Document Number: LA-DG-ZJ-2026-V1.0
Version: V1.0
Prepared by: Guangdong Lain Smart Equipment Co., Ltd.
Date: July 2026
Table of Contents
TogglePreface


With the large-scale deployment of 5G communication technology and the deepening advancement of smart city construction, the base station construction model is rapidly evolving from traditional high-tower macro stations to distributed, miniaturized, and landscaped forms. As the core product embodying the concept of “one pole, multiple uses, resource sharing,” the light pole base station bracket leverages existing urban street light poles and smart light pole infrastructure to achieve rapid mounting and efficient deployment of communication base station equipment. It effectively resolves industry pain points such as difficult site selection, long approval cycles, high construction costs, and poor landscape coordination associated with traditional base station construction, and has become a core support solution for deep coverage of mobile communication networks and edge computing node deployment.
This manual is compiled in accordance with national and industry standards including the *General Technical Requirements and Test Methods for Pole (Tower) Equipment Mounting Brackets in Communication Stations* (YD/T 4868-2024), *Construction Technical Specifications for Multifunctional Intelligent Pole Systems* (DB4403/T 368—2023), *Communication Base Station Construction and Maintenance Specifications*, and other national and industry standards, combined with years of research, production, and engineering practice experience of Guangdong Lain Smart Equipment Co., Ltd. in base station support structures. It aims to provide standardized, normalized, and refined technical guidance for the entire process of installation, wiring, commissioning, and maintenance of light pole base station brackets, ensuring that product installation quality, electrical safety, communication performance, and structural service life meet design requirements, and guaranteeing stable and reliable communication network operation.
This manual covers 15 core chapters: Product Introduction, Product Composition, Product List, Working Principle, Technical Parameters, Functional Features, Application Scenarios, Installation Process, Wiring Specifications, Commissioning Procedures, Precautions, Maintenance and Repair, Troubleshooting, QA Q&A, and Acceptance Standards. The content covers the entire product lifecycle technical requirements and is applicable to light pole base station bracket engineering construction and operation/maintenance management in various scenarios including municipal roads, parks, scenic areas, and commercial districts. It may serve as a reference for construction units, construction contractors, supervision units, operation and maintenance units, and communication operator technical personnel.
Due to continuous technological iteration and differences in engineering scenarios, this manual will be continuously updated and improved. If there are any questions or technical requirements during use, please contact our technical support department promptly for professional guidance.
Chapter 1 Product Introduction


1.1 Product Definition
The light pole base station bracket is a type of base station equipment mounting support structure specifically designed for cylindrical/polygonal poles such as street light poles, smart light poles, and landscape light poles. It belongs to the category of communication base station auxiliary support equipment. The product is installed at a specified height on the light pole through clamp clamping, flange connection, or welding fixation methods, providing a stable installation platform for communication base station equipment including 5G AAU (Active Antenna Unit), RRU (Remote Radio Unit), antenna arrays, transmission equipment, and power modules. It is equipped with auxiliary structures for cabling, grounding, and lightning protection, achieving integrated integration of base station equipment and light pole carrier.
As the core connecting component for the integrated construction of “light pole + base station,” the light pole base station bracket is a key component for achieving shared construction of communication infrastructure and municipal lighting facilities. It enables rapid deployment of communication base station points without adding independent towers or damaging urban landscapes, significantly improving construction efficiency and reducing overall construction costs.
1.2 Product Development Background
Traditional communication base station construction relies on dedicated carriers such as independent communication towers and rooftop poles. As construction resources in core urban areas become increasingly saturated, traditional construction models face numerous challenges including difficult site selection, high rental costs, and complex construction coordination. Meanwhile, urban street light poles possess natural advantages including uniform distribution, dense point coverage, complete power supply support, and heights well-suited to communication coverage requirements, making them ideal carriers for 5G micro base stations and small cells.
Early light pole base stations mostly used simple welded brackets or ordinary clamp fixation, suffering from problems such as insufficient structural strength, poor corrosion resistance, non-standard installation, and inconvenient maintenance, which made it difficult to meet the requirements for long-term stable operation of communication equipment. Against this background, standardized, modularized, and highly reliable light pole base station bracket products emerged. Through professional structural design and industrialized production, safe, standardized, and efficient deployment of light pole base stations has been achieved.
1.3 Product Design Philosophy
The light pole base station brackets produced by our company follow the core design philosophy of “safe and reliable, universally adaptable, convenient installation, and landscape coordination”:
Safety First: Strictly designed according to communication industry structural load standards, meeting wind resistance, seismic resistance, and corrosion resistance requirements, ensuring structural safety under extreme environments and eliminating safety accidents such as overturning and detachment.
Universal Adaptability: Modular adjustable design adapts to light poles of different diameters and cross-section forms, compatible with AAU, RRU, and antenna equipment of various models from mainstream manufacturers, meeting the co-mounting deployment needs of multiple operators and multiple system standards.
Efficient Construction: Full bolted assembly structure, no on-site welding required, equipped with specialized installation tools, enabling fast installation by one or two persons, significantly shortening construction periods and reducing high-altitude operation risks.
Landscape Integration: Clean streamlined appearance design, surface treatment consistent with light pole color tones, strong overall coordination after installation, minimizing impact on urban landscapes.
Maintenance-Friendly: Ample operating space and maintenance interfaces reserved, equipped with cable management and grounding structures, facilitating future equipment expansion, inspection, repair, and upgrades.
1.4 Product Implementation Standards
This product’s design, production, inspection, and installation strictly comply with the following national and industry standards:
- YD/T 4868-2024 *General Technical Requirements and Test Methods for Pole (Tower) Equipment Mounting Brackets in Communication Stations*
- GB 50017-2017 *Standard for Design of Steel Structures*
- GB 50205-2020 *Standard for Quality Acceptance of Steel Structure Engineering Construction*
- GB/T 13912-2002 *Metallic Coatings — Hot Dip Galvanized Coatings on Fabricated Iron and Steel Articles — Specifications and Test Methods*
- GB 50057-2010 *Code for Design Protection of Structures Against Lightning*
- GB 50173-2014 *Code for Construction and Acceptance of 66kV and Below Overhead Power Transmission Line*
- DB4403/T 30—2019 *Specifications for Design and Engineering Construction of Multifunctional Intelligent Pole Systems*
- DB4403/T 368—2023 *Construction Technical Specifications for Multifunctional Intelligent Pole Systems*
- T/SPIA 001—2020 *Construction Specifications for Smart Poles*
1.5 Product Applicable Scope
This product is applicable to various municipal street light poles, smart multifunctional poles, landscape light poles, and park lighting poles with heights of 6m to 15m. It can mount 5G/4G macro and micro base station antennas, AAU, RRU, repeaters, WLAN APs, IoT gateways, and other communication equipment. It is widely used in communication base station construction in various scenarios including urban main roads, secondary roads, back streets and alleys, commercial districts, industrial parks, residential communities, tourist attractions, campuses, and hospitals.
Chapter 2 Product Composition


The light pole base station bracket adopts a modular split design. The complete system consists of six functional units: main support structure, equipment mounting structure, fastening and connection structure, cable management structure, lightning protection and grounding structure, and auxiliary components. Each unit operates independently while coordinating with others to form a complete base station support system.
2.1 Main Support Structure
The main support structure is the load-bearing core of the entire bracket system, bearing all loads from base station equipment and transferring loads evenly to the light pole body. It mainly includes the following components:
Main Crossbeam: The primary load-bearing member of the bracket, made of high-strength steel or aluminum alloy profiles, extending laterally outward from the light pole, providing the installation reference surface for base station equipment. The crossbeam cross-section is designed as rectangular tube, channel steel, or I-beam forms according to load class, with anti-corrosion surface treatment and excellent bending and torsional resistance.
Main Vertical Beam: A vertical load-bearing member arranged parallel to the light pole axis, closely fitted to the light pole through clamps, distributing loads transferred from the crossbeam to multiple clamp nodes to reduce local stress on the light pole. The main vertical beam length is customized according to the number and spacing of mounted equipment, with continuous adjustment holes on the surface for flexible adjustment of crossbeam installation height.
Diagonal Brace: A diagonal support member connecting the outer end of the main crossbeam to the lower portion of the main vertical beam, forming a triangular stable load-bearing structure that significantly enhances the overall stiffness and wind load resistance of the bracket, reducing equipment swing amplitude under strong winds. Both ends of the diagonal brace use hinged or bolted connections for convenient transportation and on-site assembly.
Reinforcing Rib Plates: Reinforcement members installed at stress concentration areas such as crossbeam-to-vertical-beam connection nodes and clamp connection nodes, cut and formed from steel plates, fixed by welding or bolts to effectively enhance node strength and prevent deformation under load.
2.2 Equipment Mounting Structure
The equipment mounting structure is used to achieve reliable connection between base station equipment and the bracket main body, ensuring that equipment mounting position and angle meet communication coverage design requirements. It mainly includes:
Equipment Mounting Backplate: A flat plate component directly connected to base station equipment, with standard mounting holes on the surface, compatible with mainstream AAU and RRU equipment mounting hole spacing. The backplate is fixed to the main crossbeam with bolts and can be adjusted laterally along the crossbeam to meet multi-equipment side-by-side installation requirements.
Angle Adjustment Mechanism: Composed of a pivot shaft, arc-shaped adjustment slots, and fastening bolts, enabling continuous adjustment of antenna equipment tilt angle from 0° to 15°. Some models support fine adjustment of horizontal azimuth angle for on-site optimization of signal coverage.
Equipment Limit Stop Block: A limit component installed at the bottom of the backplate that supports the bottom weight of the equipment, preventing equipment from sliding down when bolts loosen, enhancing installation safety.
Equipment Vibration Isolation Pad: A rubber or silicone buffer pad installed between equipment and backplate, cushioning vibrations from wind-induced oscillations, reducing fatigue wear on equipment connection components, and providing a certain degree of insulation isolation.
2.3 Fastening and Connection Structure
The fastening and connection structure achieves secure connection between the bracket and the light pole, serving as a critical component ensuring overall bracket stability. It mainly includes:
Main Clamp: A ring-shaped fastening component encircling the light pole, consisting of two half-arc clamp plates tightened with high-strength bolts to secure the entire bracket at the designated position on the light pole. The clamp inner diameter can be adjusted with shims to adapt to different light pole diameters. The inner arc surface features anti-slip teeth or anti-slip rubber pads to increase friction and prevent bracket sliding and rotation.
Secondary Clamp: An auxiliary fastening component arranged above and below the main clamp, connected to the main vertical beam, further increasing connection points, distributing loads, and enhancing overall torsional resistance.
High-Strength Bolt Assembly: Includes bolts, nuts, flat washers, and spring washers, all made of stainless steel or hot-dip galvanized with anti-corrosion treatment, grade not lower than 8.8, used for clamp tightening and all component connection fastening points.
Anti-Loosening Lock Washers: Installed under nuts at critical fastening nodes, using serrated or snap-in structures to prevent bolt loosening caused by long-term wind vibration, enhancing long-term structural reliability.
2.4 Cable Management Structure
The cable management structure is used to regulate the routing paths of various cables including base station feeders, power cables, and transmission cables, protecting cables from external force damage while improving overall tidiness. It mainly includes:
Cable Tray/Cable Ladder: U-shaped or enclosed cable channels arranged along the main vertical beam, providing centralized routing passages for cables and preventing cable wear from wind-induced swinging.
Cable Fixing Clamps: Plastic or metal cable retention components fixed at intervals on cable trays or vertical beams to bundle and secure cable harnesses, with spacing conforming to communication engineering cable routing specifications.
Feeder Window/Cable Pass-Through Hole: Cable routing structures installed near the equipment mounting area that guide cables from inside the pole or cable tray to equipment interfaces, avoiding excessive cable bend radius.
Cable Waterproof Gland: Also known as a cable gland, installed at equipment chassis cable entry points and pole pass-through holes, combined with waterproof rubber gaskets to achieve sealed waterproofing at cable entry points, preventing rainwater from seeping in along cables.
2.5 Lightning Protection and Grounding Structure
The lightning protection and grounding structure is used to rapidly conduct lightning current from the bracket and equipment into the ground, protecting base station equipment from lightning damage. It mainly includes:
Grounding Terminal Block: A copper grounding busbar fixed to the lower portion of the bracket with multiple wiring holes for collecting equipment grounding wires and bracket grounding wires.
Grounding Down Conductor: Stranded copper core cable connecting the grounding terminal block to the light pole grounding system, with cross-sectional area meeting lightning protection specification requirements, ensuring smooth lightning current discharge path.
Equipotential Bonding Strip: Used for electrical continuity between various metal components of the bracket and between the bracket and the light pole, eliminating potential differences and preventing back-surge voltages during lightning strikes.
Lightning Rod Fixing Clamp: If a lightning rod is installed at the bracket top, the accompanying fixing clamp ensures the lightning down conductor is properly routed along the pole body.
2.6 Auxiliary Components
Maintenance Platform/Step: Some high-load, high-mounting-height bracket models are equipped with small steps or maintenance platforms, providing working footholds for on-site installation and later maintenance, reducing the difficulty of high-altitude operations.
Identification Plates: Include equipment identification, warning signs, and ownership identification plates, fixed at conspicuous positions on the bracket for operation/maintenance identification and safety warnings.
Corrosion Repair Kit: Includes color-matched touch-up paint pens, zinc spray, sealant, etc., used for repairing damaged anti-corrosion coating during on-site installation.
Specialized Installation Tools: Matching torque wrenches, hex wrenches, spirit levels, and other specialized tools to ensure installation process compliance.
Chapter 3 Product List
3.1 Standard Configuration List
Using the Lain LA-DG-600 universal light pole base station bracket (single equipment position, compatible with φ114~φ165mm light poles) as an example, the standard packaging configuration is shown in the following table:
| No. | Component Name | Specification/Model | Unit | Qty | Material/Surface Treatment | Remarks |
|---|---|---|---|---|---|---|
| 1 | Main Crossbeam | 600mm | pcs | 1 | Q355 steel / Hot-dip galvanized + powder coating | Main load-bearing beam for equipment mounting |
| 2 | Main Vertical Beam | 800mm | pcs | 1 | Q355 steel / Hot-dip galvanized + powder coating | Main load-bearing beam for pole connection |
| 3 | Diagonal Brace | Custom length | pcs | 1 | Q355 steel / Hot-dip galvanized + powder coating | Triangular stability support |
| 4 | Upper Main Clamp | Suitable for φ114~φ165mm | set | 1 | Q355 steel / Hot-dip galvanized | Includes anti-slip rubber pad |
| 5 | Lower Secondary Clamp | Suitable for φ114~φ165mm | set | 1 | Q355 steel / Hot-dip galvanized | Auxiliary fixation |
| 6 | Equipment Mounting Backplate | 400×300mm | pcs | 1 | Aluminum alloy / Anodized | With tilt angle adjustment function |
| 7 | Cable Tray | 800×50×30mm | pcs | 1 | PVC/Galvanized steel plate | U-shaped cable channel |
| 8 | Grounding Terminal Block | 3-hole copper busbar | pcs | 1 | T2 copper / Tin-plated | M8 wiring holes |
| 9 | High-Strength Bolt Assembly (for clamps) | M16×80mm | set | 4 | 304 stainless steel | Includes nuts, flat washers, spring washers |
| 10 | Structural Connection Bolt Assembly | M12×50mm | set | 8 | 304 stainless steel | Includes nuts, flat washers, spring washers |
| 11 | Equipment Fixing Bolt Assembly | M10×30mm | set | 4 | 304 stainless steel | Includes nuts, flat washers, vibration pads |
| 12 | Cable Clamps | 20mm | pcs | 6 | Nylon/Stainless steel | For cable fixing |
| 13 | Waterproof Cable Gland | PG13.5 | pcs | 2 | Nylon/Brass nickel-plated | Cable pass-through waterproofing |
| 14 | Equipotential Bonding Strip | 20×2mm copper strip | pcs | 1 | T2 copper | Bracket-to-pole cross bonding |
| 15 | Product Certificate | — | sheet | 1 | — | Factory inspection conformity certificate |
| 16 | Installation Manual | — | copy | 1 | — | This manual |
| 17 | Specialized Tool Kit | — | set | 1 | — | Includes wrenches, spirit level, hex keys |
3.2 Optional Accessory List
The following expansion accessories may be optionally configured according to actual engineering requirements:
- Multi-Equipment Expansion Kit: Extends crossbeam length and adds mounting backplates to enable side-by-side installation of 2–4 devices, meeting multi-operator co-mounting requirements.
- Large-Diameter Clamp Adaptation Kit: Suitable for φ180mm~φ325mm large-diameter light poles, including extended bolts and inner diameter adjustment shims.
- Square Light Pole Adaptation Kit: Flat clamps and anti-slip liners designed for square and polygonal cross-section light poles.
- Lightning Rod Kit: Includes small air-termination rod, down conductor, and fixing clamps, suitable for high lightning activity areas.
- Equipment Cabinet Mounting Tray: Tray structure for installing box-type equipment such as power modules and transmission switches.
- Maintenance Step Kit: Foldable step platform providing working support for high-altitude installation and maintenance.
- Anti-Theft Bolt Kit: Uses tamper-proof bolts with internal Torx-pin heads to prevent theft of brackets and equipment.
- Salt Spray Enhanced Anti-Corrosion Kit: Specialized for coastal high-corrosion environments, including fluorocarbon paint topcoat and upgraded stainless steel fasteners.
3.3 Unpacking Inspection Requirements
After product arrival, unpacking inspection must be performed on a dry, level site. Check each component’s model, specification, and quantity against the packing list one by one to confirm consistency with the purchase contract.
Inspect the appearance of all components to confirm that the anti-corrosion coating has no peeling or scratches, structural members have no deformation or cracks, threads are not damaged, and plastic parts have no cracking.
Check that technical documents including the product certificate and factory inspection report are complete.
If missing parts, damage, or model discrepancies are found, take photos immediately for documentation and contact the supplier for handling. Non-conforming parts must not be used for installation.
After inspection, properly store components, sort them by category, and avoid impacts that may damage the anti-corrosion coating. Small accessories should be stored in tool boxes to prevent loss.
Chapter 4 Product Working Principle
4.1 Structural Mechanics Principle
The core function of the light pole base station bracket is to safely and evenly transfer the vertical loads and horizontal wind loads of base station equipment to the light pole body. Its mechanical principle is based on the circumferential friction load transfer + multi-point distributed load-bearing mechanism:
Vertical Load Transfer Path: Base station equipment weight → Equipment backplate → Main crossbeam → Main vertical beam → Upper and lower clamps → Friction force at clamp-to-pole contact surfaces → Light pole body → Light pole foundation → Ground.
Horizontal Wind Load Transfer Path: Equipment windward surface wind pressure → Equipment backplate → Main crossbeam → Diagonal brace + Main vertical beam → Clamp assembly → Light pole body → Foundation and ground.
Clamp Friction Load Transfer Principle: Bolt pre-tension forces the two half-clamps to tightly encircle the light pole, generating normal pressure at the contact surfaces. Based on normal pressure and friction coefficient, sufficient static friction is formed to counteract vertical loads and torsional moments, ensuring the bracket does not slide or rotate. Friction is proportional to bolt pre-tension and contact surface friction coefficient; therefore, bolt torque must reach the design value during installation, and contact surfaces must be kept clean and dry.
Triangular Stability Principle: The main crossbeam, main vertical beam, and diagonal brace form a triangular truss structure. Utilizing the geometric stability of triangles, overall structural stiffness is significantly enhanced with the same material usage, reducing deflection deformation under wind loads and ensuring stable equipment posture.
4.2 Anti-Corrosion Protection Principle
In outdoor environments, steel structures face multiple forms of erosion including atmospheric corrosion, rainwater corrosion, and industrial gas corrosion. This product adopts a multi-layer composite anti-corrosion system to ensure structural service life:
Base Layer Hot-Dip Galvanizing: Steel components undergo integral hot-dip galvanizing treatment, forming a zinc-iron alloy layer with thickness ≥85μm. Utilizing the sacrificial anode effect of zinc, cathodic protection is provided to the steel substrate. Even if the surface is locally damaged, it can self-repair, making this the core anti-corrosion method for outdoor steel structures.
Surface Layer Electrostatic Powder Coating: Polyester powder coating is sprayed on the galvanized layer surface and cured at high temperature to form a dense organic coating, further isolating water, oxygen, and corrosive media while providing an attractive appearance color that can match the light pole color.
Node Sealing Protection: Corrosion-prone areas such as bolted connections and welds are treated with conductive anti-corrosion paste + sealant dual treatment to block moisture intrusion paths and prevent electrochemical corrosion.
Stainless Steel Fasteners: All connecting bolts and nuts use 304 or 316 stainless steel, solving fastener corrosion problems from the material itself and avoiding structural loosening caused by bolt rusting.
4.3 Lightning Protection and Grounding Principle
The lightning protection design of the light pole base station bracket follows the principles of equipotential bonding + graded discharge:
Equipotential Bonding: All metal components of the bracket achieve electrical continuity through metal contact surfaces or dedicated jumper wires, making the entire bracket system an equipotential body. During lightning strikes, the potential of all parts rises simultaneously, avoiding potential differences that could puncture equipment interfaces.
Lightning Current Discharge: The bracket is reliably connected to the light pole grounding system through grounding down conductors. During lightning strikes, lightning current discharges rapidly along the path: bracket → grounding terminal → down conductor → light pole grounding electrode → ground, reducing lightning overvoltage amplitude.
Equipment-Side Protection: Combined with power surge protectors and signal surge protectors, surge suppression is applied to power lines and signal lines entering equipment, limiting residual overvoltage to within equipment withstand capability, forming a complete lightning protection system.
4.4 Signal Compatibility Principle
The bracket structural design fully considers the impact on communication signals, following the principles of low passive intermodulation and low signal obstruction:
Non-Metallic Transition Components: Non-metallic vibration isolation pads are used between equipment and bracket, reducing passive intermodulation (PIM) interference generated by metal contact, ensuring communication signal quality.
Structural Avoidance Design: The bracket main structure avoids the antenna main radiation direction, reducing signal reflection and obstruction by metal structures, minimizing impact on antenna radiation patterns.
Non-Magnetized Material Selection: Non-magnetic steel and aluminum alloy materials are selected to avoid electromagnetic field distortion effects.
Chapter 5 Product Technical Parameters
5.1 Structural Mechanics Parameters
| Parameter Item | Technical Specification | Remarks |
|---|---|---|
| Rated Mounting Weight | Single equipment position ≥80kg; dual equipment position ≥150kg | Includes total weight of equipment and accessories |
| Design Wind Resistance Level | Level 12 (wind speed 35m/s); reinforced type up to Level 15 (50m/s) | Corresponding basic wind pressure 0.75kN/m² |
| Seismic Fortification Intensity | 8 degrees (0.2g) | Compliant with GB50011 standard |
| Structural Safety Class | Class II | Design service life 20 years |
| Maximum Crossbeam Deflection | ≤L/200 (L is crossbeam cantilever length) | Under rated load |
| Clamp Anti-Slip Force | ≥10kN | Static friction anti-slip under rated torque |
| Clamp Anti-Torsional Moment | ≥3kN·m | Prevents bracket rotation around pole |
| Bolt Tightening Torque | M16: 120N·m; M12: 65N·m; M10: 40N·m | Standard values for Grade 8.8 bolts |
5.2 Material and Anti-Corrosion Parameters
| Parameter Item | Technical Specification | Remarks |
|---|---|---|
| Main Structure Material | Q355 high-quality carbon structural steel | 6061-T6 aluminum alloy optional |
| Fastener Material | 304 stainless steel (standard); 316 stainless steel (coastal optional) | Grade not lower than A2-70 |
| Hot-Dip Galvanizing Layer Thickness | ≥85μm | Compliant with GB/T 13912 standard |
| Surface Powder Coating Thickness | 60~100μm | Polyester powder coating |
| Neutral Salt Spray Test | ≥1000 hours without red rust | Hot-dip galvanizing + powder coating composite layer |
| Operating Temperature Range | -40°C ~ +65°C | Suitable for most regions nationwide |
| Ambient Humidity | 5% ~ 100%RH (including condensation) | — |
5.3 Adaptation Parameters
| Parameter Item | Technical Specification | Remarks |
|---|---|---|
| Compatible Light Pole Diameter | Standard φ114~φ165mm; optional full range φ60~φ325mm | Round light poles |
| Compatible Light Pole Cross-Section | Round as standard; square, polygonal, tapered poles optional | Custom clamps |
| Installation Height Range | 3m ~ 12m (effective installation section of light pole) | Determined by light pole height |
| Equipment Mounting Hole Spacing | Compatible with mainstream hole spacings including 100×100mm, 200×200mm | Custom hole patterns available |
| Tilt Angle Adjustment Range | 0° ~ 15° continuously adjustable | Some models support ±30° |
| Horizontal Azimuth Fine Adjustment Range | ±5° | 360° rotation possible after clamp loosening |
5.4 Electrical and Lightning Protection Parameters
| Parameter Item | Technical Specification | Remarks |
|---|---|---|
| Grounding Resistance Requirement | ≤4Ω (combined grounding) | Shares grounding system with light pole |
| Equipotential Bonding Resistance | ≤0.1Ω | Between metal components |
| Grounding Down Conductor Cross-Section | ≥16mm² stranded copper core | ≥25mm² recommended for high lightning areas |
| Power Frequency Withstand Voltage | 2kV/1min no breakdown | Between live parts and bracket |
| Insulation Resistance | ≥2MΩ | Under normal environmental conditions |
5.5 Dimensional Parameters (Standard Single Equipment Position)
- Main Crossbeam Length: 600mm
- Main Vertical Beam Height: 800mm
- Diagonal Brace Length: approximately 720mm
- Overall Bracket Cantilever Distance: approximately 550mm from light pole outer wall to equipment mounting surface
- Clamp Center Distance: 600mm
- Packaging Dimensions: 900×400×200mm
- Complete Set Installed Weight: approximately 28kg
Chapter 6 Product Functions and Features
6.1 Core Functions
Equipment Load-Bearing Function: Provides a stable installation support platform for base station AAU, RRU, antenna, and other equipment, withstanding equipment dead weight and additional loads including wind loads and ice/snow loads, ensuring long-term stable equipment operation.
Position Adjustment Function: Supports flexible adjustment of installation height, horizontal azimuth, and tilt angle, facilitating on-site optimization of equipment posture according to coverage requirements for optimal signal coverage.
Cable Management Function: Provides standardized cable routing channels and fixing structures, protecting feeders, power cables, and transmission cables from external force damage, reducing wind-induced abrasion, and extending cable service life.
Lightning Protection and Grounding Function: Integrates equipotential bonding and grounding terminals, providing reliable lightning discharge paths for equipment and reducing lightning damage risk.
Multi-Equipment Co-Mounting Function: Supports co-mounting of multiple operator and multi-system equipment on a single pole, achieving shared construction of infrastructure and reducing duplicate construction.
Landscape Integration Function: Clean and coordinated appearance, customizable color, seamlessly integrated with light poles and surrounding environment, avoiding the visual abruptness of traditional base stations.
6.2 Product Features
6.2.1 Safe and Reliable Structure
- Strictly calculated according to national steel structure design standards and communication industry bracket standards, verified through third-party load testing with sufficient safety margins.
- Triangular truss structural system with excellent bending and torsional resistance; equipment swing amplitude controlled within design range under Level 12 strong winds, ensuring signal stability.
- Dual anti-slip design: anti-slip teeth on clamp inner surface + rubber pads provide dual friction enhancement, combined with anti-loosening bolts, eliminating bracket sliding and rotation risks.
- Full lifecycle structural safety design with redundant key node design; overall failure will not occur even if a single bolt loosens.
6.2.2 Efficient and Convenient Installation
- Fully assembled structure, factory prefabricated, no on-site welding or drilling required, assembly can be completed with ordinary tools only.
- Modular design with lightweight components; two persons can complete high-altitude installation without large hoisting equipment, significantly reducing construction difficulty and cost.
- Universal adaptation design; one bracket set adapts to multiple light pole diameters, reducing inventory models and improving engineering response speed.
- Installation efficiency improvement: compared to traditional welded brackets, single-point installation time is reduced by more than 70%; a skilled crew can complete 10–15 installations per day.
6.2.3 Excellent Corrosion Resistance and Durability
- Hot-dip galvanizing + electrostatic powder coating dual anti-corrosion system; design service life exceeds 20 years under normal outdoor environments, significantly reducing later maintenance costs.
- All fasteners use stainless steel, fundamentally solving bolt rusting and seizure problems, facilitating later maintenance and disassembly.
- Upgraded anti-corrosion solutions available for coastal, industrial, and other high-corrosion environments to further extend service life.
- On-site repair kit included; anti-corrosion coating damage during installation can be immediately repaired to ensure anti-corrosion system integrity.
6.2.4 Maintenance-Friendly and Convenient
- Ample operating space reserved; equipment installation, removal, and wiring operations are convenient; equipment can be replaced without removing the bracket main body.
- Standardized interface design; equipment upgrades do not require bracket replacement, compatible with new and old equipment, protecting investment.
- Simple structural design with clear routine inspection points, easy troubleshooting, and low maintenance threshold.
- Spare parts common across the full product series, facilitating maintenance materials storage.
6.2.5 Economical, Environmentally Friendly, and Efficient
- Base stations built on existing light poles, no land acquisition or new tower construction required, significantly reducing construction and coordination costs.
- Shares light pole power supply, grounding, and pipeline resources, reducing duplicate pipeline construction and shortening construction periods.
- Products are recyclable; steel can be recycled after replacement and removal, consistent with green building concepts.
- Batch industrialized production ensures stable quality and controllable costs, offering higher cost-effectiveness compared to on-site custom brackets.
6.2.6 Excellent Electromagnetic Performance
- Structural design avoids antenna main radiation direction; signal obstruction loss less than 0.5dB, essentially no impact on coverage effectiveness.
- Low PIM design reduces intermodulation interference from metal contact, ensuring 5G high-frequency band signal quality.
- Equipotential design avoids transmission signal interference from ground potential differences, enhancing communication system stability.
Chapter 7 Product Application Scenarios
With the advantages of flexible deployment, low cost, and excellent landscape compatibility, light pole base station brackets are widely used in various scenarios requiring deep coverage and coverage gap filling of communication networks. The following are typical application scenarios and deployment points:
7.1 Urban Municipal Road Scenario
Urban main roads, secondary roads, branch roads, and back streets/alleyways are the primary application scenarios for light pole base station brackets. Urban road light poles are uniformly distributed with reasonable spacing (generally 30–50m), with heights mostly 8–12m, making them highly suitable for continuous 5G micro base station coverage deployment.
Deployment Characteristics: Alternating or single-side deployment along road light poles on both sides, forming continuous coverage belts to address signal coverage issues on road surfaces and along-street businesses.
Equipment Configuration: 1–2 AAU units mounted per pole, oriented toward the road direction, with tilt angle adjusted according to road width to achieve deep road surface coverage.
Selection Recommendations: Standard clamp-type brackets suitable for municipal common φ140 and φ165 light poles, exterior color consistent with street light poles.
7.2 Commercial District Scenario
Commercial areas, pedestrian streets, and food streets have dense pedestrian traffic and high data service demand, making them key areas for 5G capacity absorption. These areas have dense buildings where traditional macro stations cannot penetrate deeply; light pole base stations enable precise supplementary point coverage.
Deployment Characteristics: Deployed on pedestrian street landscape light poles and courtyard light poles with dense points, absorbing high traffic volume while maintaining landscape aesthetics.
Equipment Configuration: Mostly small-form-factor AAU or micro base stations; brackets adopt concealed designs to minimize visual impact.
Selection Recommendations: Aluminum alloy lightweight brackets, exterior color matching landscape lights, custom shapes available.
7.3 Industrial Park Scenario
Industrial parks, technology parks, and logistics parks have large areas and numerous factory buildings where traditional base station signals experience severe obstruction. Park internal light pole resources are abundant, making them suitable for batch deployment of light pole base stations.
Deployment Characteristics: Deployed on park road light poles and factory area lighting poles, achieving comprehensive coverage of park roads, factory building surroundings, and office areas.
Equipment Configuration: Equipment power selected according to factory building height and obstruction conditions; some points may add RRU remote units.
Selection Recommendations: High-load reinforced brackets; some points may integrate surveillance cameras, environmental monitoring, and other equipment for one-pole-multiple-use.
7.4 Residential Community Scenario
Residential communities are high-incidence areas for user complaints about weak signals. Traditional base station entry into communities faces significant coordination difficulty. Deploying base stations using existing community light poles can effectively reduce coordination resistance.
Deployment Characteristics: Distributed deployment on community road light poles and landscape light poles, addressing signal coverage in building low levels, underground garage entrances, community roads, and other areas.
Equipment Configuration: Low-power micro base stations, controlling coverage range to avoid interference with surrounding areas.
Selection Recommendations: Small-form-factor, inconspicuous brackets with appearance coordinated with community environment to reduce resident attention.
7.5 Tourist Attraction Scenario
Tourist attractions have high landscape requirements, and traditional tower base stations severely impact visual aesthetics. Light pole base station brackets deployed on attraction street lights and landscape lights balance communication coverage with landscape protection.
Deployment Characteristics: Deployed along attraction pathways and around visitor service points on light poles, achieving signal coverage in tourist activity areas.
Equipment Configuration: Concealed antennas with brackets designed integrally with landscape lights for strong concealment.
Selection Recommendations: Customized appearance brackets with colors and materials matching attraction style; bionic or antique styles available.
7.6 Campus and Hospital Scenario
Campus and hospital areas have dense populations and high communication demand, while also being highly sensitive to electromagnetic radiation. Light pole base stations feature low power and uniform distribution, meeting coverage needs while being more easily accepted by the public.
Deployment Characteristics: Deployed on campus roads, playground perimeters, and hospital compound light poles, avoiding positions directly facing dormitory and ward building windows.
Equipment Configuration: Low-power micro base stations with controlled radiation intensity; scientific publicity should be conducted.
Selection Recommendations: White or light gray brackets with clean appearance, coordinated with hospital compound environment.
7.7 Township and Rural Scenario
In townships and rural areas, base station coverage spacing is large and signals inside villages are weak. Deploying base stations on village/town main road light poles can achieve low-cost village coverage.
Deployment Characteristics: Deployed along township main street light poles, addressing coverage of town streets and surrounding residential areas.
Equipment Configuration: Medium-power equipment selected to expand single-station coverage range and reduce station count.
Selection Recommendations: Economical galvanized brackets to reduce construction cost while meeting basic functional requirements.
7.8 Special Scenario Applications
Tunnel Entrance/Overpass Underside: Deployed on tunnel entrance lighting poles and overpass street lights, addressing signal handover issues at tunnel entrances and weak signals under bridges.
Large Venue Surroundings: Deployed on light poles around stadiums and convention centers, supplementing capacity demand during large events.
Transportation Hubs: Deployed on light poles around railway stations, bus stations, and subway stations, relieving traffic pressure in high-density pedestrian areas.
Chapter 8 Product Installation
8.1 General Installation Construction Rules
All installation operations must strictly comply with national safety production laws and regulations, implement high-altitude operation safety specifications, and ensure the personal safety of construction personnel.
Before installation, complete construction drawings and technical disclosure documents must be available, clearly specifying technical requirements including installation position, height, and orientation.
Only qualified product components and matching tools must be used. Use of deformed, corroded, or incomplete non-conforming products is strictly prohibited.
The installation process must strictly follow the process steps specified in this manual. Key parameters including torque, verticality, and levelness must meet requirements. Skipping steps or simplifying processes is strictly prohibited.
High-altitude installation operations are prohibited during severe weather conditions including thunderstorms, strong winds (wind speed ≥10m/s), and heavy fog.
After construction completion, self-inspection must be performed as required, and construction records and photographic documentation must be retained.
8.2 Pre-Construction Preparation
8.2.1 Technical Preparation
- Familiarize with construction drawings and site design documents, clarifying technical requirements for each point including bracket model, installation height, equipment orientation, and cable routing.
- Verify light pole diameter, material, wall thickness, existing loads, and other parameters for each point, confirming compatibility with the bracket. If light pole wall thickness is insufficient or corrosion is severe, light pole reinforcement or replacement evaluation must be performed first.
- Prepare a dedicated construction plan, defining construction process, personnel assignments, safety measures, and emergency response plans.
- Conduct technical and safety disclosure sessions for construction personnel; personnel may only begin work after signing confirmation.
- Apply in advance for construction permits, road occupancy permits, high-altitude operation permits, and other relevant approvals, coordinating with relevant management departments.
8.2.2 Personnel Preparation
- Each construction crew shall be configured with at least 3 persons: 1 high-altitude operator and 2 ground support personnel. Personnel ratio may be adjusted based on operational difficulty.
- High-altitude operators must hold valid high-altitude operation certificates, be in good health, and have no contraindicated conditions including hypertension, heart disease, or acrophobia.
- Construction personnel must wear safety helmets, safety harnesses, anti-slip shoes, and other personal protective equipment. High-altitude safety harnesses must have dual hooks with dual attachment points, following the “high-hook, low-use” principle.
- Pre-job training shall be provided to personnel to familiarize them with product structure, installation steps, and safety precautions.
8.2.3 Tools and Materials Preparation
Installation Tools: Torque wrench (adjustable torque), open-end wrenches, adjustable wrenches, hex key set, spirit level (magnetic), tape measure, marker pen, utility knife, insulating tape, sandpaper, etc.
Hoisting Tools: High-altitude operation specialized pulleys, lifting ropes, tool bags, safety ropes. Depending on installation height, aerial work vehicles, lifting platforms, or climbing ladders may be selected.
Inspection Tools: Ground resistance tester, torque wrench, feeler gauge, verticality measuring instrument (or theodolite).
Auxiliary Materials: Anti-corrosion touch-up paint, conductive paste, waterproof sealant, cable ties, identification plates, anti-rust grease, cleaning cloths, etc.
All tools must be inspected and calibrated before entering the site to ensure they are intact and functional. Measuring instruments must be within their calibration validity period.
8.2.4 On-Site Survey and Environment Preparation
- Conduct on-site survey of each station before construction to confirm light pole condition: no obvious pole inclination, no severe corrosion at the base, no cracking of welds, and no foundation settlement or damage.
- Confirm no obstacles below the installation position and that a safety warning zone can be established in the work area to prevent pedestrian and vehicle entry.
- Confirm pole internal cable pass-through channels are clear, grounding system is available, and power supply point locations are defined.
- Clear the work site, remove flammable and explosive items, delineate construction warning zones, and set up warning signs.
- If road occupancy is required, place traffic cones and warning lights in advance and assign personnel for traffic direction.
8.2.5 Safety Technical Disclosure
- Clarify the day’s work content, work scope, hazard points, and prevention and control measures.
- Emphasize high-altitude operation safety specifications: correct safety harness wearing, tool fall prevention, prohibition of throwing objects, and coordinated communication between heights.
- Clarify electrical safety requirements: standard temporary power connection, prohibition of unauthorized wiring.
- Clarify emergency response procedures: emergency measures and reporting procedures for accidents including falls from height, object strikes, and electric shock.
8.3 Foundation and Light Pole Verification
8.3.1 Light Pole Foundation Verification
- Inspect light pole foundation concrete appearance for large-area honeycombing, exposed rebar, or cracks; foundation top surface must be level.
- Check the tightness of light pole base flange bolts for looseness or corrosion; flange must be firmly seated on the foundation.
- For light poles in service for more than 10 years, foundation settlement must be checked. If obvious inclination exists, safety assessment must be conducted first; bracket installation is permitted only after passing assessment.
- Confirm the light pole grounding system is intact and grounding resistance meets design requirements. If original grounding has failed, the grounding system must be rectified simultaneously.
8.3.2 Light Pole Body Verification
- Measure the actual diameter of the light pole at the installation position, verifying consistency with bracket clamp adaptation range. If deviation exceeds 5mm, replace with an adapted clamp or add shims.
- Check roundness and flatness of the pole body at the installation section. Locations with dents or deformation exceeding 3mm depth are unsuitable as clamp installation positions and the position should be adjusted up or down.
- Check the condition of the pole body anti-corrosion coating. If blistering or peeling exists at the clamp installation position, clean and smooth the surface before installation.
- Verify light pole wall thickness. For thin-wall light poles with wall thickness less than 3mm, load-bearing capacity verification is required; pole internal reinforcement measures should be taken if necessary.
- Confirm pole body cable pass-through hole locations, ensuring cables can be smoothly routed from inside the pole to equipment installation positions.
8.4 Ground-Level Pre-Assembly of Bracket
8.4.1 Component Inspection and Pre-Treatment
- Remove all bracket components from packaging, arrange by category, and recount quantities and inspect appearance.
- Clean dust and oil from component surfaces; apply a small amount of anti-rust grease to threaded areas to facilitate installation and later disassembly.
- Check that all bolt threads are intact and nuts thread on smoothly; clean any burrs.
- Apply anti-slip rubber pads to clamps, ensuring smooth adhesion without edge lifting.
8.4.2 Main Structure Pre-Assembly
- On a level ground surface, initially connect the main crossbeam and main vertical beam with connecting bolts without fully tightening.
- Install the diagonal brace, connecting the crossbeam outer end and the lower portion of the vertical beam respectively, forming a triangular frame.
- Use a spirit level to adjust crossbeam levelness, then tighten all structural connecting bolts to the specified torque.
- Install the equipment mounting backplate and angle adjustment mechanism, initially fixing at the crossbeam center position.
- Install the cable tray and grounding terminal block, fixed to the inner side of the main vertical beam.
- Perform an overall inspection of the frame structure to confirm no deformation, secure connections, and smooth operation of adjustment mechanisms without sticking.
8.4.3 Pre-Assembly Precautions
- Bolt insertion direction should be consistent during assembly, generally inserted from inside to outside and from top to bottom, with nuts on the operating side.
- All bolts must be equipped with flat washers and spring washers. Flat washers face the component surface; spring washers are on the nut side.
- When tightening bolts, use the diagonal alternating tightening method to avoid component deformation from uneven force.
- After pre-assembly, lift the complete assembly to the installation position to reduce high-altitude work and improve construction efficiency and safety.
8.5 Bracket High-Altitude Installation
8.5.1 Installation Position Marking
- Based on the installation height specified in the design, measure upward from the ground reference point of the light pole using a tape measure to determine the installation height, and draw the centerline for the upper clamp installation on the pole with a marker pen.
- According to the clamp spacing, draw the centerline for the lower clamp installation, ensuring the two lines are level and the spacing is accurate.
- Mark the reference line for equipment orientation. Determine the front-facing direction of the equipment based on the design azimuth angle using a compass, and draw corresponding marks on the pole body.
8.5.2 Bracket Hoisting and Positioning
- Slowly hoist the pre-assembled bracket main body using lifting ropes. High-altitude workers should coordinate and guide the bracket towards the installation position on the light pole.
- First, position one half of the upper clamp at the marked location, initially close the clamp, insert the bolts, and hand-tighten the nuts without securing them fully.
- Install the lower clamp using the same method, ensuring the bracket’s vertical beam is flush against the pole and the overall assembly is roughly vertical.
- Adjust the horizontal orientation of the bracket so that the equipment orientation aligns with the design marks.
8.5.3 Clamp Tightening Operation
- After confirming the bracket position and orientation are correct, tighten the clamp bolts.
- Use the diagonal alternating tightening method, progressively tightening the bolts on both sides of the clamp to ensure even force distribution and that the clamp fits snugly against the pole’s circumference.
- Use a torque wrench to tighten the M16 clamp bolts to the specified torque value of 120 N·m. Tighten each bolt twice to ensure the preload force meets requirements.
- During tightening, continuously check the bracket’s verticality and adjust promptly if any deviation occurs.
- After all tightening is complete, use a feeler gauge to check the gap between the clamp and the pole. The maximum gap must not exceed 0.5 mm, and the gap around the circumference should be uniform.
8.5.4 Verticality and Levelness Correction
- Use a magnetic level to check the levelness of the main crossbeam, ensuring deviation does not exceed 1 mm per meter.
- Use a spirit level or theodolite to check the verticality of the main vertical beam, with deviation not exceeding 1‰ of its height.
- If levelness or verticality does not meet standards, adjust by adding or removing shims between the clamp and the pole. It is strictly forbidden to force the bracket into position by prying or bending.
- After correction, re-check the torque of all clamp bolts to confirm none are loose.
8.5.5 Equipment Mounting Backplate Adjustment
- Adjust the vertical position of the backplate on the crossbeam according to the equipment installation height requirements, then tighten the fixing bolts.
- Initially adjust the tilt angle to the design value and lock the adjustment bolts.
- Check the flatness of the backplate mounting surface for any warping or deformation.
8.6 Base Station Equipment Installation
8.6.1 Pre-Installation Inspection of Equipment
- Inspect the base station equipment’s exterior for any impact damage, water ingress, or deformation, and verify all accessories are present.
- Verify that the equipment’s mounting hole spacing matches the backplate holes. Replace with a suitable backplate or adapter plate if they do not match.
- Clean the equipment mounting surface to ensure it is flat and free of debris.
8.6.2 Equipment Fixing and Installation
- Apply the damping pads to the corresponding positions on the equipment’s backplate.
- Two people should coordinate to lift the equipment to the installation position, align the mounting holes, and insert the fixing bolts.
- Initially tighten the nuts, adjust the equipment to ensure it is centered, then tighten the bolts diagonally and alternately. The torque value should follow the equipment manual, generally 40 N·m for M10 bolts.
- Install the bottom limit stop block to support the bottom of the equipment.
- Fine-tune the tilt angle and horizontal orientation. Lock all adjustment bolts once they meet the design requirements.
8.6.3 Equipment Installation Inspection
- Check that the equipment is installed securely, with no looseness or wobble. There should be no visible displacement when lightly pushed by hand.
- Re-verify the equipment orientation and tilt angle, ensuring errors are within the allowable range.
- Inspect the equipment’s exterior for any damage, and confirm that the interface protective covers are intact (remove only during wiring).
8.7 Auxiliary Component Installation
- Install cable clamps at intervals of 500 mm to securely fix the cable tray.
- Install the grounding terminal block securely. Grind the contact surface to remove the oxide layer and apply conductive paste.
- Install waterproof cable glands at the threading holes and tighten to seal.
- Install the identification plate in a visible position at the lower part of the bracket, marking the site number, equipment information, and property owner.
- Install equipotential bonding straps, bridging the bracket and the light pole, ensuring good electrical connectivity.
8.8 Initial Inspection After Installation
- Structural Check: All bolts are tightened securely, torque meets standards, components show no deformation or damage to the anti-corrosion coating, the bracket assembly is stable with no significant sway when shaken by hand.
- Position Check: Installation height, equipment orientation, and tilt angle meet design requirements, with deviations within allowable limits.
- Appearance Check: Overall cleanliness, all parts present, anti-corrosion coating intact, and no significant color difference at repair points.
- Safety Check: No sharp burrs, no risk of cable damage at cable entry points, and reliable grounding connections.
- Fill out the installation self-inspection record form and take panoramic and detailed photos of the completed installation for archival purposes.
Chapter 9: Product Wiring
9.1 General Principles for Wiring Construction
- All wiring operations must comply with the “Code for Construction and Acceptance of Cable Lines for Electrical Equipment Installation Engineering” (GB 50168-2018) and relevant communications industry standards to ensure electrical safety and signal quality.
- Wiring operations must be performed by certified electricians and communications technicians working together. Individuals without certification are strictly prohibited from performing electrical wiring operations.
- Before wiring, it is mandatory to confirm that the power supply side is de-energized and to hang a sign reading “Man Working, Do Not Close Switch.” Implement the lockout/tagout procedure (power off, verify no voltage, tag, lock).
- All cables must have product qualification certificates, and specifications/models must meet design requirements. Using unqualified cables is strictly prohibited.
- Wiring must be secure, have good insulation, be waterproof and sealed, have clear identification, and be neatly organized, separating strong current from weak current cables.
- For high-altitude wiring operations, anti-drop measures for tools and cables must be in place. Throwing cables or tools is strictly prohibited.
9.2 Cable Selection and Laying Specifications
9.2.1 Common Cable Types and Specifications
| Cable Purpose | Recommended Specification | Technical Requirements |
|---|---|---|
| Equipment AC Power Cable | RVV 3×2.5mm² | Flame retardant, weather resistant, sheath thickness ≥ 1.5mm |
| Equipment DC Power Cable | RVV 2×4mm² | Flame retardant, withstand voltage > 60V |
| Grounding Down Conductor | BV 16mm² Stranded Copper | Yellow/Green two-color, tin-plated copper core |
| RF Feeder Cable | 1/2″ Super Flexible | Low loss, matches equipment frequency band |
| Fiber Optic Cable | Single-mode Armored 2/4 cores | Non-metallic strength members, outdoor type |
| Monitoring/Control Cable | RVVP 2×1.0mm² | Shielded, anti-interference |
9.2.2 General Requirements for Cable Laying
- Conduct a visual inspection before laying cables. The sheath should be free of damage, cracks, or crushing, and the cable model and specifications must match the design.
- The cable routing path should be the shortest and most direct, minimizing bends. Bending radius requirements: Power cables ≥ 10 times cable diameter, feeder cables ≥ 20 times cable diameter, optical cables ≥ 30 times cable diameter.
- Separate strong current and weak current cables during laying, maintaining a spacing of no less than 50 mm. If separation is unavoidable, use metal shielding conduits.
- Cables must be laid in single continuous runs without splices. If a splice is necessary under special circumstances, waterproof insulation treatment must be applied, and the splice must be placed in a waterproof junction box.
- Reserve sufficient margin at both ends of the cable: 0.5 to 1 m at the equipment end and 1 to 1.5 m at the lower end, to facilitate future maintenance and adjustments.
- During laying, avoid dragging, stepping on, or squeezing the cables. Sharp bends and heavy object pressure are strictly prohibited.
9.3 Power Supply System Wiring
9.3.1 Power Supply Circuit Design
- The power supply for a light pole base station typically originates from the existing power circuit of the light pole, using AC220V mains power. It passes through a surge protector, circuit breaker, and then connects to the base station equipment’s power module. Some scenarios use a DC remote power supply system.
- Power supply circuit sequence: Mains power → Main circuit breaker in distribution box → Power surge protector → Branch circuit breaker → Energy meter → In-pole power cable → Equipment-side circuit breaker → Base station power module → Equipment DC output.
9.3.2 In-Pole Power Cable Laying
- Thread the power cable through the maintenance access door at the bottom of the pole and lay it upward along the internal threading channel, exiting through the threading hole at the bracket installation height.
- Secure the cable inside the pole to the internal ladder or cable rack using cable ties every 1 meter to prevent swaying and chafing.
- Install a waterproof cable gland at the threading hole. Pass the cable through the gland and tighten the gland nut to compress the seal ring, achieving a waterproof seal.
- After exiting, route the cable along the bracket’s cable tray to the equipment, leaving sufficient margin.
9.3.3 Equipment-Side Wiring
- Open the protective cover of the equipment’s power interface, verify the interface definition, and confirm the correspondence of positive/negative poles and live/neutral/ground wires.
- Strip the insulation layer at the cable end to a length matching the terminal, ensuring the copper core is free of oxidation and broken strands.
- Crimp appropriate size cold-pressed terminals for a secure connection, which should not pull off under tension tests.
- Connect to the equipment power terminal according to the markings: Live wire to L, Neutral wire to N, Ground wire to PE. Tighten the connection screws securely to ensure good contact.
- For DC powered equipment, strictly distinguish between positive and negative poles. Reversed polarity can damage the equipment and is strictly prohibited.
- After wiring, organize the cables and secure them neatly with clamps to prevent strain on the connection terminals.
9.3.4 Distribution Box-Side Wiring
- Turn off the corresponding branch circuit breaker inside the distribution box and verify with a voltage tester that the circuit is de-energized.
- Connect the power supply cable to the output terminal of the branch breaker and the ground wire to the grounding bar.
- Use a dedicated 2P circuit breaker for the circuit, selecting the rated current based on equipment power. Generally, 16A can meet the requirements of a single AAU.
- Connect a power surge protector in series with the top of the breaker, connecting its grounding terminal to the nearest point on the grounding bar.
- After wiring, check the phase sequence, confirm the live, neutral, and ground wire connections are correct, and ensure there is no short circuit.
9.4 RF Feeder Cable Wiring
9.4.1 Feeder Cable Laying
- Inspect the feeder cable before laying for hard kinks, damage, or water ingress. Use a multimeter to test that there is no short circuit between the inner conductor and outer conductor.
- Route the feeder cable from the equipment room or remote unit, up along the inside of the light pole, and exit at the bracket position.
- The bending radius of the feeder cable must be no less than 20 times its diameter; sharp kinks are strictly prohibited.
- Secure the feeder cable every 1 meter. Create a “drip loop” before entering the equipment to prevent rainwater from flowing along the cable into the equipment interface.
- Attach identification labels to both ends of the feeder cable, indicating the start and end sites and sector direction.
9.4.2 Feeder Connector Fabrication
- Strip the outer sheath, outer conductor, and dielectric layer of the feeder cable end according to fabrication specifications. Ensure accurate dimensions, smooth cuts, and no burrs or metal shavings.
- Assemble the connector components in sequence and use specialized tools for crimping to ensure good contact between the inner and outer conductors.
- After fabrication, use a multimeter to test the connector for continuity and insulation, checking for short or open circuits.
- Wrap the connector area with at least 3 layers of waterproof tape, then apply a waterproof heat-shrink tubing and heat it to shrink, providing dual-layer waterproofing.
9.4.3 Equipment Connection
- Remove the protective cap from the equipment’s antenna interface and clean the interface end face, ensuring it is free of dust and debris.
- Align the feeder connector with the equipment interface, hand-tighten by turning until snug, then use a torque wrench to tighten to the specified torque. Generally, 25~30 N·m for 7/16 connectors.
- Do not force the connector in, to prevent thread stripping and damage to the equipment interface.
- After connection, gently pull the feeder cable to confirm the connector is tight and secure.
- Leave a drip loop below the connector to prevent rainwater from entering the interface.
9.5 Fiber Optic Transmission Wiring
9.5.1 Optical Cable Laying
- When laying armored optical cables, the pulling force must not exceed the cable’s allowable tension. Pull slowly and uniformly, avoiding jerky movements.
- Route the cable along the inside of the pole, with fixing intervals no greater than 1.5 meters, and bending radius no less than 30 times the cable diameter.
- Reserve sufficient margin at both ends of the optical cable, with 1 to 2 meters at the equipment end for splicing and adjustment.
- Install a waterproof cable gland at the point where the cable enters the equipment chassis and ensure it is properly sealed.
9.5.2 Fiber Splicing and Termination
- Professional splicing personnel must use a fusion splicer to perform the splicing. Splicing loss should be controlled within 0.03 dB.
- After splicing, install heat-shrink protective sleeves. Pay attention to the bending radius when coiling the fiber to prevent breakage.
- Use corresponding connectors (LC/SC/FC, etc.) at the equipment end. Clean the end face before inserting into the optical module.
- Secure the splice tray inside the equipment chassis, with clear markings indicating fiber core numbers and purposes.
9.5.3 Performance Testing
- Use an Optical Time Domain Reflectometer (OTDR) to test the loss of the entire optical path and record the test data.
- Test the received optical power, which should be within the sensitivity range of the equipment’s optical module, generally not less than -12 dBm.
- If the test fails, investigate splice points and bend points, and rework them until the performance meets standards.
9.6 Grounding System Wiring
9.6.1 Grounding System Composition
- The light pole base station uses a unified grounding method, including: bracket body grounding, equipment enclosure grounding, surge protector grounding, and shield layer grounding. All grounds are combined and connected to the light pole grounding system, with a grounding resistance ≤ 4Ω.
9.6.2 Equipotential Connection between Bracket and Light Pole
- Grind the paint at the connection point between the bracket and the light pole to expose bare metal, and apply conductive paste.
- Use a copper bonding strap, fixing both ends to the bracket and pole with bolts, ensuring good electrical continuity and a connection resistance ≤ 0.1Ω.
- After the equipotential connection, apply anti-corrosion paint to the ground areas.
9.6.3 Equipment Grounding Wiring
- Connect the equipment’s enclosure grounding terminal to the bracket’s grounding terminal block using a yellow/green grounding wire with a cross-section of no less than 6mm².
- Ground the outer conductor of the feeder cable at the cable entry point near the equipment, connecting it to the grounding bar via a grounding clamp.
- Connect the grounding terminals of power and signal surge protectors to the nearest point on the grounding bar using copper wire no smaller than 10mm².
- All grounding wires should be yellow/green twisted type, with securely crimped terminals and no looseness.
9.6.4 Grounding Down Conductor Installation
- Route a 16mm² yellow/green grounding down conductor from the grounding terminal block, down along the light pole, securing it firmly.
- Connect the down conductor to the grounding terminal at the base of the pole or directly to the ground grid’s grounding electrode.
- Remove the oxide layer at the connection point, apply conductive paste, and tighten the bolts.
- Use a ground resistance tester to measure the grounding resistance, which is considered qualified if ≤ 4Ω. If not qualified, add grounding electrodes or take resistance-reduction measures.
9.7 Cable Organization and Identification
- After all wiring is complete, organize the cables neatly along the cable tray and secure them with cable clamps at uniform spacing and appropriate tightness.
- Bundle cables neatly, keeping them horizontal and vertical, without crossing or tangling.
- Attach identification labels to both ends of all cables, indicating cable number, model, start and end points, and purpose. The labels should have clear, waterproof, and weather-resistant printing.
- Coil any excess cable neatly, securing it below the equipment or inside the chassis, ensuring the coil radius meets requirements.
- Clean up debris and waste at the wiring area to ensure it is clean and dry.
9.8 Post-Wiring Electrical Testing
- Insulation Resistance Test: Use a 500V megohmmeter to test insulation resistance between the power line phase/neutral wires and the ground wire. Values ≥ 2MΩ are qualified.
- Continuity Test: Test continuity of all circuits, ensuring there are no open circuits or loose connections.
- Grounding Resistance Test: Test the system grounding resistance to ensure it meets design requirements.
- Phase Sequence Test: Test that the power supply phase sequence is correct, with no missing or reversed phases.
- Short Circuit Test: Test for short circuits before energizing. Only proceed with power-on after confirming no short circuit faults.
- Fill out the wiring test record form and retain the test data.
Chapter 10: Product Commissioning
10.1 General Principles for Commissioning
- Commissioning must only be carried out after installation and wiring are fully completed, and self-inspection has passed.
- Commissioning personnel must possess the necessary professional qualifications and be familiar with base station equipment performance and commissioning methods.
- Develop a detailed commissioning plan before starting, clarifying commissioning items, test methods, acceptance criteria, and personnel responsibilities.
- Strictly follow operating procedures during commissioning. Hot-swapping equipment boards and interfaces is strictly prohibited to prevent damage.
- Keep detailed records during the commissioning process. Test data must be accurate and truthful. Issue a formal commissioning report upon completion.
- Immediately cut off power and investigate any issues found during commissioning. Operating equipment in a faulty state is strictly prohibited.
10.2 Comprehensive Pre-Power-On Inspection
10.2.1 Structural Safety Re-check
- Re-check all connecting bolts, especially clamp bolts and equipment mounting bolts, ensuring torque meets requirements and none are loose.
- Check that the bracket assembly has no deformation or tilting, and that equipment is securely mounted without wobbling.
- Verify that all metal components are reliably connected and the equipotential bonding is intact.
- Check that cable trays and cables are securely fixed, with no risk of falling.
10.2.2 Wiring Correctness Re-check
- Verify power supply connections: positions of live, neutral, and ground wires are correct, with no reversal or misconnection.
- Verify DC connections: polarity of positive and negative terminals is correct, with no risk of reverse connection.
- Verify feeder connections: transmit and receive are correctly matched, with no crossover or reversal.
- Verify fiber optic connections: fiber core numbers correspond correctly, and connectors are clean.
- Verify grounding connections: all grounding points are securely connected, with no loose connections.
- Check that all interfaces are fully seated and secure, with no looseness or poor contact.
10.2.3 Insulation and Grounding Tests
- Disconnect all equipment breakers, and test that the insulation resistance of the power circuit is ≥ 2MΩ.
- Test that the inner and outer conductors of the feeder cable are well insulated with no short circuit.
- Re-measure the grounding resistance and confirm it is ≤ 4Ω, recording the measured value.
- Test the continuity between the equipment enclosure and the grounding bar, which should have a resistance ≤ 0.5Ω.
10.2.4 External Environment Check
- Confirm the supply voltage is normal, with AC220V deviation within ±10%.
- Confirm there is no thunderstorm weather and that the ambient temperature is within the equipment’s operating temperature range.
- Confirm the commissioning area is free from strong electromagnetic interference and flammable/explosive materials.
- Confirm site safety measures are in place and emergency procedures are ready.
10.3 Individual Equipment Power-On Commissioning
10.3.1 Power Supply System Energization
- Keep the equipment-side breaker off. First close the main breaker in the distribution box, then close the branch breaker.
- Use a multimeter to test the supply voltage at the equipment end, confirming normal voltage and no missing phase.
- Close the equipment-side breaker and observe the status of the equipment’s power indicator light, confirming normal power-up.
- Test the equipment input current, ensuring it is within the rated range with no overcurrent phenomenon.
- Observe the equipment for 10 minutes of operation, checking for abnormal heat, noise, or odor.
10.3.2 Equipment Startup Self-Check
- After power-up, wait for the system to boot, observe the status of each indicator, and compare with the equipment manual to confirm the startup sequence is normal.
- Check that the equipment fans are running normally and heat dissipation is adequate.
- Log into the equipment network management system via the local debug port to view the equipment operating status and alarm information, confirming there are no hardware alarms.
- Check the temperature, voltage, and current parameters of each equipment module for normalcy.
- Confirm the equipment software version meets requirements, and upgrade if necessary.
10.3.3 Lightning Protection System Performance Test
- Check the status indicator of the power surge protector for normalcy and no failure alarms.
- Test the continuity between the surge protector’s grounding terminal and the ground.
- If conditions permit, perform a surge simulation test to verify the surge protector operates correctly.
- Record the model, parameters, and installation location of the surge protector.
10.4 Antenna Azimuth and Tilt Calibration
10.4.1 Azimuth Calibration
- Measure the azimuth angle according to the planned design using a compass, inclinometer, or azimuth tester.
- Loosen the bracket’s azimuth locking bolts, slowly rotate the bracket to adjust to the design azimuth.
- Account for the magnetic declination and correct the measured values accordingly.
- After adjustment, lock the bolts and re-verify. A deviation ≤ ±2° is considered qualified.
10.4.2 Tilt Calibration
- Measure the antenna tilt angle using a clinometer or inclinometer according to the designed downtilt.
- Loosen the tilt adjustment bolts and adjust the antenna tilt angle to the design value.
- Combine mechanical and electrical downtilt adjustments to ensure the total downtilt meets requirements.
- After adjustment, lock the bolts and re-measure the angle. A deviation ≤ ±0.5° is considered qualified.
10.4.3 Antenna Position Re-check
- Check that the antenna mounting height meets design requirements, with an error ≤ 0.5m.
- Check that the spacing between antennas meets isolation requirements, with spacing ≥ 1m for co-system antennas and ≥ 2m for different systems.
- Check that there are no obvious obstructions around the antenna and no large metal obstacles in the main lobe direction.
10.5 Communication Performance Testing
10.5.1 VSWR Test
- Use a VSWR meter to test the Voltage Standing Wave Ratio (VSWR) of the antenna-feeder system at the near end of the feeder.
- The test frequency range should cover the equipment’s operating band. VSWR ≤ 1.5 across the entire band is considered qualified.
- If the VSWR is exceeded, troubleshoot the connectors, feeder cable, and antenna in sequence, locate the fault point, and resolve it.
- Record test frequency points and corresponding VSWR values to create a test curve.
10.5.2 Signal Coverage Test
- Select test points within the planned coverage area and use drive test terminals to measure Reference Signal Received Power (RSRP) and Signal to Interference plus Noise Ratio (SINR).
- Test the average RSRP and edge RSRP in the coverage area, ensuring they meet design coverage indicators (generally RSRP ≥ -105dBm for 5G coverage areas).
- Test the signal coverage range to ensure there are no obvious blind spots or weak coverage areas.
- If coverage does not meet standards, fine-tune the antenna azimuth and tilt angles to optimize the coverage effect.
10.5.3 Interference Test
- Test the base station’s noise floor to ensure it is within the normal range with no obvious elevation.
- Test intra-system and inter-system interference, checking for obvious intermodulation or spurious interference.
- Test handover relationships with neighboring base stations to ensure normal handovers with no handover failures or dropped calls.
- Investigate external interference sources and locate and resolve abnormal interference.
10.5.4 Transmission Performance Test
- Test the transmission link bandwidth, latency, and packet loss rate to ensure they meet service requirements.
- Perform ping tests with both long and short packets, confirming no packet loss and stable latency.
- Test uplink and downlink rates to meet the network design rate targets.
- Verify the remote network management monitoring function is working, allowing remote query of equipment status and parameter changes.
10.6 System Integration Commissioning
- Verify the base station connection to the core network is successful, the cell is established successfully, and users can access the network normally.
- Test voice, data, video, and other services for normal operation.
- Test the handover function: handovers between cells during movement should be normal, without dropped calls or disconnections.
- Test the alarm function: simulate faults to verify alarms are reported to the network management system normally.
- Test remote operations and maintenance functions such as remote restart and remote configuration.
10.7 72-Hour Continuous Trial Operation
- After all commissioning items pass, enter the 72-hour continuous trial operation phase.
- During the trial operation, the equipment remains in normal operating condition, continuously carrying services.
- Arrange personnel for regular inspections, recording equipment operating parameters, temperature, current, and alarm information.
- Monitor service indicators: call setup success rate, dropout rate, throughput, etc., ensuring they remain stable.
- Troubleshoot and resolve any faults or anomalies during the trial operation promptly. Restart the 72-hour clock after resolution.
- The commissioning is considered qualified if the 72-hour trial run completes without major faults and performance indicators are stable.
10.8 Commissioning Records and Reports
- Fill out commissioning record forms item by item during the process, recording test data, test times, and test personnel.
- Keep supporting evidence such as test screenshots, instrument test curves, and site photos.
- After commissioning is complete, prepare a formal commissioning report including project overview, commissioning basis, commissioning items, test results, issues and resolutions, and commissioning conclusions.
- The commissioning report must be signed and confirmed by all relevant parties and serve as acceptance and delivery documentation.
Chapter 11: Product Precautions
11.1 Installation Safety Precautions
- High-altitude workers must hold valid certifications and wear double-hook safety belts. Check the integrity of the safety belt before work and remain attached throughout the operation, hooking at a high point.
- Set up a warning zone below the work area with a dedicated monitor to keep unauthorized personnel out and prevent injury from falling objects.
- All tools must be tied to safety lanyards and placed in tool bags. Do not leave tools lying around and never throw tools or materials up or down.
- Immediately stop high-altitude work and evacuate personnel to the ground during severe weather such as winds of Force 6 or higher, thunderstorms, heavy fog, or ice/snow conditions.
- When using ladders or lifting platforms, ensure they are stable, assign a person to hold the ladder, and do not overload or allow two people to climb simultaneously.
- When installing clamps, be careful to prevent hand injuries. Tighten bolts evenly to prevent wrench slippage.
- When hoisting the bracket, secure it properly, lift slowly, and keep people away from underneath. Hold the bracket steady before connecting it.
- Always de-energize live poles before working on them. Verify no voltage before starting work. Climbing live poles is strictly prohibited.
11.2 Electrical Safety Precautions
- All electrical operations must be performed by certified electricians, strictly implementing the lockout/tagout procedures.
- Confirm the power supply is disconnected and verify no voltage with a test pen or multimeter before starting work.
- Do not damage the copper core when stripping cables. Strip the insulation to an appropriate length, avoiding excessive exposure.
- All wire connections must be securely crimped or soldered. Loose, twisted, or poor connections are strictly prohibited.
- Before powering up equipment, confirm the wiring is correct, especially DC polarity and AC phase lines, to prevent reverse connections.
- The grounding system must be reliably connected. Operating equipment without grounding is strictly prohibited to prevent electric shock.
- Outdoor wiring and commissioning work is forbidden during thunderstorms to prevent lightning strikes.
- If equipment leakage, abnormal heat, sparking, or odor is detected, immediately cut off power and investigate. Do not force power back on.
11.3 Structural Usage Precautions
- Use strictly according to the rated load. Installing equipment exceeding the rated load or modifying the bracket (e.g., extending the crossbeam, adding mounting points) without authorization is strictly prohibited.
- Do not hang heavy objects, climb, or step on the bracket. Do not use the bracket to pull or tow other objects.
- The bracket is intended for communication equipment within the design scope only. Do not modify its use for other purposes.
- Without manufacturer permission, cutting, welding, or modifying the bracket structure is strictly prohibited to avoid compromising the load-bearing system.
- Regularly check bolt tightness, especially after typhoons or heavy rains, and re-tighten any loose bolts promptly.
- If deformation, weld cracks, or severe corrosion is found on the bracket, stop using it immediately and contact professional personnel for assessment and handling.
- When replacing equipment, confirm the new equipment’s weight and dimensions are within the bracket’s compatibility range. Overweight equipment requires a bracket with a corresponding higher rating.
11.4 Anti-Corrosion Protection Precautions
- During transportation and installation, avoid impacts and scratches to the anti-corrosion coating. Repair any damage promptly with the appropriate touch-up paint.
- Avoid welding or gas cutting operations on the bracket to prevent burning the anti-corrosion coating.
- In highly corrosive environments such as coastal areas or chemical plants, increase inspection frequency and regularly check the anti-corrosion condition.
- Use neutral cleaning agents to clean the bracket. Strong acid or alkali cleaners that corrode the surface coating are strictly prohibited.
- When reinstalling bolts after removal, apply anti-rust grease to the threads to prevent corrosion and seizing.
- Regularly apply anti-rust grease to moving parts such as bolts and hinges to keep them flexible and rust-free.
11.5 Operation and Maintenance Precautions
- High-altitude maintenance work must be performed by two people: one worker and one supervisor. Working alone at heights is strictly prohibited.
- De-energize equipment before any maintenance work to prevent accidental contact with live parts.
- When adjusting antenna angles, make small, gradual adjustments. Forcing or prying is strictly prohibited to prevent bracket deformation or bolt breakage.
- Handle feeder cables and wires carefully during maintenance, avoiding hard bends or pulls to prevent connector loosening or cable breakage.
- After thunderstorms, promptly check equipment and bracket for water ingress. Dry any accumulated water and test insulation performance.
- During winter ice and snow conditions, promptly remove accumulated ice and snow from the bracket and equipment to prevent structural damage from excessive loading.
- After completing maintenance, restore all protective and sealing structures to ensure waterproof and dustproof performance.
11.6 Environmental and Surrounding Area Precautions
- Avoid selecting installation sites near flammable/explosive locations or areas with severely corrosive gases. Take special protective measures if necessary.
- Maintain sufficient safe distance from high-voltage power lines. For 10kV lines, the safety distance must be ≥ 1.5m.
- Avoid installing in locations prone to vehicle impact. If necessary, install anti-collision facilities.
- Pay attention to surrounding tree growth, as branches may rub against cables and equipment. Trim regularly to prevent damage from wind sway.
- During construction and maintenance, protect surrounding landscaping and municipal facilities, and repair any damage promptly.
Chapter 12: Product Maintenance and Repair
12.1 General Principles for Maintenance
- Establish a comprehensive equipment operation and maintenance ledger, recording information for each site’s bracket, including installation time, model/specifications, maintenance records, and fault handling.
- Adhere to the principle of “prevention first, combining maintenance and repair.” Conduct regular inspections and maintenance, identify potential issues promptly, and extend product service life.
- Strictly obey safety regulations during maintenance to ensure personnel and equipment safety.
- Spare parts and materials used for maintenance must be consistent with the original product specifications. Using unqualified substitutes is strictly prohibited.
- Major structural repairs must be carried out by professional technical personnel or under the guidance of the manufacturer’s technical support. Disassembling and repairing blindly is strictly prohibited.
12.2 Routine Inspection System
12.2.1 Inspection Frequency
- Monthly Inspection: Once a month, focusing on visual inspections of key road sections and high-value sites.
- Quarterly Inspection: Once a quarter, conducting comprehensive checks on structural fastening, anti-corrosion, grounding, and cables.
- Annual Inspection: Once a year, conducting full testing including torque re-verification, grounding tests, structural deformation measurements, and anti-corrosion assessment.
- Post-Severe Weather Inspection: Immediately conduct a special inspection after extreme weather events such as typhoons, heavy rain, blizzards, or earthquakes.
12.2.2 Monthly Inspection Content
- Observe the bracket assembly from a distance for any obvious tilting, deformation, or detachment.
- Observe the equipment for stable installation, without obvious tilting or looseness.
- Check cables for sagging, detachment, and intact labels.
- Check the base of the pole for severe corrosion or damage.
- Record inspection findings and schedule further checks if any anomalies are found.
12.2.3 Quarterly Inspection Content
- Closely inspect all bracket components for large areas of anti-corrosion coating peeling, blistering, or obvious rust.
- Visually inspect clamps and main connecting bolts, and spot-check torque on key bolts with a wrench.
- Check that cables are securely fixed, with no sheath damage or aging, and that waterproof seals are intact.
- Check the grounding down conductor connections for integrity, with no breakage or corrosion.
- Check equipment for secure installation, and connectors for looseness or signs of water ingress.
- Clean accumulated dust and debris from the bracket and equipment surfaces, and check drainage holes for blockage.
12.2.4 Annual Inspection Content
- Comprehensively check all structural bolts and re-tighten them all to the specified torque.
- Measure the bracket verticality and crossbeam horizontal levelness, comparing with initial values to assess any foundation settlement or structural deformation.
- Test grounding resistance to confirm compliance.
- Comprehensively inspect the anti-corrosion condition, performing rust removal and touch-up painting on corroded areas.
- Check cable aging conditions and test insulation performance.
- Check surge protector status, replacing any failed modules.
- Evaluate the overall structural safety of the bracket and propose maintenance recommendations for the following year.
- Issue an annual maintenance test report and archive it.
12.3 Routine Maintenance Items
12.3.1 Fastener Maintenance
- Every six months, apply anti-rust treatment to all exposed bolts, such as anti-rust grease or thread loosening agent.
- Annually, re-test the torque of key load-bearing bolts, re-tightening any that are loose to the specified value.
- Promptly replace badly corroded or thread-damaged bolts with stainless steel bolts of the same specification.
- Replace any failed spring washers or deformed flat washers simultaneously.
12.3.2 Anti-Corrosion Coating Maintenance
- If coating scratches or peeling are found with an area less than 100 cm², perform on-site repairs: grind to remove rust → clean → spray zinc-rich primer → spray matching topcoat.
- For larger corroded areas, develop a specific repair plan, thoroughly remove rust, and reapply the anti-corrosion coating.
- In coastal areas, apply a layer of anti-corrosion protective wax once a year to enhance performance.
- Focus inspection on weld joints, as they tend to corrode first. Treat promptly if rust appears.
12.3.3 Cable and Connector Maintenance
- Organize loose cables, re-bundle and secure them, and replace aged or broken cable ties.
- Inspect cable waterproof connectors, replacing aged seal rings and re-applying sealant as needed.
- Check feeder connector waterproofing, re-wrapping waterproof tape if it is cracked or peeling.
- Clean dust and oil stains from cable surfaces to keep sheaths clean.
12.3.4 Grounding System Maintenance
- Grind away oxide layers at grounding connection points, reapply conductive paste, and tighten bolts.
- De-rust and repaint corroded grounding down conductors, or replace them if severely corroded.
- Test grounding resistance annually, taking resistance-reduction measures if it exceeds the standard.
12.4 Repair Methods for Common Damages
12.4.1 Anti-Corrosion Coating Damage Repair
- Tools/Materials: Sandpaper, wire brush, rust remover, zinc spray, matching topcoat, brush.
- Repair Steps:
- Thoroughly grind the damaged area and surroundings with a wire brush and sandpaper to remove rust and loose coating, exposing bare metal. Feather the edges into a smooth transition.
- Clean away dust and oil with a cloth.
- Evenly spray 2 coats of zinc-rich primer, waiting 15 minutes between coats. The thickness should be no less than 40μm.
- After the primer dries, spray 2 coats of matching topcoat, ensuring even coverage without runs or missed spots.
- Allow 24 hours of natural drying before putting into service.
- Quality Requirements: The repaired area should be smooth, with no obvious color difference, and good adhesion.
12.4.2 Loose Bolt Repair
- If a loose bolt is found, first check whether the threads are corroded or damaged. If intact, re-tighten to the specified torque.
- Replace spring washers that have lost their elasticity before re-tightening.
- Replace bolts with stripped threads or breakage with new bolts of the same specification and material. Do not substitute with smaller bolts.
- If all clamp bolts are loose, causing the bracket to slide down, first lift the bracket back to its original height, clean the contact surfaces, then gradually tighten to the specified torque using the diagonal method.
12.4.3 Cable Sheath Damage Repair
- For minor sheath damage not exposing the copper core, wrap with at least 3 layers of insulating tape and reinforce with a heat-shrink tube.
- For severe damage exposing the copper core, cut the cable, re-crimp, ensure insulation and waterproofing, and place the connection in a waterproof junction box.
- For feeder cable outer sheath damage, replace the corresponding section of feeder or use a specialized feeder repair kit.
- For cables with severe aging or cracking, plan and execute complete replacement.
12.4.4 Minor Deformation Correction Repair
- Minor deformation of the crossbeam or vertical beam that does not affect load-bearing can be left as is, with enhanced monitoring.
- If deformation affects equipment installation, unload the equipment and use specialized tools for slow correction. Violent hammering is strictly prohibited.
- After correction, check for cracks in the component. Components with cracks must be replaced, and continued use is strictly prohibited.
- For severe structural deformation, replace the entire bracket. Do not attempt to repair and continue using it.
12.5 Major Issue Handling Procedure
- Upon discovering major structural hazards on the bracket such as severe tilting, weld cracks, or severe corrosion, immediately set up a warning area and prohibit personnel from approaching.
- Report to the maintenance supervisor and manufacturer’s technical support promptly, describing the on-site situation and sending photos.
- Have a professional structural engineer conduct a safety assessment and develop a repair or replacement plan.
- After plan approval, arrange for a professional team to implement the repair, with full supervision throughout to ensure safety.
- Organize an acceptance inspection after the repair. The bracket can only be returned to service after passing.
- Document the entire incident process, analyze the causes, and formulate preventive measures to avoid recurrence.
12.6 Spare Parts Management
- Establish a spare parts inventory, stocking commonly used wear parts: bolts, nuts, waterproof seal rings, cable glands, grounding terminals, anti-corrosion touch-up paint, etc.
- Stock a small quantity of complete brackets and major components for emergency replacement.
- Store spare parts in classified, labeled, moisture-proof, and rust-proof conditions. Conduct periodic inventory checks.
- Register spare part issues, replenish stocks promptly after use, ensuring emergency availability.
Chapter 13: Product Common Problems and Solutions
13.1 Structural Common Problems
| No. | Fault Phenomenon | Possible Cause Analysis | Solution |
|---|---|---|---|
| 1 | Bracket slides down overall, position moves lower | 1. Insufficient clamp bolt torque, inadequate friction; 2. Oil/dust on clamp interior, reduced friction coefficient; 3. Overloading | 1. Reset bracket, clean contact surfaces, re-tighten bolts to specified torque; 2. Replace anti-slip rubber pads; 3. Reduce load or use higher-capacity bracket |
| 2 | Bracket rotates around pole, azimuth offset | 1. Insufficient clamp tightening force; 2. Strong wind action exceeding torsional resistance; 3. Excessive wind-catching surface of equipment | 1. Readjust azimuth, tighten clamp bolts to rated torque; 2. Add an additional clamp to increase torsional resistance; 3. Optimize equipment installation angle to reduce windward area |
| 3 | Large crossbeam deflection, equipment sways noticeably | 1. Equipment overweight; 2. Diagonal support rod not installed or loose; 3. Normal phenomenon in strong wind | 1. Verify equipment weight, replace with larger bracket if overloaded; 2. Install or tighten diagonal support rod; 3. Minor wind-induced sway is normal, but excessive amplitude requires reinforcement |
| 4 | Connecting bolts loose | 1. Long-term wind vibration; 2. Spring washers not installed; 3. Initial torque insufficient | 1. Regularly re-tighten bolts, replace with anti-loosening washers; 2. Install spring washers; 3. Re-tighten to specified torque |
| 5 | Bracket local deformation | 1. Violent impact during installation; 2. Overloading; 3. External force impact | 1. Monitor minor deformation, replace components for severe deformation; 2. Overloading strictly prohibited; 3. Investigate impact source, install anti-collision facilities |
| 6 | Weld cracking | 1. Welding quality defects; 2. Long-term alternating load fatigue; 3. Corrosion weakening the cross-section | 1. Stop use, evaluate by professionals, weld-repair minor cracks, replace components for severe ones |
| 7 | Bracket overall tilting | 1. Light pole foundation settlement/tilting; 2. Incorrect clamp installation; 3. Excessive unilateral load | 1. Inspect pole foundation; address foundation issues first; 2. Re-adjust clamp installation; 3. Balance loads on both sides |
13.2 Anti-corrosion Common Problems
| No. | Fault Phenomenon | Possible Cause Analysis | Solution |
|---|---|---|---|
| 1 | Surface coating blistering, peeling | 1. Poor coating application quality; 2. Impact damage; 3. Corrosive media erosion | 1. Repair according to anti-corrosion repair procedure; 2. Avoid impacts during installation/maintenance; 3. Upgrade anti-corrosion plan for highly corrosive environments |
| 2 | Bolt corrosion seizing | 1. Bolt material substandard; 2. No anti-rust treatment; 3. Long-term outdoor exposure to rain | 1. Replace with stainless steel bolts; 2. Apply anti-rust grease; 3. Install bolt protective caps |
| 3 | Corrosion inside clamp | 1. Rainwater penetrates clamp gaps; 2. Anti-corrosion coating worn off on contact surfaces | 1. Disassemble, grind to remove rust, apply conductive anti-rust paste, reinstall; 2. Replace severely corroded clamps |
| 4 | Weld joints corrode first | 1. Inadequate corrosion protection at welds; 2. Stress concentration at welds makes them prone to corrosion | 1. Remove rust and apply zinc-rich paint and topcoat; 2. Regularly inspect weld areas as a priority |
| 5 | Faster corrosion rate in coastal areas | 1. Strong salt spray corrosion; 2. Insufficient standard anti-corrosion grade | 1. Use 316 stainless steel fasteners; 2. Add fluorocarbon topcoat; 3. Shorten inspection cycles, repair promptly |
13.3 Electrical and Lightning Protection Common Problems
| No. | Fault Phenomenon | Possible Cause Analysis | Solution |
|---|---|---|---|
| 1 | Grounding resistance exceeds standard | 1. Insufficient number of grounding electrodes; 2. High soil resistivity; 3. Loose/oxidized grounding connection wires | 1. Add grounding electrodes; 2. Use resistance-reducing agents or deep well grounding; 3. Grind terminals, apply conductive paste, tighten |
| 2 | Equipment enclosure electrified | 1. Equipment insulation damage causing leakage; 2. Grounding disconnected; 3. Neutral wire energized | 1. Cut power and investigate leakage point; 2. Repair ground connection; 3. Investigate neutral wire fault in power supply system |
| 3 | Equipment damaged after lightning | 1. Surge protector failure; 2. Poor grounding; 3. Poor equipotential bonding | 1. Replace damaged equipment and surge protector; 2. Rectify grounding system; 3. Improve equipotential bonding |
| 4 | Cable water ingress short circuit | 1. Waterproof connector seal failure; 2. Cable damage allowing water ingress; 3. No drip loop made | 1. Replace waterproof gland, reapply sealant; 2. Repair or replace cable; 3. Make drip loops for feeder and power cables |
| 5 | Frequent power trips | 1. Line short circuit, leakage; 2. Equipment failure causing overcurrent; 3. Breaker rating too small | 1. Investigate line insulation, address leakage points; 2. Inspect and repair equipment; 3. Replace with properly rated circuit breaker |
13.4 Common Signal Performance Issues
| No. | Fault Phenomenon | Possible Cause Analysis | Solution |
|---|---|---|---|
| 1 | Weak signal coverage, low RSRP | 1. Antenna azimuth and tilt angle deviation; 2. High antenna feeder VSWR; 3. New nearby buildings causing obstruction | 1. Recalibrate antenna angles; 2. Troubleshoot feeder faults and resolve VSWR; 3. Adjust antenna angle or increase installation height |
| 2 | Significant signal fluctuation, unstable | 1. Bracket sway causing antenna movement; 2. Loose feeder connector; 3. Nearby interference sources | 1. Reinforce bracket and reduce sway; 2. Tighten feeder connectors; 3. Locate and identify interference sources |
| 3 | VSWR alarm | 1. Feeder connector water ingress or oxidation; 2. Feeder bent or damaged; 3. Antenna failure | 1. Re-terminate connectors and apply waterproofing; 2. Replace damaged feeder section; 3. Test and replace antenna |
| 4 | Passive intermodulation interference | 1. Poor contact between metal components; 2. Bracket positioned too close to antenna; 3. Loose fasteners | 1. Ensure tight metal-to-metal contact and apply conductive grease; 2. Adjust installation position; 3. Tighten all bolts |
| 5 | Low transmission optical power | 1. Dirty fiber optic connector; 2. Excessive fiber bending; 3. High splice loss | 1. Clean fiber end faces; 2. Organize fiber and increase bend radius; 3. Re-splice high-loss points |
13.5 Common Installation and Construction Issues
| No. | Fault Phenomenon | Possible Cause Analysis | Solution |
|---|---|---|---|
| 1 | Clamp does not match light pole, large gap | 1. Error in light pole diameter measurement; 2. Wrong clamp size shipped | 1. Install adapter shims to adjust inner diameter; 2. Replace with clamp of correct specification |
| 2 | Difficult cable threading through pole | 1. Existing cables inside pole are disorganized; 2. Threading hole blocked; 3. Excessive number of cables | 1. Organize existing cables inside pole; 2. Clear the threading hole; 3. Optimize cable selection and reduce outer diameter |
| 3 | Equipment mounting holes do not match backplate | 1. Special equipment model with non-standard hole spacing; 2. Incorrect backplate hole pattern selected | 1. Customize an adapter plate; 2. Replace with backplate of matching hole spacing |
| 4 | Bracket not level after installation | 1. Light pole itself is not vertical; 2. Clamp installed incorrectly; 3. Component deformation | 1. Correct pole tilt first if pole is leaning; 2. Readjust clamp position; 3. Straighten or replace deformed components |
| 5 | Cable abrasion or sheath damage | 1. Burrs on threading hole; 2. Unsecured cable chafing from wind movement; 3. Cutting by sharp metal edges | 1. Deburr threading holes and install protective grommets; 2. Secure cables to reduce movement; 3. Add rubber protective sleeves at sharp edges |
14.1 Product Selection
Q1: How to choose the right light pole base station bracket model?
A: Selection is based on four key factors: â‘ Light pole diameter and cross-section type, to determine clamp specification; â‘¡ Weight and quantity of mounted equipment, to determine load rating; â‘¢ Installation environment (coastal/inland/industrial area), to determine corrosion protection level; â‘£ Whether special features are required (angle adjustment, multi-device installation, etc.). You may provide pole parameters, equipment parameters, and site conditions to our technical staff, and specialists will assist with the selection.
Q2: Can the bracket be installed on tapered light poles?
A: Yes. For tapered poles, measure the actual diameter at the installation position and select a clamp with the corresponding inner diameter. Dual-clamp or triple-clamp configurations are recommended to increase contact area and improve anti-slip and anti-torsion performance. For poles with significant taper, custom tapered clamps are recommended for better conformity.
Q3: Can circular clamps be used on square light poles?
A: Direct use is not recommended. Circular clamps have limited contact area with square poles, resulting in insufficient friction and a tendency to slip or rotate. Square poles should use dedicated flat-surface clamps that distribute force evenly across all four faces for reliable fixation. Our company can provide custom clamps for square, hexagonal, and other cross-section types.
Q4: Can multiple devices be installed on one bracket?
A: Yes. Our company offers dual-device, four-device, and other multi-mount models that can accommodate 2 to 4 AAU or RRU units simultaneously, supporting multi-operator co-location and infrastructure sharing. When selecting, ensure the total weight does not exceed the bracket’s rated load capacity.
Q5: Which is better, aluminum alloy or steel brackets?
A: Each has its advantages. Steel brackets offer high strength, large load capacity, and lower cost, making them suitable for conventional high-load scenarios. Aluminum alloy brackets are lightweight, corrosion-resistant, and aesthetically pleasing, ideal for light-load and high-aesthetic-requirement scenarios. Choose based on actual needs. For coastal high-corrosion environments, prioritize aluminum alloy or high-corrosion-resistant steel brackets.
14.2 Installation and Construction
Q6: What qualifications are required for installation?
A: Bracket installation falls within the scope of communication engineering construction. The construction unit must hold a Communication Engineering General Contracting qualification or corresponding municipal engineering construction qualification. Aerial workers must hold aerial work operation certificates, and electricians must hold electrician certificates.
Q7: How long does it take to install one bracket?
A: For an experienced crew using an aerial work platform, installation of a single standard bracket (excluding equipment wiring and commissioning) takes approximately 30 to 60 minutes. If equipment installation, wiring, and commissioning are included, a single site takes approximately 2 to 3 hours. Actual time is affected by installation height, working method, and site conditions.
Q8: Will installing a bracket deform a light pole with thin wall thickness?
A: Normally not. The clamp transmits pressure through surface contact, and local bearing capacity of the pole has been considered in the design. Standard clamp tightening force will not deform a compliant light pole. However, for thin-wall poles with wall thickness less than 2.5 mm, a bearing capacity verification is recommended. If necessary, install internal reinforcement rings at corresponding positions inside the pole.
Q9: Is on-site welding required?
A: No. This product features an all-bolted assembly structure. All connections are secured with bolts, eliminating on-site welding, which reduces construction safety risks and avoids damage to the corrosion protection coating.
Q10: What are the requirements for installation height?
A: Installation height is designed based on coverage requirements. For typical 5G micro base stations, an installation height of 6 to 10 meters is recommended. The installation position should avoid pole welds and diameter transition sections. Choose a straight section of the pole body with sufficient working space above and below. The minimum recommended installation height is no less than 3 meters to prevent vandalism and vehicle collision.
14.3 Performance and Safety
Q11: What typhoon strength can the bracket withstand?
A: Standard brackets are designed for Typhoon Level 12 (wind speed 35 m/s), while reinforced versions can withstand up to Level 15 (50 m/s). The design is based on local basic wind pressure values. For coastal areas with frequent typhoons, reinforced versions are recommended, along with shortened inspection intervals.
Q12: What is the service life of the bracket?
A: Under normal outdoor conditions, hot-dip galvanized plus powder-coated steel brackets have a design service life of over 20 years, while aluminum alloy brackets can reach over 25 years. Actual service life is affected by environmental corrosion levels and maintenance practices. Regular maintenance can effectively extend service life.
Q13: Will the bracket affect the safety of the light pole?
A: No. The bracket load is uniformly transferred to the pole through the clamp. A single bracket weighs only a few dozen kilograms, far below the pole’s design bearing capacity. As long as the pole structure is sound and the foundation is adequate, bracket installation will not affect the overall safety of the light pole.
Q14: Can lightning strike the equipment through the bracket?
A: The bracket itself is a conductor and will conduct lightning current during a strike. However, with proper grounding and lightning protection design, the lightning current will be rapidly discharged through the grounding system. Combined with power and signal surge protectors on the equipment side, the equipment can be effectively protected. Use without grounding is strictly prohibited.
Q15: Does the bracket affect the signal?
A: Minimal impact. The design avoids the antenna’s main radiation direction and uses a low-interference structure. With normal installation, signal attenuation is less than 0.5 dB and does not affect coverage. During installation, ensure metal components do not block the antenna’s front radiation direction.
14.4 Operation and Maintenance
Q16: How often should bolts be inspected?
A: Under normal conditions, retighten bolts 3 months after initial installation, then inspect every six months, with a comprehensive retightening annually. Special inspections are required after extreme weather events such as typhoons and rainstorms. In severely corrosive areas such as coastal or industrial zones, shorten the inspection interval to quarterly.
Q17: What should be done if the bracket rusts?
A: For minor rust spots, remove rust and touch up paint promptly to prevent spread. If the rusted area exceeds 30% or the depth exceeds 1/10 of the wall thickness, a structural safety assessment is required, and replacement may be necessary. Routine anti-corrosion maintenance can effectively prevent rust.
Q18: Can additional equipment be added to an existing bracket?
A: First verify the bracket’s rated load capacity. Additional equipment may be installed if the total weight after addition does not exceed the rated load. If overloaded, the bracket must be replaced with one of a higher load rating. Unauthorized overload use is strictly prohibited.
Q19: What if bolts are rusted and cannot be removed?
A: First apply penetrating oil and wait 30 minutes before attempting to loosen. If still stuck, use an angle grinder to cut off the nut and replace with new bolts. Never use excessive force, as this may cause bolt breakage inside the pole. Stainless steel bolts are recommended to prevent seizing.
Q20: Is it necessary to remove the bracket when replacing equipment?
A: No. Equipment is directly mounted on the installation backplate. To replace equipment, only remove the equipment mounting bolts. The bracket main body does not need to be dismantled, facilitating equipment upgrades.
14.5 Business Services
Q21: Is a warranty provided? How long?
A: Our products come with a 2-year warranty. During the warranty period, quality issues not caused by human factors are repaired or replaced free of charge. We also provide lifetime technical support and preferential spare parts supply.
Q22: Can brackets be customized to special specifications?
A: Yes. Our company supports customization services, including custom design and production based on special light pole dimensions, special equipment installation requirements, and special appearance requirements, meeting diverse personalized scenario needs.
Q23: Is on-site installation service available?
A: Yes. Our company has a professional construction team that provides nationwide integrated installation and commissioning services, as well as technical disclosure and on-site construction guidance.
Q24: How is the product packaged for shipping? Will it be damaged during transport?
A: Products are packaged with cartons and EPE foam cushioning. Large items are additionally reinforced with wooden frames. Normal transport will not cause damage. Please inspect goods upon delivery and promptly contact the logistics company and us if transport damage is found.
Q25: How to contact technical support?
A: Service Hotline: +86 13538869979 (also on WeChat), Technical Support: +86 13538869979. Staffed during working hours 8:30-18:00 on weekdays. Emergency issues receive a response within 2 hours.
15.1 General Acceptance Principles
The acceptance of light pole base station bracket projects is divided into four stages: factory acceptance, incoming material acceptance, subdivisional work acceptance, and final completion acceptance. Each stage must pass inspection before proceeding to the next process.
Acceptance is based on relevant national standards, industry specifications, design documents, construction contracts, and the technical requirements in this manual.
Acceptance is organized by the construction owner, with the participation of the construction unit, supervision unit, design unit, and equipment manufacturer, who jointly inspect and test item by item according to the acceptance procedures.
Acceptance must have complete records and signature procedures. Acceptance documentation must be archived for future reference.
Items that fail acceptance must be corrected within a specified period and re-inspected until they pass.
15.2 Factory Acceptance
Factory acceptance is conducted after production is completed and before shipment, executed by the supplier’s quality inspection department. The buyer may dispatch personnel for manufacturing supervision.
15.2.1 Inspection Items
Visual inspection: Component surfaces are smooth, free of cracks, deformation, and burrs. Corrosion protection coating is uniform and smooth, with no missed plating, runs, or peeling.
Dimensional inspection: Key dimensions conform to drawings, including beam length, column height, clamp inner diameter, mounting hole spacing, etc. Deviations are within tolerance ranges.
Material inspection: Verify steel and bolt material certificates conform to design requirements.
Coating thickness inspection: Use a thickness gauge to measure galvanized layer and powder coating thickness, meeting standard requirements.
Assembly inspection: Trial-assemble one unit. All components fit properly, bolt holes align, and adjustment mechanisms operate smoothly.
Documentation inspection: Product certificate, factory inspection report, material certificates, and other technical documents are complete.
15.2.2 Acceptance Criteria
Only when all inspection items pass is the factory acceptance deemed qualified. Products may be shipped only after the factory certificate of conformity is issued. For unqualified items, rework and re-inspect.
15.3 Incoming Material Acceptance
Incoming material acceptance is conducted after products arrive at the construction site, performed jointly by the construction unit and supervision unit.
15.3.1 Inspection Items
Packaging inspection: Packaging is intact, free of damage and water ingress.
Quantity verification: Count components, accessories, and tools against the packing list, ensuring completeness.
Visual inspection: No deformation, impact damage, or large-scale coating detachment during transport.
Specification verification: Product model and specification match the procurement contract and design documents.
Documentation inspection: Factory certificate, inspection report, and other documents are complete.
15.3.2 Acceptance Requirements
Products may be stored and used only after passing incoming material acceptance. Unqualified products shall be returned and not used in the project.
Complete the equipment and material incoming acceptance record with signatures from all parties.
15.4 Subdivisional Work Acceptance
After bracket installation and wiring are completed, subdivisional work acceptance is conducted before commissioning.
15.4.1 Bracket Installation Acceptance
| Inspection Item | Content and Requirements | Inspection Method |
|---|---|---|
| Installation position | Installation height deviation ≤ ±50 mm, horizontal azimuth deviation ≤ ±2° | Tape measure, compass |
| Verticality | Main column verticality ≤ 1‰ | Theodolite, spirit level |
| Levelness | Beam levelness ≤ 1 mm/m | Level gauge |
| Bolt tightening | All bolts tightened to specified torque, lock washers in place | Torque wrench spot check |
| Structural appearance | No deformation, cracks; coating intact; repaired areas smooth | Visual and tactile inspection |
| Equipment installation | Equipment securely fixed, tilt angle conforms to design, deviation ≤ ±0.5° | Inclinometer |
| Safety protection | No sharp edges, limit devices reliable, identification plates complete | Visual inspection |
15.4.2 Wiring Engineering Acceptance
| Inspection Item | Content and Requirements | Inspection Method |
|---|---|---|
| Cable routing | Cables neat and straight, securely banded, bend radius meets requirements, power and signal cables separated | Visual, tape measure |
| Wiring workmanship | Terminals crimped securely, wiring correct, no loose, wrong, or reversed connections | Visual, multimeter test |
| Insulation performance | Power cable insulation resistance ≥ 2 MΩ | Megger test |
| Grounding system | Grounding resistance ≤ 4 Ω, equipotential bonding reliable, grounding markings clear | Ground resistance tester |
| Waterproof sealing | Threading holes and connectors properly waterproofed, no water ingress risk | Visual, water spray test |
| Cable identification | Labels clear and accurate at both ends, content complete | Visual inspection |
15.5 Final Completion Acceptance
After system commissioning is completed and trial operation passes, final completion acceptance is conducted for handover and use.
15.5.1 Acceptance Documentation Verification
Complete completion documentation must be submitted before final acceptance, including:
- Project completion description and as-built drawings
- Product factory certificates, inspection reports, and material certificates
- Incoming material acceptance records
- Installation construction records and concealed work acceptance records
- Wiring test records
- Commissioning report and 72-hour trial operation records
- Grounding resistance test report
- Engineering change and negotiation records
- Supervision evaluation report
- Acceptance application form
15.5.2 On-site Sample Inspection
- Spot-check installation quality and wiring workmanship at a sample of sites, with a ratio of no less than 10% of total sites and no fewer than 3 sites.
- Spot-test key performance indicators: grounding resistance, VSWR, signal strength, power supply voltage, etc.
- Inspect appearance and overall effect, meeting landscape requirements.
- Verify business functions operate normally and all performance indicators meet design requirements.
15.5.3 Acceptance Conclusion
If all documentation is complete, physical quality is qualified, and performance indicators meet standards, the final completion acceptance is deemed qualified, and the completion acceptance certificate is signed.
For minor defects, rectify within a specified period. After rectification and re-inspection pass, sign the acceptance certificate.
For major quality issues affecting structural safety or functional use, acceptance is withheld. After rework, acceptance is re-organized.
15.6 Acceptance Handover
After acceptance passes, the construction unit handles the project handover procedures with the construction owner, transferring all project documentation and spare parts.
Clarify the warranty period and maintenance responsibilities, entering the warranty period operation and maintenance phase.
Provide technical disclosure to the operation and maintenance unit, including training on routine inspections and basic troubleshooting methods.
16.1 Keyword Classification System
16.1.1 Core Primary Keywords
- Light pole base station bracket
- Light pole base station mounting bracket
- Base station light pole bracket
- Communication light pole bracket
- 5G light pole bracket
16.1.2 High-Conversion Long-Tail Keywords
- Light pole base station bracket manufacturer
- 5G light pole base station bracket installation
- Communication base station light pole mounting bracket
- Street light pole base station mounting bracket
- Smart light pole base station bracket price
- Clamp-type light pole base station bracket
- Light pole base station bracket specifications
- Multi-function light pole base station bracket customization
16.1.3 Industry Traffic Keywords
- Base station bracket installation specifications
- Communication base station bracket technical requirements
- 5G micro base station light pole deployment
- Smart light pole base station construction solution
- Light pole base station construction technology
- Base station bracket acceptance standards
- Communication tower equipment bracket
- Outdoor base station bracket anti-corrosion requirements
16.1.4 Brand-Specific Keywords
- Lai’an light pole base station bracket
- Guangdong Lai’an base station bracket
- Lai’an smart light pole bracket
- Guangzhou light pole base station bracket manufacturer
- Lai’an base station support equipment
16.1.5 Dropdown/Related Search Keywords
- How to install a light pole base station bracket
- How much does a light pole base station bracket cost
- What is the load capacity of a light pole base station bracket
- How to do lightning protection for a light pole base station bracket
- Wind resistance rating of light pole base station bracket
- Can a street light pole be fitted with a base station bracket
- Base station bracket installation and wiring tutorial
- Common faults of light pole base station brackets
16.2 SEO Optimization Tag System
16.2.1 Page Core Optimization Tags
Page theme: Light Pole Base Station Bracket Installation, Wiring, and Commissioning Manual — Manufacturer Technical Guide
Keyword density: Core primary keywords naturally distributed, density controlled at 2% to 3%
Content length: Long-form technical document to meet in-depth content indexing requirements
Semantic coverage: Cover the full semantic flow of product selection, installation, wiring, commissioning, maintenance, and acceptance
16.2.2 Title Tag
Light Pole Base Station Bracket Installation, Wiring, and Commissioning Manual_5G Communication Base Station Light Pole Bracket Technical Specifications_Guangdong Lai’an Smart Equipment Room Equipment Co., Ltd.
16.2.3 Meta Keywords
Light pole base station bracket, light pole base station mounting bracket, 5G light pole bracket, communication base station bracket, smart light pole base station bracket, clamp-type base station bracket, base station bracket installation, base station bracket wiring and commissioning, Lai’an base station bracket
16.2.4 Meta Description
Guangdong Lai’an Smart Equipment Room Equipment Co., Ltd. professionally provides light pole base station brackets. This manual details the product introduction, component structure, technical parameters, installation process, wiring specifications, commissioning methods, maintenance, troubleshooting, and acceptance standards for light pole base station brackets. Suitable for 5G micro base station smart light pole deployment, featuring safe and reliable structure and efficient installation.
16.2.5 H1 Tag
Light Pole Base Station Bracket Installation, Wiring, and Commissioning Manual
16.2.6 H2 Tags
- Product Introduction
- Product Composition
- Product List
- Product Working Principle
- Product Technical Parameters
- Product Functions and Features
- Product Application Scenarios
- Product Installation Process
- Product Wiring Specifications
- Product Commissioning Process
- Product Precautions
- Product Repair and Maintenance
- Product Common Problems and Solutions
- Product Q&A
- Product Acceptance Standards
16.3 Internal Link Optimization Tags (Natural Anchor Text Placement)
16.3.1 Core Anchor Texts
- Light pole base station bracket
- 5G light pole bracket
- Communication base station bracket
16.3.2 Long-Tail Anchor Texts
- Light pole base station bracket installation method
- Base station bracket wiring and commissioning tutorial
- Smart light pole base station construction solution
- Communication base station bracket technical specifications
16.3.3 Related Anchor Texts
- Micro-module cold aisle containment
- Shielded machine room construction
- Intelligent constant temperature cabinet
- Outdoor integrated cabinet
- Liquid cooling heat dissipation system
17.1 Copyright Statement
This “Light Pole Base Station Bracket Installation, Wiring, and Commissioning Manual” is copyrighted by Guangdong Lai’an Smart Equipment Room Equipment Co., Ltd. and is protected by national copyright law.
No entity or individual may reproduce, repost, excerpt, alter, compile, distribute, or use the content of this manual in any form or for commercial purposes without written authorization from our company.
Authorized reposting or citation must indicate the source “Source: Guangdong Lai’an Smart Equipment Room Equipment Co., Ltd.” and must not distort, delete, or modify the content.
Our company reserves the right to pursue legal liability for infringement.
This manual will be continuously updated with product technology upgrades. The latest version as officially released shall prevail. No separate notice will be provided.
17.2 Manufacturer Information
Manufacturer: Guangdong Lai’an Smart Equipment Room Equipment Co., Ltd.
Service Hotline: +86 13538869979 (also on WeChat)
Technical Support: +86 13538869979
Address: Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou
Website: gdlain.com