Table of Contents
ToggleChapter 1 Product Introduction
1.1 Product Overview
The Vulnerability Scanning and Repair System is a new-generation network security protection core device independently developed by Guangzhou Lain Intelligent System Development Co., Ltd. It integrates asset discovery, vulnerability detection, risk assessment, patch repair, and compliance audit into one unified platform, serving as an indispensable proactive defense device in enterprise-level network security protection systems. The system adopts a distributed scanning engine architecture, combined with cloud threat intelligence and local vulnerability signature databases, enabling comprehensive, multi-dimensional vulnerability detection across all asset categories within the network, including servers, terminals, network devices, security devices, databases, web applications, and industrial control systems. It accurately identifies known vulnerabilities, weak passwords, configuration defects, compliance risks, and other security hazards, while providing automated repair solutions and hardening recommendations to achieve a closed-loop security management cycle of “Discovery – Assessment – Repair – Verification.”
This product strictly complies with national laws, regulations, and industry standards including the *Cybersecurity Law of the People’s Republic of China*, *Information Security Technology – Baseline for Cybersecurity Classified Protection*, and the *Data Security Law of the People’s Republic of China*. It is widely applicable to government, finance, education, medical, energy, transportation, telecommunication operators, and industrial control sectors, effectively helping users reduce network attack surface, improve overall security protection levels, and meet multiple business requirements including classified protection assessment, compliance audit, and routine security operations.
1.2 Product Positioning
The Vulnerability Scanning and Repair System is positioned in the dual role of “scout” and “repair technician” within an enterprise-level proactive network security defense system — it is both a discoverer of security risks and a solver of security problems. Traditional vulnerability scanning products can only complete vulnerability detection and report output, unable to form a complete security closed-loop. This system, based on precise scanning, integrates core capabilities such as automated patch pushing, batch repair, and repair effectiveness verification, upgrading vulnerability management from “passive discovery” to “proactive governance,” significantly reducing the workload of security operations personnel and improving vulnerability remediation efficiency.
Within the overall network security architecture, the Vulnerability Scanning and Repair System operates at the front-end stage of security protection. It can identify and eliminate security hazards before attackers exploit vulnerabilities to launch attacks, serving as an important complement to perimeter defense devices such as firewalls, intrusion detection systems, and antivirus solutions, thereby constructing a defense-in-depth architecture of “perimeter defense + internal governance.”
1.3 Product Value
1.3.1 Security Value
- Comprehensive Risk Awareness: Full-dimension vulnerability detection covering network layer, system layer, application layer, and data layer, leaving no detection blind spots, helping users fully grasp the network security posture.
- Proactive Risk Remediation: Completing repairs before vulnerabilities are exploited, containing security risks at their inception, effectively reducing the probability of security incidents such as ransomware, data leakage, and website defacement.
- Closed-Loop Security Management: Full-process closed-loop management from asset inventory, vulnerability scanning, risk assessment, repair execution to effectiveness verification, solving the pain point of traditional vulnerability management that “only scans but never repairs.”
1.3.2 Management Value
- Improved Operations Efficiency: Automated scanning and batch repair functions replace traditional manual per-device detection and manual patching, improving operations efficiency by over 80%.
- Quantified Security Outcomes: Multi-dimensional visual reports and trend analysis make security governance results quantifiable and traceable, providing data support for security decision-making.
- Reduced Labor Costs: Reduces time investment of security operations personnel in repetitive work, allowing professionals to focus on higher-value security planning and in-depth protection work.
1.3.3 Compliance Value
- Classified Protection Compliance: Fully meets the requirements of Cybersecurity Classified Protection 2.0 standards regarding vulnerability scanning, security management and control, and vulnerability management, helping users pass classified protection assessments smoothly.
- Industry Standards Compliance: Supports special security baseline checks for finance, power, medical, education, and other industries, meeting security audit requirements of industry regulatory authorities.
- Audit Evidence Retention: Complete logging of scanning tasks, repair operations, result reports, and other full-process records, satisfying security audit and traceability requirements.
1.4 Product Development History
Guangzhou Lain Intelligent System Development Co., Ltd. has been deeply engaged in the network security field for over a decade. The Vulnerability Scanning and Repair System has undergone multiple generations of technological iteration, evolving from an initial single port scanning tool into a comprehensive vulnerability management platform integrating multiple functions.
- First Generation: Basic port scanning and system vulnerability detection, supporting patch missing detection for common operating systems.
- Second Generation: Added web application scanning and database vulnerability detection, supporting weak password brute-force testing and baseline configuration checks.
- Third Generation: Integrated automated repair functionality, achieving integrated vulnerability scanning and repair, supporting distributed deployment and multi-level cascading.
- Fourth Generation (Current Version): Introduced AI intelligent analysis and cloud threat intelligence, reducing false positive rates, supporting new scenarios such as industrial control systems, cloud environments, and containers, with the vulnerability database exceeding 150,000 entries.
Chapter 2 Product Composition
2.1 Hardware Composition
The Vulnerability Scanning and Repair System adopts a standard rack-mount hardware architecture. Hardware configurations vary by model and specification. Core hardware components include:
2.1.1 Main Control Unit
- High-Performance Processor: Uses domestic Hygon/Phytium processors or Intel Xeon series processors with multi-core, high-concurrency processing capability, supporting parallel execution of multiple scanning tasks.
- Memory Module: Equipped with ECC-verified memory to ensure long-term stable system operation. Memory capacity ranges from 16GB to 256GB depending on model.
- Storage Unit: SSD solid-state drive as system disk, paired with large-capacity HDD or SSD as data disk for storing vulnerability databases, scan logs, report files, and other data.
- Motherboard and Chipset: Industrial-grade server motherboard supporting hardware redundancy design, featuring high reliability and stability.
2.1.2 Network Interface Unit
- Management Port: 1 Gigabit RJ45 copper port for device web management, system configuration, and upgrade maintenance.
- Scanning Copper Ports: 4–16 Gigabit/10-Gigabit RJ45 copper ports for connecting to business networks, executing vulnerability scanning tasks and patch pushing.
- Scanning Optical Ports: 2–8 SFP+ 10-Gigabit optical ports, suitable for high-traffic core network environments, supporting long-distance fiber connectivity.
- HA Interface: Some high-end models support dual-machine hot-standby interface for high-availability deployment.
- Serial Port: 1 RJ45-type Console port for command-line mode device initialization and troubleshooting.
2.1.3 Power and Cooling Unit
- Power Module: Standard single power supply; high-end models support 1+1 redundant power supply with AC 100–240V wide-range voltage input, adapting to different power environments.
- Cooling System: Intelligent temperature-controlled fan array that automatically adjusts fan speed based on internal device temperature, balancing cooling efficiency and noise reduction.
- Chassis Structure: Standard 1U/2U/4U rack-mount chassis made of high-quality galvanized steel sheet, providing good electromagnetic shielding and mechanical strength.
2.1.4 Front Panel Components
- Status Indicator Lights: Includes power light, operation light, alarm light, and per-port link lights and data lights, providing intuitive display of device operation status.
- LCD Display: Mid-to-high-end models feature a front LCD panel for viewing device IP address, CPU/memory utilization, system version, and other basic information.
- USB Interface: 2 USB 3.0 ports for connecting external storage devices for system backup, upgrade, and log export.
2.2 Software Composition
The system software adopts a modular design, with each functional module operating independently and collaborating together, ensuring system stability and scalability.
2.2.1 Operating System Layer
Uses a customized, security-hardened Linux operating system kernel with unnecessary system services stripped, high-risk ports closed, and strict access control policies configured, ensuring device self-security at the foundational level. The system holds independent intellectual property rights, supports domestic operating system adaptation, and meets Xinchuang (indigenous innovation) environment deployment requirements.
2.2.2 Core Engine Layer
- Asset Discovery Engine: Supports multiple host discovery technologies including ICMP, ARP, TCP SYN, and UDP, rapidly identifying live assets in the network and automatically recognizing device type, operating system, open ports, running services, and other information.
- Port Scanning Engine: Supports full port scanning and designated port scanning, utilizing stateless scanning technology to ensure scan speed while reducing impact on target networks.
- Vulnerability Detection Engine: Core system module, based on multiple detection technologies including signature matching, protocol interaction, and POC verification, accurately identifying various security vulnerabilities.
- Web Scanning Engine: Integrates intelligent crawlers and web vulnerability detection plugins, supporting detection of common web vulnerabilities including SQL injection, XSS cross-site scripting, file upload, and command execution.
- Baseline Verification Engine: Built-in multiple compliance baseline templates for checking configuration security of operating systems, databases, and network devices.
- Weak Password Detection Engine: Supports weak password brute-force detection for multiple protocols, with built-in common password dictionaries and support for custom dictionary import.
- Repair Execution Engine: Responsible for patch download, distribution, installation, and verification, supporting batch repair and scheduled repair, with resume capability and exception rollback.
2.2.3 Data Management Layer
- Vulnerability Signature Database: Contains vulnerability signatures published by authoritative organizations including CVE, CNVD, and CNNVD, covering operating systems, application software, network devices, web applications, and other fields, with regular updates.
- Patch Database: Stores official security patches from various vendors, supporting offline patch import and online synchronization.
- Asset Database: Stores basic information of all scanned assets, historical scan records, vulnerability status, and other data.
- Log Database: Records full-process data including system operation logs, scan task logs, and repair execution logs.
2.2.4 Management Interface Layer
- Web Management Platform: Adopts B/S architecture, accessible via browser without client installation, featuring Chinese interface with simple and intuitive operations.
- Role and Permission Management: Supports multiple roles including super administrator, system administrator, security auditor, and regular user, with fine-grained permission allocation.
- Visualization Display: Provides Dashboard dashboards presenting asset counts, vulnerability distribution, risk trends, and repair progress in chart form.
- Report Management: Supports report generation and export in multiple formats, with customizable report templates and display content.
2.2.5 Interface Service Layer
- RESTful API Interface: Provides standardized API interfaces supporting integration with third-party security platforms, operations management systems, and SOC platforms.
- Syslog Interface: Supports sending system logs and alarm information to third-party log servers or SIEM systems.
- SNMP Interface: Supports SNMP protocol for integration into network management platforms for device status monitoring.
Chapter 3 Product Classification
3.1 Classification by Hardware Specification
3.1.1 Entry-Level Series
- Representative Models: LA-VS-100
- Applicable Scenarios: Small and medium-sized enterprises, branch offices, small office networks
- Hardware Configuration: 1U rack-mount, 4-core processor, 16GB memory, 1TB storage, 4 Gigabit copper ports
- Performance Parameters: Maximum concurrent scanning IPs: 50; daily scanning IPs ≤500; vulnerability database ≥80,000 entries
- Functional Features: Basic vulnerability scanning, weak password detection, standard report output, manual repair guidance support
3.1.2 Enterprise Series
- Representative Models: LA-VS-300, LA-VS-500
- Applicable Scenarios: Medium-sized enterprises, campus networks, district-level organizations, Level 2 classified protection systems
- Hardware Configuration: 2U rack-mount, 8–16 core processor, 32–64GB memory, 2–4TB storage, 8 Gigabit copper ports + 2 10-Gigabit optical ports
- Performance Parameters: Maximum concurrent scanning IPs: 200–500; daily scanning IPs: 2000–5000; vulnerability database ≥120,000 entries
- Functional Features: Full-feature vulnerability scanning, web application scanning, database scanning, baseline verification, automated patch repair, distributed scan node management
3.1.3 High-End Flagship Series
- Representative Models: LA-VS-800, LA-VS-1000
- Applicable Scenarios: Large enterprises, telecom operators, provincial-level organizations, Level 3+ classified protection systems, large data centers
- Hardware Configuration: 2U/4U rack-mount, 16–32 core processor, 128–256GB memory, 8–16TB storage, 16 Gigabit copper ports + 8 10-Gigabit optical ports
- Performance Parameters: Maximum concurrent scanning IPs: 1000–2000; daily scanning IPs: 10000–20000; vulnerability database ≥150,000 entries
- Functional Features: Full feature coverage, multi-level cascading management, dual-machine hot-standby, cloud intelligence integration, AI intelligent false positive filtering, industrial control system special scanning, customized development support
3.1.4 Domestic (Xinchuang) Series
- Representative Models: LA-VS-G200, LA-VS-G600
- Applicable Scenarios: Party and government agencies, classified units, Xinchuang industrial parks, domestic substitution projects
- Hardware Configuration: Uses domestic Hygon/Phytium processors, domestic firmware and storage, full-stack localization adaptation
- System Support: Compatible with Kylin, UOS, and other domestic operating systems, supporting domestic database adaptation
- Qualification Certifications: Possesses relevant national security qualification certifications, meeting classified information system deployment requirements
3.2 Classification by Deployment Form
3.2.1 Hardware Appliance
Integrates scanning engine, management platform, vulnerability database, and patch database entirely into dedicated hardware appliances. Plug-and-play, simple deployment, and easy maintenance make this the preferred form for the majority of users. Hardware appliances offer stable performance and high security, suitable for enterprise environments with high reliability requirements.
3.2.2 Virtualized Version
Released as virtual machine images, supporting deployment on mainstream virtualization platforms including VMware, KVM, and Hyper-V. Users can flexibly allocate computing resources based on actual needs. The virtualized version saves hardware costs and facilitates unified resource scheduling, suitable for cloud data centers and virtualized environments.
3.2.3 Cloud-Native Version
Specifically designed for cloud computing environments, supporting containerized deployment on public cloud platforms including Alibaba Cloud, Tencent Cloud, and Huawei Cloud, as well as private cloud and hybrid cloud environments. The cloud-native version supports elastic scaling, dynamically adjusting resources based on scan task volume, adapting to the dynamic change characteristics of cloud assets.
3.2.4 Distributed Probe Version
Consists of a central management platform and distributed scanning probes deployed in different network zones, uniformly managed and scheduled by the central platform. Suitable for large networks with cross-region, multi-branch structures, solving cross-subnet scanning and network isolation environment scanning challenges, supporting hierarchical deployment and data aggregation.
3.3 Classification by Functional Focus
3.3.1 Comprehensive Vulnerability Scanning Type
General-purpose product covering all categories of detection including host vulnerabilities, network device vulnerabilities, web vulnerabilities, database vulnerabilities, weak passwords, and baseline configuration. Suitable for most general scenarios.
3.3.2 Web Application Specialized Type
Focuses on web application security detection with stronger web crawler capability and deeper vulnerability detection depth. Supports advanced features including API scanning, authenticated scanning, and business logic vulnerability detection. Suitable for website clusters, internet application systems, and similar scenarios.
3.3.3 Industrial Control System Specialized Type
Designed for industrial control systems, supporting vulnerability detection for industrial control devices including PLC, SCADA, DCS, and industrial switches. Uses low-impact scanning strategies to avoid interference with industrial control systems. Suitable for power, petroleum, chemical, manufacturing, and other industrial control scenarios.
3.3.4 Compliance Audit Specialized Type
Features rich built-in compliance baseline templates, focusing on security configuration verification and compliance auditing. Supports compliance checks against multiple standards including Classified Protection 2.0, ISO27001, PCI-DSS, and industry regulatory specifications. Suitable for users with specific compliance requirements.
Chapter 4 Product Checklist
4.1 Standard Packing List
Upon receiving the device, please check the completeness of items against the following list. If anything is missing or damaged, please contact our company promptly.
| No. | Item Name | Quantity | Remarks |
|---|---|---|---|
| 1 | Vulnerability Scanning and Repair System host | 1 unit | Specific model per purchase order |
| 2 | AC power cable | 1–2 pcs | Redundant power models include 2 pcs |
| 3 | Gigabit network cable | 1 pc | For initial configuration management |
| 4 | Console configuration cable | 1 pc | RJ45 to RJ45 serial cable |
| 5 | Rack mounting ears | 1 pair | Including mounting screws |
| 6 | Product Quick Start Guide | 1 copy | Printed version |
| 7 | Product certificate of conformity | 1 copy | — |
| 8 | Warranty card | 1 copy | — |
| 9 | USB key | 1 pc | Standard on select models, used for license authentication |
4.2 Optional Accessories List
The following accessories require separate ordering and can be selected based on actual needs:
| No. | Accessory Name | Applicable Models | Description |
|---|---|---|---|
| 1 | Redundant power module | Mid-to-high-end models | 1+1 redundant power supply, improving device reliability |
| 2 | 10-Gigabit optical module | Models with optical ports | SFP+ single-mode/multi-mode optical module |
| 3 | Distributed scanning probe | Enterprise level and above | For expanding scan coverage, deployed in branch networks |
| 4 | Offline upgrade package USB drive | All series | Stores vulnerability database and system offline upgrade files |
| 5 | Industrial sliding rails | All series | Server cabinet dedicated sliding rails |
| 6 | 4G remote management module | Special customization | Supports remote operations and maintenance without external network connectivity |
4.3 Software License List
System software licenses are divided into basic licenses and value-added feature licenses. Specific license items are as follows:
4.3.1 Basic License
- System Platform License: Permanent usage right of device operating system and basic management platform.
- Vulnerability Database Basic License: Includes basic system vulnerabilities, network device vulnerabilities, and weak password detection database.
- Scanning IP License: Tiered by concurrent scanning IP count, such as 50IP, 100IP, 500IP, 1000IP, etc.
- One-Year Standard Service: Includes one year of vulnerability database updates, system upgrades, and technical support services.
4.3.2 Value-Added License
- Web Application Scanning License: Activates web specialized scanning engine and web vulnerability database.
- Database Scanning License: Activates in-depth vulnerability detection for mainstream databases.
- Automated Repair License: Activates patch automatic distribution and batch repair functions.
- Baseline Verification License: Unlocks all compliance baseline templates and custom baseline functions.
- Distributed Cascading License: Supports multi-level cascading management and distributed probe access.
- Cloud Intelligence License: Connects to cloud threat intelligence, supporting real-time vulnerability alerts and intelligence integration.
- Industrial Control Scanning License: Activates industrial control system specialized scanning plugins and vulnerability database.
Chapter 5 Product Principles
5.1 Basic Principles of Vulnerability Scanning
The core logic of vulnerability scanning is to simulate hacker attack detection behavior by sending specially constructed probe packets to target systems, then matching the vulnerability signature database based on the target system’s response to determine whether the target has corresponding security vulnerabilities. The entire process follows the principle of “non-destructive detection,” completing testing without affecting normal operation of target systems.
5.1.1 Host Discovery Principles
Before formal scanning, the system must first identify live hosts within the target subnet. Common technologies include:
- ICMP Ping Scan: Sends ICMP Echo Request packets and determines host liveness based on whether an Echo Reply is received. Fast but easily blocked by firewalls.
- ARP Scan: Sends ARP request packets, suitable for host discovery within the same LAN, high accuracy, and not restricted by firewalls.
- TCP SYN Scan: Sends TCP SYN packets to common ports; if a SYN+ACK response is received, the host is determined to be live. Can penetrate some firewalls.
- UDP Scan: Sends probe packets to UDP ports, determining host status based on ICMP port unreachable packets or application responses.
The system comprehensively applies multiple detection technologies to improve host discovery accuracy and completeness, avoiding omission of live assets.
5.1.2 Port Scanning Principles
Port scanning is used to detect which TCP/UDP ports are open on target hosts, as well as the service types and versions corresponding to those ports, serving as the foundation of vulnerability scanning. Common scanning technologies:
- TCP Full Connect Scan: Completes the full TCP three-way handshake. Accurate results but slow, easily recorded in target system logs.
- TCP SYN Half-Open Scan: Sends only SYN packets and does not establish a complete connection after receiving SYN+ACK. Fast, good stealth, and the most commonly used scanning method.
- TCP FIN/Xmas/Null Scan: Exploits implementation differences in TCP protocol stacks for detection. Stronger stealth, suitable for evading firewall detection.
- UDP Scan: Sends UDP data packets, determining port status based on ICMP unreachable packets or application-layer responses. Slower speed.
Based on port identification, the system sends service fingerprint probe packets, matches the service signature database, and identifies the service type (e.g., HTTP, FTP, SSH), software name, and specific version number corresponding to the port, providing the basis for subsequent vulnerability detection.
5.1.3 Vulnerability Detection Principles
Based on different vulnerability types and detection methods, vulnerability detection is mainly divided into the following technical categories:
Version Comparison Method
This is the most basic vulnerability detection method. After identifying the operating system version and application software version of target systems, the system compares them against vulnerable version numbers in the vulnerability database. If the target version falls within the affected range, the corresponding vulnerability is determined to exist. This method is fast and has no impact on the target, but cannot verify whether the vulnerability actually exists and may produce false positives. Suitable for rapid screening of system patch vulnerabilities and software version vulnerabilities.
Signature Matching Method
The system sends specially constructed probe requests to targets, analyzes characteristics of response packets such as status codes, returned content, response headers, and error messages, then matches them against the vulnerability signature database to determine vulnerability existence. This method is more accurate than version comparison and has minimal impact on target systems. It is a common technique for web vulnerability and application-layer vulnerability detection.
POC Verification Method
For certain vulnerabilities that can be safely verified, the system constructs harmless verification code (Proof of Concept), executes it on target systems, and observes results to confirm the vulnerability actually exists. For example, constructing special SQL statements to verify SQL injection vulnerabilities, or executing simple system commands to verify command execution vulnerabilities. This method has the highest accuracy and lowest false positive rate, but has slight impact on target systems and must be used within authorized scope.
Authenticated Scan Method
By obtaining legitimate account credentials for target systems, the system logs into the system for in-depth detection, such as checking system patch installation status, registry configurations, file permissions, and local security policies. This method provides the most comprehensive and accurate detection, able to identify many local vulnerabilities and configuration issues that remote scanning cannot discover. However, it requires account passwords for target systems and is suitable for in-depth scanning of authorized intranet environments.
5.2 Basic Principles of Vulnerability Repair
The vulnerability repair system is based on patch management technology to achieve automated vulnerability repair. Core principles are as follows:
5.2.1 Patch Matching Principles
After scanning is complete, the system correlates and matches identified vulnerabilities with the patch database, with each vulnerability corresponding to one or more official repair patches. The system automatically filters adapter-compatible patch files based on target system’s operating system version, language version, and architecture type (32-bit/64-bit), avoiding compatibility issues caused by incorrect patch installation. For vulnerabilities requiring prerequisite patches, the system automatically identifies dependency relationships and installs in the correct order.
5.2.2 Patch Distribution Principles
The system supports both online and offline patch distribution modes:
- Online Mode: The device connects directly to the internet, downloads patch files from vendor official servers or our company’s cloud patch server, and distributes them to intranet target hosts.
- Offline Mode: Users manually download patch upgrade packages, import them into the system patch database, and then perform intranet distribution. Suitable for physically isolated classified networks.
Patch distribution uses resume technology with multi-threaded concurrent transmission to improve distribution efficiency. The transmission process supports checksum verification to ensure patch file integrity and prevent file corruption.
5.2.3 Repair Execution Principles
The system achieves automated patch installation by remotely invoking the patch installation interface of target systems. For Windows systems, patch installation programs are remotely executed via protocols including WMI, WinRM, and SMB. For Linux systems, package management commands such as yum and apt are executed via SSH protocol for patch updates.
The repair execution process supports the following strategies:
- Batch Execution: Executing repair tasks on multiple hosts simultaneously for improved efficiency.
- Scheduled Execution: Setting automatic execution during business off-peak hours (e.g., nighttime) to avoid impacting business operations.
- Gradual (Canary) Execution: First executing on a small-scale test machine, then rolling out at scale after verification.
- Exception Rollback: Some patches support rollback after installation, allowing rapid recovery if compatibility issues arise.
5.2.4 Repair Verification Principles
After patch installation is complete, the system automatically performs a second scan of target hosts to verify whether vulnerabilities have been successfully repaired. It simultaneously checks target system operation status and service availability to confirm patches have not negatively impacted business operations. Verification results are recorded in the system, forming a complete repair closed-loop.
5.3 Overall System Workflow
The complete workflow of the Vulnerability Scanning and Repair System is divided into six phases:
1. Asset Inventory Phase: Import or automatically discover target assets, perform asset classification and labeling management, and establish an asset ledger.
2. Policy Configuration Phase: Configure scanning policies based on business requirements and scanning scenarios, including scan scope, scan type, scan intensity, and scan schedule.
3. Scan Execution Phase: Start scan tasks according to preset policies; the engine automatically completes host discovery, port scanning, vulnerability detection, and information collection.
4. Analysis and Assessment Phase: The system analyzes scan results, removes false positives, performs risk rating according to CVSS standards, and generates risk assessment reports.
5. Repair Execution Phase: Develop repair plans based on assessment results, execute patch distribution and installation, and track repair progress.
6. Verification and Archiving Phase: Perform re-testing and verification of repair results, generate final security reports, archive scan and repair records, and enter the next cycle.
Chapter 6 Product Technical Parameters
6.1 Hardware Technical Parameters
The following are common hardware parameters for the full product series. Specific model parameters are subject to product brochures.
6.1.1 Overall Machine Parameters
| Parameter | Specification |
|---|---|
| Chassis Specification | Standard 19-inch rack-mount, 1U/2U/4U height |
| Chassis Material | SECC high-quality galvanized steel sheet |
| Operating Temperature | 0°C ~ 45°C |
| Storage Temperature | -20°C ~ 70°C |
| Operating Humidity | 10% ~ 90%, non-condensing |
| Storage Humidity | 5% ~ 95%, non-condensing |
| Power Input | AC 100~240V, 50/60Hz |
| Maximum Power | 1U model ≤300W, 2U model ≤500W, 4U model ≤800W |
| Mean Time Between Failures (MTBF) | ≥100,000 hours |
6.1.2 Interface Parameters
| Interface | Specification |
|---|---|
| Management Interface | 1 × 10/100/1000BASE-T RJ45 copper port |
| Scanning Interfaces | 4–16 × 10/100/1000BASE-T RJ45 copper ports, 2–8 × 10G SFP+ optical ports |
| Serial Port | 1 × RJ45 Console port, baud rate 9600/115200 |
| USB Interface | 2 × USB 3.0 Type-A ports |
| Expansion Slots | Some models support PCI-E expansion slots for NICs, encryption cards, etc. |
6.2 Software Functional Parameters
6.2.1 Asset Discovery Capability
- Supports multiple target input methods including IP segments, IP ranges, domain names, and asset file import.
- Supports IPv4/IPv6 dual-stack scanning.
- Host discovery accuracy ≥99%.
- Supports operating system fingerprint identification, covering 200+ system versions including Windows, Linux, Unix, and domestic OS.
- Supports device type identification, including servers, switches, routers, firewalls, printers, cameras, and industrial control devices.
- Supports service version identification, covering 3000+ network services and application software.
6.2.2 Vulnerability Detection Capability
- Vulnerability database ≥150,000 entries, continuously updated.
- Covers mainstream vulnerability standards including CVE, CNVD, CNNVD, and NVD.
- System vulnerability detection: Supports full Windows series, mainstream Linux distributions, and Unix system vulnerability detection.
- Web vulnerability detection: Supports all OWASP Top 10 vulnerability types, covering 40+ categories of web vulnerabilities including SQL injection, XSS, CSRF, file upload, command execution, and directory traversal.
- Database vulnerability detection: Supports 15+ mainstream databases including Oracle, SQL Server, MySQL, PostgreSQL, DB2, MongoDB, and Redis.
- Network device vulnerability detection: Supports 50+ mainstream vendor devices including Cisco, H3C, Huawei, Juniper, Sangfor, and QiAnXin.
- Weak password detection: Supports weak password detection for 30+ protocols including SSH, Telnet, FTP, SMB, RDP, MySQL, and Oracle.
- Vulnerability detection accuracy ≥95%, false positive rate ≤3%.
6.2.3 Vulnerability Repair Capability
- Supports automated patch repair for Windows systems, covering Windows 7/10/11 and Windows Server 2008/2012/2016/2019/2022.
- Supports Linux system software package vulnerability repair, supporting mainstream distributions including CentOS, RedHat, Ubuntu, and Debian.
- Patch adaptation accuracy ≥99%.
- Supports batch repair, with single operation supporting up to 1000 hosts repaired simultaneously.
- Supports pre-repair snapshot backup (virtualized environments).
- Supports post-repair automatic verification with verification accuracy ≥98%.
- Repair success rate ≥95% (under normal network and permission conditions).
6.2.4 Baseline Verification Capability
- Built-in Classified Protection 2.0 Level 3 and Level 2 baseline templates.
- Built-in industry special baseline templates for finance, power, medical, and education.
- Supports operating system baseline, database baseline, network device baseline, and middleware baseline verification.
- Supports custom baseline policies, allowing customization of check items based on enterprise internal specifications.
- Number of baseline check items ≥2000.
6.2.5 Performance Parameters
| Parameter | Specification |
|---|---|
| Maximum concurrent scanning IPs per task | 50–2000 (depending on model) |
| Full port scanning speed | ≥1000 ports/second/IP |
| Daily scanning IP count | 500–20,000 (depending on model) |
| Web page crawling speed | ≥500 URLs/minute |
| System response latency | Web management page response time ≤2 seconds |
| Concurrent scan tasks supported | 5–50 (depending on model) |
6.3 Compliance and Qualification Parameters
- Possesses Computer Information System Security Special Product Sales License.
- Passed National Information Security Vulnerability Database (CNNVD) compatibility certification.
- Complies with Cybersecurity Classified Protection 2.0 technical requirements.
- Passed ISO9001 Quality Management System certification.
- Passed ISO27001 Information Security Management System certification.
- Domestic models pass relevant Xinchuang adaptation certifications.
Chapter 7 Product Functions and Features
7.1 Core Functions
7.1.1 Asset Management Functions
- Automatic Asset Discovery: Proactively scans the network, automatically discovers live assets, identifies asset attributes, and builds an asset ledger.
- Asset Classification Management: Supports classification and labeling management of assets by department, business system, zone, importance level, and other dimensions.
- Asset Change Monitoring: Continuously monitors asset changes, automatically alerting when new assets appear, ports change, or services change, promptly identifying shadow assets.
- Asset Lifecycle Management: Records asset security status throughout its full lifecycle from deployment, operations, to decommissioning.
7.1.2 Vulnerability Scanning Functions
- Multiple Scan Modes: Supports quick scan, comprehensive scan, deep scan, custom scan, and other modes to meet different scenario requirements.
- Scheduled Scan Tasks: Supports setting periodic scan tasks by day, week, or month with automatic execution requiring no manual intervention.
- Distributed Scanning: Supports multi-node distributed deployment with unified scheduling, suitable for large-scale cross-subnet networks.
- Scan Intensity Adjustment: Adjustable scan speed and concurrency to prevent excessive scan traffic from affecting business networks.
- Whitelist Mechanism: Supports setting excluded IPs and ports to avoid impact on core business systems.
7.1.3 Risk Assessment Functions
- CVSS Risk Scoring: Uses the international standard CVSS 3.1 scoring system for quantitative vulnerability scoring, divided into three levels: high, medium, and low risk.
- Asset Risk Calculation: Combines asset importance level with vulnerability severity to calculate overall asset risk values, identifying high-risk assets.
- Risk Trend Analysis: Compiles vulnerability count changes and repair rate changes over time, presenting security governance trends.
- Attack Path Analysis: Analyzes correlations between vulnerabilities, simulates potential attacker intrusion paths, and assesses overall network risk.
7.1.4 Vulnerability Repair Functions
- One-Click Repair: Supports one-click batch repair for automatically repairable vulnerabilities, simple and efficient operation.
- Repair Planning: Supports creating repair plans with repair time, scope, and execution order settings, automatically executed per plan.
- Patch Management: Unified patch database management, supporting full lifecycle management of patch download, import, distribution, and deletion.
- Repair Rollback: Supports one-click rollback for patches with compatibility issues, rapidly restoring system state.
- Repair Work Orders: Supports generating repair work orders, assigning to responsible personnel, tracking repair progress, and achieving process-based management.
7.1.5 Compliance Audit Functions
- Multi-Standard Compliance Checking: Built-in multiple compliance baselines including Classified Protection 2.0, ISO27001, PCI-DSS, and industry regulations.
- Compliance Gap Analysis: Automatically compares current configuration against compliance standards, generating non-compliance item lists and remediation recommendations.
- Compliance Reports: One-click generation of compliance audit reports meeting assessment and regulatory inspection requirements.
- Continuous Compliance Monitoring: Periodically executes compliance checks, continuously monitors compliance status, and promptly identifies configuration drift.
7.1.6 Reporting and Visualization Functions
- Rich Report Templates: Provides multiple templates including comprehensive reports, vulnerability special reports, compliance reports, and trend reports.
- Custom Reports: Supports user customization of report content, styles, and logos for different presentation scenarios.
- Multi-Format Export: Supports export in multiple formats including PDF, Word, Excel, and HTML.
- Visualization Large Screen: Provides a security posture display wall, showing the entire network’s asset status, vulnerability distribution, risk levels, and repair progress in real time.
7.1.7 System Management Functions
- User Permission Management: RBAC model-based role permission management, supporting multiple roles and fine-grained permission allocation.
- Operation Log Audit: Complete recording of all user operation logs, supporting log query and audit tracing.
- System Backup and Recovery: Supports backup and recovery of system configuration and data, ensuring data security.
- System Upgrade: Supports both online and offline upgrade methods, with vulnerability database and system versions regularly updated.
- Alarm Notification: Supports multiple alarm methods including email, SMS, Syslog, and Webhook for timely notification of security events.
7.2 Product Features
7.2.1 Comprehensive and Precise Detection Capability
- Wide coverage of vulnerability database, continuously tracking latest vulnerabilities, with high-risk vulnerability signatures updated within 72 hours.
- Combination of multiple detection technologies with AI intelligent algorithms for false positive filtering, achieving industry-leading detection accuracy.
- Supports deep authenticated scanning, comprehensively discovering local security hazards that remote scanning cannot cover.
7.2.2 Integrated Scanning and Repair Closed-Loop
- Industry-leading integrated scanning + repair design, no need to switch between multiple systems, one platform completes the entire process management.
- Automatic correlation between vulnerabilities and patches with automated repair processes, greatly shortening vulnerability exposure time.
- Automatic re-test verification after repair, ensuring effective repair and forming a true security closed-loop.
7.2.3 High Performance and High Stability
- Multi-core parallel scanning engine with optimized task scheduling algorithms, scan efficiency far exceeding similar products.
- Industrial-grade hardware platform with strict reliability testing, supporting 7×24-hour uninterrupted operation.
- Intelligent traffic control that dynamically adjusts scan rates based on network load without affecting normal business operations.
7.2.4 Flexible Deployment and Scalability
- Supports multiple deployment forms including hardware appliance, virtualized, and cloud-native, adapting to different IT environments.
- Distributed architecture design with elastically expandable scanning nodes to meet business growth needs.
- Rich API interfaces, easy to integrate with existing security operations systems.
7.2.5 Domestic (Xinchuang) and Security Trustworthiness
- Full series supports domestic hardware and operating system adaptation, meeting Xinchuang construction requirements.
- System itself undergoes strict security hardening, closing unnecessary ports and services, minimizing attack surface.
- All operations leave audit trails, data transmission is encrypted and stored securely, ensuring device self-security.
7.2.6 Simple and User-Friendly Operation Experience
- Chinese web management interface with clear operation logic, usable without professional training.
- Wizard-based task creation guiding users step-by-step through scan configuration, lowering the usage threshold.
- Intuitive visualization displays with detailed report content, convenient for reporting to management.
Chapter 8 Product Application Scenarios
8.1 Classified Protection Compliance Scenario
According to the requirements of the *Regulations on Cybersecurity Classified Protection*, information systems at Level 2 and above shall regularly conduct vulnerability scanning and security assessment. The Vulnerability Scanning and Repair System fully meets the Classified Protection 2.0 standard requirement to “regularly scan systems for vulnerabilities, promptly discover and repair system vulnerabilities,” helping users:
- Regularly conduct vulnerability scanning and baseline verification, outputting security assessment reports that meet classified protection requirements.
- Provide automated repair solutions for vulnerabilities identified during assessment, helping pass assessments quickly.
- Continuously monitor system security status, maintain long-term compliance, and meet routine regulatory requirements.
Applicable users: Government agencies, public institutions, state-owned enterprises, and other organizations requiring classified protection construction.
8.2 Enterprise Daily Security Operations Scenario
For enterprise security operations teams, vulnerability management is one of the core contents of daily work. This system helps operations personnel improve work efficiency and reduce management difficulty:
- Automated periodic scanning replacing manual detection, freeing up operations manpower.
- Batch vulnerability repair solving the low-efficiency problem of manual patch installation on each machine.
- Automatic asset discovery and change monitoring providing timely awareness of network asset changes, avoiding security risks from shadow assets.
- Unified vulnerability management platform with all vulnerability statuses at a glance, convenient for tracking and review.
Applicable users: Information centers and security operations departments of various small, medium, and large enterprises.
8.3 Regulatory Authority Security Inspection Scenario
Regulatory authorities including cyberspace administration, public security, and industry supervisory departments need to conduct regular security inspections on networks under their jurisdiction. This system provides strong support:
- Supports large-scale network batch scanning, rapidly completing wide-scope security detection.
- Generates standardized inspection reports, convenient for unified assessment and notification.
- Supports multi-level cascading deployment, enabling higher-level authorities to achieve unified supervision and data aggregation of subordinate units.
- Establishes long-term inspection mechanisms, regularly conducting spot checks and re-testing to urge rectification implementation.
Applicable users: Cyberspace administration offices, public security network security departments, and industry regulatory authorities.
8.4 Website Cluster Security Protection Scenario
Government, university, and media organizations typically operate large numbers of portal websites and business systems, making web application vulnerabilities the primary security risk. This system’s web specialized scanning capability effectively addresses this:
- Batch automated scanning of websites, supporting full-site crawling and deep vulnerability detection.
- Regular inspections promptly identifying new vulnerabilities and website defacement risks.
- Provides detailed vulnerability verification information and repair recommendations, guiding developer rectification.
- Supports API interface scanning, covering new web assets such as mobile application backends and microservice interfaces.
Applicable users: Government website clusters, university portal websites, media websites, and internet enterprise application systems.
8.5 Industrial Control System Security Scenario
Industrial control systems are critical information infrastructure whose security directly relates to production safety and social stability. Industrial control system vulnerability scanning has special characteristics, and this system’s industrial control specialized version meets these requirements:
- Supports mainstream industrial control protocol and device identification, including Modbus, S7, and EtherNet/IP.
- Uses low-impact scanning strategies, controlling scan packet transmission rates to avoid impacting industrial control systems.
- Industrial control specialized vulnerability database covering known vulnerabilities of mainstream PLC, SCADA, and DCS systems.
- Meets requirements of the *Industrial Control System Information Security Protection Guidelines*.
Applicable users: Power, petroleum, chemical, rail transit, and manufacturing industrial enterprises.
8.6 Cloud Environment Security Scenario
With the proliferation of cloud computing, vulnerability management for cloud assets such as cloud hosts, cloud databases, and containers has become a new challenge. This system’s cloud-native version adapts to cloud environments:
- Supports automatic cloud asset synchronization, interfacing with cloud platform APIs for real-time cloud asset inventory.
- Elastically scalable scanning capability adapting to the dynamic change characteristics of cloud assets.
- Supports container image vulnerability scanning, identifying image security risks before deployment.
- Meets cloud classified protection and cloud security governance requirements.
Applicable users: Cloud service providers, enterprises using public/private cloud, and cloud-native application teams.
8.7 Security Services and Penetration Testing Scenario
Security service vendors and penetration testing teams can use this system as an auxiliary tool to improve work efficiency:
- Rapid asset detection and vulnerability scanning in the project early stage, comprehensively grasping the target environment situation.
- Automated detection of routine vulnerabilities, allowing security experts to focus on logic vulnerabilities and advanced vulnerability discovery.
- Rapid generation of standardized detection reports, improving project delivery efficiency.
- Assisting clients in completing vulnerability rectification during the repair phase, increasing service value.
Applicable users: Network security service companies, penetration testing teams, and third-party assessment organizations.
Chapter 9 Product Installation
9.1 Pre-Installation Preparation
9.1.1 Environment Inspection
Before installation, confirm that the computer room environment meets the equipment operating requirements:
- Cabinet Space: Confirm that the cabinet has sufficient installation space. A 1U device requires 1U of reserved height, a 2U device requires 2U of reserved height. It is recommended to reserve heat dissipation space above and below the device.
- Power Supply Condition: Confirm that there is an available power outlet in the cabinet, with voltage stable within AC 100-240V. It is recommended to connect to a UPS uninterruptible power supply. Redundant power supply models require two independent power feeds.
- Network Environment: Confirm network connectivity between the management network segment and the scan network segment. Plan the switch ports and VLAN configuration for device connection in advance.
- Temperature and Humidity Environment: The computer room temperature should be maintained between 10°C-35°C, humidity between 20%-80%, with good ventilation, free of dust and corrosive gases.
- Grounding Condition: The cabinet must be properly grounded, with anti-static measures in place.
9.1.2 Tool Preparation
Tools required for installation:
| Tool | Description |
|---|---|
| Phillips screwdriver (PH2) | For installing rack ears and fixing screws |
| Anti-static wrist strap | For ESD protection |
| Multimeter (optional) | For checking power supply |
| Laptop computer | One unit, with network port and serial port |
| Network cables and fiber optic cables | Appropriate lengths, as needed |
9.1.3 Information Planning
Plan the following information before installation:
- Device management IP address, subnet mask, gateway
- Scan interface IP addresses (if using a dedicated scan network segment)
- Administrator account and password
- DNS server address (if online upgrade is required)
- Scan target network segment range
9.2 Hardware Installation Steps
9.2.1 Installing Rack-Mount Ears
1. Wear an anti-static wrist strap and place the device on a stable anti-static workbench.
2. Remove the rack-mount ears and accompanying screws, and align the ears with the screw holes on the sides of the device.
3. Tighten the screws with a screwdriver to secure both side ears. Be careful not to over-tighten the screws to avoid stripping the threads.
9.2.2 Rack-Mounting the Device
1. With two people working together, lift the device smoothly to the mounting height in the cabinet, aligning it with the square holes on the cabinet rails.
2. Align the screw holes of the rack ears with the cabinet rails. Insert the upper two screws first for initial fixing.
3. Adjust the horizontal position of the device, confirm alignment, then tighten all fixing screws.
4. Check that the device is securely mounted, with no looseness or tilting.
9.2.3 Connecting Power Cables
1. Confirm that the device power switch is in the OFF state.
2. Insert one end of the power cable into the device power connector and the other end into the cabinet PDU power outlet.
3. For redundant power supply models, connect two independent power feeds separately.
4. Organize the power cables and secure them with cable ties to avoid cable clutter.
9.2.4 Connecting Network Cables
1. Connect one end of the management network cable to the device’s MGMT management port and the other end to the management switch.
2. According to the plan, connect scan network cables to the corresponding scan interfaces, and the other end to the business switch or core switch.
3. For optical port models, install the optical module first, then connect the fiber optic patch cord. Note that the optical module and fiber type must match: single-mode to single-mode, multi-mode to multi-mode.
4. Check the network port indicator lights. After normal connection, the link light stays steady on and the data light blinks.
9.3 System Initialization Configuration
After hardware installation is complete, perform system initialization configuration. This can be done either via the Console port or the default management IP.
9.3.1 Configuration via Console Port
1. Connect one end of the Console cable to the device’s Console port and the other end to the laptop’s serial port (or USB-to-serial adapter).
2. Open a serial terminal tool such as HyperTerminal or SecureCRT, and set the parameters: baud rate 115200, data bits 8, stop bits 1, no parity, no flow control.
3. Turn on the device power switch, wait for the system to boot, and the serial port will output boot information.
4. After the system boot is complete, enter the default administrator account and password (see the Quick Start Guide for details) to log in to the command line interface.
5. Enter the system configuration view and configure the management IP address:
system-view interface mgmt 0 ip address 192.168.1.100 255.255.255.0 quit ip route-static 0.0.0.0 0.0.0.0 192.168.1.1
6. After configuration is complete, save the configuration and verify network connectivity.
9.3.2 Configuration via Default Management IP
1. Set the laptop’s IP address to the same subnet as the device’s default management IP (default is typically 192.168.0.1/24).
2. Connect the laptop to the device’s management port with a network cable.
3. Open a browser and enter the default management IP address to access the Web management login page.
4. Log in with the default account and password. The password must be changed on first login.
5. Navigate to System Configuration – Network Settings and modify the management IP, subnet mask, gateway, DNS, and other parameters.
6. Click Save. The device applies the new configuration. Re-login using the new IP address.
9.4 License Activation
1. Log in to the Web management platform and navigate to System Management – License Management.
2. View the device hardware serial number and device feature code.
3. Provide the feature code to our sales personnel to obtain the corresponding license file.
4. Import the license file on the License Management page, and the system will automatically activate the corresponding functions.
5. After successful activation, view the license information to confirm that the function modules and validity period are correct.
9.5 System Upgrade
After installation, it is recommended to upgrade the system to the latest version:
1. Navigate to System Management – System Upgrade.
2. Online Upgrade: When the device is connected to the internet, click Check for Updates, download the latest upgrade package, and install it.
3. Offline Upgrade: Download the latest upgrade package from our official website, upload it to the system, and perform the upgrade operation.
4. Do not power off during the upgrade process. The system will automatically restart after the upgrade is complete.
5. After the restart, log in to the system and check the version number to confirm the upgrade was successful.
9.6 Installation Acceptance Criteria
After installation, the following acceptance criteria must be met:
- The device is securely fixed, with no cosmetic damage, and cables are neatly and properly organized.
- The device powers on normally, the power indicator light is steady on, the operation indicator light blinks normally, and no alarm lights are illuminated.
- The management interface network is connected and functioning normally, and the Web management platform can be accessed.
- The scan interface is connected to the target network and functioning normally, and the target network segment gateway can be pinged.
- System license is activated successfully, and all purchased function modules are available.
- System version and vulnerability database are up to date.
- Scan tasks can be created successfully, and a simple scan test can be executed.
Chapter 10 Product Wiring
10.1 Interface Description
The device interfaces are located on the rear panel. The interface definitions are as follows:
| Interface Label | Interface Type | Function Description |
|---|---|---|
| MGMT | RJ45 Copper Port | Management interface for Web management, system upgrade, and remote O&M |
| SCAN1~SCANn | RJ45 Copper Port / SFP+ Optical Port | Scan interface for connecting to the business network to execute scan and remediation tasks |
| HA | RJ45 Copper Port | Dual-machine hot-standby heartbeat interface (high-end models) |
| CONSOLE | RJ45 Serial Port | Command line configuration interface for initialization and troubleshooting |
| USB1/USB2 | USB Type-A | External storage device connection for system backup and offline upgrade |
| POWER | C13 Power Connector | Power input interface |
| POWER SW | Rocker Switch | Device power switch |
10.2 Wiring Specifications
10.2.1 Network Cable Wiring Specifications
- Cable Selection: For gigabit networks, use Category 5e or Category 6 unshielded twisted pair (UTP). For 10-gigabit copper ports, use Category 6 or Category 6a shielded twisted pair.
- Wire Order Standard: Uniformly adopt the T568B standard wire order: Orange-White, Orange, Green-White, Blue, Blue-White, Green, Brown-White, Brown.
- Termination Requirements: The RJ45 connectors at both ends of the network cable must be crimped firmly, with wire conductors neatly arranged, trimmed evenly, inserted to the bottom of the connector, and crimped in place without looseness or broken conductors.
- Testing Requirements: After the network cable is made, test it with a cable tester to ensure all 8 conductors are connected, with no crosstalk or open circuit issues.
- Length Limit: The single-segment network cable length must not exceed 100 meters. For longer distances, use fiber optic or relay equipment.
- Cabling Requirements: Network cables should be routed neatly, avoiding high-voltage lines and interference sources, maintaining a distance of at least 30cm from power cables. The bending radius at turns must not be less than 8 times the cable diameter.
10.2.2 Fiber Optic Cable Wiring Specifications
- Optical Module Selection: Select the corresponding optical module based on transmission distance and wavelength. Multi-mode optical modules use 850nm wavelength with transmission distance up to 300m. Single-mode optical modules use 1310nm/1550nm wavelength with transmission distances of 10km/40km/80km, etc.
- Fiber Patch Cord Selection: Must match the optical module type. Multi-mode fiber is orange, single-mode fiber is yellow. Common connector types are LC and SC, which must match the optical module interface.
- End Face Cleaning: Before inserting the fiber, use a fiber cleaning pen or lint-free tissue to clean the fiber end face, ensuring no dust or contamination that could affect optical power.
- Insertion and Removal: Insert gently into the optical port, aligned properly. A “click” sound indicates it is fully seated. When removing, hold the pull tab and pull out gently. Never pull on the cable itself.
- Bending Radius: The fiber bending radius must not be less than 30mm to avoid fiber breakage or excessive loss due to bending.
- Optical Power Testing: After wiring is complete, use an optical power meter to test the received optical power, ensuring it is within the receive sensitivity range of the optical module.
10.2.3 Power Cable Wiring Specifications
- Use the original power cable supplied with the device. Do not use damaged or aged power cables.
- The power plug and outlet must be in firm contact with no looseness.
- Keep power cables away from cooling vents to avoid high temperatures accelerating cable aging.
- Redundant power supplies must be connected to different power circuits to improve power supply reliability.
- The device must be properly grounded, and the power ground wire must be reliably connected.
10.3 Typical Network Wiring Solutions
10.3.1 Single-Arm Bypass Deployment
This is the most commonly used deployment method. The device’s scan interface connects to a port on the core switch, configured in bypass mode, achieving network-wide scanning through switch mirroring or routable access.
- Wiring Method: The management port connects to the management switch, and the scan port connects to a regular port on the core switch.
- Applicable Scenario: Small and medium-sized networks where real-time scanning is not required and periodic scanning is sufficient.
- Advantages: Simple deployment, does not change the existing network topology, and does not affect network forwarding.
10.3.2 Multi-VLAN Segmented Deployment
For networks with multiple VLANs, multiple scan interfaces can be connected to different VLANs respectively, or a Trunk port can be used to connect to the core switch for cross-VLAN scanning.
- Wiring Method: The scan port is configured in Trunk mode, allowing all VLANs to pass through, and connected to a Trunk port on the core switch.
- Applicable Scenario: Medium-sized multi-VLAN networks.
- Advantages: One interface covers multiple network segments, providing high scanning efficiency.
10.3.3 Dual-Machine Hot-Standby Deployment
High-end models support dual-machine hot-standby. Two devices are connected via an HA heartbeat cable. When the primary device fails, it automatically switches to the standby device, ensuring business continuity.
- Wiring Method: Connect the HA ports of the two devices directly with a network cable. Connect the management ports and scan ports to the corresponding switches respectively.
- Applicable Scenario: Core networks with high availability requirements.
- Advantages: High reliability; a single point of failure does not affect scan operations.
10.3.4 Distributed Deployment
The headquarters deploys a central management platform, and each branch deploys scan probes. The probes communicate with the headquarters via dedicated lines or VPN.
- Wiring Method: The central platform connects to the headquarters core switch, and the probes connect to the branch networks.
- Applicable Scenario: Cross-regional large enterprises and multi-level organizational networks.
- Advantages: Resolves cross-network-segment and cross-region scanning issues, enables unified management, and centralizes data aggregation.
10.4 Wiring Inspection and Verification
After all cabling is complete, perform the following checks:
| Check Item | Description |
|---|---|
| Visual Inspection | Cables are securely connected with no looseness; interface indicator lights are lit normally; cable labels are clear for later maintenance |
| Connectivity Test | Ping the gateway and test hosts of the corresponding network segments from the device to verify network connectivity |
| Bandwidth Test | Perform bandwidth testing when necessary to ensure scan interface bandwidth meets high-traffic scan requirements |
| VLAN Test | In Trunk mode, test connectivity of each VLAN to confirm VLAN configuration is correct |
| Documentation | Create a wiring diagram, record the switch ports, VLANs, and network segment information corresponding to each interface, and archive for future reference |
Chapter 11 Product Commissioning
11.1 Basic System Commissioning
11.1.1 Network Configuration Verification
1. Log in to the Web management platform and navigate to System Configuration – Network Settings.
2. Check that the management port IP address, subnet mask, gateway, and DNS configurations are correct.
3. Use the system’s built-in ping tool and traceroute tool to test connectivity to the gateway, DNS server, and external network addresses.
4. Check the scan interface configuration to confirm that IP addresses, VLAN configurations, and routing configurations are correct.
5. Test connectivity from the scan interface to the target network segments to ensure there is no firewall blocking.
11.1.2 System Status Check
1. Navigate to System Monitoring – Runtime Status to view CPU usage, memory usage, and disk usage, ensuring they are within normal ranges.
- CPU Usage: Should be below 30% under normal idle conditions. It will rise during scans. Long-term usage above 90% is abnormal.
- Memory Usage: Should be below 70% under normal conditions. Above 90% may affect system performance.
- Disk Usage: Data disk usage should be below 80%. Periodically clean up expired data.
2. Check interface status to confirm that all enabled interfaces have normal link status with no packet loss or error packets.
3. Check system service status to confirm that core services such as the scan engine, Web service, database, and remediation engine are running normally.
4. Check the system time and time zone to ensure accuracy. Configure NTP time synchronization if necessary.
11.1.3 License and Version Check
1. Navigate to System Management – License Management to confirm the license status is normal, and verify function modules, IP license quantity, and validity period.
2. Navigate to System Management – System Upgrade to view the current system version and vulnerability database version, confirming they are the latest.
3. Check the vulnerability database update time to ensure it is up to date. Manually trigger an update if necessary.
11.2 Scan Function Commissioning
11.2.1 Creating a Test Scan Task
1. Navigate to Vulnerability Scan – Task Management and click New Task.
2. Enter “Test Scan Task” as the task name and select “Quick Scan” as the task type.
3. Target Settings: Enter a small number of test IP addresses, such as 1-2 test servers, to avoid affecting business operations.
4. Scan Policy: Select the default quick scan policy. Select common ports for port scanning and set the concurrency to a lower value.
5. Scan Time: Select Execute Immediately.
6. Click Confirm to start the scan task.
11.2.2 Monitoring the Scan Process
1. View the task status in the task list, from “Queued” to “Running” to “Completed”.
2. Click task details to view real-time scan progress, the number of scanned IPs, and the number of discovered vulnerabilities.
3. Observe system resource usage to confirm CPU, memory, and network bandwidth are within acceptable ranges.
4. Observe target host status to confirm the scan has not caused abnormal impact on target systems.
11.2.3 Verifying Scan Results
1. After the scan is complete, view the scan report.
2. Check Asset Identification Results: Confirm that target hosts are correctly identified, including accurate identification of operating systems, open ports, and service versions.
3. Check Vulnerability Results: Confirm that discovered vulnerabilities match the actual situation of the target systems, with no obvious false positives. Select 1-2 known vulnerabilities for manual verification.
4. Check Report Content: Confirm the report structure is complete, and vulnerability descriptions, risk levels, and remediation recommendations are clear and accurate.
11.2.4 Testing Different Scan Types
Test the following scan types sequentially to confirm each function module is working properly:
| Scan Type | Test Method |
|---|---|
| Full Port Scan | Test the completeness and speed of port scanning |
| Web Application Scan | Enter a test website address to test web vulnerability detection |
| Weak Password Scan | Configure test accounts to test weak password detection |
| Baseline Check | Select one host for authenticated scanning to test baseline checking |
| Database Scan | Configure database connection information to test database vulnerability detection |
11.3 Remediation Function Commissioning
11.3.1 Remediation Environment Preparation
1. Prepare a test server with known patchable vulnerabilities, ensuring the system version is compatible with the patch library.
2. Confirm network connectivity between the scanning device and the test server, and that relevant ports (Windows ports 135, 445, 139; Linux port 22) are not blocked by firewalls.
3. Prepare the administrator account and password for the test server, with system patch installation privileges.
11.3.2 Patch Library Check
1. Navigate to Vulnerability Remediation – Patch Management to view the patch library status.
2. Online Mode: Test the patch download function to confirm it can connect to the patch server normally and download at normal speed.
3. Offline Mode: Import a test patch package to confirm patches can be correctly identified and categorized.
11.3.3 Executing Remediation Tests
1. Perform a vulnerability scan on the test server to confirm patchable vulnerabilities exist.
2. On the vulnerability details page, check the target vulnerabilities and click “One-Click Remediation”.
3. Enter the administrator account and password for the target host and confirm the remediation method.
4. Start the remediation task and monitor the remediation progress in the task monitor.
5. Observe the target server status to confirm patches are installed normally and the system has no abnormalities.
11.3.4 Remediation Verification
1. After remediation is complete, the system automatically performs a re-scan.
2. View the re-scan results to confirm the corresponding vulnerability status has changed to “Remediated”.
3. Log in to the target server and manually check the patch installation records to confirm the patch was successfully installed.
4. Confirm the test server’s business operations are running normally with no compatibility issues.
11.4 Alarm and Report Commissioning
11.4.1 Alarm Configuration Testing
1. Navigate to System Management – Alarm Settings.
2. Configure Email Alarms: Enter SMTP server information and recipient addresses, send a test email, and confirm it is received normally.
3. Configure Syslog Alarms: Enter the log server address, trigger a test alarm, and confirm the log server receives it normally.
4. Configure high-risk vulnerability alarm rules and test whether alarm notifications are triggered when high-risk vulnerabilities are discovered.
11.4.2 Report Function Testing
1. Navigate to the Report Center and select different report template types.
2. Generate test reports and verify report content is complete and data is accurate.
3. Test the export function by exporting in PDF, Word, and Excel formats, confirming successful export with correct formatting.
4. Test the custom report function by modifying report content and logos, confirming reports can be generated normally.
11.5 Performance Tuning
Tune system performance according to the actual network environment and business requirements:
| Tuning Item | Description |
|---|---|
| Scan Concurrency Adjustment | Adjust scan concurrency threads based on network bandwidth and target system tolerance, finding a balance between scan speed and business impact |
| Scan Timeout Settings | For environments with high network latency, appropriately increase timeout values to reduce missed detections |
| Scheduled Task Optimization | Schedule large-scale scan tasks during nighttime off-peak hours to avoid occupying business bandwidth |
| Data Cleanup Policy | Configure automatic cleanup policies to periodically delete expired scan reports and logs, freeing disk space |
| Scan Whitelist | Add core business systems and older fragile systems to the whitelist or reduce scan intensity to avoid affecting business operations |
11.6 Commissioning Completion Criteria
After commissioning, the system must meet the following criteria:
- The system runs stably, all services are normal, and there are no abnormal alarms.
- Network connectivity is normal, and all planned network segments can be scanned normally.
- All scan function tests pass, detection results are accurate, with no obvious false positives or false negatives.
- Automated remediation functions work normally, patch installation success rates meet targets, and remediation verification is effective.
- Alarm notification and report functions are available and working.
- System performance meets business requirements, and the scan process does not affect normal business operations.
- Complete commissioning records and configuration documentation are output and handed over to operations personnel.
Chapter 12 Product Precautions
12.1 Installation Environment Precautions
- The device must be installed in a standard 19-inch cabinet. Do not place it on the floor or on unstable surfaces to prevent the device from falling and being damaged.
- Sufficient heat dissipation space must be reserved around the device. Front and rear ventilation openings must not be blocked to avoid device overheating and failure.
- The computer room must be kept clean to prevent dust from entering the device, which can affect heat dissipation and circuit insulation. Clean surface dust from the device periodically.
- Avoid installing the device in environments with moisture, corrosive gases, or strong electromagnetic interference.
- The device must be reliably grounded to prevent static damage to hardware and ensure personnel safety.
- Power supply voltage must be stable. It is recommended to connect to a UPS power supply to prevent sudden power outages from causing system damage and data loss.
12.2 Network Security Precautions
- It is recommended to assign a dedicated management VLAN to the device management port. Do not expose it directly to the public network. Restrict management IP access ranges.
- The default administrator password must be changed on first login. Passwords must meet complexity requirements and be changed periodically.
- Strictly manage user account permissions, follow the principle of least privilege, and prohibit multiple users from sharing the same account.
- Scan tasks must be officially authorized. Scanning unauthorized external networks is prohibited to avoid violating laws and regulations.
- When scan targets include production business systems, assess the impact in advance, schedule scans during off-peak business hours, and notify relevant departments in advance when necessary.
- The device itself requires regular security hardening and vulnerability checks. Upgrade system patches in a timely manner to prevent the device from being compromised and used as an attack springboard.
- Scan data and reports are sensitive information and must be properly secured. Unauthorized dissemination is prohibited to prevent exploitation by attackers.
12.3 Scan Operation Precautions
- When first scanning an unfamiliar network, it is recommended to first use low-intensity quick scan. Only proceed with deep scanning after confirming no abnormalities.
- When scanning industrial control systems, older systems, and core business systems, the scan rate and concurrency must be reduced. Use authenticated scan mode when necessary to avoid business interruption.
- Unauthorized Web vulnerability scanning of internet websites is prohibited, as it may violate the Cybersecurity Law.
- Weak password scanning must be used with caution to avoid account lockouts. Multiple failed attempts may trigger the target system’s account lockout policy, affecting legitimate user logins.
- Before large-scale scanning, it is recommended to notify the network administrator in advance to avoid being mistaken for a network attack and triggering security alarms.
- The number of scan tasks must be kept within the device’s performance capacity. Avoid running too many tasks simultaneously, which could cause system crashes or inaccurate scan results.
12.4 Vulnerability Remediation Precautions
- Back up target system data before vulnerability remediation. For critical systems, take snapshots or full system backups first to prevent system failures caused by patch installation failures.
- Before patch installation, verify compatibility in a test environment first. After confirming no issues, deploy in batches to the production environment. It is recommended to adopt a gray-release strategy: start with a small pilot scope, then fully roll out.
- Schedule remediation operations during off-peak business hours to avoid impacting business when system restarts are required during patch installation.
- For vulnerabilities that cannot be automatically remediated, manually assess the risk and adopt other protective measures such as deploying WAF, firewall policies, or virtual patches.
- Business verification must be performed after patch installation to confirm application systems, databases, and services are running normally.
- Some patches have dependency relationships and must be installed in the correct order. The system automatically handles dependencies; do not manually disrupt the order.
- For third-party software vulnerability remediation, confirm software licensing to avoid incompatibility between patches and software versions.
12.5 System Maintenance Precautions
- Regularly update the vulnerability database and system version to obtain the latest vulnerability detection capabilities and feature optimizations. Emergency updates are required when high-risk vulnerabilities break out.
- Regularly back up system configuration and important data. It is recommended to back up at least once per week, and store backup files offsite.
- Regularly clean up expired scan tasks, reports, and log data to free disk space and prevent system anomalies caused by full disks.
- Installing unauthorized software on the device is prohibited. Modifying system configurations and underlying parameters without authorization is prohibited.
- Back up configurations before system upgrades. Do not power off during the upgrade process. Verify functions are normal after the upgrade.
- When restarting a device that has been out of service for an extended period, check hardware status first, then power on gradually to avoid damage from instantaneous current surges.
12.6 Personnel Operation Precautions
- Only trained professional operations and maintenance personnel may operate this device. Unauthorized personnel are prohibited from operating it.
- Confirm the impact scope of operations before proceeding. High-risk operations (such as system upgrades, configuration deletion, and batch remediation) require approval and two-person operation.
- Performing operations unrelated to work in the system and using the system for illegal activities are prohibited.
- If any abnormality occurs during operation, stop immediately, record the abnormal phenomenon, and contact technical support personnel for handling. Disassembling the device for repair without authorization is prohibited.
- Strictly comply with company security management policies and confidentiality regulations. Safeguard account passwords and sensitive data.
Chapter 13 Product Repair and Maintenance
13.1 Routine Maintenance
13.1.1 Daily Inspection
Perform routine inspection of the device daily and record operating status:
1. Check device indicator lights – whether the power light and operation light are normal, and whether any alarm lights are illuminated.
2. Check whether the device fans are operating normally and whether there is any abnormal noise.
3. Log in to the Web management platform and check whether CPU, memory, and disk usage are normal.
4. Check for abnormal alarm messages and handle alarm events in a timely manner.
5. Check the computer room temperature and humidity, and record environmental parameters.
13.1.2 Weekly Maintenance
Perform a comprehensive maintenance check weekly:
| Check Item | Description |
|---|---|
| Cleaning | Clean surface dust from the device with a dry soft cloth; do not use liquid cleaners |
| Cable Inspection | Check cable connections for tightness and organize tangled cables |
| System Log Review | Check system logs and analyze for abnormal logins or abnormal operations |
| Disk Space Check | Check disk space and clean up unnecessary temporary files and expired data |
| Backup Verification | Verify backup tasks executed normally and backup files are complete |
13.1.3 Monthly Maintenance
Perform in-depth maintenance monthly:
1. Clean dust from the device air intake dust filter to maintain smooth ventilation.
2. Check power connectors and network port connectors for looseness or oxidation.
3. Perform a comprehensive system health check and generate a system health report.
4. Verify the vulnerability database version and confirm it has been updated to the latest.
5. Review the vulnerability scanning and remediation status of the past month and optimize the next month’s scan plan.
13.1.4 Annual Maintenance
Perform a comprehensive maintenance annually:
1. Power off the device for dust removal. Use a blower (cold air setting) to clean internal dust, taking anti-static precautions.
2. Check fan operation. Lubricate or replace fans if bearings lack lubrication.
3. Check the power module working status and test the redundant power switching function.
4. Check hard disk health status, investigate bad sector risks, and replace if necessary.
5. Perform comprehensive functional testing and performance testing to evaluate device condition.
6. Calibrate system time, check license validity period, and arrange for renewal in advance.
13.2 Fault Classification and Handling Procedure
13.2.1 Fault Classification
Faults are classified into three levels based on impact severity:
| Level | Description |
|---|---|
| Level 1 (Critical) | Device is completely down, cannot start, or core functions have failed, severely impacting business operations |
| Level 2 (Major) | Partial functions are abnormal, performance has significantly degraded, or frequent alarms occur, affecting some business operations |
| Level 3 (Minor) | Minor function anomalies, occasional alarms, or small issues that do not affect core business operations |
13.2.2 Fault Handling Procedure
1. Fault Detection: Operations personnel discover faults through routine inspection or system alarms. Record the fault phenomenon, time of occurrence, and impact scope.
2. Initial Troubleshooting: Perform initial checks according to the fault troubleshooting manual. Attempt simple recovery operations such as restarting services or restarting the device.
3. Fault Escalation: For faults that cannot be resolved independently, escalate to the supervisor in a timely manner and contact our technical support.
4. Technical Support: Our technical engineers diagnose and repair the fault remotely or on-site.
5. Fault Recovery: After the fault is resolved, verify system functions have returned to normal and record the fault cause and resolution.
6. Post-Mortem Review: Conduct a review after major faults, analyze the root cause, and formulate preventive measures to avoid recurrence.
13.3 Common Hardware Fault Repair
13.3.1 Power Supply Fault
- Fault Symptoms: The device shows no response after power-on, the power light does not illuminate, and fans do not spin.
- Troubleshooting Steps:
1. Check whether the power cable is firmly inserted and whether the power outlet has power.
2. Replace the power cable for testing to rule out a damaged power cable.
3. For redundant power supply models, perform crossover testing to determine if a single power module has failed.
- Resolution: After confirming the power module is faulty, contact our company to replace the power module. Replacement is free of charge during the warranty period.
13.3.2 Hard Disk Fault
- Fault Symptoms: Slow system startup, frequent error messages, data loss, and disk alarms.
- Troubleshooting Steps:
1. Log in to the system to check disk health status and SMART information.
2. Check whether disk read/write speed is abnormal.
- Resolution:
1. Back up important data.
2. In RAID mode, the faulty hard disk can be replaced directly and the system will automatically rebuild.
3. In non-RAID mode, the system must be reinstalled after replacing the hard disk, then restore the configuration backup.
13.3.3 Network Interface Port Fault
- Fault Symptoms: The corresponding network port light does not illuminate, network connectivity fails, and ping fails.
- Troubleshooting Steps:
1. Check whether the network cable is normal; replace the cable for testing.
2. Change switch ports for testing to rule out switch port failure.
3. Plug the network cable into other known-good interfaces for testing to determine if the interface is damaged.
- Resolution: If the hardware interface is confirmed damaged, use another available interface or contact our company for repair or replacement.
13.3.4 Fan Fault
- Fault Symptoms: Abnormal fan noise, fan not spinning, or device over-temperature alarm.
- Troubleshooting Steps:
1. Observe whether the fan is spinning and whether any foreign objects are stuck.
2. Listen for abnormal friction sounds from the fan.
- Resolution:
1. Clean fan dust and remove foreign objects.
2. If the fan is damaged, contact our company to replace the fan module.
3. If temperature is too high, shut down first to cool down and avoid burning out hardware.
13.4 Software Fault Repair
13.4.1 System Login Failure
- Fault Symptoms: The Web management page cannot be opened, showing connection timeout or errors.
- Troubleshooting Steps:
1. Test network connectivity to confirm the device management IP can be pinged.
2. Check browser settings, clear the cache, and test with a different browser.
3. Log in via the Console port to the command line and check the Web service status.
- Resolution:
1. Restart the Web service process.
2. If configuration errors caused the issue, restore the default network configuration.
3. Restart the device if necessary.
13.4.2 Scan Task Abnormal Termination
- Fault Symptoms: A scan task stops suddenly during operation, and the status shows Failed.
- Troubleshooting Steps:
1. View the task log to identify the reason for failure.
2. Check system resources – whether insufficient memory caused a process crash.
3. Check whether the network is interrupted or the target is unreachable.
- Resolution:
1. If resources are insufficient, reduce the number of concurrent tasks and lower concurrency settings.
2. For network issues, troubleshoot the network link.
3. For system bugs, upgrade to the latest version.
13.4.3 System Lag and Slow Response
- Fault Symptoms: Slow Web operation response, slow scan speed, and high system load.
- Troubleshooting Steps:
1. Check CPU, memory, and disk usage to identify the bottleneck.
2. Check whether too many scan tasks are running simultaneously.
3. Check whether abnormal processes are consuming resources.
- Resolution:
1. Pause non-essential tasks to release system resources.
2. Clean up disk space and delete expired data.
3. Optimize scan policies to reduce concurrency.
4. If performance is insufficient, consider upgrading to a higher-performance model.
13.4.4 System Crash and Startup Failure
- Fault Symptoms: The system cannot start normally after power-on, staying on the boot screen or looping through restarts.
- Troubleshooting Steps:
1. View boot logs via the Console port to identify the point of startup failure.
2. Check whether hard disk failure has caused system file damage.
- Resolution:
1. Attempt to enter single-user mode to repair the system.
2. If unable to repair, reinstall the system and restore the configuration backup.
3. Contact our technical support for assistance.
13.5 Maintenance Precautions
- During the warranty period, disassembling the device without authorization is prohibited; otherwise, the warranty will be voided.
- Hardware replacement must use our company’s original parts. Using third-party compatible parts is prohibited to avoid causing greater damage.
- All maintenance operations must be performed with the power off, wearing an anti-static wrist strap to prevent static damage to chips.
- Before system reinstallation, be sure to back up all important data. Reinstallation will erase all data on the system disk.
- Keep detailed records during fault handling, including fault symptoms, operation steps, and results, to facilitate future review.
13.6 Warranty Service Description
| Item | Description |
|---|---|
| Standard Warranty | 3-year hardware warranty and 1-year software upgrade and technical support service |
| Extended Warranty | Extended service periods can be purchased separately |
| Covered Services | Hardware faults not caused by human damage are repaired or replaced free of charge within the warranty period |
| Not Covered | Human damage, water damage, drops, unauthorized disassembly/modification; damage from force majeure (fire, flood, lightning, etc.); damage caused by use of non-original parts; devices beyond warranty period |
| Service Response | 7×24-hour technical support hotline; 4-hour response for Level 1 faults; on-site service availability depends on distance |
Chapter 14 Common Problems and Solutions
14.1 Device Login Issues
Problem 1: The administrator password has been forgotten.
Solutions:
1. Connect to the device via the Console port and enter single-user mode.
2. Execute the password reset command to reset the admin account password.
3. Restart the device and log in with the new password.
4. If you are not familiar with the operation, contact our technical support for guidance.
Problem 2: The Web management page cannot be opened, showing “Cannot access”.
Solutions:
1. Check whether the computer and device are on the same network; ping the management IP to see if it responds.
2. Check whether the browser is using a proxy; try disabling the proxy.
3. Check whether the device management port is disabled; view the interface status via the Console port.
4. Check whether the device IP conflicts with other devices on the network.
5. Try accessing via HTTPS, or switch browsers and clear the browser cache.
Problem 3: Logged out automatically shortly after login.
Solutions:
1. Check the system session timeout setting; the timeout period can be extended appropriately.
2. Check whether other users are logged in with the same account, as session conflict can cause logout.
3. Check browser Cookie settings and allow the site to save cookies.
4. Unstable network can cause session interruption; check network connection stability.
14.2 Scan Function Issues
Problem 1: Scan tasks remain in “Queued” status for a long time and do not start.
- Cause Analysis: The number of simultaneously running tasks has reached the system limit, and new tasks must wait in the queue.
- Solutions:
1. Wait for running tasks to complete; new tasks will start automatically.
2. Pause or cancel some non-urgent tasks to release resources.
3. If the number of tasks frequently exceeds the limit, consider upgrading to a higher-performance model.
Problem 2: The number of live hosts in scan results is low, and many IPs cannot be scanned.
- Cause Analysis: Network connectivity issues, firewall blocking, or overly strict scan policies.
- Solutions:
1. Ping the target IP from the device to confirm network connectivity.
2. Check whether intermediate firewalls or security devices are blocking scan packets; allow access from the scanning device’s IP.
3. Adjust the scan policy – increase host discovery methods and extend timeout values.
4. Confirm the target IP network segment is correct and that hosts are actually alive and not blocking ping.
Problem 3: Scan speed is extremely slow, taking a long time to complete.
- Cause Analysis: Concurrency set too low, high network latency, excessive port filtering on targets, or full port scanning.
- Solutions:
1. Appropriately increase scan concurrency threads to improve scan speed.
2. For poor network quality, appropriately reduce timeout values to avoid long waits on unresponsive ports.
3. Avoid full port scans when not necessary; using common port scans can significantly improve speed.
4. Check system CPU and memory usage; if resources are insufficient, reduce the number of simultaneously running tasks.
Problem 4: Many false positive vulnerabilities are reported.
- Cause Analysis: Inaccurate version matching, protective devices on target systems, or detection signature deviations.
- Solutions:
1. Enable deep scan and PoC verification mode to improve detection accuracy.
2. Manually verify false positive vulnerabilities and mark them as false positives in the system; the system will learn and optimize.
3. Update to the latest vulnerability database version; false positive issues are continuously optimized.
4. If the target has WAF or firewalls that may affect scan results, configure a whitelist before scanning.
Problem 5: Web vulnerabilities cannot be scanned even though the website clearly has issues.
- Cause Analysis: Crawler restrictions, login state issues, website anti-crawling mechanisms, or insufficient scan depth.
- Solutions:
1. Check whether the website can be accessed normally and whether there are CAPTCHA or login restrictions.
2. Configure login authentication information for authenticated scanning.
3. Increase Web scan depth and page crawl count limits.
4. For websites with anti-crawling mechanisms, appropriately reduce crawl speed and configure a custom User-Agent.
5. For API interfaces, use API scan mode and import API documentation.
14.3 Vulnerability Remediation Issues
Problem 1: One-Click Remediation does not respond, and the remediation task fails.
- Cause Analysis: Network connectivity issues, insufficient permissions, blocked ports, or no corresponding patch available.
- Solutions:
1. Check network connectivity between the scanning device and the target host to ensure normal communication.
2. Check whether the target host’s firewall allows the corresponding ports (Windows 135/445, Linux 22).
3. Confirm the entered administrator account and password are correct and have patch installation privileges.
4. Check whether the vulnerability supports automatic remediation; some vulnerabilities do not yet have automated remediation solutions and require manual remediation.
5. Check whether the corresponding patch exists in the patch library; offline environments require importing patch packages first.
Problem 2: Patch installation fails, indicating incompatibility.
- Cause Analysis: System version mismatch, missing prerequisite patches, or incorrect system language.
- Solutions:
1. Confirm the target system version, architecture, and language are compatible with the patch.
2. Check whether prerequisite dependency patches are missing; install prerequisite patches first.
3. Some customized system versions may be incompatible with official patches; manually download the corresponding vendor patches and install.
4. View the patch installation log to identify the specific reason for failure.
Problem 3: The vulnerability still exists after remediation, and re-scan still shows it as present.
- Cause Analysis: The patch was not actually installed successfully, a restart is required for the patch to take effect, or the re-scan was not performed correctly after remediation.
- Solutions:
1. Log in to the target system and check the patch installation records to confirm whether the patch was actually installed successfully.
2. Some patches require a system restart to take effect; restart as prompted and then re-scan.
3. Manually trigger a full scan to confirm whether the vulnerability truly still exists.
4. If the vulnerability has been truly remediated but is still reported, it may be a false positive; mark it as resolved.
Problem 4: System malfunctions after remediation, and business stops working.
- Cause Analysis: Patch compatibility issues or conflict between the patch and business software.
- Solutions:
1. Immediately uninstall the corresponding patch to restore the system state.
2. For patches that support rollback, perform the rollback operation.
3. Investigate compatibility between business software and the patch; find vendor solutions.
4. Always back up critical systems before remediation and verify in the test environment first.
14.4 System Performance Issues
Issue 1: CPU usage remains consistently high
Cause Analysis: Large numbers of scanning tasks are being executed, abnormal system processes, virus or attack.
Solution:
- Check the currently running scan tasks. High CPU usage when there are many tasks is a normal phenomenon.
- If CPU usage is high despite no active tasks, check for abnormal processes and try restarting the system.
- Check for unauthorized logins and attack behavior, and strengthen the device’s own security protection.
- If CPU usage remains consistently high over a long period, consider upgrading the hardware configuration.
Issue 2: What to do when disk space is full
Cause Analysis: Scan reports, logs, and patch files have accumulated excessively without timely cleanup.
Solution:
- Go to the data management page and delete expired scan tasks, reports, and log files.
- Clean up outdated patch files in the patch library that are no longer needed.
- Configure automatic cleanup policies, set data retention periods, and the system will automatically clean up expired data.
- If the data volume is indeed very large, consider expanding the disk or upgrading to a higher-capacity model.
Issue 3: Device frequently crashes and restarts
Cause Analysis: Hardware failure, poor heat dissipation, unstable power supply, system bugs.
Solution:
- Check if the device temperature is too high, clean dust, and improve ventilation.
- Check whether the power supply is stable and connect to a UPS power source.
- Upgrade the system to the latest stable version to eliminate software bugs.
- If this occurs frequently, it is likely a hardware failure — contact our company for inspection and repair.
14.5 Upgrade and Licensing Issues
Issue 1: Online upgrade fails, prompt says “Failed to connect to server”
Cause Analysis: Device cannot access the internet, incorrect DNS configuration, firewall blocking the upgrade server.
Solution:
- Test whether the device can ping public network addresses and check network connectivity.
- Check whether the DNS configuration is correct and whether domain names can be resolved properly.
- Check whether the outbound firewall is blocking the upgrade server address and allow the corresponding permissions.
- If online upgrade is not possible, use the offline upgrade method by downloading the upgrade package and manually importing it.
Issue 2: What to do when the license expires
Solution:
- Contact our company’s business personnel to process license renewal.
- After obtaining the new license file, import it into the system to activate.
- After the license expires, the vulnerability database stops updating, but existing scanning functions remain operational — only detection of new vulnerabilities is unavailable.
Issue 3: Importing license file prompts “Invalid”
Cause Analysis: The license file does not match the device, the file is corrupted, or the version is incompatible.
Solution:
- Confirm that the license file corresponds to the current device’s serial number. Each device has a unique license that cannot be interchanged.
- Re-download the license file to ensure the file is complete and not corrupted.
- Confirm that the system version is compatible with the license version. Older systems may not support new licenses — upgrade the system first.
Chapter 15: Product QA
Q1: Will vulnerability scanning crash the business system?
A: Under normal circumstances, no. Our system employs non-destructive detection technology. The scanning process only sends detection data packets and does not perform destructive operations on target systems. The system’s default scanning intensity is optimized and has minimal impact on business systems. However, for extremely old systems with poor performance, or when concurrency settings are too high, there may be some network or system resource consumption. It is recommended that when scanning core business systems for the first time, lower the scan concurrency and choose off-peak business hours.
Q2: How often should vulnerability scanning be performed?
A: Based on Classified Protection (Classified Protection) requirements and industry best practices, it is recommended:
- External internet assets: Scan at least once per week, with emergency scanning when high-risk vulnerabilities break out.
- Internal core business systems: Scan once every two weeks.
- General office terminals: Scan once per month.
- Before major holidays and important events, a comprehensive scan and hardening should be performed.
- After system launches and major changes, conduct security scans promptly.
- Specific frequencies can be adjusted according to enterprise security level requirements and actual conditions.
Q3: Do all vulnerabilities need to be fixed?
A: No — this is neither necessary nor realistic. It is recommended to handle vulnerabilities in a graded manner based on risk level and business impact:
- High-risk vulnerabilities: Must be fixed immediately, with remediation completed within 72 hours.
- Medium-risk vulnerabilities: Develop a remediation plan and complete fixes within one month.
- Low-risk vulnerabilities: Can be handled together with system upgrades, or mitigated with compensating controls.
- For vulnerabilities that cannot be fixed (e.g., old systems without patches), protection can be achieved through deploying firewalls, WAFs, access control, etc., to reduce risk.
Q4: Will automatic remediation damage the system?
A: The patches pushed by the system are all officially released formal security patches that have undergone compatibility testing and will not damage the system under normal circumstances. However, due to the complexity of enterprise environments with various custom software and special configurations, compatibility issues may rarely occur. It is recommended:
- Back up important systems or take snapshots before remediation.
- Verify in a test environment first, then deploy to production.
- Use phased remediation — first pilot on a small scale, then roll out in batches.
- The system supports patch rollback functionality for quick recovery if problems occur.
Q5: How many IPs can the system scan? What if it’s not enough?
A: Different models support different numbers of concurrent scanning IPs, ranging from 50 to several thousand, depending on the product model. The concurrency number refers to the number of IPs scanned simultaneously; the number of IPs scanned per day is far greater than the concurrency number. If the number of IPs exceeds the capability of a single device, you can:
- Upgrade to a higher-tier model to increase concurrency capability.
- Adopt distributed deployment with additional scanning probe nodes, managed centrally by the center platform.
- Scan in batches by grouping assets, scanning different groups at different times.
Q6: How often is the vulnerability database updated? Can high-risk vulnerabilities be covered in time?
A: The regular vulnerability database is updated weekly, synchronizing the latest CVE and CNVD vulnerabilities. For major high-risk vulnerabilities (such as Log4j, SpringShell, etc.), our security team completes vulnerability verification and signature development within 72 hours and pushes emergency updates. Users can enable automatic updates, and the system will automatically download the latest vulnerability database.
Q7: Can the device be placed on the public internet to directly scan internet assets?
A: Technically yes, but it is not recommended to expose the device’s management interface directly to the public internet. The scanning interface can be connected to the public internet, but note:
- Scanning internet websites requires authorization from the target owner. Unauthorized scanning may violate the Cybersecurity Law of the People’s Republic of China.
- The device itself should be security-hardened: change default ports and restrict management IP access.
- It is recommended to deploy in a DMZ zone with access control through a firewall.
Q8: Does it support domestic (Chinese) operating systems? Can it pass Classified Protection (Classified Protection)?
A: Yes. We have a dedicated domestic series that adapts to domestic CPUs such as Hygon and Phytium, and is compatible with domestic operating systems such as Kylin and UOS, meeting Xinchuang (IT application innovation) project requirements. The product holds a national security-specific product sales license and fully meets the technical requirements for vulnerability scanning under Classified Protection 2.0. Many customers have successfully passed Level 2 and Level 3 Classified Protection assessments using our products.
Q9: Where is scan data stored? Will it be leaked?
A: All scan data is stored on the device’s local hard drive and is not automatically uploaded to the cloud (the cloud intelligence edition only uploads anonymous vulnerability statistics data, not user-sensitive information). The device itself is security-hardened, and data access is permission-controlled. Users can manage their own data, with periodic backups and cleanup. We are committed to strictly protecting user data privacy and will not disclose any user scan data.
Q10: What happens to the data if the device fails?
A: It is recommended to regularly back up system configuration and data, which can be exported to local storage. After hardware failure, replacing with a new device and importing the backup data allows for recovery. High-end models support RAID disk arrays, so a single hard disk failure will not result in data loss. For particularly important data, it is recommended to regularly export and archive.
Q11: Will weak password scanning lock out accounts?
A: This is possible. The system’s default brute-force attempts are limited and the speed is relatively slow to reduce the risk of lockout. However, if the target system has strict account lockout policies (e.g., lockout after 3 failed attempts), this could still be triggered. It is recommended:
- Communicate with administrators before weak password scanning to understand account lockout policies.
- Use custom dictionaries that only test common weak passwords to reduce the number of attempts.
- Scan important system accounts with caution, or use whitelist methods to exclude them.
- After scanning, check whether any accounts have been locked and unlock them promptly.
Q12: Can it integrate with our existing SOC or operations platform?
A: Yes. The system provides standard RESTful API interfaces, Syslog interfaces, and SNMP interfaces, and can integrate with mainstream SOC platforms, operations management platforms, 4A systems, and ticketing systems. It supports synchronizing vulnerability data and alarm information to third-party platforms for unified management. For specific integration, contact technical support to obtain interface documentation.
Q13: Can it be used in physically isolated intranets? How are patches updated?
A: Absolutely. The device supports pure offline deployment; vulnerability databases and system upgrades can be updated through offline upgrade packages. We regularly publish offline upgrade packages that users can download and import via USB drive. The patch library also supports offline import, suitable for classified intranets and physically isolated environments.
Q14: Does the device require dedicated staff for maintenance? Is it difficult to operate?
A: No dedicated personnel are required. Ordinary operations staff can operate it after simple training. The system uses a Chinese web interface with a simple and intuitive design, wizard-style operation, and is easy to learn. Daily work mainly involves reviewing reports, handling alarms, and periodically updating the vulnerability database — the workload is light. We also provide complete operation training and technical support services.
Q15: How long is the warranty? How quickly can a faulty device be repaired?
A: The standard hardware warranty is three years, with software upgrades and technical support services for one year. Extended warranties are available. Fault response time: 7×24-hour hotline support; issues that can be resolved remotely are resolved immediately. For hardware failures requiring replacement, 4-hour on-site service within the urban area; for remote areas, it depends on distance. Non-human-caused damage during the warranty period is repaired or replaced free of charge.
Chapter 16: Product Acceptance
16.1 Acceptance Basis
This acceptance is based on the following documents and standards:
- Procurement contract and technical agreement
- Product manual and technical specification sheet
- “Information Security Technology — Technical Requirements for Vulnerability Scanning Products” (GB/T 20278-2022)
- “Cybersecurity Law — Baseline for Classified Protection of Cybersecurity” (GB/T 22239-2019)
- Acceptance plan confirmed by both parties
16.2 Acceptance Conditions
Acceptance must meet the following prerequisites:
- Equipment installation, wiring, and commissioning have been completed, and the system is operating normally.
- System license has been activated, and all purchased functional modules are normally available.
- System version and vulnerability database have been upgraded to the latest versions.
- The implementation party has completed operational training, and the user’s operations staff have mastered basic operations.
- Acceptance documentation is complete, including installation reports, commissioning records, user manuals, etc.
- The system has been in trial operation for at least 7 days, running stably without major failures.
16.3 Acceptance Content and Standards
16.3.1 Hardware Acceptance
- Appearance check: Device appearance is intact, no scratches, deformation, or damage; accessories are complete and consistent with the packing list.
- Installation standards: Device is securely installed, cabling is neat and standardized, labels are clear, complying with data center cabling standards.
- Hardware configuration: Verify that CPU model, memory size, disk capacity, and interface count match the contract configuration.
- Operating status: Device powers on normally, indicator lights are in normal state, no alarms, fans operate normally, no abnormal noise.
- Interface testing: All network ports, serial ports, and USB interfaces function normally.
16.3.2 Functional Acceptance
- Asset management function: Can automatically discover live hosts in the specified network segment, correctly identify operating systems, open ports, and service versions.
- Vulnerability scanning function: Can normally create scan tasks, execute host vulnerability scanning, web scanning, weak password scanning, and baseline verification, and output complete scan reports.
- Vulnerability remediation function: For fixable vulnerabilities existing on test systems, can successfully execute automatic remediation; after remediation, re-scanning confirms the vulnerabilities are gone.
- Reporting function: Can generate multiple types of reports, supporting PDF, Word, and Excel format export; report content is complete and accurate.
- Alarm function: After configuring alarm rules, email/Syslog alarms can be sent normally when trigger conditions are met.
- User management: Can create users with different roles, assign different permissions, and permission controls are effective.
- System management: Can perform system configuration, backup and recovery, upgrade operations, and log queries.
16.3.3 Performance Acceptance
- Scanning speed: Under standard configuration, single-IP full-port scan time ≤ 5 minutes, meeting performance parameter requirements.
- Concurrency capability: Supports the maximum concurrent scanning IP count agreed in the contract with stable system operation.
- Response speed: Web management page operations respond smoothly, with page loading time ≤ 3 seconds.
- Stability: Continuous 7-day trial operation with no crashes, restarts, or service abnormalities; system availability rate ≥ 99.9%.
16.3.4 Documentation Acceptance
The following documents must be delivered for acceptance:
- Product quality certificate and warranty card
- Product user manual
- Installation and commissioning report
- System configuration list
- Acceptance test report
- Training records
16.4 Acceptance Process
16.4.1 Acceptance Preparation
- The implementation party submits the acceptance application and complete set of acceptance documentation.
- The user party confirms that acceptance conditions are met and establishes an acceptance team.
- Both parties confirm the acceptance plan and test cases.
16.4.2 On-site Testing
- The acceptance team conducts functional and performance tests item by item according to the test cases.
- Test processes are recorded, and acceptance test forms are filled out.
- Issues found are documented; the implementation party implements on-site rectification or commits to a rectification timeline.
16.4.3 Issue Rectification
- For general issues found during acceptance, the implementation party rectifies within a specified period.
- Re-testing is conducted after rectification is completed.
- For major issues that cannot be resolved promptly, acceptance is postponed until resolved, then re-acceptance is conducted.
16.4.4 Signing the Acceptance Report
- All test items pass and all issues have been rectified.
- Both parties confirm the acceptance results and sign the acceptance report.
- The acceptance report is made in duplicate, with each party retaining one copy; the project is officially delivered.
16.5 Acceptance Determination Criteria
Acceptance results are classified as “Pass” or “Fail”:
- Pass: All key items are qualified, and the general item pass rate is ≥ 95%; sign the acceptance report.
- Fail: Key items have any non-conformances, or the general item pass rate is below 95%; rectify within a specified period and re-accept.
Key items include: hardware configuration conformity, core scanning functions working normally, stable system operation, and valid license.
16.6 Post-Acceptance Handover
After acceptance passes, complete the following handover work:
- Device management authority is formally transferred to the user’s operations team.
- Hand over all documentation, account passwords, and accessories.
- Communicate the subsequent technical support channels and service processes.
- Enter the after-sales maintenance service period.
SEO Optimization System and Keyword Placement
I. Keyword Classification System
1. Core Primary Keywords
Vulnerability scanning and remediation system, vulnerability scanning system, vulnerability remediation system, network security vulnerability scanning, vulnerability scanning device
2. High-Conversion Long-Tail Keywords
Vulnerability scanning and remediation system manufacturer, vulnerability scanning system price, network vulnerability scanning device cost, enterprise-grade vulnerability scanning system, domestic vulnerability scanning system, vulnerability scanning all-in-one appliance, automatic vulnerability remediation system, Classified Protection vulnerability scanning device
3. Industry Traffic Keywords
Network security protection equipment, information security vulnerability scanning, Classified Protection vulnerability scanning, Web vulnerability scanning system, database vulnerability scanning, industrial control vulnerability scanning, host vulnerability scanner, security baseline verification system
4. Brand-Specific Keywords
Lain vulnerability scanning system, Guangdong Lain vulnerability scanning, LA-VS vulnerability scanning device, Lain smart data center security equipment, Lain vulnerability scanning and remediation system
5. Dropdown/Related Search Keywords
Vulnerability scanning system installation tutorial, vulnerability scanning system wiring, vulnerability scanning system commissioning method, vulnerability scanning system common issues, vulnerability scanning system technical parameters, vulnerability scanning system working principle, vulnerability scanning system application scenarios
II. SEO Optimization Tag System
1. Core Page Optimization Tags
- Page topic: Vulnerability Scanning and Remediation System Installation, Wiring, and Commissioning Manual
- Core semantics: Vulnerability scanning device installation, vulnerability remediation system commissioning, network security device operations and maintenance manual
2. Title Tag
Vulnerability Scanning and Remediation System Installation, Wiring, and Commissioning Manual — Complete Tutorial — Guangdong Lain Smart Data Center
3. Meta Keywords
Vulnerability scanning and remediation system, vulnerability scanning system installation, vulnerability remediation system commissioning, network security vulnerability scanning device, vulnerability scanning technical parameters, Lain vulnerability scanning system, Classified Protection vulnerability scanning device
4. Meta Description
Guangdong Lain Smart Data Center professionally provides vulnerability scanning and remediation systems. This manual provides detailed introduction to the vulnerability scanning device including product introduction, principles and parameters, installation and wiring, commissioning methods, maintenance, and common issue resolution, helping enterprises achieve closed-loop management of the full vulnerability lifecycle and meet Classified Protection compliance requirements.
5. H1 Tag
Vulnerability Scanning and Remediation System Installation, Wiring, and Commissioning Manual
6. H2 Tags
Product Introduction, Product Composition, Product Classification, Product List, Product Principles, Product Technical Parameters, Product Functions and Features, Product Application Scenarios, Product Installation, Product Wiring, Product Commissioning, Product Precautions, Product Repair and Maintenance, Product Common Issues and Solutions, Product QA, Product Acceptance
III. Internal Link Optimization Tags (Natural Anchor Text Placement)
1. Core Anchor Text
- Vulnerability Scanning and Remediation System (linking to the main product page)
- Network security protection equipment (linking to the product center homepage)
2. Long-Tail Anchor Text
- Enterprise-grade vulnerability scanning system (linking to the product series page)
- Domestic vulnerability scanning device (linking to the domestic product page)
- Automatic vulnerability remediation system (linking to the function introduction page)
- Classified Protection compliance vulnerability scanning (linking to the industry solution page)
3. Associated Anchor Text
- Micro-module cold aisle (linking to data center infrastructure)
- Shielded data center construction (linking to overall security solutions)
- Smart data center monitoring system (linking to supporting products)
Copyright Notice
The copyright of this document belongs to Guangdong Lain Smart Data Center Equipment Co., Ltd. and is protected by the Copyright Law of the People’s Republic of China. No entity or individual may reproduce, repost, excerpt, modify, or distribute all or part of this document in any form without the written authorization of the company, nor use this document for commercial purposes.
For reposting or citing content from this document, please indicate the source: “Source: Guangdong Lain Smart Data Center Equipment Co., Ltd. Official Website gdlain.com” and retain the complete copyright notice.
Any party violating the above statement will be held legally liable by the company.
The content of this document may be updated without prior notice; the latest version as officially published shall prevail.
Contact Information
- Manufacturer: Guangdong Lain Smart Data Center Equipment Co., Ltd.
- Service Hotline: +86 13538869979 (WeChat same number)
- Technical Support: +86 13538869979
- Company Address: Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou
- Official Website: gdlain.com