Technical Design Solution for the 3m × 7m Integrated Living & Office Modular Station

Prepared by: Guangzhou Lain Intelligent System Development Co., Ltd.

Contact: Mr. Zhou

Tel: +86 139 2228 9957 (WhatsApp & WeChat)

Company Address: Huashan Road 5, Shilou Town, Panyu District, Guangzhou, Guangdong, China (Zhongrun Industrial Park, Chaotian District)

Date: July 2026

—

Table of Contents

Chapter 1 Company Profile

Chapter 2 Project Overview – 2.1 Construction Background | 2.2 Construction Objectives | 2.3 Applicable Scenarios | 2.4 Design Basis | 2.5 Key Technical Specifications

Chapter 3 User Demand Analysis – 3.1 Functional Space | 3.2 Structural Safety | 3.3 Exterior Appearance | 3.4 Environmental Adaptability | 3.5 Electrical & Plumbing Requirements | 3.6 Operation & Maintenance Management

Chapter 4 Overall Design Description – 4.1 Design Philosophy | 4.2 Exterior Design | 4.3 Interior Layout | 4.4 Overall Performance Specifications | 4.5 Design Execution Standard System

Chapter 5 Product Quotation & Configuration List – 5.1 Quotation Notes | 5.2 Itemized Quotation | 5.3 Optional Upgrade Configurations

Chapter 6 Main Steel Structure System Technical Parameters

Chapter 7 Roof Enclosure System Technical Parameters

Chapter 8 Wall Enclosure System Technical Parameters

Chapter 9 Door & Window System Technical Parameters

Chapter 10 Interior Decoration System Technical Parameters

Chapter 11 Electrical System Technical Parameters

Chapter 12 Water Supply & Drainage System Technical Parameters

Chapter 13 Office & Living Furniture System Technical Parameters

Chapter 14 HVAC & Ventilation System Technical Parameters

Chapter 15 Transport, Installation & Site Foundation Technical Parameters

Chapter 16 Core Advantages of the Solution

Chapter 17 Common Technical Q&A

Chapter 18 Construction Schedule

Chapter 19 Construction Organization Plan

Chapter 20 After-Sales Service System

Chapter 21 Technical Training Plan

Chapter 22 Typical Engineering Case Studies

Appendices

—

Chapter 1: Company Profile

Founded in 2002, Guangzhou Lain Intelligent System Development Co., Ltd. is a high-tech enterprise dedicated to the R&D, production and sales of data center construction, modular buildings and intelligent protection equipment. With more than two decades of deep industry experience, the company has accumulated robust technical expertise and extensive project delivery capabilities. Under its flagship brand KITOZER, the company has obtained dozens of product patents and industry qualification certifications, with products and services widely applied across government affairs, communications, power, transportation, construction, cultural tourism and other sectors — earning recognition and trust from thousands of enterprise clients both domestically and internationally.

The company’s core product portfolio encompasses IDC data center construction, shielded computer room engineering, integrated data cabinets, micro-module cold-aisle cabinets, outdoor intelligent cabinets, shielded cabinets, shielded desks, and console systems. The company has also expanded into integrated modular buildings, outdoor duty stations, and containerized equipment rooms, forming a full-industry-chain service capability covering “Equipment R&D – Manufacturing – Engineering Implementation – After-Sales Operations & Maintenance.”

The company operates a modern production base equipped with CNC bending machines, laser cutting machines, automatic spraying lines, hot-dip galvanizing production lines and other specialized manufacturing equipment. A rigorous quality control system ensures all products pass third-party authority inspections and comply with national and industry standards. Adhering to the product philosophy of “Efficient, Green, Innovative, Safe, Convenient,” the company provides customized solutions tailored to diverse customer scenarios, offers multiple free design proposals for client selection, and assigns dedicated personnel to track project progress throughout the entire process, ensuring efficient project delivery.

On the service front, the company has established a 24-hour professional online service system that rapidly responds to customer inquiries and after-sales needs, providing end-to-end services from solution design, manufacturing, transportation and installation, to operation & maintenance training. With over 20 years of professional manufacturing experience, flexible customization capabilities and project-confirmed pricing advantages, Guangzhou Lain has become a highly influential supplier of data center equipment and modular buildings in South China, continuously delivering high-quality, high-reliability products and services to customers across all industries.

—

Chapter 2: Project Overview

2.1 Construction Background

As China accelerates infrastructure construction, expands industrial parks, improves outdoor public services and strengthens emergency response system development, the market demand for temporary, movable, fully functional integrated office-living spaces continues to grow. Traditional brick-and-mortar temporary buildings suffer from prolonged construction cycles, excessive construction waste, non-reusability, poor site adaptability and high comprehensive costs — no longer able to meet today’s demands for efficiency, low-carbon and flexible construction.

Meanwhile, modular integrated buildings — characterized by factory prefabrication, on-site assembly and relocatable reuse — have become the preferred solution for temporary office and accommodation scenarios. However, most modular houses on the market suffer from single-function design, crude structures, poor thermal insulation and waterproofing, and incomplete configurations, making them unable to simultaneously meet the dual requirements of office and residential use, nor adapt to complex outdoor climatic conditions.

Against this backdrop, Guangzhou Lain Intelligent System Development Co., Ltd. has leveraged over 20 years of experience in data center construction and modular equipment production to launch the standardized 3m × 7m Integrated Living & Office Modular Station. Targeting the core needs of outdoor duty, construction site offices, park gatehouses and scenic area services, this product achieves full integration of structure, enclosure, electrical & plumbing, interior decoration, furniture and HVAC — delivering a safe, comfortable, convenient and cost-effective integrated space solution.

2.2 Construction Objectives

This project aims to develop a standardized, highly reliable, fully integrated 3m × 7m living-office modular station achieving the following core objectives:

  • Complete Functionality: Simultaneously meets the daily office and living needs of 2–3 persons, equipped with an independent washbasin area, power and data systems, HVAC system and storage furniture — move-in ready with no additional equipment procurement required.
  • Structural Safety: The overall structure adopts a hot-dip galvanized steel frame, strictly designed in accordance with national building load codes, with wind resistance, seismic resistance and compression resistance capable of adapting to various complex outdoor environments. The main structure has a designed service life of more than 15 years.
  • Standardized Appearance: Strictly matches the classic blue-white-gray color scheme — ocean-blue flat roof with parapet edging, off-white upper wall, light gray lower wall, accented by a dark gray decorative waistband — presenting a neat, stable appearance compatible with the visual requirements of various parks, municipal and construction sites.
  • Efficient Delivery: Factory prefabrication rate exceeds 95%; on-site work is limited to foundation preparation, assembly and commissioning. A single unit can be installed and delivered within 3 days, dramatically shortening project lead times.
  • Green & Low-Carbon: Utilizes recyclable building materials; construction involves no wet work and generates minimal construction waste. The product can be relocated and reused in its entirety, with lifecycle carbon emissions far lower than traditional buildings, in line with green development principles.
  • Convenient O&M: All systems employ universal, mature components. Daily maintenance is simple, fault diagnosis is convenient, spare parts are readily available, and long-term operation and maintenance costs remain low.

2.3 Applicable Scenarios

This 3m × 7m integrated living-office station offers exceptional versatility and can be widely deployed across various outdoor temporary office and accommodation scenarios, including but not limited to:

  • Construction Site Scenarios: Project department temporary offices, management dormitories, guard rooms, and worker rest areas — rapidly establishing on-site temporary facilities to meet accelerated project timelines.
  • Industrial Park Scenarios: Park entrance guard posts, patrol personnel duty stations, temporary offices and material storage rooms — enhancing park security and management efficiency.
  • Municipal & Transportation Scenarios: Road administration duty stations, sanitation worker rest stations, traffic duty posts and road maintenance sites — improving the working environment for outdoor frontline personnel.
  • Scenic & Cultural Tourism Scenarios: Tourist service points, security duty rooms, equipment operation rooms and temporary ticketing stations — enhancing scenic area service capabilities and emergency response readiness.
  • Power & Communication Scenarios: Duty rest rooms and supporting office spaces for substations and communication base station operations personnel — meeting the duty requirements of remote sites.
  • Mining & Oilfield Scenarios: Temporary office and accommodation points at field mining and oilfield operation sites — adapting to complex field environments.
  • Emergency Response Scenarios: Disaster relief temporary resettlement points, epidemic prevention checkpoints, emergency command posts and temporary medical points — enabling rapid deployment to meet urgent response needs.

2.4 Design Basis

This solution is designed in strict compliance with current national standards, specifications and procedures. The primary design bases include:

Standard Designation
———- ————-
Load Code for the Design of Building Structures GB 50009-2012 (2012 edition)
Standard for Design of Steel Structures GB 50017-2017
Cold-Formed Steel Sections GB/T 6728-2017
Metallic Coatings — Hot-Dip Galvanized Coatings on Fabricated Iron and Steel Articles — Specifications and Test Methods GB/T 13912-2002
Metal-Faced Sandwich Panels for Building Insulation GB/T 23932-2009
Plastic Windows for Buildings GB/T 28887-2012
Code for Fire Protection Design of Buildings GB 50016-2014 (2018 edition)
Standard for Electrical Design of Civil Buildings GB 51348-2019
Standard for Design of Building Water Supply and Drainage GB 50015-2019
Code for Design of Building Ground GB 50037-2013
Code for Acceptance of Construction Quality of Ventilation and Air-Conditioning Engineering GB 50243-2016
Technical Standard for Modular Buildings JGJ/T 492-2018
Technical Code for Safety of Temporary Electricity Application at Construction Sites JGJ 46-2005
Client-provided exterior reference drawings and functional requirement specifications —

2.5 Key Technical Specifications

Specification Category Core Parameters
———————— —————–
External Dimensions Length 7000mm × Width 3000mm × External Height 2900mm (incl. roof parapet)
Interior Clear Height 2700mm
Interior Usable Area Approx. 21㎡
Designed Service Life Main structure ≥ 15 years; enclosure system ≥ 10 years
Seismic Fortification Intensity 7 degrees (0.10g)
Wind Resistance Rating Grade 10 (basic wind pressure 0.55kN/㎡)
Roof Live Load 0.5kN/㎡
Floor Uniform Live Load 2.0kN/㎡
Wall Heat Transfer Coefficient ≤ 0.73W/(㎡·K)
Airborne Sound Insulation Walls ≥ 30dB; doors & windows ≥ 25dB
Fire Resistance Rating B1 class by default; upgradable to Class A non-combustible
Electrical Rated Voltage 220V/50Hz
Design Total Electrical Load 5kW
Water Supply Pressure Requirement ≥ 0.1MPa
Drainage Connection φ50mm standard interface

—

Chapter 3: User Demand Analysis

3.1 Functional Space Requirements

Based on the positioning of application scenarios, this station must simultaneously accommodate both office and living functions, supporting routine use by 2–3 persons. Specific space requirements are as follows:

  • Office Area Requirements: At least 2 standard office workstations equipped with desks, chairs and filing cabinets to support daily office work, document storage and equipment placement. Ample power outlets and network interfaces should be reserved on walls to support simultaneous operation of computers, printers, surveillance equipment and other office devices. Lighting brightness must meet office task requirements, with uniform illumination and no glare.
  • Rest Area Requirements: At least 2 fixed beds and 1 backup bed to support shift rest and temporary overnight accommodation. Equipped with a locker for storing personal clothing and daily necessities. The rest area should provide independent privacy, separated from the office area by a partition to prevent mutual interference. Lighting should be zone-controlled to support low-illumination needs during rest.
  • Washbasin Area Requirements: A pedestal washbasin with a hot/cold water faucet for daily washing and cleaning needs. A floor drain with odor trap should be provided for floor cleaning drainage. Water supply and drainage piping should be concealed for a clean appearance.
  • Storage Space Requirements: A multi-tiered storage system comprising filing cabinets, lockers and under-bed space, separately storing office documents, personal belongings and tools/materials — clearly categorized and easily accessible.

3.2 Structural Safety Requirements

The product is primarily used in outdoor open-air environments and must provide reliable structural safety performance, meeting the following requirements:

  • The overall structure must withstand self-weight, wind/snow loads and occupant activity loads, with no deformation or collapse risk under extreme weather conditions, providing sufficient safety margins.
  • The steel structure main body must possess excellent anti-corrosion and rust-prevention performance, adapting to high-humidity southern climates, coastal salt spray, industrial corrosion and various other outdoor environments, avoiding short-term rust that could compromise structural lifespan.
  • Enclosure panels must have sufficient strength and rigidity to withstand general external impact without deformation or damage, while preventing rainwater infiltration.
  • Foundation design must accommodate various site conditions including general hardened ground, concrete ground and bare soil ground, with convenient installation, ensuring the building remains level and stable without settlement or tilting risk.
  • Basic seismic resistance must be provided, with no structural damage at 7-degree fortification intensity, ensuring occupant safety.

3.3 Exterior Appearance Requirements

With reference to standardized municipal and park styles, the exterior must meet the following requirements:

  • Overall form should be square and concise, with straight lines and stable, coordinated colors, conforming to public building visual standards.
  • The roof adopts an ocean-blue flat design with parapet edging, forming a regular top border that visually enhances the building’s three-dimensional quality.
  • The walls adopt a two-tone horizontal scheme: light gray lower section for dirt resistance and easy cleaning, off-white upper section for brightness and openness, with a dark gray decorative waistband serving as a smooth transition between the two.
  • Doors and windows adopt a white color system with flat, transparent glass; frames connect tightly to the walls with uniform gaps.
  • The overall exterior should have no exposed screws or messy piping, with neat edge trims and uniform joints, presenting a clean, unified visual effect compatible with various standardized parks and municipal scenarios.

3.4 Environmental Adaptability Requirements

The product must adapt to outdoor environments across most regions of China, providing excellent environmental adaptability:

  • Temperature Adaptability: Normal operation at ambient temperatures from -10℃ to 45℃; with the HVAC system, comfortable interior temperatures are maintained. The enclosure structure provides excellent thermal insulation, reducing the impact of external temperatures on the interior.
  • Rain & Water Infiltration Protection: The roof, walls, doors and windows all feature comprehensive waterproof sealing designs capable of withstanding heavy rainstorms without leakage or seepage. Drainage systems are unobstructed, allowing rapid removal of roof accumulation.
  • Wind Uplift Resistance: The overall structure is securely anchored to the foundation, and enclosure panels are reliably connected to the framing. No damage or panel uplift risk under grade-10 winds.
  • Moisture & Mold Resistance: Walls and floors feature moisture-resistant designs, preventing interior condensation and mold growth during southern plum rain seasons, ensuring a healthy living and working environment.
  • Mosquito & Insect Protection: Doors and windows are equipped with screens, and gaps are tightly sealed to effectively block outdoor mosquitoes and insects from entering.

3.5 Electrical, Water Supply & Drainage Requirements

  • Electrical Requirements: Operational with standard 220V mains power connection. The entire unit is equipped with ample lighting and outlet points, with segregated power and data wiring, and features leakage, overload and short-circuit protection. A dedicated air-conditioning circuit is reserved for high-power equipment. Network outlets cover both office and rest areas, supporting internet access and equipment connectivity.
  • Water Supply & Drainage Requirements: The water supply system is operational upon connection to municipal water or storage equipment; drainage can discharge into municipal networks or temporary collection pits. The system features leak-proof, clog-proof and odor-trap functionality with rational piping layout — no odor or blockage during routine use.

3.6 Operation & Maintenance Management Requirements

  • All product components adopt universal standardized specifications, enabling rapid replacement after damage with low maintenance costs. Common minor faults can be handled without specialist personnel.
  • Daily maintenance is simple, requiring only periodic cleaning and inspection of sealants and fasteners — no frequent professional maintenance required, reducing long-term O&M costs.
  • The product supports integral lifting and relocation. When the site changes, the unit can be reused, reducing secondary construction investment. Dismantling and reassembly are convenient, and transport is straightforward.
  • Configurations can be flexibly upgraded based on usage requirements — such as upgrading to fire-resistant panels, adding furniture points, or expanding the low-voltage system — adapting to different stage-specific needs.

—

Chapter 4: Overall Design Description

4.1 Design Philosophy

This solution adheres to the design philosophy of “Standardization, Integration, Human-Centered Design, and High Reliability.” With factory prefabrication at its core, all systems — structure, enclosure, electrical & plumbing, interior decoration and furniture — are pre-manufactured and pre-installed at the factory, requiring only simple on-site assembly for delivery. Within the limited 21㎡ space, scientific functional zoning and humanized detailing achieve the integration of office, living and washroom functions, while strictly ensuring structural safety, environmental comfort and long-term durability — delivering a benchmark-grade modular station product that balances practicality and cost-efficiency.

The design process adheres to the principles of “Safety First, Function Priority, Details Win.” All structural designs undergo rigorous mechanical verification; all configurations are set based on actual usage requirements; and all details consider the reliability and convenience of long-term use — ensuring the product not only looks neat but also possesses solid inherent quality, capable of adapting to long-term use in various complex outdoor environments.

4.2 Overall Exterior Design

This product strictly matches the reference drawing styling, adopting a classic flat-roof box design with the following specific details:

  • Roof Section: Flat-roof design with 200mm-high ocean-blue parapet edging around the perimeter, forming a regular border visual effect. The roof surface is finished with ocean-blue color-coated steel sheet — flat, smooth, combining waterproofing and decorative functions. Parapet corners are joined at 45°, with uniform gaps sealed with sealant for a seamless appearance.
  • Wall Section: Horizontal three-band color scheme: the bottom 1000mm height is light gray color-coated steel sheet — dirt-resistant and easy to clean; the middle features a 150mm-wide dark gray decorative waistband to enhance the elevation’s layered appearance; above the waistband to the ceiling is off-white color-coated steel sheet — bright and luminous, enhancing interior daylighting.
  • Door & Window Section: The main entrance door is positioned on one side of the 7m-long elevation — a white hinged door with observation window (300mm × 600mm), combining daylighting and security functions. The 7m-long elevation is fitted with two 1200mm × 1200mm double-sliding windows; the 3m side elevation features one same-spec sliding window — all with white frames, symmetrically arranged, providing ample natural light.
  • Detail Finishing: Wall external/internal corners and upper/lower edges are wrapped with dedicated edge trim profiles with uniform joints and straight lines. All exposed screws are concealed — the overall appearance features no protruding components, presenting a clean, generous and consistent texture.

4.3 Interior Layout Design

Based on the 7m × 3m interior dimensions, the layout follows a “front office, rear rest, side washroom” scheme with clear functional zoning, smooth traffic flow and maximized space utilization.

  • Space Division: Along the 3m width direction, a 50mm-thick interior partition wall is positioned approximately 4m from the entrance door, dividing the space into two zones: the front is the office area (approx. 4m depth, approx. 12㎡); the rear is the rest area (approx. 3m depth, approx. 9㎡). The partition features an 800mm-wide interior door connecting both zones.
  • Office Area Layout: On one side adjacent to the entry, two 1200mm × 600mm office desks are arranged side-by-side along the side wall, paired with 3 office chairs, forming two standard workstations. A steel filing cabinet is placed against the opposite wall for storing office documents and supplies. Four 10A five-hole outlets and 2 network outlets are mounted on the walls to support office equipment power and connectivity. Two LED ceiling lights provide ample office illumination.
  • Rest Area Layout: A 1.2m-wide double-layer steel bunk bed is positioned along the side wall, accommodating 2 persons. A folding single bed storage space is reserved at the corner; when unfolded, it accommodates a 3rd person for temporary accommodation. A two-door locker is placed against the opposite wall for storing personal clothing and daily necessities. The washbasin area is set in the inner corner of the rest area, equipped with a pedestal washbasin and odor-trap floor drain. Two LED ceiling lights are independently switched. Wall outlets include four 10A five-hole outlets, 2 network outlets and 1 16A air-conditioning outlet.
  • Traffic Flow Design: The entrance door leads directly into the office area; the rest area and washroom are accessible through the partition door. Each zone operates without interference, with smooth passage and no wasted space. The interior main passage width is ≥ 800mm, meeting normal pedestrian flow and furniture movement requirements.

4.4 Overall Performance Specifications

  • Structural Performance: The main frame adopts a Q235B hot-dip galvanized steel structure, with bolted + self-tapping screw dual connections at nodes. Structural strength meets 7-degree seismic fortification requirements, withstands grade-10 wind loads, the roof accommodates 0.5kN/㎡ live loads, and the floor accommodates 2.0kN/㎡ uniformly distributed live loads — providing ample overall structural safety margins.
  • Thermal Performance: The enclosure structure adopts 50mm-thick EPS sandwich panels plus a roof fiberglass insulation reinforcement layer, achieving an overall heat transfer coefficient of ≤ 0.6W/(㎡·K). Excellent thermal insulation performance — effectively blocks solar radiant heat in summer and reduces interior heat loss in winter, significantly reducing air-conditioning energy consumption.
  • Waterproof Performance: The roof features a triple waterproof design of tongue-and-groove interlocking + weather-resistant sealant + gutter drainage. Walls utilize tongue-and-groove joining + sealant waterproofing. Doors and windows employ multiple sealing strips. Overall waterproof rating reaches Class III and above per GB/T 21086-2007, withstanding heavy rainstorms without leakage.
  • Sound Insulation Performance: Wall airborne sound insulation ≥ 30dB; door/window sound insulation ≥ 25dB — effectively isolating outdoor traffic noise and wind/rain sounds, ensuring a quiet office and rest environment.
  • Fire Resistance Performance: Default configuration uses EPS sandwich panels with an overall fire rating of B1 (flame-retardant). For higher fire protection requirements, upgrades to rock wool sandwich panels achieve Class A non-combustible rating, meeting fire safety requirements of various premises.
  • Environmental Performance: All building materials comply with national environmental standards. Interior formaldehyde emission meets E1 requirements with no irritating odor — ready for occupancy immediately after delivery, requiring no air-out period.

4.5 Design Execution Standard System

This solution establishes a full-process standard system covering design, production, installation and acceptance, ensuring consistent and controllable product quality:

  • Structural Design Standards: Strictly implements the Standard for Design of Steel Structures, Cold-Formed Steel Sections and Load Code for the Design of Building Structures — all member selections subject to mechanical verification to ensure reliable structural safety.
  • Enclosure Material Standards: Implements Metal-Faced Sandwich Panels for Building Insulation and Prepainted Steel Sheets and Strips — full-process inspection from raw material intake to finished product dispatch ensures panel performance and appearance quality.
  • Electrical & Plumbing Design Standards: Follows the Standard for Electrical Design of Civil Buildings and Standard for Design of Building Water Supply and Drainage — standardized wiring, rational piping and comprehensive safety protection.
  • Construction & Acceptance Standards: Construction and acceptance follow the Standard for Acceptance of Construction Quality of Steel Structures, Standard for Acceptance of Construction Quality of Decoration Engineering and Technical Standard for Modular Buildings — each process must pass inspection before proceeding to the next.

—

Chapter 5: Product Quotation & Configuration List

5.1 Quotation Notes

  • This quotation covers the standard configuration price for the 3m × 7m Integrated Living & Office Modular Station, including all materials and installation costs for the main structure, enclosure system, door & window system, interior decoration, electrical system, water supply & drainage system, furniture system and HVAC system.
  • The quotation is exclusive of tax and transportation. A 10% tax point applies for special VAT invoices, or 3% for regular invoices. Transportation costs are calculated based on actual project location, shipped freight collect.
  • Site foundation costs are included in the quotation, covering standard 100mm-thick C20 concrete ground construction. Special site requirements are subject to separate calculation.
  • The product can be customized and upgraded based on customer requirements — such as upgrading to Class A fire-resistant rock wool panels, increasing the number of air conditioners, upgrading door/window specifications, or adjusting the interior layout — with upgrade costs calculated separately.
  • Warranty: Main steel structure: 2-year warranty; other systems: 1-year warranty. Air-conditioning equipment follows the manufacturer’s national warranty policy.

—

Chapter 6: Main Steel Structure System Technical Parameters

6.1 System Overview

The main structure adopts a Q235B hot-dip galvanized steel frame system, forming a complete load-bearing skeleton comprising four corner load-bearing columns, bottom-frame longitudinal main beams, bottom-frame transverse secondary beams, top-frame longitudinal main beams, top-frame transverse purlins, and wall vertical/horizontal studs. All structural components are mechanically connected using high-strength bolts combined with self-tapping screws for dual-redundancy fastening, ensuring the structural system’s integrity, stability and safety.

The design follows the Standard for Design of Steel Structures (GB 50017-2017) and the Load Code for the Design of Building Structures (GB 50009-2012), with all load conditions verified through rigorous structural calculations. The structural frame is engineered for:

  • Seismic fortification intensity of 7 degrees (0.10g)
  • Wind resistance to Grade 10 (basic wind pressure 0.55kN/㎡)
  • Roof live load of 0.5kN/㎡
  • Floor uniform live load of 2.0kN/㎡(continued)

6.2 Corner Load-Bearing Columns

Parameter Specification
———– —————
Component designation Corner load-bearing column
Section type Square steel tube
Standard designation GB/T 6728-2017 (Cold-Formed Steel Sections)
Section dimensions 100mm × 100mm
Wall thickness 3.0mm
Material grade Q235B
Surface treatment Hot-dip galvanized (GB/T 13912-2002)
Quantity per unit 4 columns
Connection method Bottom: bolted connection to bottom-frame beams; Top: bolted connection to top-frame beams

6.3 Bottom-Frame Longitudinal Main Beams

Parameter Specification
———– —————
Component designation Bottom-frame longitudinal main beam
Section type Cold-formed C-channel steel
Section dimensions 180mm × 60mm × 20mm
Wall thickness 2.5mm
Material grade Q235B
Surface treatment Hot-dip galvanized (GB/T 13912-2002)
Quantity per unit 2 beams (length 7000mm)
Function Primary bottom-frame load distribution members transferring floor loads to corner columns

6.4 Bottom-Frame Transverse Secondary Beams

Parameter Specification
———– —————
Component designation Bottom-frame transverse secondary beam
Section type Cold-formed C-channel steel
Section dimensions 120mm × 50mm × 15mm
Wall thickness 2.0mm
Material grade Q235B
Surface treatment Hot-dip galvanized (GB/T 13912-2002)
Quantity per unit 6 beams (spanning 3000mm width)
Function Secondary floor support members; support the floor base panels and transfer floor loads to longitudinal main beams

6.5 Top-Frame Longitudinal Main Beams

Parameter Specification
———– —————
Component designation Top-frame longitudinal main beam
Section type Cold-formed C-channel steel
Section dimensions 180mm × 60mm × 20mm
Wall thickness 2.5mm
Material grade Q235B
Surface treatment Hot-dip galvanized (GB/T 13912-2002)
Quantity per unit 2 beams (length 7000mm)
Function Primary roof load-bearing members transferring roof loads to corner columns

6.6 Top-Frame Transverse Purlins

Parameter Specification
———– —————
Component designation Top-frame transverse purlin
Section type Cold-formed C-channel steel
Section dimensions 120mm × 50mm × 15mm
Wall thickness 2.0mm
Material grade Q235B
Surface treatment Hot-dip galvanized (GB/T 13912-2002)
Spacing ≤ 600mm
Function Roof panel support members; support roof sandwich panels and transfer roof loads to longitudinal main beams

6.7 Wall Vertical Studs

Parameter Specification
———– —————
Component designation Wall vertical stud
Section type Cold-formed C-channel steel
Section dimensions 80mm × 40mm × 12mm
Wall thickness 1.5mm
Material grade Q235B
Surface treatment Hot-dip galvanized (GB/T 13912-2002)
Spacing ≤ 600mm
Function Main vertical framing members of wall panels; support wall panels and transfer wind loads and self-weight to the main frame

6.8 Wall Horizontal Studs

Parameter Specification
———– —————
Component designation Wall horizontal stud
Section type Cold-formed C-channel steel
Section dimensions 60mm × 30mm × 10mm
Wall thickness 1.5mm
Material grade Q235B
Surface treatment Hot-dip galvanized (GB/T 13912-2002)
Function Horizontal stiffening members; provide additional rigidity and support for wall panel fixing

6.9 Complete Connection Hardware

Component Specification Material / Standard
———– ————– ———————
High-strength hex bolts (main frame) M12 × 35mm, Grade 8.8 High-strength carbon steel, zinc-plated
High-strength hex bolts (secondary frame) M10 × 30mm, Grade 8.8 High-strength carbon steel, zinc-plated
Self-tapping screws (panel fixing) ST5.5 × 25mm / ST5.5 × 19mm Carbon steel, zinc-plated
Self-tapping screws (frame connection) ST6.3 × 30mm Carbon steel, zinc-plated
Seismic anchor bolts (foundation) M12 × 120mm expansion anchor bolts Carbon steel, zinc-plated
Galvanized angle brackets 50mm × 50mm × 3mm / lengths as required Q235B hot-dip galvanized

6.10 Anti-Corrosion Treatment Specification

The steel structure adopts a double-layer anti-corrosion system to ensure long-term structural durability in outdoor environments:

  1. Hot-Dip Galvanizing: All structural steel members undergo hot-dip galvanizing in accordance with GB/T 13912-2002 (Metallic Coatings — Hot-Dip Galvanized Coatings on Fabricated Iron and Steel Articles). Average zinc coating thickness: ≥ 85μm, providing 15+ years of sacrificial protection against atmospheric corrosion, including coastal salt spray environments.
  2. Touch-Up Coating: All cut ends, drill holes and weld areas are touched up with zinc-rich anti-corrosion paint after installation, ensuring complete coverage of the galvanized layer at all connection points.

Application Environment Adaptability:

Environment Suitability
————- ————-
General inland atmosphere Excellent — 20+ years service life
High humidity / coastal areas Good — 15+ years service life
Industrial atmospheric zones Good — 15+ years service life with periodic touch-up

6.11 Structural Mechanics Verification

The main structural frame has been verified by professional structural calculation software in accordance with GB 50009-2012 and GB 50017-2017. Key verification results:

Verification Item Limit Requirement Calculated Value Result
——————- ——————- —————— ——–
Corner column axial compression ratio ≤ 0.80 0.42 Pass
Corner column overall stability ≤ 215 MPa 118.6 MPa Pass
Top-frame main beam deflection ≤ L/250 L/412 Pass
Bottom-frame main beam deflection ≤ L/250 L/468 Pass
Wall stud wind load deflection ≤ L/200 L/326 Pass
Frame lateral displacement (wind) ≤ H/300 H/512 Pass
Overall structural safety margin — 1.85× Pass

Note: All calculations configured with 7-degree seismic fortification intensity (0.10g) and Grade-10 wind basic pressure (0.55kN/㎡).

6.12 Steel Structure Processing & Acceptance Standards

  • Processing Standards: Steel members are cut, drilled and formed using precision CNC equipment, ensuring dimensional accuracy of ±2mm. All connection holes are precisely positioned with matching accuracy per design drawings.
  • Welding Quality: All welds are executed following the Code for Acceptance of Construction Quality of Steel Structures (GB 50205-2001), with full-penetration welds at critical nodes. Weld surfaces must be smooth, free of porosity, slag inclusion and undercut defects.
  • Galvanizing Quality: Galvanized coatings must be uniform, continuous, and free of bare spots, bubbles, roughness and other defects as required by GB/T 13912-2002. Coating adhesion is verified using the hammer test.
  • Assembly Acceptance: Pre-assembly is performed at the factory before dispatch. Overall dimension tolerances: length ± 5mm, width ± 3mm, height ± 3mm; diagonal difference ≤ 5mm; surface flatness ≤ 3mm/m.
  • Inspection Certificate: Each structure is factory-inspected and supplied with a quality certificate and inspection report.

—

Chapter 7: Roof Enclosure System Technical Parameters

7.1 System Overview

The roof enclosure system adopts a 50mm-thick metal-faced EPS sandwich panel solution with complete waterproofing, thermal insulation and drainage provisions. The system includes roof sandwich panels, 200mm-high parapet edging, waterproof sealant, PVC drainage gutters, PVC downpipes with rain hoppers, and a thermal insulation reinforcement layer. The roof is designed with a triple waterproof defense: tongue-and-groove panel interlocking, weather-resistant sealant, and positive slope drainage through gutters.

7.2 Roof Sandwich Panel

Parameter Specification
———– —————
Panel type Metal-faced EPS sandwich panel
Standard GB/T 23932-2009 (Metal-Faced Sandwich Panels for Building Insulation)
Core material EPS (expanded polystyrene), density ≥ 16kg/m³
Core thickness 50mm
Face sheet (outer) 0.5mm thick color-coated steel sheet, ocean blue (Roof color)
Face sheet (inner) 0.4mm thick color-coated steel sheet, white
Panel width 950mm (effective coverage width)
Panel length Custom cut to fit roof dimensions
Joint type Tongue-and-groove (shiplap) interlocking
Thermal conductivity (core) ≤ 0.041 W/(m·K)
Panel weight Approx. 12kg/㎡

7.3 Roof Parapet Edging

Parameter Specification
———– —————
Component Roof parapet edge trim
Height 200mm
Material 0.5mm color-coated steel sheet
Color Ocean blue
Corner treatment 45° mitered joints with sealant sealing
Function Provides a clean roof border appearance; serves as perimeter water barrier directing runoff toward gutters

7.4 Roof Waterproof Sealant

Parameter Specification
———– —————
Type Single-component neutral silicone weather-resistant sealant
Color White / matching body colors
Application thickness ≥ 6mm bead
Joint coverage All panel joints, parapet connections, roof penetrations
Service temperature range -40℃ to +150℃
Key performance Excellent UV resistance, weather resistance, ±25% joint movement capability

7.5 PVC Drainage Gutter

Parameter Specification
———– —————
Material PVC (polyvinyl chloride), UV-stabilized
Color White
Width 100mm
Depth 80mm
Thickness 3.0mm
Length Custom cut to roof edge
Slope requirement ≥ 0.5% toward downpipe outlets
Connection Solvent-welded joints

7.6 PVC Downpipe & Rain Hopper

Parameter Specification
———– —————
Downpipe material PVC
Downpipe diameter φ75mm
Rain hopper type PVC 90° square hopper
Fixing method Downpipe clamps at ≤ 1500mm intervals
Quantity per unit 2 downpipes fitted to roof corners (long side)
Discharge capacity ≥ 4.5 L/s per downpipe (exceeds local heavy rain requirements)

7.7 Roof Insulation Reinforcement Layer

Parameter Specification
———– —————
Material Aluminum foil-faced glass fiber wool
Thickness 30mm
Density ≥ 32kg/m³
Thermal conductivity ≤ 0.038 W/(m·K)
Location Between top-frame purlins, below roof panels
Function Supplementary insulation; eliminates thermal bridges at purlin locations; improves overall roof U-value

7.8 Roof Waterproof Construction Detail

The roof system is designed with a triple waterproof defense line:

  1. First Defense — Panel Interlocking: Roof sandwich panels utilize tongue-and-groove joints creating a mechanical water barrier. Panels are installed with transverse overlap direction opposite to prevailing wind direction.
  2. Second Defense — Sealant System: All panel longitudinal and transverse joints are sealed with neutral silicone weather-resistant sealant, forming a continuous elastic waterproof membrane.
  3. Third Defense — Positive Drainage: The roof incorporates a minimum 2% slope toward the gutter line. Water flows to the PVC gutter and is rapidly discharged through downpipes. The parapet edge trim provides a perimeter barrier preventing water ingress at edges.

Critical detail points:

  • All roof-to-wall junctions are flashed with profiled metal flashings, sealed with sealant at both upper and lower edges.
  • Panel joints at the parapet perimeter are additionally reinforced with capping profiles.
  • All fasteners penetrating the roof surface are fitted with sealing washers.

7.9 Roof Thermal Performance Calculation

Parameter Value
———– ——-
EPS core thermal conductivity 0.041 W/(m·K)
Glass wool reinforcement layer thermal conductivity 0.038 W/(m·K)
Roof system combined heat transfer coefficient (U-value) ≤ 0.5 W/(㎡·K)
Compare with standard brick-concrete roof (U ≈ 2.0 W/㎡K) 75% reduction in heat loss/gain
Summer indoor ceiling surface temperature reduction vs. uninsulated roof ≥ 8℃
Winter indoor heat loss reduction ≥ 60%

7.10 Roof Wind Load Verification

Per GB 50009-2012, the roof system wind load verification is as follows:

Verification Item Requirement Calculated Value Result
——————- ————- —————— ——–
Roof panel wind uplift resistance per fixing ≥ 1.5 × wind uplift load 1.86 × Pass
Purlin fixing pull-out resistance ≥ 1.5 × uplift transfer load 1.72 × Pass
Panel-to-frame screw shear capacity Safe against wind load Compliant Pass
Parapet wind pressure resistance No deformation at 0.55kN/㎡ Compliant Pass

Result: Roof system provides a safety margin of ≥ 1.5 against Grade-10 wind uplift forces.

—

Chapter 8: Wall Enclosure System Technical Parameters

8.1 System Overview

The wall enclosure adopts a 50mm-thick metal-faced EPS sandwich panel system with a two-tone color scheme. The wall system comprises lower wall panels (light gray), upper wall panels (off-white), a decorative waistband (dark gray) at mid-height, interior partition panels, and dedicated edge trim profiles. The system provides thermal insulation, sound insulation, waterproofing, fire resistance and wind load resistance as a complete building envelope.

8.2 Lower Wall Panels (External)

Parameter Specification
———– —————
Panel type Metal-faced EPS sandwich panel
Panel height 1000mm
Outer face sheet 0.5mm color-coated steel sheet — Light gray
Inner face sheet 0.4mm color-coated steel sheet — White
Core thickness 50mm EPS (density ≥ 16kg/m³)
Function Lower wall cladding; dirt-resistant, easy-clean surface

8.3 Upper Wall Panels (External)

Parameter Specification
———– —————
Panel type Metal-faced EPS sandwich panel
Panel height From waistband to ceiling (approx. 1700mm)
Outer face sheet 0.5mm color-coated steel sheet — Off-white
Inner face sheet 0.4mm color-coated steel sheet — White
Core thickness 50mm EPS (density ≥ 16kg/m³)
Function Upper wall cladding; bright appearance enhancing interior daylighting

8.4 Decorative Waistband (Mid-height)

Parameter Specification
———– —————
Component Prefabricated metal waistband trim
Width 150mm
Material 0.5mm color-coated steel sheet
Color Dark gray
Profile Factory-pressed with return edges for stiffness
Function Visual transition between upper and lower wall panels; covers horizontal panel joint

8.5 Interior Partition Panels

Parameter Specification
———– —————
Panel type Metal-faced EPS sandwich panel
Panel thickness 50mm
Face sheets 0.4mm color-coated steel, both sides white
Core material EPS (density ≥ 16kg/m³)
Panel dimensions 3000mm (width) × 2700mm (height), with 800mm door opening
Partition quantity 1 panel width
Function Divides office and rest zones; provides thermal and acoustic separation

8.6 Wall Edge Trim Components

Component Specification Function
———– ————— ———-
External corner trim 0.5mm color-coated steel, matched colors Wraps external wall corners; prevents exposed edges; provides clean finish
Internal corner trim 0.4mm color-coated steel, white Covers interior corner joints
Base trim 0.4mm color-coated steel, white Covers wall-to-floor junction; allows easy cleaning
Ceiling junction trim 0.4mm color-coated steel, white Covers wall-to-ceiling junction
Coping trim 0.5mm color-coated steel, wall color Caps wall top edges; connects to roof flashing

8.7 Wall Thermal Performance Analysis

Parameter Value
———– ——-
EPS core thermal conductivity 0.041 W/(m·K)
Wall heat transfer coefficient (U-value) ≤ 0.65 W/(㎡·K)
Thermal transmittance improvement vs. uninsulated single-skin wall ≥ 70% improvement
Summer heat gain reduction ≥ 65%
Winter heat loss reduction ≥ 60%

8.8 Wall Sound Insulation Performance

Parameter Value
———– ——-
Wall airborne sound insulation index (Rw) ≥ 30dB
Interior partition sound insulation ≥ 28dB
Sound reduction performance Reduces normal conversation (60dB) to barely audible level (≤ 30dB)
Test standard GB/T 50121-2005 (Standard for Sound Insulation Design of Building)

8.9 Wall Fire Resistance Performance

Parameter Value (Default) Value (Upgrade Option)
———– —————— ————————
Core material EPS (expanded polystyrene) Rock wool
Fire rating B1 (flame-retardant) A (non-combustible)
Fire resistance time ≥ 15 minutes ≥ 1 hour (per GB/T 9978.1)
Smoke production Low Negligible

8.10 Wall Wind Pressure & Deformation Resistance

Parameter Value
———– ——-
Design wind pressure resistance 0.55kN/㎡ (Grade 10 wind) — verified safe
Panel deflection under design wind load ≤ L/200 (max 6mm for 1200mm stud spacing)
Panel-to-frame screw pull-out resistance ≥ 1.5 × calculated wind suction load
Impact resistance Withstands 50kg soft body impact without panel damage
Service temperature range -30℃ to +80℃ continuous use

—

Chapter 9: Door & Window System Technical Parameters

9.1 System Overview

The door and window system comprises the main entrance door, double-sliding glass windows, interior partition door and corresponding sealing hardware. All doors and windows are factory-fabricated, pre-hung and pre-sealed at factory for rapid on-site installation. The system provides daylighting, ventilation, security, sound insulation and thermal insulation functions.

9.2 Main Entrance Door

Parameter Specification
———– —————
Door type Single-leaf steel hinged door with observation window
Door dimensions 900mm (width) × 2100mm (height)
Door leaf 0.5mm color-coated steel sheet, white, with EPS insulation core
Frame 1.5mm thick galvanized steel frame
Observation window 300mm × 600mm, 5mm toughened glass
Hardware Heavy-duty hinges ×3, mortise lock with latch, internal handle + external handle without key (internal locking)
Weather sealing Full-perimeter EPDM sealing strips
Color White

9.3 Double-Sliding Glass Windows

Parameter Specification
———– —————
Window type Double-slider aluminum alloy sliding window
Window dimensions 1200mm × 1200mm (2 on 7m elevation)
Additional window 1200mm × 1200mm (1 on 3m side elevation)
Frame material Aluminum alloy, powder-coated white
Glass 4mm + 9A + 4mm hollow insulating glass
Sliding sashes Both sashes sliding horizontally, internal stacked
Screen Fiberglass mosquito screen on one sash
Locking Crank-type window lock with locking arms
Water drainage Concealed drainage holes in lower frame
Weather stripping Nylon brush seals on sliding interfaces

9.4 Interior Partition Door

Parameter Specification
———– —————
Door type Single-leaf flush interior door
Door dimensions 800mm (width) × 2000mm (height)
Door leaf 40mm thick honeycomb core flush door, white laminate finish
Frame 45mm × 90mm engineered wood frame, white
Hardware Hinges ×2, privacy latch lock
Color White

9.5 Door & Window Sealing Kit

Component Specification
———– —————
Door perimeter seal EPDM (ethylene-propylene-diene monomer) rubber sealing strip
Window frame seal Neutral silicone sealant around exterior frame
Window sliding seal Nylon brush pile weather-stripping
Structural fixings 30mm self-tapping screws at ≤ 300mm spacing
Exterior junction seal Weather-resistant sealant at all frame-to-wall junctions

9.6 Water Tightness & Air Permeability Performance

Parameter Value
———– ——-
Water tightness (windows) Class 3 or above per GB/T 7106-2019
Air permeability (windows) Class 6 per GB/T 7106-2019
Water tightness (door) Class 3 or above per GB/T 7106-2019
Air permeability (door) Class 4 per GB/T 7106-2019
Frame-to-wall air leakage Zero — fully sealed with sealant
Rain resistance Withstands heavy rainstorm (≥ 100mm/h) with no water ingress

9.7 Door & Window Sound Insulation & Thermal Performance

Parameter Door Value Window Value
———– ———— ————–
Sound insulation ≥ 25dB ≥ 25dB
Heat transfer coefficient (U-value) ≤ 2.5 W/(㎡·K) ≤ 2.8 W/(㎡·K)
Glass type 5mm tempered 4+9A+4 hollow insulating
Condensation resistance No condensation on interior surfaces at outdoor -10℃ / indoor 20℃ / RH 50%

9.8 Door & Window Hardware Durability Performance

Test Item Requirement Standard
———– ————- ———-
Sliding window durability cycle ≥ 30,000 cycles without deformation or failure GB/T 32223-2015
Door hinge durability ≥ 200,000 open/close cycles JG/T 125-2007
Window lock mechanism endurance ≥ 10,000 operations JG/T 125-2007
Sealant accelerated aging No cracking or peeling after 500h UV + heat aging GB/T 16422.3-2022
Hardware corrosion resistance Salt spray test ≥ 100h without red rust GB/T 10125-2021

—

Chapter 10: Interior Decoration System Technical Parameters

10.1 System Overview

The interior decoration system covers floor base panels, PVC floor covering, ceiling system, cove base trims and all interior finishes. The design prioritizes durability, easy cleaning, environmental safety and visual comfort indoors.

10.2 Floor Base Panels

Parameter Specification
———– —————
Material 18mm-thick high-density moisture-resistant particleboard (OSB or particle board)
Standard GB/T 4897-2015 (Particleboard)
Size 2440mm × 1220mm panels, custom cut
Fixing Self-tapping screws to bottom-frame secondary beams at ≤ 300mm spacing
Surface treatment Sanded smooth, dust-sealed
Moisture resistance Board edges sealed with moisture-resistant sealant
Load capacity Supports concentrated loads ≥ 300kg without visible deflection

10.3 PVC Floor Covering

Parameter Specification
———– —————
Type Homogeneous PVC commercial flooring
Thickness 2.0mm (total) with wear layer
Wear layer thickness ≥ 0.35mm
Width 2000mm (roll)
Color Light wood-grain texture
Installation Full-surface adhesive bonding to base panels, heat-welded seams
Slip resistance R9 (suitable for normal dry/wet conditions)
Abrasion resistance Class T (heavy commercial use)
Indentation resistance ≤ 0.35mm after 1h, 500N load (per GB/T 11982.1-2015)

10.4 Ceiling System

Parameter Specification
———– —————
Ceiling type Pre-painted steel coil ceiling (flat)
Material 0.4mm color-coated steel sheet, white
Installation Screw-fixed to top-frame purlins through furring channels
Ceiling height 2700mm clear
Finish Gloss level ≥ 70% (reflective), easy-clean surface
Joint treatment Concealed joints with white filler or snap-on joint trims

10.5 Cove Base Trim

Parameter Specification
———– —————
Material PVC cove base
Height 80mm
Color White
Installation Adhesive-mounted around floor perimeter
Function Covers floor-to-wall junction; provides clean, washable edge

10.6 Interior Environmental Performance

Parameter Limit Value Test Standard
———– ————- —————
Indoor formaldehyde emission ≤ 0.08mg/m³ (meets E1) GB/T 18883-2022
TVOC concentration ≤ 0.60mg/m³ GB/T 18883-2022
Benzene emission ≤ 0.11mg/m³ GB/T 18883-2022
Indoor odor No irritating odor on delivery Visual/olfactory inspection
Ready-to-occupy Immediate after installation — no air-out period required —

10.7 Fire & Abrasion Performance of Interior Finishes

Item Performance Requirement Standard
—— ———————— ———-
Floor covering fire rating B1 (flame-retardant), smoke density ≤ 75% GB 8624-2012
Ceiling panel fire rating A (non-combustible steel surface) GB 8624-2012
Interior wall surface fire rating B1 (flame-retardant) GB 8624-2012
Floor covering abrasion Class T — withstands 20,000+ cycles GB/T 11982.1-2015

10.8 Interior Lighting Environment & Spatial Comfort Design

Parameter Value
———– ——-
Office area maintained illuminance ≥ 300 lux at desktop level
Rest area maintained illuminance ≥ 100 lux at floor level
Uniformity of illumination (office) ≥ 0.7
Color rendering index (CRI) ≥ 80
Glare rating UGR ≤ 19 (office area)
Interior wall color reflectivity ≥ 0.75 (white upper walls)
Interior space volume per person ≥ 7m³/person (for 3-person occupancy)
Natural daylighting (window area / floor area ratio) ≥ 1/6

—

Chapter 11: Electrical System Technical Parameters

11.1 System Overview

The electrical system is designed per the Standard for Electrical Design of Civil Buildings (GB 51348-2019), providing complete power distribution, lighting, socket outlets, network/data connectivity, and safety protection. The system is factory pre-wired and tested, requiring only external connection at site. Power and data (weak current) wiring are physically separated to prevent electromagnetic interference.

11.2 Main Distribution Box

Parameter Specification
———– —————
Type Wall-mounted metal enclosure
Rated voltage 220V / 50Hz
Incoming capacity 5kW
Main breaker 32A/2P residual current operated circuit breaker (RCBO) with overload and short-circuit protection
Branch circuits 4 circuits total as follows
— Lighting circuit 1 × C10A RCBO
— General sockets circuit 1 × C16A RCBO
— Socket + air conditioning circuit 1 × C20A RCBO
— Reserved circuit 1 × C16A RCBO
Leakage protection sensitivity 30mA, trip time ≤ 0.1s (all socket circuits and general circuits)
Enclosure protection rating IP30 (indoor installation)
Busbar configuration Copper busbar, tinned
Enclosure material Cold-rolled steel, powder-coated

11.3 LED Ceiling Lights

Parameter Specification
———– —————
Type LED ceiling panel light
Rated power 24W per unit
Luminous flux ≥ 2400 lm
Efficacy ≥ 100 lm/W
Color temperature 4000K (neutral white)
CRI ≥ 80
Rated life ≥ 30,000 hours
Quantity per unit 4 (2 in office area, 2 in rest area)
Installation Surface-mounted on ceiling, quick-connect wiring

11.4 10A Five-Hole Socket Outlets

Parameter Specification
———– —————
Rating 10A / 250V AC
Configuration 2P+3P universal five-hole
Standard GB/T 1002-2008
Quantity per unit 8 total (4 in office area, 4 in rest area)
Safety feature Integrated safety shutters (child-proof)
Terminal type Screw-clamp terminals, suitable for 2.5mm² conductors

11.5 16A Air-Conditioner Socket Outlet

Parameter Specification
———– —————
Rating 16A / 250V AC
Standard GB/T 1002-2008 (16A three-pin)
Quantity per unit 1 (positioned in rest area for AC unit)
Dedicated circuit C20A RCBO from distribution box, 4mm² copper conductor

11.6 Lighting Switches

Parameter Specification
———– —————
Rating 10A / 250V AC
Type Rocker switch, white
Quantity per unit 4 (2 for office lights, 2 for rest lights)
Special feature Rest area switches dual-controlled for convenient access

11.7 Network / Data Sockets

Parameter Specification
———– —————
Type RJ45 Cat6 shielded modular jack
Standard TIA/EIA-568.2-D
Bandwidth 250MHz
Quantity per unit 4 (2 in office area, 2 in rest area)
Data cabling Cat6 UTP solid copper, run to wall-mounted junction/termination box

11.8 Full-House Wiring Kit

Parameter Power Wiring Data Wiring
———– ————- ————-
Conductor type BV single-core copper cable Cat6 UTP
Wire gauge (lighting) 2.5mm² —
Wire gauge (sockets) 2.5mm² —
Wire gauge (AC circuit) 4.0mm² —
Wire gauge (main feed) 6.0mm² —
Conduit PVC conduit (φ20 / φ25) PVC conduit (φ20)
Color coding Live: Red/Brown; Neutral: Blue; Earth: Yellow-Green Blue/Slate jacket
Routing Separate conduits from data wiring (≥ 300mm separation) —

11.9 Outdoor Waterproof Inlet Box

Parameter Specification
———– —————
Type IP66 outdoor weatherproof junction/connection box
Material UV-stabilized ABS / polycarbonate
Ratings IP66 ingress protection, 10A / 250V
Connection External cable entry via IP68 cable gland; internal connection to main distribution box
Application point External wall, near building service corner

11.10 Electrical Safety Protection Design

Protection Layers:

  1. Residual Current Protection: All socket circuits and general-purpose circuits protected by 30mA RCD/RCBO — operates within 0.1s of leakage fault.
  2. Overload & Short-Circuit Protection: All circuits individually protected by MCB/RCBO at correct ratings.
  3. Earth Bonding: All exposed metal parts (frames, enclosures) are bonded to earth via dedicated earth conductor. Earth resistance ≤ 4Ω as verified at commissioning.
  4. Insulation: All live parts double-insulated per class II requirements; wiring insulation voltage rating 450/750V.
  5. Mechanical Protection: All cables protected within PVC conduit throughout; junction boxes are enclosed and secured.

11.11 Electrical Load Calculation & Cable Sizing Verification

Load Category Quantity Unit Power Total Load
————— ———- ———– ————
LED ceiling lights 4 24W 96W
10A socket outlets (general) 8 500W (max simultaneous) 1000W
16A AC outlet (AC unit) 1 1500W 1500W
Office equipment (est.) — 800W 800W
Total design load — — ≤ 3.5kW
Design capacity — — 5kW (30% margin)
Cable Verification Requirement Calculated Result
——————– ————- ———— ——–
Main feed 6mm² copper current capacity ≥ 32A 47A Pass
AC circuit 4mm² copper current capacity ≥ 20A 38A Pass
Socket circuit 2.5mm² current capacity ≥ 16A 27A Pass
Voltage drop at design load (whole circuit) ≤ 5% 1.8% Pass

11.12 Earthing & Lightning Protection Design

Item Design Detail
—— —————
Earthing system type TN-S (separate PE conductor throughout)
Earthing electrode Provided by site foundation or supplied grounding rod (L1200 × 16mm copper-clad steel) when required
Earth resistance requirement ≤ 4Ω
Lightning protection approach Building is a movable unit — no fixed lightning rod by design. In areas with high lightning density, site-supplied lightning rod + down conductor + earth electrode recommended
Equipotential bonding All metal exterior components (roof panels, wall panels, frames) are interconnected and bonded to earth
SPD (surge protection) Type 3 surge protective device fitted within main distribution box as standard

—

Chapter 12: Water Supply & Drainage System Technical Parameters

12.1 System Overview

The water supply and drainage system is designed per the Standard for Design of Building Water Supply and Drainage (GB 50015-2019). The system includes cold water supply piping from external connection point to the washbasin, and drainage piping from the washbasin and floor drain to the external discharge point. All piping is concealed within wall/floor cavities for a clean appearance.

12.2 Water Supply Piping

Parameter Specification
———– —————
Material PPR (polypropylene random copolymer) pipe
Standard GB/T 18742-2017 (Polypropylene (PP) Piping Systems)
Cold water pipe diameter DN20 (inlet) / DN15 (to faucet)
Pipe rating PN1.6MPa
Working temperature range 5℃ – 95℃
Connection method Heat-fusion welded joints
Installation Concealed within wall cavity/floor cavity
Supply point 1 × pedestal washbasin with dual-connection for hot/cold faucet

12.3 Drainage Piping

Parameter Specification
———– —————
Material PVC-U (unplasticized polyvinyl chloride)
Standard GB/T 5836.1-2018 (Unplasticized Poly(Vinyl Chloride) (PVC-U) Pipes for Soil and Waste Discharge)
Main drain diameter DN50
Connection method Solvent cement joints
Slope requirement ≥ 1% (toward external outlet)
External connection DN50 flexible adapter for site connection
Venting Internal trap vents through anti-siphon valve on washbasin drain

12.4 Pedestal Washbasin

Parameter Specification
———– —————
Type White ceramic pedestal washbasin
Dimensions Approx. 560mm (W) × 450mm (D)
Faucet type Single-lever chrome faucet, dual water supply connections
Water supply connection DN15 flexible braided hoses to shut-off valve
Drain connection DN32 basin waste with trap
Overflow Built-in overflow channel
Mounting Pedestal floor-standing

12.5 Main Water Supply Shut-Off Valve

Parameter Specification
———– —————
Type Brass ball valve
Connection size DN20
Working pressure 1.6MPa
Application point Inlet side, just inside building; accessible access panel
Function Emergency shut-off and isolation for system maintenance

12.6 Odor-Trap Floor Drain

Parameter Specification
———– —————
Type Stainless steel floor drain with deep-seal water trap
Trap seal depth ≥ 50mm
Drain opening 100mm × 100mm
Material 304 stainless steel cover, ABS body with PVC-U extension
Water seal function Prevents sewer gas backflow into interior
Cleaning access Removable grate with sediment basket

12.7 Water Supply System Hydraulic Calculation

Parameter Value
———– ——-
Design flow rate (peak) 0.15 L/s
Inlet pressure requirement ≥ 0.1MPa (as per Chapter 2 specification)
Pipe friction loss (DN20 at 0.15 L/s) ≤ 0.02 MPa over 10m run
Available pressure at highest fixture ≥ 0.02MPa (sufficient for faucet operation)
Flow rate at faucet (at 0.1MPa inlet) ≥ 6 L/min
Verification result Water supply meets peak demand with 2× margin

12.8 Drainage System Flow Capacity Verification

Parameter Value
———– ——-
Drainage design flow (washbasin + floor drain simultaneous) 0.3 L/s (conservative)
DN50 PVC-U drain capacity at 1% slope (full bore) ≥ 1.2 L/s
System capacity utilization 25% — 80% capacity reserve
Verification result Drainage system has exceptional capacity margin; no blockage risk under normal use

12.9 Freeze Protection & Leak Prevention Design

Item Design Measure
—— —————-
Freeze protection Recommended site measures: drain-back valve on external supply, insulation wrap on exposed piping (site-provided in severe cold regions); PPR pipe tolerant to brief freezing without rupture
Leak prevention All joints heat-fusion welded (water supply) — no threaded joints in concealed zones; full water test at factory (1.0MPa for 30 min) and after installation (0.8MPa for 30 min)
Condensation prevention Cold pipe insulated with closed-cell rubber foam ≥ 9mm in warm/humid climates
Flood prevention Floor drain at lowest point of washroom area; overflow protection via basin overflow channel

12.10 Water System Hygiene Performance

Parameter Value
———– ——-
Piping material hygiene compliance GB/T 17219-2001 (Hygienic standard for drinking water pipes) — complies
Water stagnation prevention System flushed and sanitized before delivery; all pipe ends capped/sealed during transit
Inlet strainer 60-mesh stainless steel strainer fitted at shut-off valve inlet
Surface cleanliness All concealed pipes inaccessible — exposed sections finished flush & clean
System disinfection System disinfected with chlorinated water (≥ 50mg/L) for 30 min before commissioning

—

Chapter 13: Office & Living Furniture System Technical Parameters

13.1 System Overview

The furniture system is factory-supplied and installed, providing complete office and living functionality. All furniture is designed to commercial/industrial standards with environmental safety compliance, appropriate load capacity and durable construction suitable for daily use in outdoor field conditions.

13.2 Double-Layer Steel Bunk Bed

Parameter Specification
———– —————
Configuration Double-layer bunk bed
External dimensions 2000mm (L) × 1200mm (W) × 1800mm (H)
Frame material Cold-rolled steel square tube ≥ 40mm × 40mm × 1.5mm
Guardrail 30mm × 30mm × 1.2mm steel tube, full-length upper guardrail
Ladder Integrated welded steel ladder, anti-slip treads
Bed slats 5 slats per level, 18mm particleboard, recessed frame support
Load capacity per level ≥ 300kg uniformly distributed
Surface treatment Electrostatic powder coating, scratch-resistant
Finish color White
Assembled stability Rocking test: ≤ 5mm displacement
Standard GB/T 3325-2017 (Metal furniture)

13.3 Folding Single Bed

Parameter Specification
———– —————
Type Foldable single bed
Unfolded dimensions 1900mm (L) × 800mm (W) × 350mm (H)
Frame material 20mm × 20mm × 1.0mm steel tube
Bed surface Woven fabric/vinyl sling
Folded dimensions Approx. 1900mm (L) × 800mm (W) × 120mm (thick)
Load capacity ≥ 150kg
Storage Stored in dedicated wall-mounted rack in rest area
Finished surface Powder-coated steel frame

13.4 Staff Office Desk

Parameter Specification
———– —————
Configuration Single-person desk
Desk top dimensions 1200mm (W) × 600mm (D) × 750mm (H)
Desk top material 25mm thickened particleboard with laminated finish
Frame material 1.2mm cold-rolled steel legs, powder-coated
Edge treatment PVC edge banding, heat-sealed
Load capacity (desk top) ≥ 100kg uniformly distributed
Storage 2 pull-out drawers, 1 file drawer (selected desk)
Cable management Integrated cable tray/grommet on selected desks
Finish color White top / gray frame
Quantity 2 units

13.5 Office Chair

Parameter Specification
———– —————
Type Swivel office chair with armrests
Seat material High-density foam (≥ 45kg/m³), PU upholstery
Backrest High-back ergonomic mesh/foam
Adjustment Seat height adjustable (gas lift), tilt-lock backrest
Base Five-star nylon/PU caster base
Load capacity ≥ 150kg
Standard BIFMA / GB/T 3325-2017 compliance
Quantity 3 units

13.6 Steel Filing Cabinet

Parameter Specification
———– —————
Configuration Two-door lockable filing cabinet
Dimensions 900mm (W) × 400mm (D) × 1850mm (H)
Material 0.8mm cold-rolled steel plate
Interior 3 fixed shelves, adjustable
Finish Electrostatic powder coating, scratch-resistant
Locking Central locking mechanism, 2 keys
Load capacity per shelf ≥ 50kg
Finish color White
Standard GB/T 3325-2017
Quantity 1 unit

13.7 Two-Door Locker

Parameter Specification
———– —————
Configuration Two-door individual locker
Dimensions 800mm (W) × 500mm (D) × 1850mm (H)
Material 0.8mm cold-rolled steel plate
Interior Each compartment: 2 shelves, 1 clothing hanging rod
Ventilation Louvered vents in doors
Locking Individual cam locks, 1 key per compartment
Finish Electrostatic powder coating
Finish color White
Standard GB/T 3325-2017
Quantity 1 unit (2 compartments)

13.8 Furniture Environmental & Safety Standards

Parameter Requirement Standard
———– ————- ———-
Formaldehyde emission (board products) ≤ 0.05mg/m³ (E1) GB 18580-2017
VOC content (laminates, finishes) Compliant with limits GB 18584-2001
Heavy metal content (finishes) Within limits (Pb, Cd, Cr, Hg) GB 18584-2001
Edge sharpness All exposed edges rounded or edge-banded GB 28007-2011
Stability No tipping under lateral 20kg top-load test GB/T 3325-2017
Load safety factor 1.5× rated load without permanent deformation GB/T 3325-2017

13.9 Furniture Load & Durability Test Specifications

Test Item Requirement Standard
———– ————- ———-
Desk top static load 100kg for 24h, no permanent deformation > 1mm GB/T 3325-2017
Bunk bed load test 300kg per level for 24h, deflection ≤ 10mm, no permanent deformation Factory test
Locker/File cabinet load 50kg per shelf, door operation normal after test GB/T 3325-2017
Chair dynamic fatigue 100,000 cycles seat height adjustment; 50,000 cycles rocking test BIFMA X5.1
Surface abrasion resistance ≥ 500 cycles abrasion test without exposing substrate GB/T 4893.8-2023
Humidity/temperature cycling No delamination, blistering or warping after 72h damp-heat cycle GB/T 4893.1-2021

—

Chapter 14: HVAC & Ventilation System Technical Parameters

14.1 System Overview

The HVAC and ventilation system comprises one wall-mounted split air conditioner for cooling/heating, one louvered exhaust fan for positive ventilation, and natural ventilation openings via windows. The system is engineered to maintain comfortable indoor temperatures across outdoor ambient conditions from -10℃ to 45℃, with controlled indoor humidity and fresh air exchange.

14.2 Wall-Mounted Split Air Conditioner

Parameter Specification
———– —————
Type Wall-mounted split heat pump
Cooling capacity 3500W (1.5 HP class)
Heating capacity 4200W (heat pump)
Inverter Yes — DC inverter compressor
Energy efficiency rating ≥ Level 1 (SEER / HSPF high efficiency)
Rated power consumption (cooling) Approx. 1050W
Rated power consumption (heating) Approx. 1250W
Power supply 220V / 50Hz, dedicated 16A circuit
Indoor unit dimensions Approx. 900mm × 300mm × 200mm
Outdoor unit dimensions Approx. 800mm × 550mm × 300mm
Refrigerant R32 (GWP = 675, ozone-friendly)
Operating ambient range -15℃ to +50℃ (cooling); -20℃ to +24℃ (heating)
Airflow volume 650 – 800 m³/h (high speed)
Noise level (indoor) ≤ 38dB(A) (low speed)
Noise level (outdoor) ≤ 52dB(A)
Installation Indoor unit high-mounted on rest area wall; outdoor unit on external wall bracket or freestanding base
Standard GB/T 7725-2004; GB 21455-2019 (energy efficiency)
Warranty Per manufacturer national warranty policy

14.3 Louvered Exhaust Fan

Parameter Specification
———– —————
Type Wall-mounted louvered exhaust fan
Blade diameter 250mm
Airflow capacity ≥ 720 m³/h
Power consumption ≤ 35W
Noise level ≤ 45dB(A)
Installation location External wall, upper wall area (office zone)
Control Manual switch, 3-speed (selected models)
Backdraft shutter Integrated gravity louver prevents backdraft

14.4 Indoor Thermal Comfort Calculation

Design Condition Cooling Mode Heating Mode
—————— ————– ————–
Outdoor temperature 35℃ (design) 0℃ (design)
Indoor setpoint 26℃ 20℃
Indoor relative humidity 40–60% 30–50%
Cooling load estimate 3.1kW (calculated) Heating load estimate: 3.5kW
Installed capacity 3.5kW 4.2kW
Capacity margin 13% margin 20% margin
Verification result Passes comfort requirement Passes comfort requirement

14.5 Ventilation Rate Design Verification

Parameter Value
———– ——-
Interior volume 21㎡ × 2.7m = 56.7m³
Required air changes per hour (occupancy) ≥ 10 ACH (intermittent) / ≥ 3 ACH (continuous)
Exhaust fan capacity 720 m³/h = 12.7 ACH
Natural ventilation (windows open) Up to 15 ACH (cross-ventilation)
Verification result Ventilation capacity exceeds 10 ACH requirement with 27% margin
COâ‚‚ concentration (3 occupants, 10 ACH) Maintains below 800ppm in continuous use

14.6 System Energy Efficiency Analysis

Item Performance
—— ————-
Enthalpy load reduction via insulation ≥ 60% heat transfer blocked through envelope
Inverter AC partial-load efficiency Higher seasonal efficiency vs. fixed-speed units
Combined energy consumption estimate (cooling season 6 months, 12h/day) Approx. 1,200 – 1,500 kWh/year
Energy cost saving compared with masonry building ≥ 25% annually
Standby power consumption ≤ 1W (inverter standby)

14.7 Equipment Noise Control Specifications

Source Noise Limit Control Measure
——– ————- —————–
AC indoor unit ≤ 38dB(A) Low-noise fan design; high mounting position
AC outdoor unit ≤ 52dB(A) Installed on vibration-isolating pads; away from bedroom head area
Exhaust fan ≤ 45dB(A) Balanced impeller; low-speed setting for continuous night operation
Interior background noise (all systems off) ≤ 30dB(A) Envelope sound insulation ≥ 30dB

—

Chapter 15: Transport, Installation & Site Foundation Technical Parameters

15.1 Sealing & Fixing Accessory Materials

Component Specification
———– —————
Butyl sealing tape 20mm × 2mm roll, used at panel joints
Neutral silicone sealant Weather-resistant, UV-stable, color-matched
EPDM sealing strips 10mm × 5mm, for door/window perimeter
Expansion anchor bolts M12 × 120mm, for foundation fixing
Waterproofing membrane (base) Self-adhesive modified bitumen membrane, 2mm thick, laid under bottom frame
Sealing washers EPDM-backed washers for all roof-penetrating screws
Pu foam sealant Expansion foam for gap filling (concealed areas only)

15.2 Professional Installation & Construction Standards

Stage Standard / Requirement
——- ————————
Site preparation Per JGJ/T 492-2018 (Technical Standard for Modular Buildings)
Foundation checking Concrete level tolerance: ± 5mm / 3m straight edge; corners within ± 3mm level
Unit positioning Positioning tolerance: ± 10mm from design plan; orientation per drawings
Leveling Leveling via shims at base connections, then anchor bolt installation
Structure assembly Bolted connections tightened to specified torque; self-tapping screws at ≤ 300mm spacing
Panel installation Vertical surface tolerance: 2mm/3m; panel joints ≤ 2mm gap
Sealing Sealant applied continuously — no missed or cut joints
Electrical termination Per GB 51348-2019; all connections tight; polarity verified
Plumbing connection Per GB 50015-2019; all joints watertight; system pressure tested
Final inspection Per Chapter 15.6 acceptance process

15.3 Whole-Unit Transportation Plan & Requirements

Item Requirement
—— ————-
Transport mode Standard 17.5m flatbed truck (4.2m usable width)
Loading configuration Single unit per truck (7000mm length fits within 17.5m bed)
Lifting equipment (loading/unloading) 20-ton crane or forklift (rated ≥ 8 tons)
Lifting method 4-point sling lifting at designated corner lifting points
Transit bracing Internal bracing at door and window openings; furniture secured; loose parts packed separately
Waterproof wrapping Full-body waterproof canvas/sheet wrap during transit
Road requirements Standard highway clearance; entry road recommended ≥ 7.5m driveway width
Transport tilt limit ≤ 5° during transit (road gradient)
Offloading at site Crane or hydraulic tailgate; ground bearing capacity ≥ 80kN/m² for crane outriggers

15.4 Site Concrete Ground Foundation Parameters

Parameter Specification
———– —————
Foundation type Reinforced concrete slab on grade
Concrete grade C20 (minimum)
Slab thickness 100mm (standard) / 150mm (recommended for permanent installations)
Reinforcement φ8@200mm × 200mm welded wire mesh (at mid-slab)
Slab dimensions 7000mm (length) × 3000mm (width) + 200mm perimeter overhang = 7400mm × 3400mm
Pre-formed anchor positions 4 corner anchor positions at 7000mm × 3000mm centers, tolerance ± 10mm
Surface tolerance ± 5mm per 3m straight edge; slope not exceeding 0.3% toward drainage
Concrete curing Minimum 7 days before load application
Sub-grade compaction ≥ 95% standard proctor density
Frost protection (cold regions) Sub-base below frost depth or 150mm compacted gravel base (site design as required)
Standard reference GB 50007-2011 (Code for Design of Building Foundation)

15.5 Foundation Bearing Capacity Verification

Parameter Value
———– ——-
Total structural weight (unloaded) Approx. 4.5 tons
Foundation contact area 7.0m × 3.0m = 21㎡
Average unit pressure (unloaded) ≈ 21.4 kN/㎡
Design bearing capacity (C20 slab on compacted ground) ≥ 100 kN/㎡
Capacity utilization 21% — substantial safety margin (Factor of Safety ≥ 4.5)
Wind overturning moment check Worst-case Grade-10 wind (0.55kN/㎡) — overturning safety factor ≥ 2.1 (anchored)

15.6 Installation Acceptance Standards & Process

Acceptance Stage Inspection Items Standard
—————— —————— ———-
Stage 1 — Foundation Concrete grade, surface level, anchor positions Level tolerance ± 5mm/3m; anchors within ± 10mm
Stage 2 — Structure Frame verticality, connections, tightness Verticality ± 4mm total; bolts torqued to spec
Stage 3 — Enclosure Panel joints, alignment, sealant coverage Joints ≤ 2mm; sealant continuous & uniform
Stage 4 — Doors & Windows Open/close function, gap uniformity, water tightness Smooth operation; gaps uniform within 2mm
Stage 5 — Electrical Continuity, insulation resistance, RCBO operation Insulation ≥ 0.5MΩ; RCD trip test at 30mA
Stage 6 — Plumbing Pressure test, flow, drainage, no leaks 0.8MPa 30min no drop; drain no-block
Stage 7 — HVAC AC operation, heating/cooling, exhaust fan operation AC reaches setpoint at 1.5h; exhaust air flow ≥ 720m³/h
Final Acceptance Full documentation, key handover, client sign-off Completed checklist & acceptance certificate

—

Chapter 16: Core Advantages of the Solution

16.1 Integrated Factory-Prefabrication Advantage

With a factory prefabrication rate exceeding 95%, all structural, enclosure, electrical, plumbing, decoration and furniture systems are manufactured, pre-assembled and quality-tested at our Guangzhou production base. This eliminates most on-site labor, ensuring consistent quality control, reduced weather dependency, and the elimination of multi-trade coordination issues on site. Result: higher quality, faster delivery, lower risk.

16.2 Structural Safety & Reliability Advantage

The Q235B hot-dip galvanized steel structure is engineered and tested to withstand Grade-10 winds and 7-degree seismic events, with a designed service life of 15+ years for the main structure. The dual anti-corrosion system (hot-dip galvanizing + touch-up coating) ensures long-term structural integrity across diverse climates — from humid coastal areas to arid inland regions. This is a robust, industrialized system backed by 20+ years of manufacturing heritage.

16.3 Rapid Deployment Advantage

From factory delivery to full operational status: 3 days. The unit arrives as a complete system — simply place on the prepared foundation, connect power and water, and move in. This is a genuine turnkey solution that eliminates construction site delays, making it ideal for time-critical projects across the USA, Europe, Southeast Asia, the Middle East and Africa.

16.4 All-Scenario Environmental Adaptability

Engineered to perform reliably in ambient temperatures ranging from -10℃ to +45℃, the unit handles heavy rain, wind, humidity and heat through its triple waterproof defense, high-performance insulation, anti-condensation detailing and versatile HVAC system. Whether deployed in tropical Southeast Asia, Middle East desert heat, or cold European winters, the unit maintains a comfortable, dry and protected interior environment.

16.5 Energy-Efficient Insulation Advantage

The 50mm insulated sandwich panel envelope, reinforced roof insulation layer and triple-sealed door/window system achieve an overall envelope U-value of ≤ 0.6W/(㎡·K) — approximately 75% better than typical temporary structures. This translates directly to lower HVAC energy consumption, reduced operating costs and a smaller carbon footprint — a meaningful sustainability contribution for ESG-conscious organizations.

16.6 Full-Function Integration Advantage

Unlike conventional modular units that ship as empty shells, our station arrives complete with office furniture, beds, lockers, air conditioning, water supply, drainage and interior decoration — literally “plug and live.” Procurement teams save significant time and cost by receiving one fully integrated product rather than sourcing multiple suppliers for fit-out items.

16.7 Full-Lifecycle Cost Control Advantage

Consider the total cost of ownership across years of operation: factory-precision manufacturing reduces maintenance frequency; universal components reduce spare-part costs; energy-efficient envelope reduces utility bills; and the unit’s relocatability eliminates repeat construction costs when sites change. The result is a lower total cost of ownership than traditional construction or low-grade alternatives.

16.8 Relocatable & Reusable Advantage

The unit is designed for repeated integral relocation. When the project site changes, the unit is simply disconnected from utilities, crane-loaded onto a flatbed, transported to the new site, and reinstalled on a new foundation — typically within 1–2 days. This asset retains residual value over multiple deployments, making it an investment rather than an expense. KITOZER as your direct manufacturer supports you across the entire asset lifecycle.

—

Chapter 17: Common Technical Q&A

17.1 General Knowledge Q&A

Q1: What is the overall size and weight of this unit?

A: External dimensions are 7000mm × 3000mm × 2900mm (L × W × H incl. parapet). Total structural weight is approximately 4.5 tons (unloaded).

Q2: How many people can this unit accommodate?

A: Designed for 2–3 people. Two fixed beds in the rest area plus one folding bed provide accommodation for up to 3 persons. The office area seats 2–3 persons simultaneously.

Q3: Does the unit arrive fully furnished?

A: Yes. The standard configuration includes office desks, chairs, filing cabinet, locker, bunk bed, folding bed, air conditioner, LED lighting, electrical system, water supply & drainage system, and complete interior decoration — truly move-in ready.

17.2 Structural Safety Q&A

Q1: What is the structural service life?

A: Main steel structure ≥ 15 years; enclosure system ≥ 10 years. With routine maintenance (touch-up paint, sealant replacement), service life can be extended beyond these periods.

Q2: Can it withstand typhoons and earthquakes?

A: Yes. The structure is designed and verified to withstand Grade-10 wind loads (basic wind pressure 0.55kN/㎡) and seismic intensity of 7 degrees (0.10g). The steel frame’s ductility and bolted connections allow controlled energy dissipation during seismic events.

Q3: What happens if the site ground is not perfectly level?

A: The bottom frame can be shimmed and grouted during installation to achieve level. Maximum allowable leveling adjustment is ± 30mm via shims before anchoring.

17.3 Enclosure Performance Q&A

Q1: Will the roof leak during heavy rain?

A: No. The roof system incorporates a triple waterproofing defense: tongue-and-groove panel interlocking, continuous weather-resistant sealant, and positive slope drainage to gutter and downpipe system. The system is tested against heavy rain conditions.

Q2: Is the unit insulated for extreme heat or cold?

A: Yes. The 50mm EPS sandwich panels plus roof reinforcement layer achieve a heat transfer coefficient of ≤ 0.6W/(㎡·K) — comparable to permanent building insulation levels. Combined with the inverter air conditioner, comfortable indoor temperatures are maintained from -10℃ to +45℃ outdoors.

Q3: Will there be condensation inside during humid weather?

A: No — by design. The envelope’s high insulation value keeps interior surfaces above dew point. Additionally, the exhaust fan can be operated to actively control indoor humidity in extreme humid conditions.

17.4 Electrical & Plumbing Configuration Q&A

Q1: What power supply is required?

A: Standard single-phase 220V/50Hz supply, with a design load of 5kW. A dedicated 10mm² (or 6mm² per local code) incoming cable is recommended. Our system is factory-pre-wired internally; only external connection is required.

Q2: What water supply is needed?

A: A mains water connection (≥ 0.1MPa pressure) via standard DN20 connection, or connection to a pressure tank/storage water system. The entire internal system comes pre-plumbed.

Q3: Can the unit work without external water supply?

A: Yes — with a site-supplied water tank and small pressure pump connected to the inlet. Our team can advise on the appropriate configuration for your site.

17.5 Functional Layout Q&A

Q1: Can the interior layout be customized?

A: Yes. As the manufacturer, we can adjust the interior partition position, furniture configuration and electrical/plumbing point locations to suit your specific requirements. Lead time for customization varies based on complexity.

Q2: Is there enough space for both office and bedroom use?

A: The 21㎡ usable area is divided into approximately 12㎡ office area and 9㎡ rest area, providing comfortable space for both functions. The layout is optimized to avoid “cramped” feeling while maximizing utility.

17.6 Procurement & Delivery Q&A

Q1: What is the production lead time?

A: Standard units: 15–20 working days from order confirmation and drawing approval. Customized units: 25–35 working days depending on modification scope.

Q2: How is the unit shipped?

A: By standard 17.5m flatbed truck, one unit per truck. For overseas projects, units ship in breakbulk or containerized format (disassembled into sub-assemblies) as required by logistics constraints.

Q3: Can you supply for overseas projects?

A: Absolutely. Guangzhou Lain / KITOZER exports across Southeast Asia, the Middle East, Africa, Europe, the USA and global markets. We have extensive experience in export packaging, sea-freight logistics and overseas installation support.

17.7 After-Sales & Maintenance Q&A

Q1: What warranty is provided?

A: Main steel structure: 2 years. Other systems: 1 year. Air-conditioning equipment: per manufacturer policy. See Chapter 20 for complete warranty terms.

Q2: How do I get spare parts?

A: All components use universal standard specifications. Spare parts can be ordered directly from us or sourced locally from standard suppliers. See Chapter 20 for more details.

Q3: What maintenance is needed?

A: Minimal. Annual inspection of sealants and roof fixings, periodic cleaning of gutters and air-conditioner filters, and general cleaning. Full maintenance guide provided at handover.

—

Chapter 18: Construction Schedule

18.1 Overall Construction Duration Planning

Phase Duration Description
——- ———- ————-
Factory prefabrication 15–20 working days Structure fabrication, panel installation, factory pre-assembly, internal systems installation, quality inspection
Transport & delivery 1–5 days (domestic) / port-dependent (overseas) Loading, transport from Guangzhou factory to project site
Site installation 3 days Foundation prep (day 1), structure & systems installation (day 2), commissioning & handover (day 3)
Total turnaround (domestic) Approx. 19–28 days From order confirmation to operational handover

18.2 Factory Prefabrication Phase Schedule

Day Activity
—– ———-
Day 1–2 Steel structure cutting, drilling, forming
Day 3–4 Structure assembly & welding, hot-dip galvanizing process
Day 5–7 Frame assembly, roof & wall panel installation
Day 8–10 Door & window installation, interior partition
Day 11–12 Electrical system installation & wiring
Day 13 Plumbing system installation
Day 14–15 Interior decoration completion (flooring, ceiling)
Day 16–17 Furniture installation, equipment mounting
Day 18 Full-system testing, quality inspection
Day 19–20 Cleaning, packaging, load-out

18.3 Transport Phase Schedule (Domestic)

Day Activity
—– ———-
Day 1 Loading at factory, securing cargo
Day 2–4 Highway transport to project site (varies by distance)
Day 5 Offloading at site, positioning on foundation

18.4 Site Installation Phase Schedule

Day Activity
—– ———-
Day 1 (AM) Site survey, foundation inspection, base waterproofing membrane installation
Day 1 (PM) Unit offloading into position, leveling, anchor bolt fixing
Day 2 (AM) Electrical external connection, plumbing external connection
Day 2 (PM) Sealant application (exterior), final joint cosmetic treatment
Day 3 (AM) Full-system commissioning (electrical, plumbing, HVAC function tests)
Day 3 (PM) Final inspection, client walkthrough, documentation handover

18.5 Key Milestone Management Plan

Milestone Target Date Control Method
———– ————- —————-
Drawing approval Day 0 Client sign-off on dimension/layout drawings
Structure completion Day 4–5 of production Factory QC inspection, photo documentation
Pre-shipment inspection Day 18–19 Client QC approval before shipment
Site handover Day 3 of site work Signed acceptance certificate

18.6 Schedule Assurance Measures

  • Dedicated production line: Standard units are produced on dedicated lines with dedicated crews.
  • Material inventory: Long-lead materials (steel, panels, AC units) held in stock to eliminate procurement delays.
  • Parallel operations: Overlapping production activities (e.g., electrical wiring concurrent with wall panel installation).
  • Regular reporting: Weekly production progress reports with photos to client/EPC.
  • Contingency capacity: Backup production crew capacity ± 20% to recover from any delays.

18.7 Delay Contingency Plan

Risk Impact Mitigation
—— ——– ————
Steel material delay Production start delay Stock inventory & alternative supplier agreements
Transport delay (weather, road) Delivery delay Advance dispatch; flexible shipping alternatives
Site foundation not ready Installation delay Pre-installation site survey; modular unit staged at factory until site ready
Extreme weather during installation 1–2 day delay Covered waterproofing plan, flexible crew scheduling
Force majeure events Project-wide delay Commercial terms with force majeure clause (per contract standard terms)

—

Chapter 19: Construction Organization Plan

19.1 Project Organization Structure

The project team is structured to ensure clear accountability and efficient coordination:

“`

Project Manager (1)

├── Production Coordinator (1) — Factory production scheduling & quality

├── Logistics Coordinator (1) — Transport & delivery arrangement

├── Site Installation Supervisor (1) — On-site installation & commissioning

│ ├── Installation Crew (3–4 persons) — Structure, enclosure, interior

│ ├── Electrical Technician (1) — Power & data wiring completion

│ └── Plumbing Technician (1) — Water supply & drainage completion

└── QC / Acceptance Engineer (1) — Quality inspections at factory & site

“`

19.2 Pre-Construction Preparation

Task Requirement
—— ————-
Site survey Confirm delivery access, crane positioning, ground bearing capacity
Client coordination Confirm utilities connection points (power, water, drainage)
Document approval Final drawing approval from client before production starts
Team mobilization Assign project manager, confirm crew availability
Tooling & equipment Site tools: crane (client-sourced or as specified), hand tools, power tools, leveling equipment
Permits Confirm any local permits required for temporary structures

19.3 Main Steel Structure Installation Process

Step Procedure
—— ———–
1 Position bottom frame on foundation — check level and anchor positions
2 Fix bottom Frame to foundation via anchor bolts (M12 × 120mm expansion) at all 4 corners
3 Erect four corner columns — bolt to bottom frame corner gussets
4 Install top-frame longitudinal beams — bolt to column tops
5 Install top-frame transverse purlins — bolt/self-tap to longitudinal beams
6 Install wall vertical & horizontal studs at marked positions
7 Verify frame verticality (≤ ± 4mm), tighten all bolted connections to specified torque
8 Apply touch-up zinc-rich paint at all connection points

19.4 Enclosure System Installation Process

Step Procedure
—— ———–
1 Lay self-adhesive waterproofing membrane at base before wall installation
2 Install lower wall panels (light gray): align with frame, screw-fix with sealing washers
3 Install decorative waistband panel across mid-height line
4 Install upper wall panels (off-white): screw-fix to wall studs
5 Install external/internal corner trims and edge trims
6 Seal all panel joints with neutral silicone sealant — continuous bead, tooled flush
7 Install roof insulation reinforcement layer between purlins
8 Install roof panels (ocean blue): screw-fix with sealing washers, interlock joints
9 Install parapet edge trims (45° mitered corners), seal all joints
10 Install gutter, downpipes and rain hoppers ensuring slope toward outlets

19.5 Door & Window Installation Process

Step Procedure
—— ———–
1 Position door/window frames into prepared openings
2 Shim and level frames — check square and vertical (within ± 2mm)
3 Fix frames to wall studs with self-tapping screws at ≤ 300mm spacing
4 Apply EPDM sealing strips around door/window perimeters
5 Hang door leaves / install sliding sashes — check smooth operation
6 Apply exterior sealant around all frame-to-wall junctions
7 Install hardware (locks, handles, window locks) and check operation
8 Install mosquito screens on sliding windows

19.6 Interior Decoration Installation Process

Step Procedure
—— ———–
1 Install floor base panels on bottom-frame secondary beams — screw-fix at ≤ 300mm spacing, gap between panels ≤ 2mm
2 Seal panel joints and edges with moisture-resistant sealant
3 Lay PVC floor covering — full adhesive bonding, heat-welded seams
4 Install cove base around floor perimeter
5 Install ceiling panels — screw-fix to furring channels/purlins
6 Install interior partition wall — screw-fix to frame and ceiling/floor channels
7 Install interior door in partition opening
8 Install all trim pieces — ensure alignment and clean joints

19.7 Electrical System Installation Process

Step Procedure
—— ———–
1 Lay power conduits in wall cavities/under floor — separate from data conduits
2 Pull conductors through conduits, terminate at outlets/switches per circuit diagram
3 Install outlet boxes, switches, LED lights — flush mount
4 Install distribution box with RCBOs — test all circuits
5 Install data network wiring and RJ45 outlets
6 Connect external supply at outdoor waterproof inlet box
7 Complete insulation resistance test (≥ 0.5MΩ), RCD trip test at 30mA
8 Label all circuits at distribution board and outlet locations

19.8 Plumbing System Installation Process

Step Procedure
—— ———–
1 Lay PPR supply pipes in wall/floor cavities — continuous runs with heat-fusion joints
2 Install shut-off valve at inlet, connect to external water supply
3 Install washbasin, faucet, basin waste with trap
4 Lay PVC-U drain pipes from basin waste and floor drain, slope ≥ 1% toward outlet
5 Install floor drain with deep-seal trap at washroom area low point
6 Connect external drain pipe to site drainage system
7 Pressure test: supply 0.8MPa for 30 min — no pressure drop; visually inspect all joints
8 Flush system; verify drain flow by full-bore discharge test; check no leaks

19.9 HVAC Equipment Installation Process

Step Procedure
—— ———–
1 Install outdoor unit on wall bracket or concrete base — vibration-isolating pads
2 Install indoor unit on wall-mounted hanger — level alignment
3 Connect refrigerant lines between indoor/outdoor units (brazed, evacuated, pressure-tested)
4 Connect condensate drain line — sloped toward external discharge
5 Connect power supply from 16A dedicated circuit
6 Install exhaust fan in wall opening — seal external perimeter
7 Conduct system commissioning: cooling/heating mode test, airflow check, condensate drainage test

19.10 Quality Assurance System & Control Measures

Level Control Point Verification Method
——- ————— ———————
Incoming materials Steel, panels, electrical components Certificate of quality review; visual inspection
In-process (factory) Welding quality, dimension checks Per GB 50205-2001; dimensional tolerances per §6.12
Pre-shipment Full-system function test Test all circuits, plumbing pressure test, door/window operation
Site receiving Transport damage inspection Check panels, doors, windows for transport damage
Installation stages Structure, enclosure, MEP Per §15.6 stage gates — sign-off before move to next stage
Final commissioning Full operational test Completed checklist; client walkthrough sign-off

19.11 Safety & Civilized Construction Management

  • Safety Training: All installation crew receive site safety induction before work begins.
  • PPE Requirement: Hard hats, safety boots, gloves, safety harness (when working at height).
  • Crane Operations: Crane operator licenses verified; lifting plan reviewed before operation.
  • Electrical Safety: Lock-out/tag-out protocols during electrical connection work.
  • Site Cleanliness: Daily site clean-up; material storage organized; no debris left on site.
  • Noise Control: Operational noise during installation limited to daytime hours (per local by-laws).
  • Emergency Plan: Site first-aid kit, emergency contact list posted at site.

19.12 On-Site Emergency Response Plan

Emergency Type Response Procedure
—————- ———————
Minor injury Administer first aid at site first-aid kit; report to supervisor; if serious — call emergency services
Electrical shock Cut power immediately at distribution board; administer CPR if trained; call emergency services
Fire Cut power; use site extinguisher if safe; evacuate; call fire services
Crane accident Stop all work; secure area; call emergency services; notify project manager
Severe weather (typhoon/high wind) Secure loose panels, tools; evacuate working area; resume only after weather passes and safety check

—

Chapter 20: After-S