to ensure ventilation and cooling.
  • LCD Console Type: Uses a drawer-style rack structure, integrating an LCD display, membrane keyboard, and touchpad, equipped with rails and hinges for push-pull folding, fully retracting into the cabinet when not in use.

2.2 Software and Firmware Composition

The software portion of a KVM Switch primarily consists of embedded firmware, i.e., the device’s operating system, stored in the storage chip and responsible for controlling all hardware functions. The main components include:

  • Basic Switching System: Executes port switching logic, signal routing control, and hotkey command parsing. This is the most core functional module.
  • OSD Menu System: Provides a graphical on-screen operation interface, supporting port naming, parameter settings, permission configuration, system information queries, and other operations.
  • Peripheral Emulation System: Continuously emulates keyboard and mouse devices as online, ensuring no peripheral loss or driver anomalies on the host side.
  • Network Management System: Exclusive to IP KVMs, including Web management interface, network protocol stack, video encoding/decoding, user authentication, virtual media, log auditing, and other modules.
  • Upgrade and Maintenance System: Supports local or remote firmware upgrades, continuously optimizing functionality and compatibility.

2.3 Included Accessories

Each KVM Switch ships with standard accessories. Configuration varies slightly between models. Standard included accessories include:

  • KVM dedicated connection cables (quantity corresponds to port count; some models require separate purchase)
  • Power adapter/power cord
  • Rack-mount ears and screws (rack-mount products)
  • Product user manual and certificate of quality
  • Warranty card
  • Rubber feet (desktop products)

Optional accessories include: cascade cables, extenders, remote controls, virtual media licenses, additional connection cables, rack rails, etc. Users can purchase based on actual requirements.

Chapter 3: Product Classification

KVM Switches have a rich product line and can be classified by multiple dimensions. Different classifications correspond to different application scenarios and functional positioning. The following is a detailed classification description.

3.1 Classification by Video Interface Type

The video interface is a core selection indicator for KVM Switches and must match the controlled host’s video output interface. The main categories are as follows:

3.1.1 VGA Interface KVM Switches

The VGA interface is the most classic analog video interface and the most widely used interface type in industrial control and legacy server scenarios.

Parameter Description
Signal Format Analog RGB signal, 15-pin D-Sub interface
Typical Resolution Up to 1920×1080@60Hz, typical transmission distance 5-15 meters
Product Features Mature technology, extremely strong compatibility, low cost, compatible with most legacy servers, industrial PCs, and desktop computers
Applicable Scenarios Traditional server rooms, industrial control sites, legacy equipment maintenance, small to medium projects with limited budgets
Notes Analog signals are prone to attenuation, ghosting, and color shift over long distances; VGA extenders are required for long-distance cabling

3.1.2 DVI Interface KVM Switches

The DVI interface is an interface type transitioning from analog to digital, divided into DVI-A (analog), DVI-D (digital), and DVI-I (compatible with both analog and digital). KVM products primarily use DVI-D.

Parameter Description
Signal Format Digital video signal, supports single-link and dual-link
Typical Resolution Single-link up to 1920×1200@60Hz, dual-link up to 2560×1600@60Hz
Product Features Digital signal with no analog distortion, clear image quality, compatible with some legacy HD devices
Applicable Scenarios Mid-term deployed workstations, server rooms, professional graphics workstation management
Notes DVI interface does not support audio transmission; audio functionality requires separate audio interfaces

3.1.3 HDMI Interface KVM Switches

HDMI is the current mainstream high-definition multimedia interface, supporting simultaneous video and audio transmission. It is the standard interface for consumer and commercial-grade equipment.

Parameter Description
Signal Format Digital high-definition multimedia signal, supports HDCP protocol
Typical Resolution HDMI 1.4 supports 4K@30Hz, HDMI 2.0 supports 4K@60Hz, high-end models support 8K@60Hz
Product Features Simultaneous audio and video transmission, clear image quality, wide compatibility, supports hot-plugging
Applicable Scenarios Modern office workstations, high-definition workstations, security monitoring rooms, home entertainment, small to medium server rooms
Notes Long-distance transmission requires HDMI fiber optic cables or HDMI extenders; bandwidth and functionality differ across HDMI versions

3.1.4 DP Interface KVM Switches

The DP (DisplayPort) interface is the mainstream interface for high-end display devices, offering higher bandwidth and supporting high refresh rates, high resolutions, and multi-screen output.

Parameter Description
Signal Format Digital high-definition display interface, supports FreeSync, G-Sync technologies
Typical Resolution DP 1.2 supports 4K@60Hz, DP 1.4 supports 8K@60Hz, 4K@144Hz
Product Features High bandwidth, high refresh rate, supports Multi-Stream Transport (MST), suitable for professional display scenarios
Applicable Scenarios Gaming studios, video editing workstations, graphic design, high-end collaborative seating scenarios
Notes DP interface comes in standard DP and Mini DP variants; interface form matching must be considered during selection

3.1.5 Mixed Interface KVM Switches

Mixed interface KVM Switches support mixed input of multiple video interfaces, allowing simultaneous connection of devices with VGA, HDMI, DVI, DP, and other different interfaces, with unified output to the control-end display.

Parameter Description
Product Features Extremely strong compatibility, suitable for mixed deployment scenarios of old and new equipment, no additional adapters required
Applicable Scenarios Server rooms during equipment transition, operations scenarios with mixed multi-brand equipment, legacy equipment retrofit projects
Notes The output end must match the monitor interface; some models require adapters for output conversion

3.2 Classification by Device Form and Installation Method

3.2.1 Desktop KVM Switches

Desktop KVM Switches are compact, with simple design, placed on desktops for use. They are the mainstream choice for entry-level and personal office scenarios.

Parameter Description
Port Specifications Common 2-port, 4-port; few 8-port
Structural Features Plastic or thin metal enclosure, anti-slip rubber feet on bottom, front-facing buttons, compact layout
Functional Features Plug-and-play, simple functionality, supports button and hotkey switching, some models support remote control
Applicable Scenarios Personal office dual-computer switching, small studios, home use, small equipment test stations

3.2.2 Rack-Mounted KVM Switches

Rack-mounted KVM Switches use standard 19-inch rack structures, installed in server cabinets. They are core equipment for centralized server room management.

Parameter Description
Port Specifications Common 8-port, 16-port, 32-port, 64-port; supports cascade expansion to more ports
Structural Features 1U/2U height cold-rolled steel plate enclosure, mounting ears on both sides, front and rear interface layout, compatible with standard cabinets
Functional Features Comprehensive functionality, supports OSD menu, hotkey switching, auto-scan, user permissions, cascade expansion; some models support dual redundant power
Applicable Scenarios Enterprise server rooms, data centers, centralized server cabinet management, multi-device operations workstations

3.2.3 LCD KVM Switches (All-in-One Consoles)

LCD KVM Switches, also known as KVM consoles or all-in-one KVM units, integrate an LCD monitor, keyboard, touchpad, and KVM switching module into a 1U rack drawer structure. They are the preferred choice for high-density server rooms.

Parameter Description
Screen Specifications Common 17-inch, 19-inch, 21.5-inch; resolutions from 1280×1024 to 1920×1080
Structural Features 1U height drawer-style design, equipped with slide rails and hinges, push-pull folding, fully hidden in the cabinet when stored
Functional Features Extremely high integration, space-saving, built-in keyboard, mouse, and display, no additional peripherals needed; some models support dual slide rails and folding keyboards
Applicable Scenarios High-density server rooms, cabinet-local operations, space-constrained server room environments, industrial control cabinets

3.2.4 Distributed KVM Nodes

Distributed KVM Switches adopt a node-based architecture, divided into transmit nodes and receive nodes, connected via network switches, enabling flexible matrix-style management.

Parameter Description
Structural Features Split design, transmit nodes connect to hosts, receive nodes connect to operator workstations, networked via IP
Functional Features Flexible deployment, easy expansion, supports multi-user multi-host cross-management, collaborative seating, long-distance transmission
Applicable Scenarios Command centers, dispatch centers, broadcast TV studios, cross-region server room management, multi-seat collaborative scenarios

3.3 Classification by Technical Architecture and Management Method

3.3.1 Analog KVM Switches

Analog KVM Switches use a pure hardware signal switching architecture. Video and peripheral signals are directly switched through hardware circuits without encoding or compression.

Parameter Description
Technical Features No compression, no latency, lossless image quality, plug-and-play, no software configuration required, high stability
Limitations Limited transmission distance, local management only, weak expansion capability, no remote management function
Applicable Scenarios Local short-distance management, industrial scenarios with extremely high latency requirements, budget-limited basic projects

3.3.2 Digital KVM Switches

Digital KVM Switches convert analog signals to digital format for transmission, typically using Cat5/6 network cables as the transmission medium for longer transmission distances.

Parameter Description
Technical Features Convenient network cable cabling, transmission distance up to 50-150 meters, supports cascade expansion, low cabling cost
Limitations Signal undergoes analog-to-digital conversion, slight latency exists; high-end models can control latency to millisecond level
Applicable Scenarios Medium to large server rooms, long-distance cabling scenarios, server room environments with distributed cabinets

3.3.3 IP KVM Switches (KVM Over IP)

IP KVM Switches are based on network transmission technology, encoding KVM signals into network data packets for transmission over LAN/WAN, supporting remote management.

Parameter Description
Technical Features Breaks distance limitations, supports cross-region remote operation, BIOS-level low-level control, virtual media mounting, multi-user permission management, log auditing
Core Advantages No on-site presence required; full lifecycle operations from remote including system installation, troubleshooting, and restart debugging
Applicable Scenarios Unattended server rooms, cross-region branch offices, remote operations teams, cloud server rooms, classified protection compliant server rooms

3.3.4 Matrix KVM Switches

Matrix KVM Switches support multiple inputs and multiple outputs, meaning multiple control consoles can manage multiple hosts simultaneously, with permission allocation and signal sharing.

Parameter Description
Technical Features M×N matrix architecture, arbitrary cross-switching between inputs and outputs, supports picture-in-picture, seating roaming, signal push and capture
High-End Features Collaborative seating, video wall splicing, visual dispatch, hierarchical permissions, seamless switching
Applicable Scenarios Command and dispatch centers, broadcast media, security monitoring centers, multi-department collaborative operations scenarios

3.4 Classification by Port Count

Port Count Description Typical Application
2-Port KVM Switch Entry-level, manages 2 devices Desktop office, dual-computer switching
4-Port KVM Switch Small application, manages 4 devices Small studios, test stations
8-Port KVM Switch Server room entry-level, manages 8 devices Small server rooms, department-level server clusters
16-Port KVM Switch Server room mainstream, manages 16 devices Most common specification for enterprise server rooms, supports cascade expansion
32-Port KVM Switch Medium-large server rooms, manages 32 devices Medium-scale data centers
64-Port and Above KVM Switch Large server rooms, manages 64+ devices Mostly digital matrix architecture, supports multi-level cascading

3.5 Classification by Peripheral Interface Type

Type Description
PS/2 Interface KVM Legacy interface, round purple keyboard port and green mouse port, compatible with legacy servers and industrial PCs, being phased out
USB Interface KVM Mainstream interface, USB keyboard/mouse with strong versatility, supports hot-plugging, compatible with the vast majority of modern devices
PS/2 + USB Dual-Compatible KVM Supports both interface types simultaneously, suitable for mixed old/new device scenarios, strongest compatibility

3.6 Classification by Special Functions

Type Description
KVM Switch with Audio Supports synchronized audio and microphone switching, suitable for multimedia and voice office scenarios
KVM Switch with USB Hub Integrates USB hub, supports sharing of U disks, printers, scanners, and other peripherals
KVM Switch with Virtual Media Exclusive to IP KVMs, supports remote mounting of ISO images and U disks for remote OS installation and file transfer
KVM Switch with Serial Port Management Integrates RS232 serial port management, can simultaneously manage switches, routers, and other network devices
Dual/Multi-Screen KVM Switch Supports synchronized switching for dual or multi-monitor setups, suitable for multi-screen office and graphics workstation scenarios
Industrial-Grade KVM Switch Wide temperature design, anti-interference, anti-corrosion, adapted for industrial sites, outdoor cabinets, and harsh environments

Chapter 4: Product Checklist

4.1 Host Device Checklist

Different KVM Switch models have different host configurations. The following table lists the standard host configurations for the full product series. Users should verify against their purchased model.

Product Series Common Models Port Specifications Video Interfaces Installation Method Standard Power Supply
Desktop VGA Series LA-KVM-2V, LA-KVM-4V 2-port/4-port VGA input ×2/4, VGA output ×1 Desktop placement 12V/1A power adapter
Desktop HDMI Series LA-KVM-2H, LA-KVM-4H 2-port/4-port HDMI input ×2/4, HDMI output ×1 Desktop placement 12V/1.5A power adapter
Rack-Mounted VGA Series LA-KVM-8V, LA-KVM-16V, LA-KVM-32V 8-port/16-port/32-port VGA input ×8/16/32, VGA output ×1 19-inch 1U rack Built-in 100-240V power supply
Rack-Mounted HDMI Series LA-KVM-8H, LA-KVM-16H 8-port/16-port HDMI input ×8/16, HDMI output ×1 19-inch 1U rack Built-in 100-240V power supply
Digital Network Cable KVM Series LA-KVM-8C, LA-KVM-16C 8-port/16-port RJ45 network cable input, VGA/HDMI output 19-inch 1U rack Built-in 100-240V power supply
IP KVM Series LA-IP-8, LA-IP-16, LA-IP-32 8-port/16-port/32-port VGA/HDMI mixed input, IP network output 19-inch 1U rack Built-in 100-240V dual power supply
LCD KVM Console Series LA-LCD-1708, LA-LCD-1916 8-port/16-port VGA/HDMI input, built-in 17/19-inch screen 19-inch 1U rack drawer Built-in 100-240V power supply
Matrix KVM Series LA-MAT-1616, LA-MAT-3232 16-in/16-out, 32-in/32-out HDMI/DP input/output 19-inch 2U rack Built-in 100-240V dual power supply

4.2 Standard Package Checklist

Each KVM Switch product ships with the following items in the package. Upon receipt, please verify against this list and contact the supplier promptly if anything is missing.

4.2.1 Desktop KVM Switch Package Contents

Item Quantity
KVM Switch host ×1
Power adapter ×1
KVM dedicated connection cables Corresponding to port count (2 cables for 2-port, 4 cables for 4-port)
Product user manual ×1
Product certificate of quality ×1
Warranty card ×1
Anti-slip rubber feet ×4

4.2.2 Rack-Mounted KVM Switch Package Contents

Item Quantity
KVM Switch host ×1
Rack-mount ears ×2
Mounting screw kit (screws, nuts, washers) ×1 set
Standard power cord ×1
Product user manual ×1
Product certificate of quality ×1
Warranty card ×1
Serial debugging cable (some models) ×1

4.2.3 LCD KVM Console Package Contents

Item Quantity
LCD KVM console host ×1
Rack-mount rails (left and right rails) ×1 set
Rail mounting screw kit ×1 set
Standard power cord ×1
KVM connection cables Corresponding to port count
Product user manual ×1
Product certificate of quality ×1
Warranty card ×1
Keys (for models with locks) ×2

4.2.4 IP KVM Switch Package Contents

Item Quantity
IP KVM Switch host ×1
Rack-mount ears ×2
Mounting screw kit ×1 set
Standard power cords (dual-power models) ×2
Serial debugging cable ×1
Product user manual ×1
Software license (for virtual media and other features) ×1
Product certificate of quality ×1
Warranty card ×1

4.3 Optional Accessories List

Users can purchase the following optional accessories based on actual application needs:

  • KVM Extension Cables/Extenders: Extend control distance, including VGA extenders, HDMI extenders, USB extenders, and network cable extenders
  • Cascade Cables: Used for cascading multiple KVMs to expand port count
  • Dedicated KVM Cables: KVM dedicated connection cables in various lengths and interface types
  • Interface Adapters: VGA to HDMI, DP to HDMI, Mini DP to DP, and other adapters
  • Remote Control: Infrared remote control for desktop KVMs
  • Virtual Media License: IP KVM function upgrade license
  • Rack PDU Power: Supporting rack power distribution unit
  • Rack Cable Management Panels: Auxiliary server room cabling organization
  • Spare Power Modules: Spare power modules for dual-power models
  • Centralized Management Platform Software: Unified management software for multiple IP KVMs

4.4 Receiving and Acceptance Verification Points

1. Check the outer packaging for integrity, damage, water immersion, or severe compression marks. If any abnormalities are found, refuse delivery on the spot and contact the logistics provider and supplier.

2. After opening, verify against the corresponding model’s package list, confirming the host model, quantity, and all accessories are complete.

3. Inspect the host appearance to confirm no scratches, deformation, paint peeling, interface damage, or other physical damage.

4. Verify the product nameplate, confirming the model, specifications, and production serial number match the purchase contract.

5. Retain all packaging materials and packing lists as evidence for after-sales service and warranty claims.

Chapter 5: Product Working Principles

5.1 Core Working Logic

The core working logic of a KVM Switch is signal routing and peripheral emulation, i.e., establishing dynamically switchable signal paths between multiple controlled hosts and one set of control peripherals, while simulating peripherals as always online to ensure stable device recognition on the host side.

From the signal flow perspective, the entire system is divided into two links – uplink and downlink:

Downlink (Host → Monitor): The controlled host outputs video signals, transmitted to the KVM Switch’s input port. Based on the currently selected port, the switch routes the corresponding video signal to the control-end monitor, allowing the user to see that host’s display.

Uplink (Keyboard/Mouse → Host): The user’s keyboard and mouse operations generate input signals transmitted to the KVM Switch’s console interface. The switch forwards the signals to the currently selected controlled host, which receives the signals and executes the corresponding operations.

The essence of the switching operation is controlling the switching chip to simultaneously switch the video signal path and peripheral signal path, connecting the console to the target host’s signal link and disconnecting from the original host, thereby achieving management target switching.

5.2 Video Signal Switching Principles

5.2.1 Analog Video Switching Principle

For analog video signals represented by VGA, the switching process is pure hardware circuit selection. Inside the KVM Switch, multiple analog video switching chips are integrated. Each input signal passes through a signal conditioning circuit for impedance matching and gain compensation before entering the switching chip’s input channel.

When the user issues a switching command, the main control chip sends channel address signals to the video switching chip. The analog switch array inside the chip activates, connecting the specified input channel to the output channel while disconnecting other channels.

The advantage of analog switching is no compression, no latency, and lossless image quality. The disadvantage is that long-distance transmission is susceptible to interference, and signal attenuation becomes significant when channel counts are high.

5.2.2 Digital Video Switching Principle

For digital video signals such as HDMI, DVI, and DP, switching is divided into two modes: pure hardware pass-through switching and digital matrix switching.

Pure Hardware Pass-Through Switching: Medium and low-end digital KVMs use high-speed digital switching chips. TMDS signals are directly switched through switch arrays without encoding or decoding, providing extremely low latency and lossless image quality. However, transmission distance is limited, and each channel requires an independent transmission path.

Digital Matrix Switching: High-end digital KVMs and IP KVMs decode, scale, and encode the input digital video signals before transmitting them through internal buses or networks to the output end. This enables complex functions such as multi-screen splitting, remote transmission, and resolution adaptation, but introduces slight latency.

5.2.3 EDID Emulation Principle

EDID (Extended Display Identification Data) is the parameter information stored in a monitor about itself. Hosts identify the monitor’s resolution, refresh rate, and other parameters by reading EDID, and output video signals of the corresponding specifications.

During ordinary KVM switching, hosts may re-detect EDID because the monitor is disconnected, causing resolution changes, black screens, and recognition anomalies. To solve this problem, high-end KVM Switches have built-in EDID emulation functionality, where each input port emulates a virtual EDID data set, making the host always believe the monitor remains connected. When switching occurs, no re-recognition is needed, achieving seamless switching and avoiding screen flicker and resolution anomalies.

5.3 Keyboard and Mouse Signal Working Principles

5.3.1 Peripheral Emulation and Always-Online Mechanism

Early computers did not support peripheral hot-plugging. After disconnecting a keyboard or mouse and reconnecting, the host needed to be restarted for recognition. Even though modern systems support hot-plugging, frequent disconnection can still cause driver anomalies and device recognition failures.

Through built-in USB HID/PS2 controllers, KVM Switches emulate virtual keyboard and mouse devices on each host port, continuously sending device-online signals to the host. Regardless of whether the current port is selected, the host believes the keyboard and mouse remain connected. During switching, the real keyboard and mouse signals are directly injected into the corresponding channel, achieving immediate switching without the host needing to re-recognize peripherals.

5.3.2 Hotkey Command Parsing Principle

Hotkey switching is the most commonly used switching method for KVMs. Users issue switching commands by pressing specific key combinations on the keyboard. The working principle is as follows:

The KVM’s main control chip continuously monitors keyboard input signals. When a preset hotkey combination (such as pressing Scroll Lock twice consecutively, or Ctrl+Alt+number) is detected, it is recognized as a KVM control command rather than a normal input signal sent to the host, subsequently executing the corresponding switching, menu invocation, auto-scan, and other operations.

To avoid conflicts with common software hotkeys, KVM hotkeys typically use uncommon key combinations and support user-customized hotkeys to accommodate different usage habits.

5.3.3 Mouse Gesture Switching Principle

Some high-end KVMs support mouse border switching, where the mouse cursor automatically switches to the next host when moved to the screen edge. The principle is that the KVM chip parses mouse coordinates in real time. When the cursor reaches the left/right screen boundary and continues moving, it triggers port switching while mapping the mouse coordinates to the corresponding position on the new host’s screen, achieving seamless cross-screen switching. This is mainly used in multi-host, multi-screen office scenarios.

5.4 IP KVM Working Principle

IP KVM (KVM Over IP) is a network-based remote KVM technology. Its core is video encoding and network transmission. The working principle is as follows:

Signal Acquisition: Video, keyboard/mouse, serial, and other signals from the controlled host are connected to the IP KVM’s local ports. Video signals are digitized by the acquisition chip.

Encoding and Compression: The embedded processor compresses video signals using H.264/H.265 or other formats. Keyboard, mouse, and other control signals are encapsulated into network data packets.

Network Transmission: The encoded audio/video stream and control data packets are transmitted over Ethernet, routable through LAN, WAN, and the Internet.

Decoding and Output: Remote clients receive network data via web browsers or dedicated client software, decode and display the video image, while packaging local keyboard and mouse operations as data packets sent back to the IP KVM host.

Command Execution: The IP KVM host receives control commands and forwards them to the corresponding controlled host, enabling remote operation.

The core advantage of IP KVM is breaking through physical distance limitations while supporting BIOS-level control. Even if the host operating system crashes or the network card fails, as long as the host is powered on and video output is normal, remote takeover is possible – something remote desktop software cannot achieve. Additionally, IP KVM supports virtual media functionality, virtualizing local ISO images and U disk files as the controlled host’s optical drive or U disk, enabling remote OS installation, file transfer, firmware upgrades, and other operations.

5.5 Matrix KVM Working Principle

The matrix KVM adopts an M×N crossbar switch architecture with M inputs and N outputs. Any input can be switched to any output, supporting multiple users operating different host computers simultaneously.

High-end distributed matrix KVM systems adopt a transmitter node + receiver node architecture, networked via gigabit/10-gigabit switches. The transmitter node captures the host signal, encodes it, and sends it to the network; the receiver node retrieves the corresponding signal from the network, decodes it, and outputs it, achieving flexible matrix switching. This architecture offers exceptional scalability — nodes can be added or removed at any time, supports long-distance transmission across buildings and campuses, and simultaneously supports advanced collaboration features such as operator seat roaming, screen push, and video wall splicing.

5.6 Cascade Expansion Working Principle

When the number of ports on a single KVM is insufficient, the port count can be expanded via cascading. The cascading principle is to connect the console ports of the subordinate KVM to one input port of the superior KVM, effectively treating the entire subordinate KVM as one managed device of the superior unit.

To operate, the user first switches to the corresponding cascade port on the superior KVM, then operates the subordinate KVM to switch to the specific host port. In theory, multi-level cascading is possible; however, the more cascade levels, the higher the operational complexity. It is generally recommended not to exceed 3 cascade levels to avoid cumbersome switching and signal attenuation.

This chapter provides technical parameter specifications for the full series of KVM switches manufactured by Guangzhou Lain Intelligent System Development Co., Ltd. Parameters vary by model; the product nameplate shall prevail. The following lists the common parameters for each series and typical model parameters.

6.1 General Electrical Parameters

Parameter Item Desktop Series Rack-Mount Analog Series IP KVM Series LCD All-in-One Series
Supply Voltage DC 12V/1A AC 100-240V 50/60Hz AC 100-240V 50/60Hz AC 100-240V 50/60Hz
Rated Power Consumption ≤5W ≤15W (16-port) ≤30W (16-port) ≤45W (19-inch)
Power Redundancy None Optional dual power Standard dual power Optional dual power
Grounding Requirement Optional Must be reliably grounded Must be reliably grounded Must be reliably grounded
Insulation Resistance ≥100MΩ ≥100MΩ ≥100MΩ ≥100MΩ
Dielectric Strength 1500V AC/1min 1500V AC/1min 1500V AC/1min 1500V AC/1min

6.2 Video Performance Parameters

6.2.1 VGA Series Video Parameters

  • Video Interface: VGA HD15 female
  • Signal Type: Analog RGBHV
  • Input Impedance: 75Ω
  • Bandwidth: 250MHz (-3dB)
  • Maximum Resolution: 1920×1440@60Hz
  • Recommended Resolutions: 1920×1080@60Hz, 1600×1200@60Hz, 1280×1024@60Hz
  • Input Transmission Distance: ≤15 meters (standard VGA cable)
  • Output Transmission Distance: ≤5 meters (standard VGA cable)
  • EDID Emulation: Supported (high-end models)
  • Switching Speed: ≤1 second

6.2.2 HDMI Series Video Parameters

  • Video Interface: HDMI Type-A female
  • Protocol Version: HDMI 1.4 / HDMI 2.0
  • Bandwidth: HDMI 1.4: 10.2Gbps; HDMI 2.0: 18Gbps
  • Maximum Resolution:
  • HDMI 1.4: 4096×2160@30Hz, 3840×2160@30Hz, 1920×1080@60Hz
  • HDMI 2.0: 4096×2160@60Hz, 3840×2160@60Hz, 1920×1080@144Hz
  • Color Depth: 8bit/10bit/12bit
  • Audio Support: LPCM 7.1, Dolby TrueHD, DTS-HD Master Audio
  • HDCP: Supports HDCP 1.4/2.2
  • Input Transmission Distance: ≤10 meters (standard HDMI copper cable)
  • EDID Emulation: Supported
  • Switching Speed: ≤1.5 seconds

6.2.3 DP Series Video Parameters

  • Video Interface: Standard DisplayPort female
  • Protocol Version: DP 1.2 / DP 1.4
  • Bandwidth: DP 1.2: 21.6Gbps; DP 1.4: 32.4Gbps
  • Maximum Resolution:
  • DP 1.2: 4096×2160@60Hz, 2560×1440@144Hz, 1920×1080@165Hz
  • DP 1.4: 7680×4320@60Hz, 4096×2160@144Hz
  • Color Depth: 8bit/10bit/12bit
  • Multi-Monitor Support: Supports MST multi-stream transport
  • HDCP: Supports HDCP 2.2
  • Input Transmission Distance: ≤10 meters (standard DP cable)
  • EDID Emulation: Supported
  • Switching Speed: ≤1.5 seconds

6.3 Peripheral Interface Parameters

6.3.1 USB Interface Parameters

  • Interface Type: USB 2.0 / USB 3.0
  • Keyboard/Mouse Interface: USB HID class, compatible with USB 1.1
  • Sharing Interface: USB 2.0 High Speed, 480Mbps (models with Hub function)
  • Supported Devices: Keyboard, mouse, USB flash drive, external hard drive, printer, scanner, etc.
  • Hot-Plug Support: Yes
  • Power Supply Capability: Maximum 500mA per port
  • Compatibility: Compatible with mainstream operating systems including Windows, Linux, Mac OS, Unix, etc.

6.3.2 PS/2 Interface Parameters

  • Interface Type: 6-pin Mini-DIN, purple for keyboard, green for mouse
  • Protocol: PS/2 keyboard/mouse protocol
  • Compatibility: Compatible with legacy PCs, servers, and industrial computers
  • Hot-Plug Support: Not supported; hot-plugging may damage the device
  • Note: Newer models are phasing out PS/2 interfaces, prioritizing USB interfaces

6.4 Network Parameters (IP KVM Series)

  • Network Port: RJ45 gigabit Ethernet port, 10/100/1000Mbps auto-negotiation
  • Network Protocols: TCP/IP, HTTP, HTTPS, DHCP, DNS, SSH, Telnet, SNMP
  • Video Encoding: H.264 / H.265 adaptive encoding
  • Transmission Latency: LAN ≤30ms; WAN depends on network bandwidth and latency
  • Maximum Concurrent Users: 1 local + 2-8 remote (depending on model)
  • Virtual Media: Supports ISO images, USB flash drive, external hard drive virtual mounting
  • Management Methods: Web browser, dedicated client software
  • Security Encryption: AES 256-bit data encryption, HTTPS management, user password authentication
  • Log Functions: Operation logs, login logs, system logs, supports log export

6.5 Mechanical and Environmental Parameters

6.5.1 Structural Dimension Parameters

  • Desktop 2-port: 110mm × 75mm × 25mm (L × W × H)
  • Desktop 4-port: 160mm × 90mm × 28mm
  • Rack-Mount 1U: 440mm × 180mm × 44mm (standard 19-inch rack, 1U height)
  • Rack-Mount 2U: 440mm × 280mm × 88mm
  • LCD All-in-One 1U: 440mm × 520mm × 44mm (depth includes rails)

6.5.2 Environmental Parameters

  • Operating Temperature: 0℃ ~ 50℃
  • Storage Temperature: -20℃ ~ 60℃
  • Operating Humidity: 10% ~ 80% RH, non-condensing
  • Storage Humidity: 5% ~ 90% RH, non-condensing
  • Atmospheric Pressure: 86kPa ~ 106kPa
  • Industrial-Grade Models: Operating temperature -20℃ ~ 60℃, supports wide-temperature environments

6.5.3 Reliability Parameters

  • Mean Time Between Failures (MTBF): ≥100,000 hours
  • Button Life: ≥100,000 cycles
  • Connector Insertion/Extraction Life: ≥10,000 cycles
  • Cooling Method: Natural convection cooling, fanless design (some high-power models feature silent fans)

6.6 Functional Parameters

Function Item Desktop Rack-Mount Analog IP Type LCD All-in-One Matrix Type
Button Switching ✅ ✅ ✅ ✅ ✅
Hotkey Switching ✅ ✅ ✅ ✅ ✅
OSD Menu ❌ ✅ ✅ ✅ ✅
Auto Scan ❌ ✅ ✅ ✅ ✅
Port Naming ❌ ✅ ✅ ✅ ✅
Cascade Expansion ❌ ✅ ✅ ✅ ❌
Remote Access ❌ ❌ ✅ Optional ✅
Virtual Media ❌ ❌ ✅ Optional Optional
User Permissions ❌ Basic Multi-level Basic Multi-level
Operation Logs ❌ ❌ ✅ ❌ ✅
Audio Switching Optional Optional ✅ Optional ✅
USB Sharing Optional Optional ✅ Optional ✅
Multi-Screen Expansion ❌ Optional Optional ❌ ✅

7.1 Core Basic Functions

7.1.1 Centralized Management of Multiple Devices

The core function is to manage multiple host computers with a single set of keyboard, monitor, and mouse, supporting 2-64 ports and cascade expansion. This thoroughly resolves the problem of redundant peripherals across multiple devices, allowing operations and maintenance personnel to complete management of all equipment from a single workstation, greatly improving management efficiency.

7.1.2 Multiple Switching Methods

The full product series supports multiple switching methods to accommodate different operating habits and scenarios:

  • Panel Button Switching: Switch ports directly via physical buttons on the front panel. Intuitive and convenient, suitable for quick local operations. Each button has a status indicator clearly showing the currently selected port.
  • Keyboard Hotkey Switching: Quickly switch using keyboard key combinations without leaving the workstation. This is the most commonly used switching method in data center operations. Supports direct port selection via number keys, up/down cycling, etc.
  • OSD Menu Switching: Bring up a visual on-screen menu and select the target port via keyboard. Supports port search and categorized display, suitable for scenarios with a large number of ports.
  • Auto Scan Switching: Set an automatic scan interval, and the KVM automatically cycles through all ports. Suitable for equipment room inspection and monitoring duty scenarios. The scan port range and interval can be customized.
  • Mouse Gesture Switching: High-end models support automatic switching when the mouse moves to the screen edge. Suitable for multi-host collaborative office scenarios with smooth, natural operation.
  • Remote Control Switching: Some desktop models support infrared remote control switching, suitable for remote desktop operation.
  • Software/Web Switching: IP KVMs support remote switching via client software and web interfaces, including scheduled switching and batch operations.

7.1.3 Plug-and-Play, Driver-Free

All analog KVMs and basic digital KVMs use pure hardware design requiring no driver software installation. Simply connect the cables and power on to use. Compatible with all host devices with standard interfaces, including Windows, Linux, Mac OS, Unix, and domestic operating systems. Exceptional adaptability and quick, simple deployment.

7.1.4 High Compatibility and Signal Emulation

  • Built-in EDID emulation simulates a continuously connected monitor, preventing the host from losing the display device during switching and avoiding issues such as resolution confusion, black screens, and restart re-detection.
  • Built-in USB HID emulation simulates continuously connected keyboard and mouse, supporting full recognition during system startup. Normal operation is available in BIOS, CMOS, and safe mode, meeting low-level maintenance requirements.
  • Supports mechanical keyboards, wireless keyboard/mouse sets, touchpads, and various other peripherals with broad compatibility.

7.2 Advanced Management Functions

7.2.1 OSD On-Screen Display Menu System

Rack-mount and above models are equipped with an OSD (On Screen Display) menu system with rich features and convenient operation:

  • Port Management: Port naming, port sorting, port blocking, port status display
  • System Settings: Hotkey customization, buzzer on/off, auto scan interval settings, EDID configuration
  • User Management: Administrator/general user hierarchy, permission assignment, password settings
  • Information Query: Device model, firmware version, uptime, port status
  • Language Support: Simplified Chinese, English, and other multi-language menus

7.2.2 Cascade Expansion Function

Supports multi-level cascading. When a single unit’s ports are insufficient, multiple KVMs can be expanded via cascade cables, expanding up to hundreds of ports to meet the expansion needs of small and medium-sized equipment rooms. After cascading, unified OSD menu and hotkey operation remain available, maintaining clear management logic.

7.2.3 Audio and USB Peripheral Sharing

  • Supports 3.5mm audio and microphone simultaneous switching with audio-video synchronization, suitable for multimedia office and voice conferencing scenarios.
  • Built-in USB Hub function supports sharing of USB peripherals such as USB flash drives, external hard drives, printers, and scanners. Peripherals switch simultaneously when switching hosts, eliminating the need for separate plugging/unplugging and improving peripheral utilization.

7.3 IP KVM Exclusive Advanced Functions

7.3.1 Cross-Region Remote Management

Breaks through physical distance limitations. Equipment room devices can be managed remotely via LAN, WAN, or the Internet. Regardless of location, servers can be controlled just as if operating locally, significantly reducing travel costs for maintenance and improving fault response speed.

7.3.2 BIOS-Level Low-Level Control

Operates independently of the host operating system. Even if the host system crashes, displays a blue screen, has a network card failure, or is in the BIOS startup phase or safe mode, remote takeover remains fully functional. Enables system reinstallation, fault diagnosis, BIOS configuration, and other low-level maintenance operations. This is a core advantage that software solutions such as remote desktop and bastion hosts cannot replace.

7.3.3 Virtual Media Function

Supports virtualizing local ISO image files, USB flash drives, external hard drives, and optical drives as local storage devices for the managed host. System installation, driver upgrades, file transfer, and firmware updates can all be completed remotely without physically inserting or removing storage media on-site, greatly improving remote maintenance efficiency.

7.3.4 Multi-Level User Permission Management

Supports a multi-user account system with different roles including super administrator, administrator, general operator, and guest. Different port permissions and operational permissions can be assigned to implement tiered maintenance, prevent unauthorized operations, and ensure device security.

7.3.5 Operation Audit and Logs

Comprehensively records all user activities including login, switching, operation, and logout, generating detailed operation logs. Supports log query, filtering, and export. Some models support session video recording and playback, meeting Level Protection 2.0 (Level Protection2.0) and industry compliance audit requirements, ensuring full traceability of maintenance operations.

7.3.6 Multi-Device Integrated Management

Supports serial port management for simultaneous control of network devices such as switches, routers, and firewalls via their serial consoles. Supports intelligent PDU integration for remote server power cycling and on/off management, creating an integrated remote maintenance platform.

7.4 Matrix KVM Exclusive Collaboration Functions

7.4.1 Matrix Cross-Point Switching

Any input signal can be switched to any output. Supports multiple users operating different hosts simultaneously without interference, meeting collaborative maintenance needs across multiple departments and workstations.

7.4.2 Operator Seat Collaboration and Roaming

Supports operator personnel using a single set of keyboard, mouse, and monitor to roam across multiple host signals. Supports screen push and pull, allowing rapid screen sharing between different operator seats. Improves collaboration efficiency and is suitable for command centers and dispatch halls.

7.4.3 Multi-Picture Display

Supports screen splitting, picture-in-picture, and screen stitching functions. A single screen can simultaneously display multiple host images for real-time monitoring of multiple devices, suitable for surveillance duty scenarios.

7.5 Product Core Features

7.5.1 Stable, Reliable, Industrial-Grade Quality

  • Utilizes industrial-grade main control chips and electronic components with stringent production testing processes. MTBF exceeds 100,000 hours, ensuring stable 7×24 continuous operation.
  • All-metal rack structure with anti-interference, anti-static, and anti-corrosion properties, suitable for complex electromagnetic environments in equipment rooms.
  • Built-in multiple protections including overvoltage, overcurrent, short circuit, and overheat protection. Wide-voltage power input design adapts to unstable grid environments.
  • Fanless silent heat dissipation design (most models) avoids fan noise and dust ingress, extending device lifespan. Suitable for quiet office and equipment room environments.

7.5.2 High-Definition Lossless, Low-Latency Switching

  • Analog models use high-bandwidth switching chips for lossless video signal transmission with clear image quality and no attenuation. Fast switching speed with no obvious black screen delay.
  • Digital models use high-definition video processing technology supporting 4K@60Hz high-definition picture quality. High-end models achieve switching latency below 10ms, virtually imperceptible to the human eye.
  • IP models use H.265 intelligent encoding, maintaining clear and smooth images even at low bandwidth. LAN latency below 30ms provides highly responsive operation.

7.5.3 Flexible Deployment, Strong Scalability

  • Multiple form factors including desktop, rack-mount, LCD, and distributed types to suit different installation scenarios.
  • Supports cascade expansion and node expansion, allowing gradual capacity growth as business expands, protecting initial investment.
  • Rich interface configurations and optional accessories to suit various new and legacy devices, deployable without large-scale renovation.

7.5.4 Security Compliant, Controllable Maintenance

  • IP KVMs support AES 256-bit encrypted transmission, HTTPS security management, and account/password authentication to ensure data transmission security.
  • Comprehensive permission and audit systems meet Level Protection (classified protection), classified protection, and industry regulatory compliance requirements.
  • Supports adaptation to domestic (Chinese) operating systems and hardware, meeting Xinchuang (Xinchuang) project requirements.

7.5.5 Simple Maintenance, Rapid Fault Resolution

  • Clear status indicator lights for convenient fault location. Power, port, and network operating status can be viewed directly from the front panel.
  • Supports firmware upgrades with continuous functional and compatibility optimization.
  • Standardized interface design with high accessory interchangeability for convenient maintenance and replacement.

KVM switches are applied across all industries. Any scenario requiring centralized management of multiple devices can benefit from KVM switches to improve management efficiency. The following details typical application scenarios.

8.1 Data Center and Enterprise Equipment Room Scenarios

Data centers and enterprise equipment rooms are the core application scenarios for KVM switches, where servers, storage devices, and network devices are numerous and require centralized maintenance management.

  • Small and Medium Equipment Rooms: Use 16-port/32-port rack-mount KVM switches paired with LCD KVM all-in-one units. All server local maintenance can be completed from the front of the rack without entering the cabinet interior, improving maintenance efficiency and safety.
  • Medium and Large Data Centers: Use digital KVM or IP KVM architectures with network cable or network connections to distributed rack equipment. Maintenance personnel can manage the entire equipment room from the monitoring room, supporting multi-person tiered maintenance.
  • Unattended Equipment Rooms: Use IP KVM switches for 7×24 remote maintenance. When faults occur, engineers do not need to travel to the site; troubleshooting and resolution can be completed remotely, significantly reducing maintenance costs and shortening fault response time.
  • High-Density Racks: Use LCD KVM slide-out all-in-one units. 1U of space integrates display, input, and switching functions, saving rack space and increasing deployment density.

8.2 Industrial Control and Automation Scenarios

In industrial production sites, automated production lines, and smart factories, there are numerous industrial computers, PLCs, and industrial PCs operating in harsh environments with dispersed equipment. KVM switches are the ideal choice for industrial control management.

  • Production Line Centralized Control: Multiple industrial computers on one production line are centrally managed through industrial-grade KVM switches. Operators at central control stations can switch between equipment at different workstations without walking along the production line.
  • Harsh Environment Adaptation: Industrial-grade KVMs support wide temperature, wide voltage, anti-interference, and anti-corrosion, adapting to harsh workshop environments with high temperature, high humidity, and strong electromagnetic interference. Stable and reliable.
  • Control Cabinet Integration: LCD KVM all-in-one units are integrated into industrial control cabinets, stored away when idle to save cabinet space, and pulled out for use when needed. Convenient and efficient.

8.3 Office and Creative Design Scenarios

8.3.1 Dual-Computer Office Scenario

Professionals often have a desktop office computer plus a laptop, or a work computer plus a classified computer. A desktop 2-port KVM switch allows one set of keyboard, mouse, and monitor to control both computers with one-touch switching. Keeps the desktop tidy, improves work efficiency, and eliminates frequent cable plugging/unplugging and turning the head between two screens.

8.3.2 Design and Editing Studio

Graphic design, video editing, and 3D modeling studios often have multiple workstations. Multi-screen KVM switches supporting dual-screen/quad-screen simultaneous switching allow designers to switch between different workstations with one set of keyboard and mouse, accessing project resources from different machines, improving work efficiency and reducing desktop peripheral clutter.

8.3.3 Customer Service and Call Center

Customer service stations are equipped with office computers plus business system hosts. KVM switches with audio support provide synchronized audio-video switching, allowing agents to flexibly switch between different systems. Clean desktop and convenient operation.

8.4 Security and Surveillance Scenarios

In security monitoring rooms and command dispatch rooms, multiple surveillance hosts, DVRs, NVRs, and decoding devices require centralized management. KVM switches play an important role.

  • Monitoring Room Multi-Device Management: Multiple surveillance hosts and matrix devices are centrally managed through KVM switches. Duty personnel can operate all surveillance devices with one set of keyboard and mouse — retrieving images, setting parameters — keeping the console clean and organized.
  • Video Wall Control: Matrix KVMs paired with video wall systems enable any surveillance image to be displayed on the wall and any operator seat to control any host, improving dispatch efficiency.

8.5 Broadcasting and Media Scenarios

Broadcast studios, broadcast equipment rooms, and post-production rooms contain precision equipment with high image quality requirements. Professional KVM devices can meet these needs.

  • Broadcast Equipment Room Management: Multiple broadcast servers, subtitle machines, and graphics devices are centrally managed through KVMs. Operators can quickly switch between different devices to ensure broadcast safety.
  • Post-Production Room: Multiple editing workstations and render servers are managed through KVMs, allowing editors to switch between machines efficiently and improving production efficiency.
  • Studio Operator Seat Collaboration: Distributed matrix KVMs enable collaborative work among director, subtitle, and audio control operator seats with flexible signal scheduling for efficient, smooth program production.

8.6 Education and Research Scenarios

  • Computer Laboratories: Multiple teaching computers in school computer rooms and laboratories are centrally managed through KVM switches. Teachers can switch to and operate any student computer from the lectern to demonstrate teaching content without operating each machine individually.
  • Research Server Clusters: Computing servers and experimental equipment at research institutions are remotely managed through IP KVMs, allowing researchers to operate experimental equipment and servers remotely from their offices without being physically present in the laboratory.

8.7 Finance and Securities Scenarios

The financial industry has extremely high requirements for system stability, security, and compliance. KVM switches are standard equipment in trading rooms and data centers.

  • Trading Terminal Management: Traders centrally operate multiple trading hosts through KVMs, quickly switching between different trading systems to improve trading efficiency.
  • Compliance Auditing: IP KVM operation logs and recording functions meet financial industry maintenance audit requirements. All operations are traceable, ensuring trading system security.
  • High-Reliability Redundancy: Dual-power KVM switches paired with redundant power systems ensure uninterrupted operation of trading systems.

8.8 Government and Classified Scenarios

Government equipment rooms, classified units, and secure rooms have strict information security requirements. Domestic KVM switches can meet compliance requirements.

  • Domestic Adaptation: Supports domestic operating systems and domestic servers, adapting to Xinchuang environments and meeting independent controllability requirements.
  • Physical Isolation: Analog KVMs use pure hardware switching with no network leakage risk, ensuring classified information security.
  • Permission Control: Multi-level user permissions and operation auditing meet confidentiality management standards.

8.9 Testing and R&D Scenarios

Software testing and hardware R&D departments often need to operate multiple test devices and test hosts simultaneously. KVM switches can significantly improve testing efficiency.

  • Multi-System Testing: Testing hosts with different operating systems and hardware configurations. One-touch KVM switching allows testers to efficiently complete compatibility testing and functional testing.
  • Burn-In Test Rooms: Batch test devices are centrally managed through KVMs, allowing inspection personnel to quickly switch between devices to check status, improving testing efficiency.

9.1 Pre-Installation Preparation

9.1.1 Environment Inspection

Before installation, the installation environment must be inspected to ensure it meets equipment operating requirements:

  • Temperature and Humidity Check: Installation environment temperature should be between 0℃-50℃, humidity 10%-80% non-condensing. Avoid installation in locations with direct sunlight, near heat sources, in damp or dusty areas.
  • Space Check: Desktop installation requires sufficient table space with at least 5cm of heat dissipation clearance around the device. Rack installation requires confirming the corresponding U-space is available in the cabinet, with front and rear clearance for cabling and operation.
  • Power Check: Confirm the supply voltage meets equipment requirements (100-240V AC), power grounding is good, and it is recommended to connect to a UPS uninterruptible power supply to ensure stable equipment operation.
  • Electromagnetic Environment: Avoid installation near strong electromagnetic interference sources such as high-power motors, transformers, or RF equipment.
  • Load-Bearing Check: For rack installation, confirm the cabinet posts can support the equipment weight. For LCD all-in-one units, confirm the rack rail mounting positions have sufficient strength.

9.1.2 Tool and Material Preparation

Prepare the necessary tools and materials before installation to avoid interruptions:

  • Tools: Phillips screwdriver (PH2), flat-head screwdriver, diagonal cutters, cable ties, anti-static wrist strap, label paper, marker pen, multimeter (optional).
  • Materials: KVM connection cables of appropriate length, network cables (digital/IP KVM), power strips, cable management racks (equipment room scenarios), label stickers.
  • Equipment: KVM switch main unit, included accessories, managed hosts, console keyboard, mouse, and monitor.

9.1.3 Safety Precautions

  • Anti-Static: Installation personnel must wear anti-static wrist straps to avoid static damage to internal components. Before touching equipment, first touch grounded metal to discharge static.
  • Power-Off Operation: All wiring operations must be performed with equipment powered off. Avoid hot-plugging interfaces which may damage equipment, especially PS/2 interfaces where hot-plugging is strictly prohibited.
  • Handle with Care: The equipment is precision electronic equipment. Avoid impacts and drops during transport and installation. For LCD all-in-one units, protect the screen from pressure and scratches.
  • Standardized Cabling: Separate high-voltage and low-voltage cables. Avoid tangled or knotted cables. Reserve cable slack to avoid pulling on connectors.

9.2 Desktop KVM Switch Installation

Desktop KVM installation is simple and suitable for personal office and small workstation scenarios. Installation steps:

1. Location Selection: Choose a flat, dry, well-ventilated desktop location. Place the KVM switch in an appropriate position with the anti-slip pads on the bottom attached, ensuring the device sits stably without sliding.

2. Orientation Adjustment: Face the interface side toward the managed hosts and the operation button side toward the operator for convenient operation and cabling.

3. Space Reservation: Reserve at least 5cm of space around the device for ventilation and heat dissipation. Do not place books, papers, or other items on top of the device to avoid poor heat dissipation.

4. Temporary Fixation: For long-term fixation, double-sided tape or a desktop mounting bracket can be used to secure the device and prevent accidental movement.

9.3 Rack-Mount KVM Switch Installation

Rack-mount KVMs are installed in standard 19-inch server cabinets and are the mainstream installation method for equipment room scenarios. Installation steps:

9.3.1 Installation Position Planning

  • Select an appropriate U-position based on the cabinet layout. Typically installed in the upper-middle portion of the cabinet for convenient operation and cabling, away from heat exhaust vents and high-voltage areas.
  • Confirm the cabinet square-hole rails meet the standard 19-inch specification and check that mounting holes are intact.
  • Plan cable routing paths. Input cables enter from the rear of the cabinet, outputs face the operating side. Route high-voltage and low-voltage cables separately through cable management racks on both sides.

9.3.2 Rack Ear Installation

1. Remove the KVM main unit, mounting ears, and screw kit from the package.

2. Align the rack ears with the mounting holes on both sides of the main unit and secure them with the included screws. Tighten screws with moderate force to avoid stripping threads.

3. Confirm the rack ears are securely mounted with no looseness.

9.3.3 Cabinet Fixation

1. With two people assisting, lift the KVM main unit to the corresponding U-position and align the rack ear mounting holes with the holes on the cabinet square-hole rails.

2. Insert locating pins or temporarily install screws on one side first, then adjust the other side into position and install all fixing screws after alignment.

3. Use a Phillips screwdriver to tighten all screws evenly, ensuring the device is mounted level and securely without wobbling.

4. Verify the device is installed level with no tilt or looseness, with appropriate front-to-back depth that does not interfere with cabinet door opening and closing.

9.3.4 Grounding

1. Locate the grounding terminal on the rear of the device. Use a grounding wire to reliably connect the grounding terminal to the cabinet grounding busbar.

2. Confirm the grounding resistance meets requirements to ensure the device’s anti-interference capability and electrical safety.

9.4 LCD KVM All-in-One Installation

The LCD KVM all-in-one has a complex structure requiring high installation precision. Strictly follow the steps to avoid damaging the rails and screen.

9.4.1 Rail Installation

1. Remove the left and right rail kits. Distinguish the inner rail, middle rail, and outer rail. Typically the outer rail is fixed to the cabinet and the inner rail is fixed to the device body.

2. Adjust the rail mounting hole positions according to cabinet depth. Align the outer rails with the cabinet square-hole rails and secure them to the side posts at the corresponding U-position. Keep both left and right rails at the same horizontal level.

3. Use a spirit level to confirm the rails are level, parallel, and at the correct spacing to ensure smooth device sliding.

9.4.2 Main Unit Installation

1. With two people assisting, lift the LCD all-in-one main unit and align the inner rails on both sides with the slide channels of the cabinet outer rails. Push in smoothly.

2. Push until the locking position is reached. Listen for the click of the latch engaging and confirm the device is securely locked.

3. Slowly pull out the device and test that sliding is smooth with no jamming or offset. Confirm the rail locking and unlocking functions operate normally.

4. Open the screen and keyboard, testing that hinge damping is appropriate, the screen opens and closes smoothly without looseness or abnormal noise.

9.4.3 Cabling and Finishing

1. Connect the power cable and input cables. Organize cables along the rail cable channels, reserving sufficient slack for push-pull travel to avoid pulling cables when sliding the device.

2. Use cable ties to secure cables at the rail cable management positions, ensuring cables do not tangle or jam.

3. Test the full push-pull travel of the device. Cables should not be pulled or snagged, and the device should operate normally.

9.5 Distributed KVM Node Installation

Distributed KVMs are divided into transmitter nodes and receiver nodes with flexible installation. Deployment methods:

  • Transmitter Node Installation: Install transmitter nodes close to the managed hosts. They can be placed on cabinet shelves or secured inside the cabinet with rack ears. The closer to the host, the better, to shorten input cable length and ensure signal quality.
  • Receiver Node Installation: Install receiver nodes at operator workstations. They can be placed on the desktop, mounted under the workstation, or behind the monitor. The closer to the keyboard, mouse, and monitor, the better.
  • Network Deployment: Connect nodes to switches via gigabit network cables. Plan the network topology and ensure sufficient network bandwidth. It is recommended to use dedicated gigabit/10-gigabit switches isolated from the business network to ensure transmission stability.

9.6 Post-Installation Inspection

After equipment installation is complete, perform the following checks to confirm installation quality:

  • Physical Fixation Check: Equipment is securely installed with no looseness, wobble, or tilt. All screws are present and tightened.
  • Space and Heat Dissipation Check: Sufficient heat dissipation space around the device, no obstructions, good ventilation.
  • Grounding Check: Rack-mount equipment is reliably grounded with secure grounding wire connections.
  • Appearance Check: No damage to the equipment appearance, no scratches on the screen, no deformed connectors.
  • Labeling Check: Apply labels to each port indicating the corresponding host name for future maintenance.

Wiring is the core step in KVM switch deployment. Correct wiring directly affects equipment function and stability and must be performed strictly according to specifications. This chapter details wiring methods and precautions for different product types.

10.1 General Wiring Principles

  • Power-Off Wiring: All wiring operations must be performed with both the KVM switch and managed hosts powered off. Hot-plugging PS/2 interfaces is strictly prohibited. Although USB interfaces support hot-plugging, power-off wiring is still recommended to avoid static shock.
  • Interface Correspondence: Strictly follow interface labels. Video interfaces and keyboard/mouse interfaces must correspond one-to-one. The video cable and keyboard/mouse cable of the same host must be connected to the same numbered input port on the KVM to avoid signal misalignment.
  • Cable Selection: Use compliant dedicated cables with appropriate lengths. Avoid excess length causing signal attenuation. Cables must be intact without damage or oxidation. Connector pins must be straight without bending or breakage.
  • Insertion Standards: Align connectors correctly when inserting cables and insert smoothly. Avoid angled insertion that may bend pins. After full insertion, confirm latches engage securely with no looseness.
  • Clear Labeling: After wiring is complete, attach labels to both ends of each cable indicating the corresponding port and device for future maintenance and troubleshooting.
  • Cabling Standards: Separate high-voltage and low-voltage cables. Route low-voltage cables such as video and USB cables separately from power cables, avoiding parallel runs and twists to reduce electromagnetic interference. Organize cables neatly with cable ties to prevent pulling stress.

10.2 Standard Analog KVM Switch Wiring

Analog KVM is the most basic wiring method, divided into console-side wiring and managed-side wiring. The following uses a VGA+USB KVM as an example.

10.2.1 Console-Side Wiring (Console End)

The console side connects the user’s keyboard, mouse, and monitor. Steps:

1. Video Output Wiring: Insert one end of the VGA video cable into the KVM’s VGA output interface labeled “Console,” “Output,” or “Monitor” (monitor), and the other end into the monitor’s VGA input interface. Tighten the fixing screws on both sides of the connector.

2. Keyboard Wiring: Insert the USB connector of the USB keyboard into the KVM console USB interface labeled “Keyboard” or “KB.” Be careful not to insert into the mouse interface.

3. Mouse Wiring: Insert the USB connector of the USB mouse into the KVM console USB interface labeled “Mouse” or “MS.”

4. Audio Wiring (Optional): For models with audio functionality, insert the speaker audio cable into the audio output interface and the microphone into the microphone interface.

5. Monitor Power-On: Connect the monitor power cable, turn on the monitor, and wait for subsequent testing.

10.2.2 Managed-Side Wiring (PC/Server End)

The managed side connects multiple hosts, with each host corresponding to a set of input ports. Steps:

1. First Host Wiring: Select the PC1 port. Using a dedicated KVM connection cable, insert the video end into the host’s VGA output interface and the USB end into the host’s USB interface. Insert the other end into the KVM’s No. 1 VGA input and USB input ports respectively, ensuring interface numbers match.

2. Remaining Host Wiring: Using the same method, connect the 2nd, 3rd… Nth hosts to the KVM’s corresponding 2, 3… N input ports. Each host corresponds to a unique numbered port.

3. Audio Wiring (Optional): For models with audio functionality, connect to each host’s audio output and microphone input interfaces accordingly.

4. Host Power-On: After confirming all connections are secure, power on all managed hosts but do not turn on host power yet.

10.2.3 Power Wiring

1. Confirm the KVM power switch is in the OFF position.

2. Connect the power adapter or power cable to the KVM’s power interface, and the other end to a properly grounded power outlet.

3. After confirming correct wiring, turn on the KVM power switch. Observe the power indicator lights up and the device starts.

10.3 Wiring Key Points for Different KVM Interface Types

10.3.1 HDMI KVM Wiring

  • Use standard HDMI 2.0 cables to ensure sufficient bandwidth. Avoid inferior cables that may cause abnormal 4K signal transmission.
  • The interface is HDMI Type-A. Pay attention to orientation when inserting. HDMI interfaces are directional; do not force reverse insertion to avoid damaging connector pins.
  • HDMI interfaces have built-in friction retention. Insert fully without the need for screw fixation. Avoid pulling cables that may loosen the connection.
  • For HDCP-supported devices, confirm the KVM and cables support the corresponding HDCP version. Otherwise, black screens or copyright protection messages may occur.

10.3.2 DP KVM Wiring

  • Use standard DP cables and confirm version matching. High-resolution, high-refresh-rate scenarios require certified DP 1.4 cables.
  • DP interfaces have a latch. Insert until a “click” sound confirms engagement. To remove, press the latch before pulling out. Never pull forcibly on the cable.
  • Mini DP interfaces require adapters or dedicated cables. Ensure adapter quality is certified to avoid signal loss.

10.3.3 PS/2 Interface KVM Wiring

  • PS/2 interfaces are round 6-pin connectors. Purple is for keyboard, green for mouse. Strictly follow color correspondence. Mixed insertion will cause keyboard/mouse failure.
  • PS/2 interfaces do not support hot-plugging. Insert only when both the host and KVM are powered off. Otherwise, the motherboard interface may be burned out.
  • Align the pin notch when inserting and insert smoothly to avoid bending or breaking pins.

10.4 Digital Network Cable KVM Wiring

Digital network cable KVMs use Cat5/Cat6 network cables for signal transmission, providing more convenient cabling and longer transmission distances. Wiring steps:

1. Transmitter-End Wiring: Position the KVM transmitter module (or network interface) close to the managed host. Connect the host using short VGA/HDMI cables and USB cables. Connect the transmitter module’s RJ45 network port to the KVM host unit via network cable.

2. Host-End Wiring: Connect the other end of the network cable to the corresponding RJ45 input port on the KVM host unit. Network cable connectors must be terminated according to the T568B standard with correct wire order. Shielded network cables require proper grounding.

3. Console-End Wiring: Connect the console monitor, keyboard, and mouse directly to the KVM host unit’s console interfaces, following the same method as analog KVM.

4. Distance Requirements: Cat5e network cable transmission distance does not exceed 50 meters; Cat6 cable does not exceed 100 meters. For longer distances, add repeaters or use fiber optic transmission.

5. Cabling Notes: Route network cables away from high-voltage lines and interference sources. The cable bend radius must not be less than 8 times the cable diameter. Avoid crushing and kinking.

10.5 IP KVM Switch Wiring

In addition to local KVM wiring, the IP KVM also needs to be connected to the network to support remote access. The wiring steps are as follows:

10.5.1 Local Console Connection

Same as analog KVM: connect local keyboard, mouse, and monitor for local debugging and maintenance operations.

10.5.2 Controlled Host Connection

Connect all controlled hosts to the corresponding input ports of the KVM, using the same method as for analog KVM. Ensure that the video, keyboard, and mouse interfaces of each host are correctly matched to their respective ports.

10.5.3 Network Connection

LAN Access: Use a Gigabit Ethernet cable to connect the LAN port of the IP KVM to the LAN switch. It is recommended to connect to a dedicated O&M (Operations and Maintenance) network, isolated from the business network, to ensure security and bandwidth.

IP Address Planning: Plan IP addresses, subnet masks, gateways, DNS, and other network parameters in advance to ensure no IP conflicts and network reachability.

Cascade/Stacking Connection: When managing multiple IP KVM units centrally, connect all devices to the same management network and manage them uniformly through a centralized management platform.

Serial Port Connection (Optional): If serial ports of network devices need to be managed, use serial cables to connect the IP KVM’s serial port to the Console port of the target device.

PDU Connection (Optional): For remote power control, connect the intelligent PDU via serial port or network to enable remote power on/off.

10.5.4 Power Connection

IP KVM devices are typically configured with dual power supplies. Connect them to two independent power supply circuits respectively to achieve power redundancy, ensuring uninterrupted operation even if one power circuit fails.

10.6 Cascade Wiring

When the number of ports on a single KVM is insufficient, ports can be expanded through cascading. The wiring method is as follows:

Cascade Planning: Determine the master KVM and slave KVM. The master KVM is the device directly connected to the console, and the slave KVM is connected to one port of the master KVM.

Slave KVM Console Connection: Use a dedicated KVM connection cable. Connect one end to the console output interface (video + keyboard/mouse) of the slave KVM, and the other end to an idle input port of the master KVM with the corresponding port number.

Slave KVM Controlled-end Connection: Connect all controlled hosts to the various input ports of the slave KVM.

Power Connection: The slave KVM should be connected to a separate power supply for independent power.

Multi-level Cascade: For multi-level cascading, follow the same method: connect the next level to a port of the previous level. It is recommended not to exceed 3 cascade levels to avoid complex operations and signal attenuation.

10.7 Multi-Screen KVM Wiring

Dual-screen/multi-screen KVM supports synchronized switching of multiple monitors. Note the following during wiring:

  • Connect each host’s multiple video output interfaces to the corresponding multi-channel video inputs on the KVM port. For example, a dual-screen host’s HDMI1 connects to Port 1’s Channel A, and HDMI2 connects to Port 1’s Channel B.
  • Connect the console-side multiple monitors to the KVM console’s Channel A and Channel B video outputs respectively.
  • Ensure that the multi-channel sequence of each host is consistent with the console side to prevent screen misalignment.

10.8 Post-Wiring Inspection

After all wiring is completed, conduct a comprehensive inspection before powering on to avoid equipment faults caused by wiring errors:

Correspondence Check: Verify that each host’s video, keyboard, and mouse are connected to the same numbered port on the KVM, that the console interface types are correct, and there are no mixed connections.

Connection Firmness Check: Inspect all interfaces one by one, confirming they are fully inserted and secure, with no looseness or false contacts. Screws tightened, latches locked.

Cable Appearance Check: All cables have no damage, compression, or severe bending. Connector pins are straight and free from oxidation.

Power Check: Confirm that the supply voltage matches the equipment rating, power wiring is correct, and grounding is good.

Label Check: Labels at both ends of all cables are clear, and the correspondence relationship is unambiguous.

Cabling Check: Cables are neatly organized, separated between strong current and weak current, with no tangling or pulling, and adequate slack reserved.

Only after inspection confirms no errors, power on and proceed to the next step of commissioning.

After equipment installation and wiring are completed, systematic commissioning is required to ensure all functions work properly and performance meets standards. This chapter is divided into three parts: basic commissioning, advanced function commissioning, and IP KVM dedicated commissioning.

11.1 Pre-Commissioning Preparation

  • Confirm that all equipment wiring is correct, with no loose or incorrect connections.
  • Prepare test keyboards, mice, and monitors, ensuring the peripherals function properly.
  • Prepare power-on permissions and test accounts for all controlled hosts.
  • Record device default parameters, such as default IP address, default account password, and default hotkeys.
  • Commissioning personnel should be familiar with the device operation instructions and understand basic troubleshooting methods.

11.2 Basic Function Commissioning

11.2.1 Power-On Startup Test

1. Turn on the monitor power first, then the KVM switch power, and observe the device startup status.

2. Normal startup indications: Power indicator LED is steady on, the buzzer emits a single “beep” confirmation tone, and the front panel Port 1 indicator LED lights up (Port 1 is selected by default).

3. Abnormal diagnostics: If the power LED does not light up, check the power wiring. If the buzzer does not sound and all indicator LEDs are off, power off and check the power supply and device internals. If an abnormal alarm tone sounds, power off and check wiring for short circuits.

11.2.2 Single-Port Function Test

First, test the basic functions of Port 1 to verify the core link is functioning:

1. Power on the first controlled host and wait for the system to start.

2. Observe whether the monitor displays the host screen correctly, confirming the picture is clear, with no color cast, flickering, or ghosting.

3. Operate the keyboard to test typing and shortcut keys, confirming keyboard input works normally with no delay, missed keys, or key jamming.

4. Operate the mouse to test movement, clicking, and scrolling, confirming smooth mouse response with no stuttering, drift, or failure.

5. Test keyboard Caps Lock and Num Lock indicator LEDs to confirm status synchronization is normal.

6. For models with audio functionality, play an audio file to confirm clear sound, no noise, and proper synchronization.

If abnormalities are found during single-port testing, prioritize checking that port’s wiring, cable, and host interface. Replace the cable or perform cross-testing with another host to locate the problem.

11.2.3 Switching Function Test

After single-port functionality is confirmed normal, test the switching functions of all ports:

Panel Button Switching: Press the front panel port buttons in sequence to switch to the corresponding ports. Observe whether the switching process is smooth, whether each port’s picture, keyboard, and mouse work correctly, and confirm the port indicator LEDs switch in synchronization.

Hotkey Switching Test: Use the default hotkey combinations (such as pressing Scroll Lock twice + number key, or Ctrl+Alt+number key) to test hotkey switching. Confirm responsive hotkey operation, accurate switching, and no conflicts.

Cyclic Switching Test: Use the hotkey’s previous/next switching function to cycle through all ports. Confirm every port can switch normally, with no skipping or stuttering.

Auto-Scan Test: Enable the auto-scan function, set the scan interval (e.g., 5 seconds), and observe the KVM automatically cycling through all ports. Confirm normal picture switching and correct scan order.

Switching Performance Check: Observe the black screen time during switching. It should be less than 1 second for analog KVM and less than 2 seconds for digital KVM. The picture should stabilize quickly after switching with no prolonged black screen or resolution errors.

Test all ports one by one to ensure video, keyboard/mouse, and switching functions on every port are normal, with no defective ports or stuttering.

11.3 OSD Menu and System Settings Commissioning

Rack-mount and higher models are equipped with the OSD menu. Menu function commissioning and parameter configuration are required:

11.3.1 OSD Menu Activation Test

Use the default hotkey (usually Scroll Lock twice + Space, or Ctrl+Alt+Space) to activate the OSD main menu. Confirm the menu displays correctly on screen with clear overlay.

Test the menu’s up/down/left/right navigation, confirm, and return operations to confirm smooth keyboard operation of the menu without stuttering.

11.3.2 Port Naming Configuration

1. Enter the port management menu and assign corresponding host names to each port, such as “Web Server 1,” “Database Server,” “Office PC,” etc.

2. After configuration, switch ports to confirm the port names displayed in the OSD correspond to the actual hosts, facilitating O&M identification.

3. Ports can be grouped and sorted according to business type to optimize management logic.

11.3.3 System Parameter Settings

Hotkey Settings: Customize switching hotkeys and OSD activation hotkeys according to user habits to avoid conflicts with business software hotkeys.

Buzzer Settings: Enable or disable switching confirmation tones based on scenario requirements. The buzzer can be turned off in quiet office environments.

Auto-Scan Settings: Configure the auto-scan port range, interval time, and scan mode.

EDID Settings: Configure EDID emulation mode. You can choose to read the monitor’s EDID and copy it to all ports, or use the built-in default EDID to ensure resolution adaptation for all hosts.

Language Settings: Select the menu display language. Default is Simplified Chinese.

11.3.4 User Permission Configuration

1. Enter the user management menu, modify the default administrator password, and set a strong password to ensure device security.

2. According to O&M personnel structure, add regular user accounts, assign accessible port permissions, and restrict access to unauthorized ports.

3. Test login with different accounts to verify permission controls are effective: regular users cannot access unauthorized ports and cannot modify system settings.

11.4 Cascade Function Commissioning

When cascade deployment exists, cascade commissioning is required:

1. Confirm both the master KVM and slave KVM start up normally and individual functions work correctly.

2. Switch the master KVM to the cascade port and confirm it can properly display the slave KVM’s screen and operate the slave KVM’s OSD menu.

3. Use the master KVM hotkey or menu to switch to each sub-port under the slave KVM, confirming all cascade ports can be switched to and operated normally.

4. Test the switching logic across cascade levels, confirming port numbers and names display correctly with no operational confusion.

5. Optimize cascade operation hotkeys by setting cascade switching shortcuts to improve operational efficiency.

11.5 IP KVM Dedicated Commissioning

IP KVM functions are complex and require dedicated commissioning of network, remote functions, and advanced features.

11.5.1 Network Parameter Configuration

Local Configuration: Configure IP address, subnet mask, gateway, and DNS server address through the KVM’s network settings menu on the local console, or through a serial port debugging tool. Ensure the IP address is in the same subnet as the LAN with no conflicts.

Network Connectivity Test: Ping the KVM’s IP address from a computer on the same subnet to confirm network connectivity, with 0% packet loss and normal latency.

Web Access Test: Open a browser, enter the KVM’s IP address, access the Web management interface, and log in using the default account and password. Confirm the management interface loads normally.

11.5.2 Remote Control Function Commissioning

1. In the Web interface on the remote computer, open the remote KVM view and start video preview. Confirm the remote picture displays normally, clearly, and smoothly.

2. Test remote keyboard and mouse operations, confirming timely response, no obvious delay, accurate key entry, and smooth mouse movement.

3. Test remote port switching by switching between different controlled hosts through the Web interface, confirming normal switching and remote access to all ports.

4. Test display effects and smoothness under different resolutions and picture quality modes. Adjust encoding parameters based on network bandwidth to balance picture quality and smoothness.

5. Test WAN access via port mapping or VPN to verify cross-network remote access functionality works normally.

11.5.3 Virtual Media Function Commissioning

1. Enter the virtual media function interface, select a local ISO image file or insert a local USB drive, and click Mount.

2. Switch to the corresponding controlled host, enter BIOS or the system, and confirm the host recognizes the virtual optical drive/virtual USB drive.

3. Test reading files from the virtual media to confirm normal read/write operation and stable speed.

4. Test unmounting the virtual media to confirm the host side properly removes the device without errors.

11.5.4 User and Permission Commissioning

1. Add multi-level user accounts in the Web management backend, assigning different roles and port permissions.

2. Test login with different accounts to verify permission control accuracy: regular users can only access authorized ports and cannot modify system configuration.

3. Configure password policies, login timeout, IP whitelist, and other security policies to enhance device security.

11.5.5 Log and Audit Commissioning

1. Perform a series of operations including login, switching, operation, and logout. Check the system log to confirm all operations are accurately recorded, including time, account, action, and result.

2. Test log filtering, searching, and export functions to confirm logs can be exported for backup.

3. Enable session recording features (if available), and test recording, playback, and download functions to confirm recordings are complete and clear.

11.5.6 Advanced Function Commissioning

Serial Port Management Commissioning: Test the remote serial port function by remotely logging into the Console port of switches and routers to confirm serial communication works properly.

PDU Integration Commissioning: Configure intelligent PDU parameters, test remote power on/off and restart functions to confirm integration works correctly.

SNMP Commissioning: Configure SNMP parameters and connect to the network management platform to confirm device status can be monitored.

Firmware Upgrade: Check the current firmware version. If a new version is available, perform the firmware upgrade according to specifications, then test all functions after the upgrade.

11.6 Stability Testing

After all function commissioning is complete, perform stability testing to verify long-term operational reliability:

Continuous Operation Test: Run the device continuously for 24 hours or more. During this period, periodically switch ports and operate each host to confirm no crashes, stuttering, functional abnormalities, or abnormal temperatures.

Frequent Switching Test: Continuously and rapidly switch ports more than 100 times. Confirm switching remains normal throughout, with no crashes, black screens, or port failures.

Hot-Plug Test: For USB interface models, test the hot-plug function by plugging and unplugging USB keyboards and mice while powered on. Confirm the device recognizes them properly without affecting other ports.

Power Failure Recovery Test: Simulate a power outage, then restore power. Confirm the device starts up automatically, configuration parameters are not lost, and functions operate normally.

11.7 Commissioning Wrap-Up

After commissioning is complete, perform the following wrap-up tasks:

  • Save all configuration parameters and export configuration files for backup.
  • Record device IP addresses, account passwords, port mapping tables, and other information to form O&M documentation.
  • Clean up the commissioning site, organize cables, secure them with ties, and maintain neat cabling.
  • Apply device labels and operating instructions for the convenience of future O&M personnel.

12.1 Installation and Usage Safety Precautions

Electrical Safety

  • The device must be reliably grounded, especially rack-mount equipment. Do not use without grounding to avoid electric shock risk and electrostatic damage.
  • The supply voltage must match the device’s rated voltage. Use the included power adapter or power cord. Do not use unqualified power supplies.
  • Do not open the device enclosure while powered on. There are no user-serviceable components inside. In case of failure, contact professional personnel or the manufacturer’s after-sales service.
  • During thunderstorm weather, it is recommended to disconnect the device from the power supply and network cables to avoid surge damage from lightning.
  • Do not allow liquid to splash onto the device. Do not use in humid environments to prevent short circuits and device burnout.

Physical Safety

  • Install the device securely. Tighten screws on rack-mount equipment to prevent falling and causing injury or equipment damage.
  • Operate LCD all-in-one models gently when pushing/pulling or opening/closing to avoid damaging rails, hinges, and screens from excessive force.
  • Do not place heavy pressure or impact on the device. Do not place heavy objects on top of the device.
  • Disconnect power before cleaning. Use a dry, soft cloth for wiping. Do not use corrosive cleaners such as alcohol or gasoline.

Interface Operation Safety

  • PS/2 interfaces are strictly prohibited from hot-plugging. Always disconnect power before plugging or unplugging to avoid burning out the host motherboard interface and KVM interface.
  • Hold the connector body when plugging or unplugging cables. Do not pull the cable itself to avoid bending connector pins and breaking internal wires.
  • Align video connectors correctly when plugging and unplugging. Do not force angled insertion to prevent pin breakage.
  • When plugging and unplugging fiber optic connectors, protect the end faces from dust contamination and impact. Replace dust caps when not in use.

12.2 Daily Usage Precautions

Operating Standards

  • Wait for the picture to stabilize after switching ports before performing operations. Avoid rapid, frequent switching that can cause abnormal system detection.
  • Try not to switch ports during host startup to avoid abnormal peripheral detection during boot.
  • Press hotkeys accurately and in the correct sequence to avoid accidental keystrokes causing incorrect commands.
  • Do not repeatedly and rapidly switch ports to test the device, as this may cause abnormal operation of the switching chip.

Peripheral Usage

  • It is recommended to use standard wired keyboards and mice. Some wireless keyboards and mice may have compatibility issues, such as inability to recognize hotkeys or disconnection after sleep mode.
  • For models with USB Hub functionality, do not connect high-power devices such as high-power portable hard drives or charging devices, to avoid insufficient power supply causing device abnormalities.
  • When connecting external storage devices such as USB drives, pay attention to virus protection to avoid cross-infection of multiple hosts through the KVM.

Environmental Maintenance

  • Keep the device operating environment clean and regularly remove dust to prevent dust from entering the device and affecting heat dissipation and circuits.
  • Do not block ventilation openings to ensure proper heat dissipation and prevent high temperatures from causing device crashes or shortened lifespan.
  • Regularly check the temperature and humidity in the equipment room to ensure they are within the device operating range.

12.3 Deployment and Cabling Precautions

Cable Selection

  • Must use compliant, qualified cables that meet standards. Do not use inferior or non-standard cables to avoid signal attenuation, interference, and poor picture quality.
  • Video cable lengths should not be excessive. VGA cables are recommended not to exceed 15 meters, HDMI copper cables not to exceed 10 meters. For longer distances, use extenders or fiber optic cables.
  • For digital KVM network cables, use Category 5e or higher shielded twisted pair cables. Terminate according to standard wiring sequences to avoid signal failures from incorrect pinouts.

Cabling Standards

  • Separate strong current and weak current cabling with at least 30 cm spacing. Avoid parallel routing. Cross at right angles where possible to reduce electromagnetic interference.
  • Cable bend radii must meet requirements. Avoid sharp bends and compression to prevent internal cable damage.
  • Reserve adequate slack at both ends of cables to avoid tension. Route cables in the cabinet along cable management racks and secure them neatly.
  • Label all cables at both ends with corresponding equipment and port information for easy maintenance.

Cascade and Expansion

  • It is recommended not to exceed 3 cascade levels. Excessive levels cause cumbersome switching, signal attenuation, and increased operation latency.
  • Use dedicated cascade cables with appropriate lengths to avoid signal loss.
  • Evaluate device load capacity before expanding ports to avoid unstable operation from over-specification cascading.

12.4 IP KVM Security Precautions

Network Security

  • Deploy the IP KVM on a dedicated O&M internal network. Do not directly expose it to the public internet. If external access is truly required, use VPN, firewall port mapping, and other methods with proper security policies.
  • Change default account passwords promptly, set strong passwords, and change passwords regularly. Do not use weak passwords.
  • Enable the IP whitelist function to allow access only from authorized IP addresses.
  • Enable HTTPS encrypted access. Disable unnecessary network services and ports to reduce the attack surface.

Permission Management

  • Strictly follow the principle of least privilege. Assign permissions according to O&M personnel responsibilities. Prohibit sharing of administrator accounts.
  • Regularly audit operation logs and investigate abnormal operations to detect violations promptly.
  • Delete accounts promptly when personnel leave and change permissions accordingly.

Data Security

  • Unmount virtual media promptly after use to avoid security risks from prolonged mounting.
  • Session recording files should be stored encrypted and archived regularly. Do not distribute them freely.
  • Obtain firmware upgrade packages from official channels, verify firmware integrity to avoid malicious program implantation.

12.5 Common Prohibited Actions

  • Do not disassemble or modify the device yourself. Doing so voids the warranty and may create safety hazards.
  • Do not plug or unplug internal cables or modules while the device is running.
  • Do not use the device with resolutions or refresh rates exceeding specifications to avoid damaging the video chip.
  • Do not run firmware or software with unknown compatibility on the device to avoid bricking the device.
  • Do not use the KVM switch for illegal purposes, such as unauthorized access to others’ computer systems.

13.1 Daily Maintenance Standards

Good daily maintenance can extend equipment service life and reduce the probability of failure. It is recommended to follow these standards.

13.1.1 Daily Inspection

Perform routine inspections of the equipment daily/weekly. Inspection items include:

  • Whether power indicator LEDs and operation indicator LEDs are in normal status
  • Whether each port’s indicator LEDs are consistent with actual port status
  • Whether the equipment surface temperature is normal, with no abnormal overheating
  • Whether there are abnormal noises or odors from the equipment
  • Whether cable connections are secure, with no looseness or detachment
  • Whether equipment room temperature and humidity are within normal range

Record any abnormalities found during inspection and troubleshoot promptly to prevent minor faults from becoming major problems.

13.1.2 Regular Cleaning

Perform equipment cleaning every 1-3 months, adjusting the cycle based on environmental dust levels:

External Cleaning: After disconnecting power, wipe the equipment enclosure, front panel, and interface areas with a dry soft cloth. For stubborn stains, use a slightly damp cloth, wipe dry, then reconnect power.

Interface Cleaning: Use a soft brush to gently sweep dust from interfaces, or use compressed air to blow out dust to prevent poor contact caused by dust accumulation.

Ventilation Opening Cleaning: Clean dust accumulation at cooling grilles to ensure smooth ventilation.

LCD Screen Cleaning: Use dedicated screen cleaning cloth and cleaner. Do not spray liquid directly to avoid liquid seeping into the device.

13.1.3 Cable Maintenance

  • Regularly inspect cable condition for damage, aging, or stretching. Replace promptly if problems are found.
  • Organize and secure loose cables to maintain neat cabling and avoid stress.
  • For interfaces that are plugged and unplugged regularly, periodically check pin condition for oxidation or bending and address promptly.

13.1.4 System Maintenance

  • Regularly back up device configuration files to avoid configuration loss.
  • Monitor manufacturer firmware updates and upgrade to stable versions promptly to optimize functions and compatibility.
  • Regularly clear IP KVM log files and recording files to free up storage space.
  • Regularly review user permissions and remove invalid accounts.

13.2 Scheduled Maintenance Plan

It is recommended to develop an equipment maintenance plan according to the following schedule:

Maintenance Item Frequency Maintenance Content
Appearance and status inspection Daily Indicator LEDs, temperature, noise, cable appearance
Function spot check Weekly Spot check port switching, keyboard/mouse/video functions on each port
External cleaning Monthly Dust removal from enclosure, interfaces, ventilation openings
Deep cleaning Quarterly Internal cabinet dust removal, cable organization
Configuration backup Monthly Export configuration files for backup storage
Firmware check Semi-annually Check firmware updates, evaluate upgrade necessity
Comprehensive function test Annually Full-port function testing, performance testing, security inspection
Grounding and power check Semi-annually Check grounding reliability, power voltage stability

13.3 Fault Classification and Repair Reporting Process

13.3.1 Fault Classification

Based on the degree of impact, equipment faults are classified into three levels:

Level 1 Fault (Critical): Equipment completely unusable, all ports fail, seriously impacting business operations. Examples: complete system crash, power supply failure, core chip damage.

Level 2 Fault (Major): Partial functions fail, some ports unusable, affecting part of the business. Examples: single port damage, hotkey malfunction, OSD abnormality, single power supply failure.

Level 3 Fault (Minor): Slight functional abnormalities that do not affect core usage. Examples: indicator LED not lighting, buzzer abnormality, minor function issues.

13.3.2 Repair Reporting Process

Fault Troubleshooting: After a fault occurs, first perform self-checks according to the troubleshooting methods in Chapter 14 of this manual. Rule out external causes such as wiring, peripherals, hosts, and operations. Confirm it is an equipment fault.

Information Collection: Record the fault symptoms, equipment model, serial number, firmware version, and troubleshooting steps already taken to help after-sales service quickly locate the problem.

Contact After-Sales: Call Guangzhou Lain Intelligent System Development Co., Ltd. technical support hotline at +86 13538869979, or service hotline at +86 13538869979. Explain the fault situation and the technical staff will provide remote guidance.

Remote Processing: Technical staff will provide guidance for troubleshooting through phone, remote assistance, and other methods. Most configuration and operation issues can be resolved remotely.

Return for Repair: If remote resolution is not possible, follow after-sales instructions to return the device to the factory for repair. Non-human-caused damage within the warranty period is repaired free of charge. Beyond the warranty period, reasonable cost fees apply.

Acceptance and Archiving: After repair is completed, test the equipment functions to confirm normal operation and archive the repair records.

13.4 Repair Precautions

Warranty Statement: The complete product carries a 3-year warranty, the LCD screen a 1-year warranty, and accessories a 1-year warranty. Within the warranty period, non-human-caused damage is repaired or replaced free of charge.

Exclusion of Liability: The following situations are not covered by the warranty:

  • Faults caused by human damage, impacts, drops, or water ingress
  • Faults caused by self-disassembly, modification, or non-official firmware upgrades
  • Damage caused by connecting unqualified power supplies or improper use
  • Damage caused by force majeure such as natural disasters or lightning strikes
  • Products beyond the warranty period

Repair Qualification: Non-professionals are prohibited from disassembling or repairing the device themselves. Internal high-voltage and precision components can cause personal injury and secondary equipment damage. All repairs must be performed by the manufacturer or authorized service providers.

Transportation Note: When returning equipment for repair, use the original packaging or equivalent cushioning packaging to avoid secondary damage during transport. Freight costs are borne according to the warranty policy.

13.5 Storage and Transportation Maintenance

13.5.1 Long-Term Storage

When the equipment is idle for long-term storage, the following requirements must be met:

Item Requirement
Storage environment Dry, ventilated, dust-free; temperature -20°C to 60°C; humidity 5% to 90% non-condensing
Packaging Use original packaging, sealed, placed on dry shelving; avoid stacking heavy items on top
Periodic power-on Power on once every 3 months, run for more than 2 hours, to expel moisture and prevent capacitor failure
Anti-static Store in an anti-static environment to avoid electrostatic damage to chips

13.5.2 Transportation and Handling

  • Handle with care during moving, avoiding impacts, drops, and inversion.
  • Use cushioning packaging during transport, with moisture-proof and shock-proof measures. Avoid rain and direct sunlight exposure.
  • Transport LCD devices with screen facing up to avoid screen compression.
  • Protect the mounting ears on rack-mount equipment during transport to avoid deformation.

14.1 Power and Startup Faults

Problem 1: Device shows no response after power-on; power LED does not light up; buzzer does not sound

Possible causes:

  • Power cord/power adapter not fully inserted, poor contact
  • Power outlet has no power, switch not turned on
  • Power adapter damaged, no output
  • Internal power module fault in the device
  • Internal fuse blown

Solutions:

1. Re-plug the power cord and power adapter, ensuring secure connection. Test with a different power outlet.

2. Confirm the device power switch is in the ON position. Check that the outlet is supplying power normally. Use a multimeter to measure voltage.

3. Replace with a power adapter of the same specifications to test whether the adapter is damaged.

4. If all the above are normal, it is likely an internal power supply fault. Contact the manufacturer’s after-sales service for repair.

Problem 2: Device indicator LEDs flash after power-on, and the buzzer sounds an abnormal alarm

Possible causes:

  • Power supply voltage unstable, below rated range
  • Internal short circuit, power supply protection triggered
  • Motherboard fault, abnormal startup

Solutions:

1. After powering off, check all interfaces for short circuits, bent pins causing short circuits, and remove foreign objects from interfaces.

2. Change to a stable power supply environment, connect to a UPS for testing.

3. Power off and restart the device. If the alarm persists, contact after-sales for repair.

14.2 Video Display Faults

Problem 3: Monitor is completely black; no picture at all

Possible causes:

  • Monitor not powered on or not turned on
  • Console-side video cable not fully inserted or cable damaged
  • The currently selected port’s host is not powered on, or is in sleep/shutdown state
  • Host graphics card fault, no video output
  • KVM port fault, video switching chip abnormal
  • Resolution/refresh rate exceeds KVM supported range

Solutions:

1. Check monitor power and power switch. Confirm the monitor is turned on normally. Connect the monitor directly to the host to test and rule out monitor faults.

2. Re-plug the console-side video cable. Replace the video cable for testing to confirm cable integrity.

3. Switch to other ports for testing. If other ports are normal, check whether the corresponding host is powered on and whether the graphics card output is normal.

4. If all ports show no picture, connect the host directly to the monitor to confirm the host output is normal, ruling out host problems.

5. Check the host resolution settings. Reduce the resolution and refresh rate to within the KVM’s supported range.

6. Restart the KVM device, restore factory settings for testing. If still ineffective, contact after-sales for repair.

Problem 4: Picture has color cast, missing colors, or abnormal colors

Possible causes:

  • Video cable pins bent or broken, poor contact
  • Interface oxidation or looseness, excessive contact resistance
  • Cable too long, severe signal attenuation
  • Severe electromagnetic interference in the environment
  • KVM video processing circuit fault

Solutions:

1. Check the connectors at both ends of the video cable for bent or oxidized pins. Re-plug and tighten. Replace the cable for testing.

2. Shorten cable length. Use high-quality shielded cables.

3. Keep away from interference sources such as high-current equipment and RF devices. Route cables away from interference paths.

4. Perform cross-testing to determine whether it is a KVM port problem or a cable/host problem. Contact after-sales for port faults.

Problem 5: Picture flickers, shimmers, has water ripples, or ghosting

Possible causes:

  • Poor video cable quality, inadequate shielding
  • Cable too long, signal attenuation
  • Electromagnetic interference from surroundings, such as high-current lines, motors, transformers
  • Poor grounding, common-mode interference
  • Host graphics card refresh rate mismatch
  • Excessive power supply ripple on the KVM

Solutions:

1. Replace with a high-shielding quality video cable and shorten cable length.

2. Check equipment grounding to ensure reliable grounding. Separate strong current and weak current cabling.

3. Adjust the host refresh rate to standard 60Hz to match monitor and KVM specifications.

4. Replace with a stable power supply, connect to a UPS to purify power.

5. Eliminate interference sources and add signal filters.

Problem 6: Black screen after switching ports, takes a long time to display the picture

Possible causes:

  • KVM has no EDID emulation function, host re-detects monitor
  • EDID configuration abnormal, host resolution re-adaptation
  • Host graphics card slow response
  • Digital KVM encoding/decoding latency

Solutions:

1. Enable the KVM’s EDID emulation function. Read the monitor’s EDID and fix it to all ports to avoid the host re-detecting.

2. Set all hosts’ resolution and refresh rate to the same specifications to reduce adaptation time.

3. Update host graphics card drivers to optimize detection speed.

4. This is a normal phenomenon for digital KVM. High-end models can optimize firmware to reduce switching latency.

Problem 7: Abnormal resolution display, blurry or distorted picture

Possible causes:

  • EDID information mismatch, host recognizes wrong resolution
  • Monitor’s native resolution does not match host output
  • Analog signal transmission attenuation, decreased clarity

Solutions:

1. Reconfigure the KVM’s EDID to use the monitor’s real EDID, ensuring the host identifies it correctly.

2. Manually set the correct resolution and refresh rate on the host.

3. Replace with a shorter, higher-quality video cable to improve signal quality.

14.3 Keyboard and Mouse Faults

Problem 8: Keyboard completely unresponsive, key presses ineffective

Possible causes:

  • Keyboard plugged into the wrong interface, plugged into mouse port
  • Keyboard cable loose, poor contact
  • Keyboard itself damaged
  • KVM keyboard/mouse chip fault
  • Host USB/PS2 interface fault, or system has disabled the peripheral
  • PS/2 interface burned out due to hot-plugging

Solutions:

1. Confirm the keyboard is plugged into the correct Keyboard interface. For USB, try a different USB port.

2. Re-plug the keyboard, replace with another keyboard for testing to rule out keyboard faults.

3. Connect the keyboard directly to the host to test, confirming the host interface and system are normal.

4. PS/2 interfaces must be unplugged/replugged after powering off. Hot-plugging may damage the interface.

5. Restart the KVM device and restore factory settings for testing.

6. If a single port’s keyboard fails, check that port. If all ports fail, contact after-sales for repair.

Problem 9: Mouse malfunction, drifting, stuttering, or buttons ineffective

Possible causes:

  • Mouse plugged into wrong interface, poor contact
  • Mouse itself faulty, or wireless mouse low battery
  • Mouse compatibility issues; some special gaming mice or multi-function mice are incompatible
  • KVM mouse emulation abnormality
  • Host system lag, or mouse driver abnormality

Solutions:

1. Confirm the mouse is plugged into the correct Mouse interface. Re-plug and test with a regular wired mouse.

2. Connect the mouse directly to the host to test, ruling out host and mouse issues.

3. Disable the mouse’s special drivers and macro definition software. Test with the system default driver.

4. Adjust the mouse emulation mode in the OSD menu. Switch the USB emulation protocol.

5. Restart the KVM and host to re-recognize the device.

Problem 10: Hotkey switching unresponsive, cannot switch ports using the keyboard

Possible causes:

  • Hotkey remembered incorrectly, wrong key sequence or combination
  • Keyboard does not support hotkeys, such as some wireless keyboards or special keyboards
  • Hotkey conflicts with system or software hotkeys, intercepted by the system
  • KVM hotkey function disabled, or hotkeys have been changed
  • KVM keyboard/mouse chip abnormal, cannot recognize hotkeys

Solutions:

1. Check the manual to confirm the correct hotkey combination. Common default hotkeys: press Scroll Lock twice, Ctrl+Alt+Shift, or double-press Num Lock.

2. Replace with a standard wired USB keyboard to test, ruling out keyboard compatibility issues.

3. Disable system and software global hotkeys to avoid conflicts, or modify the KVM hotkeys to a non-conflicting combination in the OSD.

4. Use the panel button to enter the OSD menu, check hotkey settings, and restore default hotkeys.

5. Restart the KVM device and restore factory settings for testing.

Problem 11: Keyboard and mouse malfunction after switching ports, requiring re-plugging

Possible causes:

  • KVM peripheral emulation function abnormal, host-side device disconnected
  • Host USB power management, USB ports turned off after sleep
  • Cable poor contact, momentary disconnection during switching

Solutions:

1. Enable the KVM’s always-on keyboard/mouse emulation function to ensure host-side devices remain continuously online.

2. Disable USB power saving settings in the host system to prevent automatic shutdown of USB device power.

3. Replace with quality cables and ensure secure interface connections.

4. Update KVM firmware to optimize peripheral emulation compatibility.

Problem 12: Keyboard typing produces missed or extra keys; mouse movement laggy

Possible causes:

  • Cable too long, USB signal attenuation
  • Electromagnetic interference, signal transmission errors
  • KVM chip processing delay
  • Host system overload

Solutions:

1. Shorten the USB cable length. Use amplified USB extension cables.

2. Avoid interference sources. Use shielded cables and ensure reliable equipment grounding.

3. Reduce host system load by closing unnecessary programs.

4. For IP KVM, reduce video quality to improve control response speed.

14.4 Switching Function Faults

Problem 13: Panel buttons cannot switch ports

Possible causes:

  • Button stuck, unable to spring back
  • Target port has no device connected, port is masked
  • Panel button ribbon cable loose
  • Button damaged, or main control circuit fault

Solutions:

1. Check whether foreign objects are stuck in the button. Press gently to confirm normal spring-back.

2. Confirm the target port has a device connected and powered on. Some models cannot switch to empty ports.

3. Enter the OSD menu to check whether the port is disabled. Enable the corresponding port.

4. If all buttons are ineffective, contact after-sales to inspect the button panel and motherboard.

Problem 14: Auto-scan function not working

Possible causes:

  • Auto-scan function not enabled
  • Scan interval set too long, mistakenly believed not working
  • Scan port range set to empty
  • Function fault

Solutions:

1. Enable the auto-scan function correctly according to the manual.

2. Enter the OSD menu and check the scan interval setting. Adjust to an appropriate time.

3. Set the scan port range and add ports that need to be scanned.

4. Restore factory settings and test again.

Problem 15: Cascade ports cannot switch normally

Possible causes:

  • Cascade wiring error, console side and input side reversed
  • Cascade cable damaged
  • Too many cascade levels, abnormal signal
  • Cascade hotkey settings error

Solutions:

1. Check the cascade wiring. The slave KVM’s console output should connect to the master KVM’s input port. Confirm correct wiring.

2. Replace the cascade cable to rule out cable faults.

3. Reduce the number of cascade levels. It is recommended not to exceed 3 levels.

4. Refer to the cascade operation instructions and use the correct cascade switching hotkeys.

14.5 IP KVM Specific Faults

Problem 16: Cannot access the Web management interface; cannot ping the IP address

Possible causes:

  • Network cable not fully inserted, port LED not lit
  • IP address setting error, not in same subnet as the computer
  • IP address conflict, occupied by another device
  • Firewall or security software blocking
  • Network switch port fault
  • KVM network port fault

Solutions:

1. Check the network cable connection, confirm the network port indicator LED is lit. Test with a different cable and switch port.

2. Use the local serial port or OSD menu to view the KVM’s current IP address to confirm the IP configuration is correct.

3. Disconnect the KVM network cable and ping the IP address to confirm whether an IP conflict exists. Change to an idle IP.

4. Disable the computer firewall and antivirus software for testing. Test access from another computer on the same subnet.

5. Restore network default settings and restart the KVM device.

6. If none of the above works, determine it is a network port hardware fault and contact after-sales.

Problem 17: Remote picture stutters, high latency, or unclear

Possible causes:

  • Insufficient network bandwidth, severe packet loss
  • Picture quality settings too high, exceeding network capacity
  • High network latency, cross-network access
  • Client computer insufficient performance, decoding stutter
  • KVM encoding parameters set unreasonably

Solutions:

1. Test network bandwidth and packet loss rate. Ensure Gigabit bandwidth on the LAN and sufficient bandwidth on the WAN.

2. Lower video quality, resolution, and frame rate in the settings to prioritize smoothness.

3. Optimize the network path, access from a nearby location, and use VPN to improve public network transmission stability.

4. Use a computer with better performance for access and close unnecessary background programs.

5. Enable H.265 encoding to reduce bandwidth consumption.

Problem 18: Virtual media mount fails, host cannot recognize it

Possible causes:

  • Virtual media function not licensed
  • ISO image file too large or unsupported format
  • USB drive partition format incompatible, such as GPT partitions or specially encrypted USB drives
  • Host USB port disabled, or system recognition delay
  • Network interruption, mount process interrupted

Solutions:

1. Confirm the device has the virtual media license activated. Check the license status.

2. Use standard ISO images. Keep file sizes within the supported range. Avoid corrupted images.

3. Use regular FAT32/NTFS format USB drives. Avoid encrypted or specially partitioned drives.

4. Restart the host and test recognition in BIOS to rule out system issues.

5. Ensure network stability. Do not disconnect the network during the mounting process.

Problem 19: Remote keyboard/mouse operations out of sync or high latency

Possible causes:

  • High network latency, packet loss
  • Improper mouse mode settings, such as mismatch between absolute coordinate and relative coordinate modes
  • Client browser compatibility issues
  • KVM firmware optimization insufficient

Solutions:

1. Optimize the network to reduce latency and packet loss.

2. Switch mouse modes in remote settings. Relative mode is suitable for Windows; absolute mode is suitable for BIOS.

3. Use mainstream browsers such as Chrome or Firefox, or dedicated client software.

4. Update the KVM to the latest firmware to optimize keyboard/mouse transmission efficiency.

14.6 Audio and USB Peripheral Faults

Problem 20: No audio output or audio noise/interference

Possible causes:

  • Audio cable inserted into wrong ports, input/output reversed
  • Volume turned off, or host muted
  • Poor contact in audio cable
  • Improper grounding causing electrical current noise
  • Audio chip failure

Solutions:

  • Check audio cable connections, insert into the corresponding audio input/output interfaces, and verify correctness.
  • Check volume settings on both the host and speakers, unmute, and increase volume.
  • Replace the audio cable for testing, and re-plug connectors.
  • Ensure reliable equipment grounding to eliminate electrical current noise.
  • After cross-testing to confirm a port fault, contact after-sales support.

Problem 21: USB sharing port cannot recognize USB drives or printers

Possible causes:

  • USB device power consumption is too high, insufficient power supply
  • USB device compatibility issues; special driver-based devices not supported
  • USB cable too long, causing signal attenuation
  • USB Hub function not enabled

Solutions:

  • Use low-power USB devices; for high-power portable hard drives, it is recommended to use an external power supply.
  • Standard storage devices and printers are supported; special industrial equipment and encrypted devices may not be compatible.
  • Shorten the USB cable, or use a powered USB extension cable.
  • Enable the USB sharing function in OSD and confirm the port configuration is correct.

Chapter 15 Product QA

Basic Knowledge

Q1: What is a KVM switch? What is its main function?

A: A KVM switch is the abbreviation for Keyboard, Video, and Mouse switch. Its core function is to control multiple computers, servers, and other devices using a single set of keyboard, monitor, and mouse, without physical cable plugging/unplugging. One-key switching between controlled targets saves peripheral costs, saves space, and improves management efficiency.

Q2: Do KVM switches require driver software installation?

A: Analog KVM and basic digital KVM switches are pure hardware designs, plug-and-play, requiring no driver software installation, and are compatible with all host systems with standard interfaces. IP KVM only requires access via a browser or dedicated client, with no driver installation required; some advanced functions require lightweight plugin installation.

Q3: Which operating systems do KVM switches support?

A: Support for all Windows series, Linux, Unix, Mac OS, domestic operating systems (UOS, Kylin, Deepin, etc.), DOS, BIOS systems, and all systems supporting standard USB/PS2 and video output. The underlying environment can also operate normally.

Q4: What do 2-port, 4-port, 8-port, and 16-port KVM switches mean?

A: The number represents how many controlled hosts can be connected to the KVM switch. A 2-port switch can manage 2 hosts, a 16-port switch can manage 16 hosts. The more ports, the more devices that can be managed.

Q5: Can VGA, HDMI, and DP interface KVM switches be mixed?

A: The input interface must match the host output interface. If the host uses HDMI, select a KVM with HDMI input. Different interfaces require KVM switches with corresponding interfaces, or choose a hybrid interface KVM. Adapters can also be used for conversion, but adapters may affect compatibility and image quality.

Selection and Procurement

Q6: How do I choose the right KVM switch for my needs?

A: Selection mainly considers four dimensions:

  • Port quantity: Select based on the number of hosts to be managed, with 10%-20% redundancy reserved for future expansion.
  • Interface type: Select based on the host’s video interface, prioritizing mainstream interfaces; for mixed old/new systems, choose hybrid interface models.
  • Application scenario: Desktop use — desktop type; data center — rack-mount type; remote management needs — IP type; high-density data centers — LCD all-in-one type.
  • Functional requirements: Determine whether advanced functions such as audio, USB sharing, remote access, and virtual media are needed, and select accordingly.

Q7: Can KVM switches be cascaded for expansion? What is the maximum number of levels?

A: Most rack-mount KVM switches support cascade expansion by connecting the next-level KVM into one port of the upper level. It is recommended that cascading not exceed 3 levels, as excessive levels cause complex operation, signal attenuation, and increased latency.

Q8: What is the difference between remote KVM and remote desktop software?

A: There are three core differences:

  • Bottom-level control: IP KVM supports BIOS-level control, even when the system crashes or the network card fails; remote desktop depends on the system and network and cannot be used if the system fails.
  • Independence: KVM is a hardware device that does not occupy host resources or depend on the host system; remote desktop is software that requires the host to run services.
  • Security: KVM provides physical isolation and hardware encryption with higher security; remote desktop is system-based and susceptible to viruses and vulnerabilities.

Q9: How do I choose the screen size for an LCD KVM all-in-one?

A: Common sizes are 17-inch, 19-inch, and 21.5-inch. The 17-inch model has a resolution of 1280×1024, suitable for basic operations and maintenance. The 19-inch model with 1280×1024 or 1440×900 resolution is the mainstream choice. The 21.5-inch model supports 1920×1080 full HD, suitable for HD operation and maintenance needs. Choose based on rack depth and usage habits.

Q10: Digital KVM uses network cable transmission — will there be latency and image quality loss?

A: Digital KVM has slight analog-to-digital conversion latency; high-end models have latency within 10ms, which is almost imperceptible to the human eye, and image quality can be lossless. In ordinary office and O&M scenarios, there is no perceptible difference. For scenarios with extreme latency requirements, analog KVM can be selected.

Installation and Usage

Q11: Is KVM switch installation complicated? Can an ordinary person install it?

A: Analog KVM installation is very simple — just connect the cables accordingly and power on. No professional knowledge is required; ordinary people can complete installation following the manual. IP KVM requires network parameter configuration, which can be completed by IT personnel with basic skills, and the manufacturer also provides remote guidance.

Q12: Can KVM switches support hot-plugging of devices?

A: USB-interface KVM supports hot-plugging of USB devices. Plugging/unplugging keyboards, mice, or hosts with power on will not damage the equipment, but it is recommended that connections be made with power off to reduce electrostatic risk. PS/2 interfaces absolutely prohibit hot-plugging — power must be disconnected before operation, otherwise the interface may be burned out.

Q13: When switching KVM, will the host think the keyboard/mouse has been unplugged?

A: Reputable KVM switches come with peripheral emulation functionality, simulating that the keyboard and mouse are always online. The host will not detect device disconnection, and there will be no re-recognition or driver installation during switching. Cheap non-branded KVM switches may omit this function, causing device disconnection during switching.

Q14: What does the auto-scan function do? How is it set up?

A: The auto-scan function automatically cycles through all ports, suitable for data center inspection and monitoring scenarios, allowing all device statuses to be viewed in turn without manual switching. It can be enabled via OSD menu or hotkeys, with adjustable scan interval time and scan port range.

Q15: Can one KVM connect to multiple sets of keyboards and monitors?

A: A regular single-console KVM can only connect to one set of keyboard, mouse, and monitor. Multi-console matrix KVM can connect to multiple sets, supporting multiple people operating different hosts simultaneously, suitable for multi-O&M personnel and multi-seat scenarios.

Fault Operations and Maintenance

Q16: What if all ports have no response after the KVM switch is powered on?

A: Troubleshoot according to the following steps:

  • Check the power connection and socket power supply, confirm the device is properly powered on.
  • Confirm the host and monitor are working properly; test with direct connection to rule out peripheral and host faults.
  • Restart the KVM device and restore factory settings.
  • Check cable connections, confirm video and keyboard/mouse are on the same port.
  • If none of the above works, contact the manufacturer’s after-sales service for testing.

Q17: Why does the screen go black when switching to a particular host, while other hosts are normal?

A: Most likely, it is a problem with that specific host or port:

  • Check whether the host is powered on, whether the graphics card output is normal, and test with direct monitor connection.
  • Check whether the cable for that port is damaged; replace the cable for testing.
  • Check whether the host resolution exceeds the KVM supported range; lower the resolution.
  • Connect that host to another known-good port to determine whether it is a port problem or a host problem.

Q18: Hotkey switching doesn’t respond — is the device broken?

A: In most cases, the device is not damaged. Troubleshoot as follows:

  • Confirm the hotkey combination is correct; different brands have different default hotkeys, consult the manual.
  • Try a standard wired keyboard; some wireless keyboards and special keyboards do not support hotkeys.
  • Check for conflicts with software hotkeys; modify the KVM hotkey or disable software hotkeys.
  • Restart the KVM device and restore default hotkey settings.

Q19: Why is the KVM image unclear or blurry?

A: Common causes:

  • Poor quality or overly long cables causing signal attenuation; replace with better quality short cables.
  • Resolution mismatch — the host output resolution is not the monitor’s native resolution.
  • Poor interface contact; re-plug the video cable.
  • Normal attenuation of analog signals over long distances; a signal amplifier can be added.

Q20: Can KVM devices be powered on continuously for long periods? Will they easily fail?

A: Reputable rack-mount KVM switches are designed for 7×24-hour continuous operation with industrial-grade components, and MTBF exceeding 100,000 hours. Long-term operation will not easily cause failure, and data center environments typically run them with power on year-round. Desktop models also support long-term operation, just pay attention to heat dissipation.

After-Sales and Warranty

Q21: How long is the KVM switch warranty?

A: All KVM switches from Guangzhou Lain Intelligent System Development Co., Ltd. come with a 3-year full-unit warranty, 1-year LCD screen warranty, and 1-year accessory warranty. During the warranty period, non-artificial damage is repaired or replaced free of charge, with lifetime technical support.

Q22: How do I get repairs if the equipment fails? Can on-site maintenance be arranged?

A: First, call the technical support hotline at +86 13538869979. Technical personnel will provide remote troubleshooting guidance, and most issues can be resolved remotely. For hardware repairs that are truly required, the equipment can be returned to the manufacturer for repair. On-site service can be requested for major city customers, subject to the after-sales policy.

Q23: Does the warranty remain valid if I disassemble and repair it myself?

A: No. Self-disassembly or modification of the equipment will void the warranty qualification, and may cause secondary damage and safety hazards. All repairs should be handled through official after-sales service.

Q24: Can I upgrade the firmware myself? What if the upgrade fails?

A: The manufacturer provides official firmware upgrade packages and instructions, and users can upgrade independently following the guidelines. Power interruption during the upgrade process may brick the device. It is recommended to confirm power stability before upgrading and strictly follow the steps. If upgrade failure occurs, contact after-sales for recovery guidance — no need to return the unit.

Q25: Can products be customized? For example, custom port quantity, special interfaces, custom functions?

A: Yes, customization services are supported. Port quantity, interface types, functional modules, structural appearance, etc., can be customized according to user requirements. Contact the sales hotline at +86 13538869979 for specific requirements.

Chapter 16 Product Acceptance

16.1 Acceptance Overview

Product acceptance is a critical step in the delivery of KVM switch projects. It is divided into three stages: arrival acceptance, installation and commissioning acceptance, and final completion acceptance. Through a standardized acceptance process, the product quantity, quality, functionality, and performance are confirmed to comply with contract requirements, ensuring project delivery quality.

Acceptance is based on: purchase contract, technical specification, product manual, relevant national standards, industry specifications, etc. The acceptance process requires joint participation of both parties. After acceptance passes, an acceptance report is signed as proof of project delivery.

16.2 Arrival Acceptance

Arrival acceptance is conducted after the equipment is delivered to the site, mainly verifying product quantity, appearance, packaging, and accessories to ensure the delivered products are consistent with the contract and free from transportation damage.

16.2.1 Acceptance Content

  • Packaging inspection: Check whether the outer packaging box is intact, without damage, water immersion, crushing, or drop marks; whether packaging labels are clear; and whether model and quantity match the shipping list.
  • Quantity verification: After opening the box, compare against the contract and packing list to verify the quantity, model, and specification of the main units, confirming consistency with the purchase contract.
  • Appearance inspection: Check the main unit for scratches, paint peeling, deformation, corrosion, interface damage, and other physical damage; check the LCD screen for cracks, leakage, or scratches.
  • Accessory verification: Compare against the packing list to verify power cords, adapters, installation accessories, manuals, certificates of conformity, warranty cards, and all standard accessories are complete.
  • Qualification document inspection: Verify that the product certificate of conformity, quality inspection report, qualification certificates, and authorization letters are complete and valid.
  • Nameplate verification: Check product nameplate information, including model, serial number, manufacturer, rated parameters, production date, etc., confirming consistency with the contract.

16.2.2 Acceptance Standards

  • Packaging intact, no obvious transportation damage
  • Product model, specification, and quantity completely consistent with the contract
  • Product appearance intact, no physical damage, no signs of use
  • Accessories and documents complete, no missing items
  • Product nameplate clear, information accurate, original factory new product

16.2.3 Exception Handling

  • For severely damaged outer packaging: take photos on-site for evidence, contact logistics and supplier to negotiate return or replacement.
  • For quantity or model discrepancies: raise objections on-site, and have the supplier supply additional units or exchange.
  • For appearance damage or missing accessories: record in documentation, and have the supplier supplement or replace.
  • For failed arrival acceptance: do not sign the arrival confirmation, and require the supplier to rectify within a specified period and undergo re-acceptance.

16.3 Installation and Commissioning Acceptance

After equipment installation and wiring are completed and commissioning is normal, installation and commissioning acceptance is conducted to verify that installation workmanship, wiring standards, and basic functions comply with requirements.

16.3.1 Installation Workmanship Acceptance

  • Installation location: Equipment installation position complies with design requirements, U-position accurate, level and secure, no loosening or tilting.
  • Fastening workmanship: Screws complete and tightened properly, mounting ears installed level, rails slide smoothly (LCD models).
  • Grounding workmanship: Reliable grounding, grounding cable connection standard-compliant, grounding resistance meets requirements.
  • Cabling workmanship: Cables arranged neatly, strong/weak current separated, binding standardized, no tangling or pulling, labeling clear and accurate.
  • Labeling standards: Equipment labels, port labels, and cable labels complete with accurate and clear content.

16.3.2 Basic Function Acceptance

  • Power-on startup: Equipment starts normally, indicator lights display correctly, no abnormal alarms.
  • Full-port display testing: Switch through all ports one by one; each port displays correctly, clear without color shift, flickering, or black screen.
  • Full-port keyboard/mouse testing: Keyboard and mouse operate normally on each port, no failure, key ghosting, or lag.
  • Switching method testing: Panel buttons, hotkeys, OSD menu, auto-scan, and all other switching methods work normally.
  • Audio function testing: For models with audio, each port outputs audio normally without noise.
  • USB sharing testing: For models with USB Hub, peripherals are recognized normally with stable read/write.

16.3.3 System Configuration Acceptance

  • Port naming: All ports named according to business needs, names accurate and easy to identify.
  • Parameter configuration: Hotkeys, buzzer, scan interval, and other parameters configured according to user requirements.
  • User permissions: User accounts created, permission assignment correct, passwords changed.
  • Configuration backup: Configuration files exported and backed up, documentation records complete.

16.4 Final Completion Acceptance

After all functions are commissioned and trial operation is stable, final completion acceptance is conducted to comprehensively verify equipment performance, advanced functions, stability, documentation, etc. This serves as the basis for final project delivery.

16.4.1 Performance Indicator Acceptance

  • Switching speed: Test port switching time; analog KVM switching time ≤1 second, digital KVM ≤2 seconds, complying with technical specification requirements.
  • Video quality: At the maximum supported resolution and refresh rate, the image is clear, without distortion or latency, meeting parameter standards.
  • Transmission distance: Digital/IP KVM maintains stable signal and normal image quality at the nominal transmission distance.
  • Concurrent performance: IP KVM and matrix KVM tested for maximum concurrent users, with simultaneous operation free of lag or conflict.

16.4.2 Advanced Function Acceptance (IP KVM/Matrix KVM)

  • Remote access function: Normal remote access via both LAN and WAN, smooth images, responsive operation.
  • BIOS-level control: Remote access to BIOS works normally, operation smooth, bottom-level control effective.
  • Virtual media function: ISO images and USB drives can be mounted normally, read/write stable, system installation testing normal.
  • Permission management function: Multi-level user permissions effective, unauthorized operations blocked, meeting security requirements.
  • Log audit function: Full operation logs recorded, searchable and exportable, session recording normal.
  • Serial/PDU integration: Serial management and power integration functions operate normally, meeting design requirements.
  • Matrix switching function: Any input-to-output cross-switching operates normally, no blocking or conflict.
  • Seat collaboration function: Image push, pull, roaming, and other collaboration functions operate normally, smooth and efficient.

16.4.3 Stability Acceptance

  • Continuous operation test: Equipment operates for 72 continuous hours without interruption; functions normal during the period, no crashes, restarts, or abnormal disconnections.
  • Stress test: Frequent port switching and multi-user concurrent operation; equipment operates stably without anomalies.
  • Power failure recovery test: Simulate power failure and restoration; equipment auto-starts, configuration is not lost, functions normal.
  • Compatibility test: All different types and systems of hosts adapt normally without compatibility issues.

16.4.4 Documentation Acceptance

At acceptance, the supplier must deliver complete technical documentation, including:

  • Product user manual, maintenance manual
  • Installation and commissioning report, test records
  • Equipment configuration table, port mapping table, network parameter table
  • Account and password list (sealed delivery)
  • Product certificate of conformity, quality inspection report, qualification certificates
  • Training records and training materials
  • After-sales O&M contact information and service commitments

16.4.5 Training Acceptance

The supplier must provide operational training for user O&M personnel, ensuring users master:

  • Basic equipment principles and architecture
  • Daily operation methods, switching, menu usage
  • Basic fault troubleshooting and daily maintenance
  • Advanced function operations (IP KVM, etc.)
  • Safety usage standards and precautions

Training is considered qualified when users can independently complete daily operations and basic troubleshooting after training.

16.5 Acceptance Process

  • Acceptance application: After the supplier completes installation, commissioning, and self-inspection, submit an acceptance application and acceptance materials to Party A.
  • Acceptance preparation: Party A organizes the acceptance team, prepares acceptance tools and test plans, and both parties confirm the acceptance time.
  • On-site acceptance: Test and verify each acceptance item one by one, record results, with joint participation of both parties.
  • Issue rectification: Non-conforming items found during acceptance are recorded in the acceptance issue list; the supplier rectifies within a specified period and re-acceptance is conducted after rectification.
  • Report signing: After all acceptance items pass, both parties sign the acceptance report with official seals, the project is formally delivered, and the warranty period begins.
  • Document archiving: All acceptance materials and technical documents are archived for subsequent O&M reference.

16.6 Acceptance Determination Standards

  • Qualified: All acceptance items meet requirements, no outstanding issues, sign the qualified acceptance report.
  • Basically qualified: Minor issues exist that do not affect core functionality; interim acceptance signed with rectification within a specified period, followed by re-inspection after rectification.
  • Unqualified: Serious functional defects, core indicators not meeting standards, quantity/model discrepancies, or other major issues; acceptance not approved, supplier must rectify and re-apply for acceptance.

Chapter 17 SEO Optimization System and Keyword Integration

I. Search Keyword Classification System

1. Core Primary Keywords

KVM switch, KVM switch installation, KVM switch wiring, KVM switch commissioning, rack-mount KVM switch, IP KVM switch, digital KVM switch

2. High-Conversion Long-Tail Keywords

How to install a KVM switch, how to wire a KVM switch, KVM switch usage tutorial, KVM switch installation steps, KVM switch commissioning methods, data center KVM switch installation, rack-mount KVM installation wiring, LCD KVM all-in-one installation manual, KVM switch common faults and solutions, KVM switch acceptance standards

3. Industry Traffic Keywords

Server KVM switch, data center KVM equipment, multi-computer switch, keyboard mouse monitor switch, KVM over IP, KVM console, distributed KVM seating, matrix KVM switch, industrial-grade KVM switch, HD KVM switch

4. Brand-Specific Keywords

Lain KVM switch, Guangdong Lain KVM, Lain smart data center KVM, LA series KVM switch, Lain IP KVM, Lain LCD KVM all-in-one

5. Drop-Down / Related Search Keywords

This keyword category originates from real user search terms in the search box drop-down recommendations and related searches at the bottom of search results pages on mainstream search engines, precisely matching user-initiated question-type, exploratory, and decision-type needs. These keywords feature clear search intent, high user precision, strong conversion potential, and moderate competition, serving as the core source of long-tail traffic. They cover the following six dimensions:

  • Selection/Question type: Which brand of KVM switch is good, how to choose a KVM switch, what is a KVM switch used for, difference between KVM switch and network switch, which KVM switch interface type is best, does KVM switch support 4K, maximum number of ports on a KVM switch
  • Operation/Usage type: How to switch a KVM switch, KVM switch connection methods, KVM switch hotkey guide, how to use a KVM switch, how to configure a KVM switch, KVM switch cascade method, how to enable KVM switch auto-scan
  • Price/Cost type: How much does a KVM switch cost, 8-port KVM switch price, 16-port KVM switch quotation, IP KVM switch price, LCD KVM all-in-one price, industrial-grade KVM switch quotation
  • Brand/Manufacturer type: KVM switch brand ranking, domestic KVM switch manufacturer ranking, well-known industrial-grade KVM switch brands, Guangdong KVM switch manufacturer, Guangzhou KVM switch supplier, KVM manufacturers supporting customization
  • Fault/Troubleshooting type: KVM switch black screen solution, KVM switch mouse not working solution, KVM switch color shift handling, KVM switch hotkey not responding, KVM switch not recognizing keyboard
  • Scenario/Solution type: Data center KVM cabling, server room KVM deployment solution, what KVM for industrial PCs, what switch for two computers sharing one monitor, command center seating KVM solution

II. SEO Optimization Tag System

This tag system is configured for full-dimension SEO optimization of this manual page, covering core weight nodes for search engine crawling, following the optimization logic of “core keywords front-loaded, long-tail keywords covered, brand keywords closing,” adapting to ranking rules of mainstream search engines such as Baidu, Sogou, and 360, comprehensively improving page keyword rankings and natural traffic acquisition capability while maintaining the document’s professionalism and readability.

1. Page Core Optimization Tags

(1)Title Tag

Tag content: KVM Switch Installation Wiring Commissioning Manual_Parameters_Fault Troubleshooting_Guangdong Lain Smart Data Center

Optimization notes:

  • Core keyword “KVM switch installation wiring commissioning manual” is front-loaded, occupying the highest weight position in the title, precisely matching core search needs of users looking for technical documentation.
  • Mid-section integrates high-conversion long-tail words such as “parameters” and “fault troubleshooting,” covering multi-dimensional search intent including product selection and O&M troubleshooting, expanding page keyword coverage.
  • Tail section integrates the brand word “Guangdong Lain Smart Data Center,” strengthening brand exposure, achieving traffic brand closure, and improving brand keyword ranking.
  • Total character count controlled within 30 Chinese characters, complying with mainstream search engine title display rules and avoiding truncation of trailing content that affects user click-through rate.

(2)Meta Keywords Tag

Tag content: KVM switch, KVM switch installation, KVM switch wiring, KVM switch commissioning, rack-mount KVM switch, IP KVM switch, KVM switch manual, KVM switch fault troubleshooting, Lain KVM

Optimization notes:

  • Core primary keywords, high-conversion long-tail keywords, and brand-specific keywords arranged in priority order, totaling 9 core words, avoiding algorithm penalties from keyword stuffing.
  • Covers five user decision stages: product awareness, installation deployment, commissioning O&M, fault troubleshooting, and brand selection, matching search needs of users at different levels, improving page topic relevance.
  • Uses English comma separation, complying with search engine standard recognition rules, no redundant or invalid words, all keywords highly matched with page content.

(3)Meta Description Tag

Tag content: Guangdong Lain Intelligent System Development Co., Ltd. provides a full version KVM switch installation wiring commissioning manual, covering product introduction, principles and parameters, installation steps, wiring standards, commissioning methods, fault troubleshooting, acceptance standards, and other full-process content, compatible with rack-mount, IP type, LCD all-in-one and all series of KVM equipment, with detailed QA and O&M guide.

Optimization notes:

  • First sentence integrates brand words and core keywords, quickly improving search engine relevance determination, clarifying the page publisher and core topic, establishing a professional and credible initial impression.
  • Mid-section lists the page’s core value points, covering user pain points such as installation, wiring, commissioning, and fault troubleshooting, precisely hitting user needs and stimulating click intent.
  • Tail section supplements the product compatibility scope, strengthening the comprehensiveness and professionalism of the page content, improving user expectations and click willingness.
  • Total length controlled at approximately 120 Chinese characters, complying with search engine summary display rules, smooth and natural wording without stiff keyword stuffing.

2. Body Heading Level Tag System

Body headings use H1-H3 three-level hierarchical structure with clear logic and layered weight distribution, complying with users’ reading habits from simple to complex, and facilitating search engines to quickly crawl page structure, identify core content modules, and improve structured data display probability.

(1)H1 Tag

Tag content: KVM Switch Installation Wiring Commissioning Manual

Optimization notes:

  • Single unique H1 tag on the page, highly consistent with page topic and Title core words, strengthening the core topic weight of the page, avoiding weight dispersion from multiple H1 tags.
  • Placed at the very top of the page body, complying with search engines’ top-down crawling sequence, transmitting the page’s core topic and positioning at the first opportunity.

(2)H2 Tags

This page sets up 17 H2 tags (corresponding to core titles of Chapters 1-17), comprehensively covering each module of the product lifecycle, achieving full-domain long-tail keyword coverage, specifically including:

Product Introduction, Product Composition, Product Classification, Product List, Product Working Principles, Product Technical Parameters, Product Functions and Features, Product Application Scenarios, Product Installation, Product Wiring, Product Commissioning, Product Precautions, Product Repair and Maintenance, Product Common Problems and Solutions, Product QA, Product Acceptance, SEO Optimization System and Keyword Integration

Optimization notes:

  • Each H2 tag corresponds to an independent content module, precisely matching a type of long-tail search need. For example, “Product Installation” matches the search intent of “how to install a KVM switch,” and “Common Problems and Solutions” matches the search intent of “KVM switch fault troubleshooting.”
  • Overall logic progresses clearly from product awareness, selection reference to practical use, O&M and after-sales, completely covering the full user decision path, complying with user reading and search behavior logic.
  • All H2 tags naturally integrate keywords without stiff stuffing, balancing user reading experience and search engine optimization.

(3)H3 Tags

All subdivided modules under secondary chapters use H3 tags, such as “Desktop KVM Switch Installation,” “Rack-Mount KVM Switch Installation,” “Power and Startup Faults,” and “IP KVM Specialized Commissioning,” further segmenting long-tail keywords, covering more precise sub-scenarios and specific problems, forming a complete keyword coverage matrix.

Optimization notes:

  • H3 tags focus on sub-scenarios and specific problems, precisely matching user long-tail questions, greatly improving the page’s long-tail traffic acquisition capability, filling gaps in high-competition word areas.
  • Heading levels strictly controlled within three levels, avoiding overly complex structures that disperse search engine weight, ensuring weight concentration of core tags.
  • All H3 tags are substantive content headings, no meaningless empty headings, ensuring every tag carries corresponding keyword and content value.

3. Image ALT Tag Optimization

All images on the page — product photos, installation diagrams, wiring topology diagrams, system architecture diagrams — must be configured with corresponding ALT tags to help search engines identify image content and obtain image search channel traffic. Specific optimization rules:

  • Core product image ALT tag format: Brand + Product Model + Product Name, e.g., “Lain 16-port rack-mount VGA KVM switch,” “Lain 19-inch LCD KVM all-in-one”
  • Installation diagram ALT tag format: Scenario + Action + Product, e.g., “KVM switch rack installation steps diagram,” “Desktop KVM switch wiring diagram”
  • Architecture/principle diagram ALT tag format: Product Type + Principle/Architecture Diagram, e.g., “IP KVM switch working principle architecture diagram,” “Matrix KVM system topology diagram”
  • Keyword stuffing prohibited; ALT tags concise and accurate, highly matched with image content, single image ALT tag not exceeding 20 Chinese characters; use of unrelated keywords in ALT tags to deceive traffic is prohibited.

III. Internal Link Optimization Tags (Anchor Text · Natural Integration)

Internal link anchor text follows the principles of “natural integration, relevant matching, even distribution,” naturally embedding anchor text in the corresponding context of the body text, pointing to corresponding in-site landing pages, achieving weight transfer between pages, improving site-wide inclusion rate, and guiding users to browse deeper, while avoiding stiff integration that disrupts user reading experience.

1. Anchor Text Integration Principles

  • Relevance principle: Anchor text content must be highly consistent with the target landing page topic; irrelevant anchor text jumps prohibited. For example, “KVM switch” should jump to the KVM full-series product list page, not unrelated data center supporting product pages.
  • Naturalness principle: Anchor text fully integrated into body sentences, complying with normal reading logic, no forced insertion, no damage to sentence fluency and professional rigor.
  • Even distribution principle: Anchor text evenly distributed in the body’s first paragraph, middle paragraphs, and closing paragraph, avoiding concentrated stuffing; the same anchor text appears no more than 3 times on a single page, avoiding over-optimization determination.
  • Diversity principle: Anchor text forms diverse, including core words, long-tail words, and related words, avoiding repeated single anchor text, improving optimization naturalness.

2. Core Anchor Text

Core anchor text corresponds to in-site core product landing pages, transferring core page weight, improving keyword rankings of core product pages. Specific configuration:

Anchor Text Content Target Landing Page Type Recommended Placement Location
KVM switch KVM full-series product list page 1 time each in: body first paragraph, product introduction chapter, document conclusion
Rack-mount KVM switch Rack-mount KVM product category page 1 time each in: product classification chapter, product installation chapter
IP KVM switch IP KVM product detail page 1 time each in: product classification chapter, IP KVM specialized commissioning chapter
LCD KVM all-in-one LCD KVM product detail page 1 time each in: product classification chapter, LCD installation chapter
Matrix KVM switch Matrix KVM product detail page 1 time each in: product classification chapter, seating application scenario chapter
Digital KVM switch Digital KVM product category page 1 time each in: product classification chapter, network cable wiring chapter

3. Long-Tail Anchor Text

Long-tail anchor text corresponds to in-site knowledge documents and solution case landing pages, precisely matching long-tail search needs, improving inclusion and rankings of content pages, while guiding users to obtain deeper information. Specific configuration:

Anchor Text Content Target Landing Page Type Recommended Placement Location
KVM switch installation steps Anchor point in this manual’s installation chapter / standalone installation tutorial page Beginning of product installation chapter
KVM switch wiring method Anchor point in this manual’s wiring chapter / standalone wiring tutorial page Beginning of product wiring chapter
KVM switch commissioning method Anchor point in this manual’s commissioning chapter Beginning of product commissioning chapter
KVM switch common faults Anchor point in this manual’s fault troubleshooting chapter Beginning of common problems chapter
KVM switch acceptance standards Anchor point in this manual’s acceptance chapter Beginning of product acceptance chapter
KVM switch working principle Anchor point in this manual’s principle chapter Beginning of product principle chapter

4. Related Anchor Text

Related anchor text corresponds to in-site related product and solution landing pages, expanding user demand boundaries, building a complete in-site conversion path, improving user dwell time and site-wide conversion rate. Specific configuration:

Anchor Text Content Target Landing Page Type Recommended Placement Location
Micro-module cold aisle Micro-module data center solution page Application scenario — data center computer room chapter
Server cabinet Server cabinet product detail page Product installation — rack-mount installation chapter
Data center precision air conditioner Precision air conditioner product list page Application scenario — data center scenario chapter
UPS uninterruptible power supply UPS power product detail page Precautions — electrical safety chapter
Shielded computer room construction Shielded computer room overall solution page Application scenario — government classified scenario chapter
Data center structured cabling Data center cabling solution page Product wiring — cabling standards chapter
Environment monitoring system Data center environment monitoring product page IP KVM O&M management chapter
Smart PDU power Smart PDU product detail page IP KVM power integration function chapter

5. Anchor Text Integration Precautions

  • Anchor text uniformly uses in-site absolute paths, avoiding crawl errors caused by relative paths; periodically check link validity, promptly fix dead links, avoiding dead links affecting page weight.
  • Anchor text color can be slightly differentiated from body text, but avoid being too glaring, balancing user experience and link recognition; hidden links fully identical to body text color prohibited.
  • Use of hidden text, white text on white background, ultra-small fonts, and other cheating internal link methods prohibited, avoiding triggering search engine penalty mechanisms.
  • When new related content and product solutions are published in-site, corresponding related anchor text can be added to this page in reverse, continuously optimizing the site-wide internal link structure, improving site-wide weight.

IV. Keyword Body Integration Distribution Standards

Keyword integration follows the principles of “user experience priority, natural integration as supplement, reasonable and compliant density,” reasonably laying out keywords while ensuring document professionalism and readability, improving search engine relevance determination, while resolutely avoiding over-optimization penalties from keyword stuffing.

1. Keyword Density Control

  • Core primary keyword “KVM switch” density controlled between 2%-3% across the full text, ensuring sufficient topic relevance without triggering algorithm cheating determination from excessive density.
  • Long-tail keywords and industry traffic keywords distributed as needed in corresponding chapters; the same long-tail word appears no more than 5 times within a single chapter, completely and naturally integrated into professional sentences without forced repetition.
  • Brand-specific keywords evenly distributed in the document opening, product introduction, after-sales repair, copyright statement, and other modules, appearing 5-8 times throughout the full text, strengthening the strong association between brand and product.

2. Position-Based Integration Standards

(1)Opening first paragraph

The core primary keyword must appear in the document opening preface within the first 100 characters, naturally integrated into product positioning and value description, allowing search engines to identify the page’s core topic at the first opportunity, quickly improving topic relevance scoring. Simultaneously integrate brand words, establishing strong brand-product association awareness.

(2)Heading hierarchy

All level-1, level-2, and level-3 headings naturally integrate corresponding level keywords. Core keywords appear in H1, long-tail keywords in H2 and H3, forming a top-down keyword weight transfer structure, helping search engines quickly sort out the page content framework, improving structured summary display probability.

(3)Body paragraphs

The first and last paragraphs of each independent chapter integrate that chapter’s topic keywords; middle paragraphs naturally intersperse based on professional context, with core related words appearing every 300-500 characters, avoiding large segments without keywords. All professional terms and product names use unified expressions, maintaining keyword consistency, improving topic concentration.

(4)Lists and tables

In product parameter tables, fault troubleshooting tables, packing list tables, acceptance standard tables, and other table content, table headers and core data items naturally integrate keywords, covering search engine crawling dimensions for table content, further improving long-tail keyword matching.

(5)Closing conclusion

In the document conclusion before the copyright statement, core keywords and brand words appear again, forming a structure with beginning and ending echo, strengthening page topic weight, while naturally guiding users to contact and inquire, completing the closed loop from traffic to conversion.

3. Keyword Variant Application

To cover more user search forms, the body text reasonably integrates different variant forms of keywords, expanding keyword coverage without affecting professionalism:

  • Abbreviation and full name combination: e.g., “KVM switch” with “keyboard video mouse switch” and “KVM switch unit”
  • Different expression methods: e.g., “installation” with “deployment” and “setup,” “commissioning” with “configuration,” “settings,” and “adjustment”
  • Colloquial and written combination: covering both written technical document searches and colloquial question searches
  • Natural presentation of different word orders: avoiding identical sentence patterns repeated, improving content naturalness, reducing algorithm stuffing determination probability.

4. Integration Prohibitions

  • Keyword stuffing prohibited: No continuous repetition of the same keyword within the same paragraph, no meaningless keyword lists, no forced insertion of irrelevant content to achieve density.
  • Stiff integration prohibited: No insertion of keywords that destroys sentence fluency and professional rigor, no illogical or awkward sentences.
  • Hidden keywords prohibited: No use of white text, ultra-small fonts, hidden layers, comment codes, or other methods to place user-invisible keywords.
  • Irrelevant keywords prohibited: No integration of hot keywords unrelated to this document’s topic to deceive traffic, avoiding page topic dispersion and weight reduction.

Copyright Statement

All content of this document (“KVM Switch Installation Wiring Commissioning Manual”), including but not limited to text expressions, data tables, product architectures, technical solutions, schematic diagrams, etc., is copyrighted by Guangdong Lain Intelligent System Development Co., Ltd., protected by the Copyright Law of the People’s Republic of China and related international copyright conventions.

No individual or organization may, without written official authorization from the company, reproduce, repost, adapt, excerpt, disseminate, mirror, create derivative works, or use commercially in any form, nor use this document’s content for product promotion, solution bidding, manual production, teaching/training, or any other commercial or non-commercial public purpose.

Any individual or organization authorized by the company to repost or quote this document’s content must prominently indicate the source at the content location: “Content source: Guangdong Lain Intelligent System Development Co., Ltd. official website gdlain.com,” and must not distort, alter, or abridge the original content, nor use it for commercial profit purposes.

Individuals or organizations violating the above copyright statement will be held legally accountable by the company to the full extent of the law, including immediate cessation of infringement, public apology, and compensation for corresponding economic losses and brand reputation damage.

This document is a general technical description document. Due to product iteration, technology upgrades, and standard updates, the company will revise content from time to time. Final product parameters, functions, and specifications are subject to the actual product. The company reserves the final interpretation and modification rights for this document.

Contact Us

Manufacturer: Guangdong Lain Intelligent System Development Co., Ltd.

Service Hotline: +86 13538869979 (WeChat same number)

Technical Support: +86 13538869979

Company Address: Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou

Official Website: gdlain.com

Shopping Cart